• 제목/요약/키워드: Capillary limit

검색결과 76건 처리시간 0.023초

PCBs 노출에 따른 넙치(Paralichthys olivaceus) 치어의 신장, 아가미 및 간췌장의 조직학적 반응 (Histological Response of Kidney, Gill and Hepatopancreas of the Juvenile Olive Flounder, Paralichthys olivaceus after PCBs Exposure)

  • 김재원;지정훈;강주찬;이정식;진평
    • 한국수산과학회지
    • /
    • 제36권3호
    • /
    • pp.283-289
    • /
    • 2003
  • The effect on kidney, gill, and hepatopancreas of juvenile olive flounder, Paralichthys olivaceus were investigated by histological method under limit concentration of effulent of PCBs for 60 days. The free surface of epithelial cell layer in the renal tubules of kidney showed a strong positive reaction in alcian blue during all exposure period. There were also observed swelling of hemocyte in glomerulus and macrophage. At 60 days after exposure, epithelium of the renal tubules was fused and some of organism $(20\%)$ showed damage of glomerulus and eosinophlic cell in epithelium of the renal tubules. The phenomena such as the activation and increase of the chloride cell, and swelling of hemocyte in the capillary of gill were observed during all exposure period. At 60 days after exposure, swelling of the gill filament and mucous cell appeared in gill and some of organism $(30\%)$ showed swelling of the gill lamellar. Swelling of hemocyte in the capillary of hepatopancreas was observed and the free surface of epithelial layer of the bile duct showed positive reaction in alcian blue during all exposure period. Degenerated zymogen in the pancreas and swelling of the hepatocyte were occurred at 60 days after exposure.

Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템 (Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode)

  • 이인제;강치중;김용상;김주호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.

Simulation of Ultrasonic Stress During Impact Phase in Wire Bonding

  • Mayer, Michael
    • 마이크로전자및패키징학회지
    • /
    • 제20권4호
    • /
    • pp.7-11
    • /
    • 2013
  • As thermosonic ball bonding is developed for more and more advanced applications in the electronic packaging industry, the control of process stresses induced on the integrated circuits becomes more important. If Cu bonding wire is used instead of Au wire, larger ultrasonic levels are common during bonding. For advanced microchips the use of Cu based wire is risky because the ultrasonic stresses can cause chip damage. This risk needs to be managed by e.g. the use of ultrasound during the impact stage of the ball on the pad ("pre-bleed") as it can reduce the strain hardening effect, which leads to a softer deformed ball that can be bonded with less ultrasound. To find the best profiles of ultrasound during impact, a numerical model is reported for ultrasonic bonding with capillary dynamics combined with a geometrical model describing ball deformation based on volume conservation and stress balance. This leads to an efficient procedure of ball bond modelling bypassing plasticity and contact pairs. The ultrasonic force and average stress at the bond zone are extracted from the numerical experiments for a $50{\mu}m$ diameter free air ball deformed by a capillary with a hole diameter of $35{\mu}m$ at the tip, a chamfer diameter of $51{\mu}m$, a chamfer angle of $90^{\circ}$, and a face angle of $1^{\circ}$. An upper limit of the ultrasonic amplitude during impact is derived below which the ultrasonic shear stress at the interface is not higher than 120 MPa, which can be recommended for low stress bonding.

Optimization of Analytical Procedure for Hydrogen Cyanide in Mainstream Smoke

  • Lee, John-Tae;Kim, Hyo-Keun;Hwang, Keon-Joong;Jang, Gi-Chul;Lee, Jeong-Min;Kim, Ick-Joong
    • 한국연초학회지
    • /
    • 제29권2호
    • /
    • pp.125-131
    • /
    • 2007
  • Hydrogen cyanide(HCN), formed from pyrolysis of various nitrogenous compounds such as protein, amino acids and nitrate in tobacco, is present in both the particulate phase and vapor phase of cigarette smoke. Typically the determination of HCN in cigarette smoke has been done through colorimetric and electrochemical techniques, such as fluorescence spectrometry, UV-spectrophotometry (UV), continuous flow analyzer (CFA), capillary GC-ECD and ion chromatography (IC). Most of these techniques are known to be time-consuming and some of them lack specificity or sensitivity. The available results from both our laboratory and reported literatures for 2R4F Kentucky reference cigarette, smoked under ISO condition, show a relatively wide variation ranging from 100 to 120 ug/cig of HCN. Especially, the precision and accuracy of the analytical results of HCN tend to get worse in low tar cigarettes and under intense smoking condition. In this paper, a more optimized analytical methods than previous ones are suggested. This method shows lower detection limit and has improved precision and accuracy, so it is applicable for wide tar level cigarettes under intense smoking condition as well as under ISO smoking condition. Important features of this method are improved sample collection and quantification systems such as the number of trapping units, volume, temperature and type of trapping solution. To avoid volatilization loss of HCN in analyzing mainstream smoke, it is highly recommended that pH values of trapping solutions should be maintained over 11 and cold traps should be used in collecting mainstream smoke.

