• Title/Summary/Keyword: Capillary Pressure

Search Result 306, Processing Time 0.027 seconds

Benign Lymphnode Hyperplasia hyaline-vascular type in pulmonary hilum: One Case Report (폐문부에 발생한 양성 임파절 비대증 1 치험예)

  • 이두연
    • Journal of Chest Surgery
    • /
    • v.10 no.1
    • /
    • pp.44-48
    • /
    • 1977
  • Benign hyperplasia of hilar lymph glands is rare. Most of the lesions were intrathoracic cavity. The lesions were discovered most often on routine roentgenograms of the chest or because. of pressure symptoms or the presence of a palpable mass if outside the thorax. Diagnosis is. made after removal of gland, a procedure which may also have therapeutic value. They have been divided into 2 histol0gic types: the hyaline-vascular lesions, which were, most numerous, were characterized by small hyaline-vascular follicles and interfollicular capillary proliferation ;the plasma cell lesions were characterized by large follicles with! intervening sheets of plasma cells. We experienced one case of benign hyperplasia of lymph gland in left hilum, which were. most numerous, characterized by small hyaline-vascular follicles and interfollicular capillary proliferation-hyaline-vascular type. This 29 years old male patient was treated by right upper lobectomy with excision of lesion. The postoperative courses was uneventful.

  • PDF

A Study on the Characteristics of an Oscillating Fluidic Atomizer

  • Kim, K.H.;Kiger, K.;Lee, W.
    • Journal of ILASS-Korea
    • /
    • v.11 no.2
    • /
    • pp.105-112
    • /
    • 2006
  • A unique feature of fluidic atomizers is that the nozzle geometry produces a thin capillary Jet which is forced to oscillate on a 2-dimensional plane through the use of a passive feedback mechanism. The objective of the current work is to characterize the influence of the stagnation pressure at the nozzle exit, jet oscillation and stretching on the breakup properties of the capillary ligament. To achieve this, shadow graph technique is used to measure size, shape, velocity and the number density of the droplets as a function of the position within the spray fan. The breakup length, defined as the radial distance from the breakup point, is analyzed as a function of the non-dimensional parameters. Finally, a kinematic model is developed to simulate the breakup of the oscillating jets at low stagnation pressures. Using the existing jet breakup theories, the model is used to predict the size and diameter distribution of the droplets after primary atomization.

  • PDF

Characteristics of Shear-Thinning Fluid Viscosity under Traversal Vibration (진동장에서의 전단박화 유체 점도의 특성 연구)

  • Ku Yun-Hee;Lee Ji-Hyung;Shin Sehyun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.317-320
    • /
    • 2002
  • The effect of vibration on the viscosity of a shear-thinning fluid was investigated with a newly designed pressure-scanning capillary viscometer. The viscometer was designed to measure non-Newtonian viscosity continuously over a range of shear rates at a time. Low frequency vibration was applied perpendicularly to the direction of the flow. The effect of the transversal vibration was investigated for both Newtonian fluids and non-Newtonian fluids. The experimental results showed that the vibration had no effect on the viscosity of the Newtonian fluids. However, the vibration caused a significant reduction of the shear-thinning fluid viscosity. The viscosity reduction was strongly dependent on both vibration frequency and shear rate. In addition, the viscosity reduction was affected by the amplitude of vibration, and, the bigger amplitude applied, the more viscosity reduction occurred.

  • PDF

Sound Propagation through the Diesel Particulate Filter (DPF) (디젤 매연여과기 (DPF) 내에서의 음향전파)

  • Choi, Won-Yong;Ih, Jeong-Guan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.152-155
    • /
    • 2005
  • Diesel particulate filter (DPF) is comprised of a number of capillary tubes enclosed by porous ceramic wails, shaped like a plugged duct. Hot gas flows through the DPF along with the exhaust noise from Diesel engine. Based on previous works on the sound propagation through DPF, in this study, losses at entrance, exit, and ceramic walls are considered and the gradients in temperature and flow velocity are considered. Transfer matrix at entrance, monolith, and exit parts are obtained by employing the segmental approach in analyzing the sound propagation through DPF. The predicted transmission loss agrees very well with the empirical one, which is measured by the improved method with correction terms.

  • PDF

Safety Design of the Loop Heat Pipe (LHP) by the Hazard Analysis

  • Tanaka, Kiyoshi
    • International Journal of Safety
    • /
    • v.9 no.1
    • /
    • pp.54-57
    • /
    • 2010
  • The LHP uses the capillary head instead of the mechanical pump to transfer the fluid. It does not have any moving parts and transfer the fluid by the capillary head between the vapor and liquid interface of the wick like a heat pipe (HP). Moreover, vapor and liquid flows in the same direction. It can reduce the loss of the pressure in the wick (very short wick in the evaporator) and can transfer large heat over long distance compared with HP. It is necessary that we do the hazard analysis that is a part of the safety design, for the benefit of eliminating and inhibit the hazard. In this paper, we describe the hazard analysis of LHP.

