• 제목/요약/키워드: Capture efficiency

검색결과 343건 처리시간 0.025초

End-to-end system level modeling and simulation for medium-voltage DC electric ship power systems

  • Zhu, Wanlu;Shi, Jian;Abdelwahed, Sherif
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권1호
    • /
    • pp.37-47
    • /
    • 2018
  • Dynamic simulation is critical for electrical ship studies as it obtains the necessary information to capture and characterize system performance over the range of system operations and dynamic events such as disturbances or contingencies. However, modeling and simulation of the interactive electrical and mechanical dynamics involves setting up and solving system equations in time-domain that is typically time consuming and computationally expensive. Accurate assessment of system dynamic behaviors of interest without excessive computational overhead has become a serious concern and challenge for practical application of electrical ship design, analysis, optimization and control. This paper aims to develop a systematic approach to classify the sophisticated dynamic phenomenon encountered in electrical ship modeling and simulation practices based on the design intention and the time scale of interest. Then a novel, comprehensive, coherent, and end-to-end mathematical modeling and simulation approach has been developed for the latest Medium Voltage Direct Current (MVDC) Shipboard Power System (SPS) with the objective to effectively and efficiently capture the system behavior for ship-wide system-level studies. The accuracy and computation efficiency of the proposed approach has been evaluated and validated within the time frame of interest in the cast studies. The significance and the potential application of the proposed modeling and simulation approach are also discussed.

SEWGS 시스템을 위한 WGS 촉매들의 마모특성 (Attrition Characteristics of WGS Catalysts for SEWGS System)

  • 류호정;이동호;이승용;진경태
    • 한국수소및신에너지학회논문집
    • /
    • 제25권2호
    • /
    • pp.122-130
    • /
    • 2014
  • Attrition characteristics of WGS catalysts for pre-combustion $ CO_2$ capture were investigated to check attrition loss of those catalysts, to check change of particle size distribution during attrition tests, and to determine solid circulation direction of WGS catalysts in a SEWGS system. The cumulative attrition losses of two catalysts increased with increasing time. However, attrition loss under humidified condition was lower than that under non-humidified condition case for long-term attrition tests. Between two catalysts, attrition loss of PC-29 catalyst was higher than that of commercial catalyst for long-term attrition tests. However, the commercial catalyst generated much more fines than PC-29 catalyst during attrition. Therefore, we conclude that the PC-29 catalyst is more suitable for fluidized bed operation if we take into account the separation efficiency of cyclone. Based on the results from the tests for the effect of humidity on the attrition loss, we selected solid circulation direction from SEWGS reactor to regeneration reactor because the SEWGS reactor contains more water vapor than regeneration reactor.

Capture of Volatile Organic Iodine Species Using Mordenites

  • Tejaswini Vaidya;John P. Stanford;Nicolene van Rooyen;Krishnan Raja;Vivek Utgikar;Piyush Sabharwall
    • 방사성폐기물학회지
    • /
    • 제21권2호
    • /
    • pp.205-224
    • /
    • 2023
  • The emission of off-gas streams from used fuel recycling is a concern in nuclear energy usage as they contain radioactive compounds, such as, 3H, 14C, 85Kr, 131I, and 129I that can be harmful to human health and environment. Radioactive iodine, 129I, is particularly troublesome as it has a half-life of more than 15 million years and is prone to accumulate in human thyroid glands. Organic iodides are hazardous even at very low concentrations, and hence the capture of 129I is extremely important. Dynamic adsorption experiments were conducted to determine the efficiency of sodium mordenite, partially exchanged silver mordenite, and fully exchanged silver mordenite for the removal of methyl iodide present at parts per billion concentrations in a simulated off-gas stream. Kinetic analysis of the system was conducted incorporating the effects of diffusion and mass transfer. The possible reaction mechanism is postulated and the order of the reaction and the values of the rate constants were determined from the experimental data. Adsorbent characterization is performed to investigate the nature of the adsorbent before and after iodine loading. This paper will offer a comprehensive understanding of the methyl iodide behavior when in contact with the mordenites.