GC-MS에 의한 혈중 5-fluorouracil의 정량법 (The Determination of 5-Fluorourasil in Human Plasma by a Gas Chromatography-Mass Spectrometry)

  • 신호상;서배석;오윤숙;박성우
    • 분석과학
    • /
    • 제11권1호
    • /
    • pp.36-41
    • /
    • 1998
  • GC-MS를 이용한 사람의 혈중 5-fluorouracil(5-FU)의 정량법이 연구되었다. 5-FU은 isopropanol-ether(20:80) 혼합용매 10ml로서 추출하였고 pentafluoro-benzylation에 의해 유도체화 하였다. 시료주입은 자동으로 수행하였으며 분리에 사용한 칼럼은 비극성 capillary column이었고 검출은 MSD로 하였다. 위의 조건하에서 내인성 물질들의 방해현상은 없었고 검출한계는 0.5 ml의 혈액시료를 사용하였을 때 3 ng/ml이었으며 추출효율은 80%이상을 나타냈다. 5-FU로 항암치료를 받는 환자의 시료 500개중에 혈중 5-FU의 농도 측정에 적용하였으며 이 방법이 우수한 monitoring법임을 알 수 있었다.

  • PDF

Performance of self-compacting concrete with manufactured crushed sand

  • Benyamina, Smain;Menadi, Belkacem;Bernard, Siham Kamali;Kenai, Said
    • Advances in concrete construction
    • /
    • 제7권2호
    • /
    • pp.87-96
    • /
    • 2019
  • Self-compacting concretes (SCC) are highly fluid concrete which can flow without any vibration. Their composition requires a large quantity of fines to limit the risk of bleeding and segregation. The use of crushed sand rich in limestone fines could be an adequate solution for both economic and environmental reasons. This paper investigates the influence of quarry limestone fines from manufactured crushed sand on rheological, mechanical and durability properties of SCC. For this purpose, five mixtures of SCC with different limestone fines content as substitution of crushed sand (0, 5, 10, 15 and 20%) were prepared at constant water-to-cement ratio of 0.40 and $490kg/m^3$ of cement content. Fresh SCC mixtures were tested by slump flow test, V-funnel flow time test, L-box height ratio, segregation resistance and rheological test using a rheometer. Compressive and flexural strengths of SCC mixtures were evaluated at 28 days. Regarding durability properties, total porosity, capillary water absorption and chloride-ion migration were studied at 180 days. For the two test modes in fresh state, the results indicated compatibility between slump flow/yield stress (${\tau}_0$) and V-funnel flow time/plastic viscosity (${\mu}$). Increasing the substitution level of limestone fines in SCC mixtures, contributes to the decrease of the slump flow and the yield stress. All SCC mixtures investigated achieved adequate filling, adequate passing ability and exhibit no segregation. Moreover, the inclusion of limestone fines as crushed sand substitution reduces the capillary water absorption, chloride-ion migration and consequently enhances the durability performance.

LC/MS/MS를 이용한 sildenafil 및 그 유사체 분석 (Analysis of Sildenafil and its Analogues by LC/MS/MS)

  • 명승운;박서희;조현우
    • 분석과학
    • /
    • 제16권6호
    • /
    • pp.488-498
    • /
    • 2003
  • LC/MS/MS를 이용하여 발기부전 (impotence) 치료제인 sildenafil 및 유사체인 homosildenafil, vardenafil, tadalafil을 분석하는 방법을 확립하였다. 이온화 방법으로는 electrospray ionization (ESI)와 atmospheric pressure chemical ionization (APCI) 방법을 사용하였으며 최대 감도와 재현성을 나타내는 조건을 찾기 위하여 여러 가지 파라미터를 변화시켜서 비교하였다. MRM (multiple reaction monitoring)을 위한 적절한 생성이온 (product ion)을 얻기 위하여 ESI 방법에서는 capillary voltage, cone voltage, extractor, entrance, RF lens를 변화시켰으나 전구이온 (precursor ion)을 제외한 뚜렸한 토막이온 (fragment ion)은 생성되지 않았다. 한편, APCI 방법의 경우 entrance, collision energy, exit, corona voltage, cone voltage, extractor, RF lens, cone gas, desolvation gas를 변화시켰을 때 다른 파라미터들의 변화에 따른 전구이온을 제외한 product ion 생성 패턴의 변화는 감지되지 않고 단지 RF lens 조건의 변화에서 precursor ion을 비롯한 토막이온들의 생성과 더불어 S/N의 증가로 인한 검출 한계의 향상이 나타났다. HPLC에서의 최적 분리 조건과 질량 분석기에서 최대 감도를 나타내는 이동상 조건도 조사되었는데 10 mM ammonium formate (pH 4.8):acetonitrile=70:30 의 등용매 용리조건이 좋은 감도를 나타내었으며, 최적의 방법인 ESI-MRM 방법에서 검출한계 (S/N>5)는 sildenafil은 $0.10{\mu}g/mL$, homosildenafil은 $0.025{\mu}g/mL$, vardenafil은 $0.025{\mu}g/mL$ 그리고 tadalafil은 $0.25{\mu}g/mL$이었다.

