• Title/Summary/Keyword: Capillary flow

Search Result 383, Processing Time 0.031 seconds

Back Flushing Behavior of Microfiltration Membrane Fouled by Alumna Colloidal Suspensions (알루미나 현탁액에 의해 오염된 정밀여과막의 역세척 거동)

  • Nam, Suk-Tae;Han, Myeong-Jin
    • Membrane Journal
    • /
    • v.19 no.1
    • /
    • pp.34-46
    • /
    • 2009
  • Effect of backflushing on the membrane fouling for polyethylene capillary membranes was examined by measuring the flux of $Al_2O_3$ colloidal suspensions through the cross flow microfiltration. In the comparison of with and without the application of backflushing, the hydraulic resistance to permeate flow of the suspension was less with backfluslng, but the Increasing rate in permeate resistance was higher. Regardless of backflushing, the cake filtration was dominant at the initial period of filtration with backflushing, being followed by the pore blocking. And at steady state, the fouling mechanism is almost governed by the cake filtration model. On the contrary, the pore blocking preceded the cake filtration in the initial stage of the original membrane before backflushing. And irrespective of backflushing, the ratio of cake filtration to total fouling increased, compared with that fur before backflushing. For the membrane with $0.24{\mu}m$ pore size, the permeate resistance was higher than that of $0.34{\mu}m$ pore size membrane. but the ratio of cake filtration was smaller than that of large pore membrane. In comparing the ratio of each fouling component to the total fouling for the case with backflushing pore blocking was 7.8% and cake filtration was 92.2%. for the case without backflushing, total fouling was composed of 9.6% pore blocking and 90.4% cake filtration.

Effect of Phosphate-to-binder and Water-to-binder Ratio on Magnesia-potassium Phosphate Cement (마그네시아-인산칼륨 시멘트에 대한 인산염 비 및 물-결합재비의 영향)

  • Lee, Kyung-Ho;Yoon, Hyun-Sub;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.3
    • /
    • pp.275-281
    • /
    • 2017
  • This study examined the effect of water-to-binder ratio (W/B) and phosphate-to-binder ratio (P/B) on the flow, setting time, compressive strength development, and pH variation of magnesium-potassium phosphate composites, MKPC mortars. Ten mortars mixtures were prepared with the W/B varying from 20% to 40% at each P/B of 0.3 or 0.5. The hydration products and microstructural pore distribution of the MKPC pastes were investigated using X-ray diffraction (XRD), scanning electron microscope (SEM) and mercury intrusion porosimetry (MIP). The initial flow and setting time of MKPC mortars tended to decrease with an increase of P/B, indicating that the final setting time was shortened by approximately 24% when P/B increased from 0.3 to 0.5. The slope of the early-strength development measured in the MKPC mortars was considerably higher than that of cement concrete specified in code provisions. For obtaining a relatively good 28-day strength (above 30 MPa) and a near neutral pH (below 9.0) in MKPC mortars, the P/B and W/B need to be selected as 0.5 and 30%, respectively. The strubite-K crystal increased with the increases of P/B and W/B, which leads to the decrease of the macro-capillary pores.

A acupuncture therapy literature study on the hemorrhoids and hemorrhoids complicated by anal fistula (치창(痔瘡)과 치루(痔漏)에 대한 침구학적(鍼灸學的) 문헌고찰(文獻考察))

  • Song, Won-sub;Lee, Byung-ryul;Lee, Hyun;Chae, Sang-jin
    • Journal of Acupuncture Research
    • /
    • v.20 no.1
    • /
    • pp.131-143
    • /
    • 2003
  • Objective : The purpose of this study is to arrange the literature about acupuncture therapy on the hemorrhoids and hemorrhoid complicated by anal fistula. Methods : We arrange Huang Di Nei Jing and fifteen kinds of literature about the hemorrhoids and hemorrhoid complicated by anal fistula. Results : 1. The cause of hemorrhoids are overfatigue, overeating, imbalance of stool(const-ipation or diarrhea), uncontrol sexual excess or abstinence, pathgenic factors of wetness, heat, wind, dry, fire, chronical hemorrhoids that has not been treated, and general weakness. 2. Symptom of hemorrhoids is that skin is projected form the nine holes or varicose extension to become hemorrhoid. Hemorrhoids is small nodosity that projected on the anal inter or outer region, and hemorrhoid complicated by anal fistula is pus which comes out form one or some fistula on the anal around inter and outer region. 3. Therapy method of hemorrhoid and hemorrhoid complicated by anal fistula are elimination pathological heat from blood, promote blood flow to remove blood stasis, cold in nature and purge away fire, remove heat form the blood, promote blood flow to remove blood stasis, cold in nature and purge away fire, remove heat from the blood and eliminate dampness, tonify the spleen and replenish Ki, dispel wind and alleviate pain and so forth. Therapy method of hemorrhoid is to give the first consideration to relieve blood: eliminating pathological heat form blood complicated by anal fistula is to tonify the blood first, than after that eliminating pathological heat form blood. About external method are method of fumigation, method of ointment, method of close with medicine, necrotizing method and also operation(injection, bind etc.)was used for treatment. 4. The prescription are Gurgak-hwan, Wypi-hwan, Gunggyi-tang, Jingyochangchul-tang, Jingyobangpung-tang, Mokhyangbinrang-hwan, Ochi-san, Gamihyanso-san, Jojang-hwan, Sinyung-hwan used frequently. 5. food taboo on patient's diet of the hemorrhoid and hemorrhoid complicated by anal fistula are raw grain, cold or dampness food, alcohol, hot food, Singiberis rhizoma recens, Cinnamomi ramulus. 6. Acupuncture therapy on the hemorrhoid and hemorrhoid complicated by anal fistula are, in the first stage eliminating pathological heat form blood and eliminate dampness, and in the long term eliminate dampness, promote and remove meridian energy, remove that form the intestines, dispel channels and collaterals. 7. Acupuncture points at B2, CV1, B58, B36, B56, Sp5, S30, B25, B54, GV1, GV20, L6, B40 used frequently for the acupuncture therapy, and acupuncture point at GV4, GV1, B30, hemorrhoidal point used form moxibustion. Reduction blood at B40 and blue capillary of Sp9 and acupuncture Chungbaek, Ki-gack, Ki-jung, Ki-mun(Dongsh Kihyel) makes the treatment very effective.