하드 디스크 드라이브 회전수 변화가 내부 필터 입자 포집 성능에 미치는 영향 (Effect of HDD Rotational Speed Variation on Filtration of Particles by Recirculation Filter)

  • 이대영;박희성;유용철;황정호
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1069-1076
    • /
    • 2002
  • Contamination particles in a hard disk drive can cause serious problems including slider crash and thermal asperities. A recirculation filter is typically installed in the hard disk drive to remove the particles. Measurements and theoretical predictions of particle concentration decay with the filter are carried out for a commercially available HDD. Especially, the effect of disk rotational speed on the particle capture efficiency is investigated. Results show that filter efficiency is higher for higher disk rotational speed.

생물막을 이용한 상수 원수에서의 암모니아 제거 특성 (Ammonia Removal Characteristics of Biolfilm Reactor)

  • 신항식;임경호;이상민
    • 상하수도학회지
    • /
    • 제10권1호
    • /
    • pp.78-84
    • /
    • 1996
  • The presence of ammonia, usually in the form of ammonium ion ($NH_4{^+}$), can enhance bacterial growth m the distribution system and make the production of drinking water more costly if ammonium must be removed to ensure good disinfection. Removal of ammonia by biological oxidation could be economical which prevents excess chlorine dosage In this research, effects of hydraulic retention time (HRT) and media type on the ammonia removal efficiencies of submerged biofilm reactor were investigated. The biofilm reactors combined the characteristics of high biological solids capture efficiency and good hydraulic control. The results indicate that biofilms can remove over 77 percent of the ammonia with HRT of longer than 2 hr even at low temperature ranging from 14.6 to $16.6^{\circ}C$. The HRT has a significant effect on nitrification. The overall nitrification and efficiency of ammonia removal increase with increasing HRT. It has also been observed that when the fibrous media was used, the ammonia removal, nitrification rate and endurance to shock improved.

  • PDF

Influence of the Recombination Parameters at the Si/SiO2 Interface on the Ideality of the Dark Current of High Efficiency Silicon Solar Cells

  • Kamal, Husain;Ghannam, Moustafa
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권2호
    • /
    • pp.232-242
    • /
    • 2015
  • Analytical study of surface recombination at the $Si/SiO_2$ interface is carried out in order to set the optimum surface conditions that result in minimum dark base current and maximum open circuit voltage in silicon solar cells. Recombination centers are assumed to form a continuum rather than to be at a single energy level in the energy gap. It is shown that the presence of a hump in the dark I-V characteristics of high efficiency PERL cells is due to the dark current transition from a high surface recombination regime at low voltage to a low surface recombination regime at high voltage. Successful fitting of reported dark I-V characteristics of a typical PERL cell is obtained with several possible combinations of surface parameters including equal electron and hole capture cross sections.

Application of magnetic field to iron contained dust capture

  • Huang, Shan;Park, Hae-Woo;Jo, Young-Min;Park, Young-Koo;Kim, Youn-Che
    • 한국응용과학기술학회지
    • /
    • 제31권1호
    • /
    • pp.59-65
    • /
    • 2014
  • Indoor air quality including metro subway is of recent interests in large cities. Inflow air to the inside of the train and circulating air flow through MVAC of stations contain large amount of iron based fine particles. This paper evaluated the collection of such a dust by magnetic filters as comparing to conventional particle capturing mechanisms such as inertia, direct impaction and diffusion. It was found that filtration velocity, magnetic field intensity, and fiber size were the most important parameters for magnetic filtration. Application of magnetic force obviously enhances the collection efficiency particularly in fine modes smaller than 10 mm. However, its effect was found greater in 2.5 mm than submicron particles.

