Search Result 68, Processing Time 0.029 seconds

캡슐 형상이 축열에 미치는 영향 (Effect of Capsule Shape on Heat Storage)

  • 정재동
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.964-971
    • /
    • 2002
  • A numerical investigation of the constrained melting of phase change materials within spherical-like capsule is presented. A single-domain enthalpy formulation is used for simulation of the phase change phenomenon. The solution methodology is verified with the melting process inside an isothermal spherical capsule. Especially, the effect of capsule shape on the heat storage is emphasized. Two shape parameters are considered from the real capsule shape showing good characteristics of heat storage and the effect of these parameters is examined. Early during the melting process, the conduction mode of heat transfer is dominant. Thus the capsule shape with large surface area is desirable. However, the capsule shape with large surface area plays negative role on the strength of buoyancy-driven convection that becomes more important as melting continues.

원추형 하단부 구조를 갖는 캡슐의 하나로와의 양립성시험 (Compatibility Test of the Capsule with Cone Shape Bottom Guide Structures to the HANARO Reactor)

  • 최명환;조만순;주기남;박승재;김봉구;강영환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.444-449
    • /
    • 2004
  • The design modification of bottom guide structures of the instrumented capsule, which is used for the irradiation test in the HANARO reactor, was required because of the trouble of the bottom guide arm's pin during irradiation. The previous structure with 3-pin arms was changed into the cone shape of one body. The specimens of the bottom end cap ring with three different sizes (${\Phi}68/70/72mm$) were designed and manufactured. The out-pile tests for the capsule with previous and new three bottom guide structures were performed in the one-channel flow test facilities. In order to evaluate the compatibility with HANARO and the structural integrity of the capsule, a loading/unloading, a pressure drop, a thermal performance, a vibration, and an endurance test were conducted. From out-pile test results, the capsule with the cone shape bottom guide structures was found to be more stable than the previous structure and the optimized size of the bottom guide structure selected was 70mm in diameter. It is expected that the new bottom guide structures will be applicable to all material and special capsules which will be designed and manufactured for the irradiation tests in the future.

  • PDF

굴곡진 실린더형 캡슐 형상의 축열·방열 성능 해석 (Analysis of the Charging and Discharging Performance of a New Wavy Cylindrical Shape Capsule)

  • 홍상우;이용태;정재동
    • 설비공학논문집
    • /
    • 제26권7호
    • /
    • pp.301-307
    • /
    • 2014
  • This paper presents a numerical study on the constrained melting of a phase change material inside various capsule containers, using water and HDPE (High Density Polyethylene) as a PCM and a capsule material, respectively. The computations are based on an iterative, finite-volume numerical procedure that incorporates a single-domain enthalpy formulation for simulation of the phase change phenomenon. Using the enthalpy method, various capsule configurations, such as a capsule from E company, an isochoric cylinder capsule, an equivalent diameter sphere capsule, and an isochoric sphere capsule, are used to investigate the effect of capsule configurations on the charging and discharging performance. A transient three-dimensional model is used for each case. The simulation results show that the capsule from E company results in a higher melting and solidification rate of the PCM, than the other capsule configurations considered in this research.

캡슐 하단부 구조변경에 따른 압력강하 및 진동특성 (Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures)

  • 최명환;주기남;조만순;김봉구
    • 한국소음진동공학회논문집
    • /
    • 제15권12호
    • /
    • pp.1370-1377
    • /
    • 2005
  • The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change of the bottom structure has an effect on the pressure drop and the vibration of the capsule. The out-pile test to evaluate the structural integrity of the material capsule called 04M-17U was performed by using a single channel and a half core test loop. From the pressure drop test, the optimized diameter of the cone shape's bottom structure which satisfies HANARO's flow requirement (19.6 kg/s) is 71 mm. The maximum displacement of the capsule measured at the half core test loop is lower than 1.0 mm. From the analysis results, it is found that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072 mm. The fundamental frequency of the capsule under water is 9.64 Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's in-core will not occur. Also, the new bottom structure of a solid cone shape with 71 mm in diameter will be applicable to the material and special capsules in the future.

캡슐 하단부 구조변경에 따른 압력강하 및 진동특성 (Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures)

  • 최명환;주기남;조만순;이강희;김봉구
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.782-787
    • /
    • 2005
  • The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change or the bottom structure has an effect on the pressure drop and the vibration of the capsule. The out-pile test to evaluate the structural Integrity of the material capsule called 04M-l7U was performed by using a single channel and a half core test loop. From the pressure drop test, the optimized diameter of the cone shape's bottom structure which satisfies HANARO's flow requirement (19 6 kg/s) is 71 mm. The maximum displacement of the capsule measured at the half core test loop is lower than 1.0 mm. From the analysis results, it is found that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072 mm. The fundamental frequency of the capsule under water is 9.64 Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's In-core will not occur. Also, the new bottom structure of a solid cone shape with 71 mm in diameter will be applicable to the material and special capsules in the future.

