• 제목/요약/키워드: Capillary Limitaion

검색결과 1건 처리시간 0.019초

축방향 사다리꼴 그루브 히트파이프의 열성능에 대한 실험적 연구 (Experimental Study of Thermal Performance of Heat Pipe with Axial Trapezoidal Grooves)

  • 서정세;이운
    • 대한기계학회논문집B
    • /
    • 제27권4호
    • /
    • pp.407-414
    • /
    • 2003
  • Analysis and experiment are performed to investigate the thermal performance of a heat pipe with axial grooves. The heat pipe was designed in a 6.5 mm I.D., 17 axial trapezoidal grooves. 1000 mm long tube of aluminium, and ammonia as working fluid. A mathematical equations fur heat pipe with axial grooves is formulated to obtain the capillary limitation on heat transport rate in a steady state. As a result, heat transport factor of heat pipe has the maximum at the operating temperature of 293K in 0m elevation. As the elevation of heat pipe increases. the heat transport factor of the heat pipe is reduced markedly, comparing with that of horizontal elevation of the heat pipe. It may be considered that such behavior of heat pipe is caused by the working fluid swarmed back to the condenser port due to gravity force and supercooled by a coolant of heat exchanger. Analytical results of heat transport factor are in a good agreement with those of experiment.