  • PDF

Flux Decline Behavior in Cross-flow Microfiltration of Inorganic Colloidal Suspensions (무기 콜로이드 현탁액의 십자류 정밀여과에 의한 투과유속의 감소거동)

  • Nam Suk-Tae;Han Myeong-Jin
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.338-348
    • /
    • 2005
  • The permeate flux decline on microfiltration capillary membrane operation was investigated with inorganic colloidal solutions. The permeate flux of the alumina solution is two times higher in average than that of the bentonite solution. The flux decline with increase in operation time was less in the alumina solution than in the bentonite solution. The rate of initial flux decline until 10 min was higher on the bentonite solution over the alumina solution. The decline in permeate flux was due to both the cake formation and the pore blocking. The latter effect was higher in the operation of the bentonite solution. In comparing the ratio of each fouling component to the total fouling fur the $1.0\;kg_f/cm^2$ TMP condition, complete blocking was $9.35\%$, standard blocking was about $6.82\%$ and cake filtration was $83.83\%$, respectively. With the increase in cross flow velocity, the permeate flux increased by $6.0\%$ for the alumina solution and by 14.0 for the bentonite solution. With the increase in average pore size fromm $0.24\;{\mu}m\;to\;0.34\;{\mu}m$, the permeate flux increases 1.61 times for the alumina solution and 1.76 times far the bentonite solution.

Animal Experiment of the Pneumatic Ventrivular Assist Device (공압식 심실 보조기의 동물실험)

  • Park, Seong-Sik;Kim, Sam-hyun;Seo, Pil-won;Choi, Chang-hyu;Lee, Sang-hoon;Lee, Hyuk-soo;Hwang, Seung-ok;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.32 no.12
    • /
    • pp.1065-1077
    • /
    • 1999
  • Background : Ventricular assist devices(VADs) are being used for patients in postcvardiotomy cardiogenic shock status bridge to cardiac transplant settings and in post-myocardial infarction cardiogenic shock. The VAD which was developed at the Deparment of medical engineering in Dankook University College of Medicine was a pneumatically driven device and can maintain pulsatile flow. The goal of this study is to develop animal experimental models using the VAD and to clarify the reliability and hemodynamic property adequacy of end organ perfusion durability and severity of thrombotic-hemolytic tendency of the device. Material and Method : The pneumatic VAD was applied to 8 adult female lambs, We examined some hemodynamic parameters such as arterial blood pressure pulmonary capillary wedge pressure(pcwp) pulmonary artery pressure(PAP) left atrial pressure hour urine output cardiac index VAD flow EKG to determine the reliability of the VAD and hemodynamic compatibility of the experimental animals within 24 hours of experiment. We also observed the end organ perfusion durability of the VAD and thrombotic-hemolytic property of the VAD after 24 hours of VAD insertion. Result: We could monitor all hemodynamic parameters including pcwp PAP cardiac index EKG, adn hour urine as true clinical settings. We observed that the reliability of the VAD was excellent and the hemodynamic property of the experimental animal and end organ perfusion were adequate within 24 hours of experiment. In four lambs surviving 24 hours after insertion the reliability of the VAD and end organ perfusion were excellent and no thrombotic-hemolytic tendency was noted. However after 15 days of experiment the diaphragm of the VAD was torn and it was recommende that the durability of the VAD should be extended. Conclusion : e conclude that the pneumatic VAD developed at Dankook University Biomedical Engineering has good hemodynamic property and low thromboembolic tendency and presents adequate end organ perfusion but we noted that the durability of the device should be expanded further. It will be possible to do more reliable experiment in the future according to the animal experimental method developed in this study especially with the heart failure models.