Analysis of Pumping Performance of a Helical Drag Pump Using the Diffusion Equation (확산방정식을 이용한 헬리컬 드래그펌프의 성능해석)

  • Heo, Joong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.5
    • /
    • pp.382-391
    • /
    • 2008
  • A simple analytical model of rarefied channel flow is developed to predict the compression ratio in a helical drag pump. If the surface velocity is zero, the model reduces to a capillary leaks. Predictions of our model agree well with the Knudsen's data for capillary leaks in transition flow, in addition to giving a good account of the Knudsen minimum. Also, the present results are compared with experimental data, and good agreement is obtained over the entire pressure range from molecular to slip flow.

A Study of the Micor Mechanical System by Using the Magnetic Fluid (자성유체를 개입한 Micro Mechanical System에 관한 연구)

  • Kim, Dong-Wook;Kim, Nam-Gyun;Kim, Bu-Gil;Yuhta, Toshio
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.147-153
    • /
    • 1993
  • In this paper, we studied about the micro pressure transmission system using fluid. For the investigation of feasibility of microhydraulic system, the hydraulic characteristics were examined by using the capillary tube system and the micro cylinder system that consists of a rod and a micro capillary tube. A new hydraulic micro actuator using magnetic fluid and an external magnetic field was also investigated. The results showed that our microhydraulic system has the possibility of power transmission in arbitrary directions.

  • PDF

Flow Near the Meniscus of a Pressure-Driven Water Slug in Microchannels

  • Kim Sung-Wook;Jin Song-Wan;Yoo Jung-Yul
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.710-716
    • /
    • 2006
  • Micro-PIV system with a high speed CCD camera is used to measure the flow field near the advancing meniscus of a water slug in microchannels. Image shifting technique combined with meniscus detecting technique is proposed to measure the relative velocity of the liquid near the meniscus in a moving reference frame. The proposed method is applied to an advancing front of a slug in microchannels with rectangular cross section. In the case of hydrophilic channel, strong flow from the center to the side wall along the meniscus occurs, while in the case of the hydrophobic channel, the fluid flows in the opposite direction. Further, the velocity near the side wall is higher than the center region velocity, exhibiting the characteristics of a strong shear-driven flow. This phenomenon is explained to be due to the existence of small gaps between the slug and the channel wall at each capillary corner so that the gas flows through the gaps inducing high shear on the slug surface. Simulation of the shape of a static droplet inside a cubic cell obtained by using the Surface Evolver program is supportive of the existence of the gap at the rectangular capillary corners. The flow fields in the circular capillary, in which no such gap exists, are also measured. The results show that a similar flow pattern to that of the hydrophilic rectangular capillary (i.e., center-to-wall flow) is always exhibited regardless of the wettability of the channel wall, which is also indicative of the validity of the above-mentioned assertion.

Enantioseparation and Determination of Sibutramine in Pharmaceutical Formulations by Capillary Electrophoresis

  • Zhu, Hongmei;Wu, Enqi;Chen, Jianbo;Men, Chuvan;Jang, Yu-Seon;Kang, Won-Ku;Choi, Jung-Kap;Lee, Won-Jae;Kang, Jong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.1496-1500
    • /
    • 2010
  • Sibutramine enantiomers were separated successfully by capillary zone electrophoresis using substituted cyclodextrins as chiral selectors. The effects of cyclodextrin concentration, pH, voltage, buffer type, and electrolyte concentration on the migration time and resolution of enantiomers were examined. Separation of sibutramine enantiomers on an unmodified fused silica capillary (total length, 54 cm; effective length, 45 cm) was achieved using a mixed buffer of 20 mM phosphate/10 mM citrate containing either 5 mM methyl-${\beta}$-cyclodextrin (pH 4.3) or 5 mM carboxymethyl-${\beta}$-cyclodextrin (pH 6.5). Samples were injected with a pressure of 50 mbar for 5 s and were detected at a wavelength of 223 nm. The established method showed good precision and accuracy, with intra- and inter-day variations of less than 2.9 and 4.7%, respectively, and recoveries of 95.7 - 103.8%. The stability constants of (R)- and (S)-sibutramine demonstrated that the resolution of sibutramine enantiomers was attributable primarily to the difference in stability constants. When this optimized method was applied to the determination of sibutramine enantiomers in commercial drug formulations, it proved to be economical and convenient, affording sufficient accuracy, precision, and reproducibility as well as sensitivity and selectivity.

Chloride Attack Resistibility of Marine Concrete under Pressure (압력을 받는 해양콘크리트의 염해저항성)

  • Kim, Gyeong-Tae;Kim, Gyu-Yong;Lee, Sang-Kyu;Hwang, Eui-Chul;Son, Min-Jae;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.52-53
    • /
    • 2018
  • As a result of exposing the concrete at 1 and 6 atm in order to evaluate the salt resistance of the pressurized marine concrete, the pressure resulted in promoting the chloride ion penetration of the concrete. Particularly, the amount of water soluble chloride in the surface area tends to increase rapidly, and this cause is considered to be highly correlated with the size of the capillary pores of the concrete. On the other hand, the blending of blast furnace slag was effective to increse chloride attack resistibility even under the pressure.

  • PDF