  • PDF

STS304L 캡슐의 펄스형 GTA 용접에서 용접변수들이 용접부 형상에 미치는 영향 (The Effect of Welding Parameters on the Weld Shape in Pulsed GTA Welding of a STS304L Stainless Steel Capsule)

  • 이형근;한현수;손광재
    • Journal of Welding and Joining
    • /
    • 제25권5호
    • /
    • pp.64-71
    • /
    • 2007
  • The aim of this paper is to investigate the effects of welding parameters on the weld shape in seal-welding of STS304L capsule for manufacturing a radioisotope source which is widely used in nondestructive testing of metal structures using gamma ray. Pulsed gas tungsten arc (Pulsed GTA) welding is performed for thin cross sectional area of the capsule. Seven welding parameters including current waveform parameters and arc length etc. are selected as main process parameters using design of experiment. The weld shape such as bead width, penetration depth, weld area, aspect ratio and area rate is investigated to assess the effects of welding parameters. As results, the combination of pulse duty/welding speed largely affects on bead width, penetration depth, area and aspect ratio. Finally, it is concluded that the key parameters are the combination of pulse duty/welding speed, base current and arc length, and their optimal conditions are 50%/1.77mm/s, 6.4A and 1 mm.

A New Approach to Obtain Correct and Simplified Equation Applied to Inner Space Assessment for Capsule-like Superstructures

  • Jo, Jihee;Lim, Jong Kuk
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1835-1838
    • /
    • 2013
  • Polypyrrole-Gold (PPy/Au) segment nanowires are prepared using anodized aluminum oxide (AAO) templates and assembled into a curved superstructure. Since the shape of the obtained superstructures can be designed to be capsule-like with inner space for containing materials, and their openings and closures can be controlled with external stimuli, these structures can be useful for a large variety of applications. Inner space of capsule-like superstructures is an important factor for their applications, and the volume of the inner space can be assessed using the generalized equation suggested by J. K. Lim (Bull. Korean Chem. Soc. 33, 2699 (2012)). In this paper, we introduce a new approach to obtain correct and simplified equation without redundant assumption which was used to induce the previous equations, and recalculate the volume of the inner space in the capsule-like superstructure using a new equation.

Magnetic Actuator for a Capsule Endoscope Navigation System

  • Chiba, Atsushi;Sendoh, Masahiko;Ishiyama, Kazushi;Arai, Ken Ichi;Kawano, Hironao;Uchiyama, Akio;Takizawa, Hironobu
    • Journal of Magnetics
    • /
    • 제12권2호
    • /
    • pp.89-92
    • /
    • 2007
  • The authors propose a magnetic actuator for use as a navigation system for capsule endoscopes. The actuator is composed of a capsule dummy, a permanent magnet inside the capsule, and an external spiral structure. The device rotates and propels wirelessly when exposed to an external rotational magnetic field. In this study we measured the effect of the spiral shape on the velocity and thrust force properties. According to our experimental results, the actuator obtained a maximum velocity and thrust force when the spiral angle was set at 45 degrees, the number of spirals was set at 4, and the spiral-height was set at 1-mmf. We also conducted a motion test in the large intestine of a pig placed on a 30 degrees slope. The actuator passed through a 700 mm length of the intestine in about 300 s. The device also managed to travel up and down the 30 degrees slope with no difficulty whatsoever. Our results demonstrate the great potential of this actuator for use as a navigation system for capsule endoscopes.

"서울 1000년 타임캡슐광장" 설계안 (A Design Proposal for the Time Capsule Plaza of Seoul's 1000 Years)

  • 김신원;강현경
    • 한국조경학회지
    • /
    • 제22권3호
    • /
    • pp.163-174
    • /
    • 1994
  • In November of 1994, The Seoul Metropolitan Government celebrates its sixth centennial anniversary of becoming the capital city of Korea. In celebration of this anniversary, the Government decided to construct a plaza and sought design proposals in March of 1994. The authors collaborated on a design for the Time Capsule Plaza Competition and won fourth place among twenty-six entries. In the authors' design, the traditional oriental concept of time resonates within the site through the shape of a clock, a unique planting style, and an "Ancestral Tomb" which has a time capsule inside. The plaza is meant to be a symbol of the passage of time, the cycles of nature, and the repetitive actions of man. As for the spatial composition of the plaza, in accordance with the traditional Korean way of spatial arrangement, the plaza is divided into three parts: entry, primary, and secondary spaces. In reality, the plaza is created with the primary goal of providing modern outdoor space for people to rest and gather through the creation of pleasant environments and the introduction of traditional Korean garden elements.

  • PDF