  • PDF

Characteristics of Mine Liner According to the Replacement Ratio of Nano-Silica and Silica-Fume (나노실리카 및 실리카흄 대체율에 따른 차수재의 특성)

  • Kang, Suk-Pyo;Lee, Hee-Ra;Kang, Hye-Ju;Nam, Seong-Young;Kim, Chun-Sik
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.1
    • /
    • pp.66-73
    • /
    • 2019
  • Approximately 80% of the mines are vacated or abandoned mines and are mostly left without suitable environmental treatment facilities. In the area around the abandoned mine site, problems such as drainage of acidic city drainage and leakage of leachate occur, and ground subsidence caused by this can cause a safety accident due to sink hole occurrence. In this study, flow, compressive strength, water uptake, pore and hydration characteristics were investigated to investigate the basic properties of liner and cover material based on the replacement ratio of nano silica and silica fume in the existing blast - furnace slag fine powder. As a result, as the substitution ratio of nano silica and silica fume increased, the flow and compressive strength of nano silica specimens increased and the absorption rate decreased. In the case of pore characteristics, the amount of pores decreased as the substitution ratio of nano silica and silica fume increased. Especially, the capillary porosity of 10-1,000 nm diameter decreased. Ray diffraction analysis and SEM measurement showed that the peak positions of the hydration products were almost the same when compared with the 5% alternative test samples of Plain and silica fume.

A Thermo-Hydro-Mechanical Coupled Numerical Simulation on the FE Experiment: Step 1 Simulation in Task C of DECOVALEX-2023 (Mont Terri FE 실험 대상 열-수리-역학 복합거동 수치해석: DECOVALEX-2023 Task C 내 Step 1 수치해석 연구)

  • Taehyun, Kim;Chan-Hee, Park;Changsoo, Lee;Jin-Seop, Kim
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.518-529
    • /
    • 2022
  • In Task C of the DECOVALEX-2023 project, nine institutes from six nations are developing their numerical codes to simulate thermo-hydro-mechanical coupled behavior for the FE experiment performed at Mont Terri underground rock laboratory, Switzerland. Currently, Step 1 for comparing the simulation results to field data is the ongoing stage, and we used the OGS-FLAC simulator for a series of numerical simulations. As a result, temperature increase depending on the heating hysteresis was well simulated, and saturation variation in the bentonite depending on phase change was observed. However, due to the suction overestimation, relative humidity and temperature change in the bentonite and the pressure variation in the Opalinus clay showed a difference compared to the field data. From the observation, it is confirmed that the effect of the bentonite capillary pressure is dominant to the flow analysis in the disposal system. We further plan to draw improved results considering tunnel support material and accurate initial water pressure distribution. Additionally, the thermal, hydrological, and mechanical anisotropy of the Opalinus clay was well simulated. From the simulation results, we confirmed the applicability of the OGS-FLAC simulator in the disposal system analysis.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

Bronchial Responsiveness in Patients with Mitral Valvular Heart Disease (승모판 심장질환 환자에서 기관지 반응성에 대한 연구)

  • Kim, Ho-Cheol;Kim, Min-Gu;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.752-759
    • /
    • 1995
  • Background: Bronchial asthma is characterized by noctunal dyspnea, cough and wheezing because of airway hyperresponsiveness to nonspecific stimuli. These symptoms and signs are also observed in patients with congestive heart failure. Therefore, this is so called "cardiac asthma". There are lots of experimental and clinical datas to suggest that airway dysfunctions occur in acute and chronic congestive heart failure. However, it is still controversial whether bronchial hyperresponsiveness is present in patients with congestive heart failure. To assess whether bronchial hyperresponsiveness is present in patients with congestive heart failure and to demonstrate the relationship between bronchial responsiveness and vascular pressure, we performed methacholine provocation test in 11 patients with mitral valvular heart disease. Methods: All patients were in the New York Heart Association functional class II and treated continuously with digoxin and/or dichlozid and/or angiotensin converting enzyme inhibitor except one patient. All patients were undergone right and left side heart catheterization for hemodynamic measurements. A 20 percent fall of peak expiratory flow rate were considered as positive response to methacholine provocation test. Results: 1) Only one patient who has normal pulmonary artery pressure, pulmonary capillary wedge pressure, cardiac index was positive in methacholine provocation test. 2) Their mean pulmonary artery pressure, pulmonary capillary wedge pressure were $21.72{\pm}9.70mmHg$, $15.45{\pm}8.69mmHg$ respectively which were significantly higher. Conclusion: It is speculated that in stable congestive heart failure patients, bronchial responsiveness as assessed by methacholine provocation test may not be increased.

  • PDF