10kW급 상반전 조류터빈의 설계와 성능에 관한 연구 (Design and Performance Evaluation of a 10kW Scale Counter-Rotating Tidal Turbine)

  • 황안둥;양창조
    • 한국유체기계학회 논문집
    • /
    • 제17권1호
    • /
    • pp.47-53
    • /
    • 2014
  • This paper aims to present the design and performance evaluation of a counter-rotating tidal turbine using CFD and to compare its performance with single rotor. The device scale is 10kW and the rotating part consists of two rotors which rotate in opposite direction. Compared with conventional single rotor, the counter-rotating system shows higher power efficiency at high stream velocity but lower efficiency at low stream velocity. The added counter-rotated rotor together helps improve the energy absorption capacity but has influence on the upstream rotor that reduces its performance. In terms of power capture, the designed counter-rotating tidal turbine is more advantageous in high speed tidal condition.

신 흡수제(KoSol-5)를 적용한 0.1 MW급 Test Bed CO2 포집 성능시험 (0.1 MW Test Bed CO2 Capture Studies with New Absorbent (KoSol-5))

  • 이정현;김범주;신수현;곽노상;이동욱;이지현;심재구
    • 공업화학
    • /
    • 제27권4호
    • /
    • pp.391-396
    • /
    • 2016
  • 한전 전력연구원에서 개발한 고효율 아민계 습식 $CO_2$ 흡수제(KoSol-5)를 적용하여 0.1 MW급 Test Bed $CO_2$ 포집 성능시험을 수행하였다. 500 MW급 석탄화력발전소에서 발생되는 연소 배가스를 적용하여 하루 2톤의 $CO_2$를 처리할 수 있는 연소 후 $CO_2$ 포집기술의 성능을 확인하였으며 또한 국내에서는 유일하게 재생에너지 소비량을 실험적으로 측정함으로써 KoSol-5 흡수제의 성능에 대한 신뢰성 있는 데이터를 제시하고자 하였다. 그리고 주요 공정변수 운전 및 흡수탑 인터쿨링 효율 향상에 따른 에너지 저감 효과를 테스트하였다. 흡수탑에서의 $CO_2$ 제거율은 국제에너지기구 산하 온실가스 프로그램(IEA-GHG)에서 제시하는 $CO_2$ 포집기술 성능평가 기준치($CO_2$ 제거율: 90%)를 안정적으로 유지하였다. 또한 흡수제(KoSol-5)의 재생을 위한 스팀 사용량(재생에너지)은 $2.95GJ/tonCO_2$가 소비되는 것으로 산출되었는데 이는 기존 상용 흡수제(MEA, Monoethanol amine)의 평균 재생에너지 수준(약 $4.0GJ/tonCO_2$) 대비 약 26% 저감 된 수치이다. 본 연구를 통해 한전 전력연구원에서 개발한 KoSol-5 흡수제 및 $CO_2$ 포집 공정의 우수한 $CO_2$ 포집 성능을 확인할 수 있었고, 향후 본 연구에서 성능이 확인된 고효율 흡수제(KoSol-5)를 실증급 $CO_2$ 포집플랜트에 적용할 경우 $CO_2$ 포집비용을 크게 낮출 수 있을 것으로 기대된다.

Performance Analysis of a savonius type direct drive turbine for wave energy conversion

  • Zullah, Mohammed Asid;Prasad, Deepak Divashkar;Choi, Young-Do;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.237.2-237.2
    • /
    • 2010
  • Although oscillating water column type wave energy devices are nearing the stage of commercial exploitation, there is still much to be learnt about many facets of their hydrodynamic performance. The techniques of Computational Fluid Dynamics (CFD) are applied to simulate a wave energy conversion device in free surface such as waves. This research uses the commercially available ANSYS CFX computational fluid dynamics flow solver to model a complete oscillating water column system with savonius turbine incorporated at the rear bottom of the OWC chamber in a three dimensional numerical wave tank. The purpose of the present study is to investigate the effect of an average wave condition on the performance and internal flow of a newly developed direct drive turbine (DDT) model for wave energy conversion numerically. The effects of blade angle and front lip shape on the hydrodynamic efficiency are investigated. The results indicated that the developed models are suitable to analyze the water flow characteristics both in the chamber and in the turbine. For the turbine, the numerical results of torque were compared for the all cases. The results of the testing have also illustrated that simple changes to the front wall aperture shape can provide marked improvements in the efficiency of energy capture for OWC type devices.

  • PDF