소결윅 히트파이프의 제작 및 작동성능 (Manufacturing and Operating Performance of the Heat Pipe with Sintered Wick)

  • 윤호경;문석환;고상춘;황건;최태구
    • 대한기계학회논문집B
    • /
    • 제26권9호
    • /
    • pp.1260-1266
    • /
    • 2002
  • In this study, to make an excellent heat pipe, the manufacturing technology of a sintered wick was investigated. Making a sintered wick is known to be very difficult but it has many advantages. For example, the porosity and pore size can be controlled and the capillary force is great. The mixture of copper and pore former powder was used as a wick material and ceramic-coated stainless steel was used as a mandrel which is necessary for vapor flow. To analyze the feature of the manufactured wick, not only porosity and pore size were measured but also the sintered structure was observed. A heat pipe with sintered wick was manufactured and the performance test of the heat pipe was performed in order to review cooling performance. The performance test results for the 4mm diameter heat pipe with the sintered wick shows the stability since the temperature difference between a evaporator and a condenser of the heat pipe is less than 4.4$^{\circ}C$, and thermal resistance is less than 0.7$^{\circ}C$/W, In the meantime the composite wick that is composed with sintered and woven wire was also examined. The heat transfer limit of the heat pipe with composite wick was enhanced about 51%~60% compare to the one with sintered wick.

액상 효소반응을 이용한 Membrane Strip 형 Cholesterol 측정시스템의 개발 (Development of Membrane Strip Assay System for Lipoprotein Cholesterol Based on Liquid-Phase Enzyme Reactions)

  • 신인수;목락선;장미라;백세환
    • KSBB Journal
    • /
    • 제13권5호
    • /
    • pp.577-584
    • /
    • 1998
  • A sensitive membrane strip assay for plasma lipoprotein cholesterol that can be performed without handling reagents has been investigated. We previously developed an assay system with immobilized enzymes (cholesterol esterase and cholesterol oxidase) on the surfaces of nitrocellulose membrane(1). In such a case, the amount of enzymes present on the membrane was limited by its surface area and, thus, the detection capability was relatively poor (> 50 mg/dL cholesterol). To overcome this problem, we devised a new system with non-immobilized enzymes by placing them within interstitial spaces of a celullose membrane pad in a dry state. Upon contact with sample medium, the enzymes were immediately dissolved and participated in the reactions with cholesterol in a liquid phase. We constructed a user-friendly system consisting of four membrane pads fro sample application, cholesterol decomposition, color development as signal, and medium absorption to invoke a continuous flow (sequential location from the bottom). A sample containing lipoproteins was added into the application pad by capillary action and transferred to the next pad for decomposition. The decomposition pad (namely, enzyme pad) contained a detergent (sodium cholate) for the destruction of lipoprotein particles, the two enzymes for cholesterol decomposition, and a chromogen (3,3'-diaminobenzidine). As a consequence of the enzyme reactions, hydrogen peroxide was produced, and then reacted in the presence of the chromogen with horseradish peroxidase immobilized on the signal generation pad. Finally, a colorimetric signal directly proportional to the cholesterol concentration was produced. The detection limit determined from this system under optimal conditions was at least 2 times lower than of the enzyme-immobilized system.

  • PDF

HF-LPME를 이용한 수용액 시료중의 카페인 분석 (Analysis of caffeine in aqueous sample by hollow fiber-liquid microextraction (HF-LPME))

  • 인치연;김택제;명승운
    • 분석과학
    • /
    • 제21권2호
    • /
    • pp.84-92
    • /
    • 2008
  • 속빈 섬유-액상 미량추출법(hollow fiber-liquid phase microextraction, HF-LPME)과 기체 크로마토그래프/질소-인 검출기(GC-NPD)를 사용하여 사람의 뇨와 여러 가지 음료 중에서 극미량의 카페인을 분석하는 방법을 확립하였다. 수용액 시료로부터 카페인의 양을 측정하기 위해서 속빈 섬유의 길이, 추출용매의 종류, 교반효과, pH 및 염석효과 등 여러 가지 실험적인 파라미터를 변화시켜서 최적의 조건을 확립하고자 하였다. 검정곡선의 회귀계수($r^2$)는 0.9994이상이었으며, 평균 상대 회수율은 102%(n=3)이었으며, 기기검출한계는 2.5 ng/mL, 정량한계는 10 ng/mL이었다. 확립된 HF-LPME 방법은 생물학적 시료, 음식물, 환경시료 중에서 카페인의 농도를 측정하기에 편리하고 정확한 방법이 될 것이다.