• 제목/요약/키워드: Capacity margin ratio

검색결과 21건 처리시간 0.026초

A SYSTEM DESIGN AND ANALYSIS FOR SATELLITE COMMUNICATION LINK

  • Chung, Tae-Jin;Eun, Jong-Won
    • Journal of Astronomy and Space Sciences
    • /
    • 제17권2호
    • /
    • pp.257-266
    • /
    • 2000
  • A satellite RF communication link is analyzed based on a simple fundamental equations by systematic approach in this paper. The number of variables related to a design and analysis of satellite RF link is often a dozen or more, thus it is a tedious and time-consuming task. With the given input data, the important parameters are calculated step by step and three communication characteristics such as communication channel capacity, carrier-to-noise ratio(CNR) at the satellite and ground station are analyzed. It gives very useful information to the system engineers for designing and analyzing the overall satellite communication system in the conceptual design phase.

  • PDF

증분동적해석을 통한 비보강 조적벽식 건물의 내진성능 평가 (Seismic Performance Assessment of Unreinforced Masonry Wall Buildings Using Incremental Dynamic Analysis)

  • 권기혁;김만회;김형준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권3호
    • /
    • pp.28-39
    • /
    • 2013
  • 비보강 조적벽체를 이용한 저층 건축물은 국내에 가장 흔히 볼 수 있는 주거형태이지만, 비보강 조적벽체는 높은 횡강성에 비하여 연성능력 부족 등의 이유로 지진으로부터 구조적 피해를 피하기 힘든 횡력저항시스템으로 알려져 있다. 하지만, 국내 비보강 조적벽체 전단강도와 전단강성에 대한 실험적 연구는 부족한 편이며, 실제 지진이 발생했을 비보강 조적벽체를 횡력저항요소로 사용하는 건축물의 내진성능에 대한 연구는 상대적으로 부족한 실정이다. 이로 인하여 국내 비보강 조적벽체의 특성을 반영하고 있다고 볼 수 없는 FEMA 356에서 제시하고 있는 비보강 조적벽체의 전단강도와 강성을 준용하여 사용하고 있다. 본 연구에서는 우선 FEMA 356에서 제시하고 비보강 조적벽체의 전단강도와 강성을 실험결과와의 차이에 대해 기술하고, 이 차이가 현황조사와 실험데이터를 바탕으로 결정한 표본 비보강 조적조 건축물의 내진성능에 미치는 영향과 경과년수에 따른 영향을 증분동적해석을 이용하여 계산된 붕괴여유비와 구조성능의 불확실성을 표현하는 베타값을 이용하여 분석하였다. 해석결과를 통하여 FEMA 356에 의한 전단강도와 강성을 사용할 경우 조적조 건축물의 붕괴여유비와 베타값을 과소평가하는 것으로 나타났다. 하지만, 두 경우 모두 국내 내진설계기준에서 제시하는 성능기준을 만족하지 않는 것으로 나타났으며, 경과연수가 클수록 이런 현상은 뚜렷해지며, 30년 이상 경과된 조적조 건축물은 2400년 재현주기의 지진에 붕괴확률이 약 90%에 도달하는 것으로 나타났다.

복합 잡음환경에서 디지털 가입자 회선의 SNR 마진 성능에 관한 연구 (A Study on the SNR Margin Performance of Digital Subscriber Line in Complex Noises Environment)

  • 김용환;조평동;박상준;강영흥
    • 한국통신학회논문지
    • /
    • 제27권9C호
    • /
    • pp.829-835
    • /
    • 2002
  • 디지털 가입자 회선(DSL)의 채널 용량에 가장 크게 영향을 미치는 내부 잡음원으로서 근단누화(NEXT) 및 원단누화(FEXT) 잡음을 들 수 있지만, 외부 잡음원인 임펄스 영향에 의해 DSL 성능 열화가 야기되므로 송수신 설계에 있어 이들 잡음원들의 복합적인 성능 분석이 절실히 요구되고 있다. 이에 본 연구에서는 테스트 신호 Cook 펄스를 Middleton의 Class A 임펄스 신호로 모델화 한 후, 가우스 잡음, NEXT 및 FEXT 잡음, 임펄스 잡음의 복합 잡음환경에서 DMT 신호의 SNR 마진을 계산하여 평가를 행하였다. 그 결과 업링크상에서는 루프전송길이에 따른 전송속도의 열화는 크지 않으며, 잡음의 특성에 의해 전송속도가 제한되지만, 다운링크상에서는 루프 전송길이 뿐만 아니라 잡음특성등에 의한 복합적인 열화가 두드러짐을 알 수 있다. 결론적으로 본 연구의 결과는 임펄스 잡음을 포함한 복합환경에서의 ADSL 성능기준을 설정하는데 주요 자료로서 활용될 수 있을 것이다.

550 MPa 급 철근을 적용한 낮은 철근콘크리트 벽체의 전단강도를 위한 반복하중 실험 (Cyclic Loading Test for Shear Strength of Low-rise RC Walls with Grade 550 MPa Bars)

  • 박홍근;이재훈;신현목;백장운
    • 콘크리트학회논문집
    • /
    • 제25권6호
    • /
    • pp.601-612
    • /
    • 2013
  • 거대한 벽체를 사용하는 원전구조물의 건설에서, 시공성과 경제성향상을 위해 벽체의 전단철근으로 사용되는 고강도 철근의 사용이 필요하다. 이 연구에서는, 550 MPa 급 철근을 사용한 낮은 벽체(형상비 1.0)의 전단내력과 변형능력을 검증하기 위해 벽체의 반복하중재하 실험이 수행되었다. 실험 변수는 수평철근의 항복강도(550 MPa 급, 420 MPa 급), 콘크리트 압축강도(46 MPa, 70 MPa), 수평/수직전단철근비, 횡구속후프의 여부, 벽체의 단면형상, 파괴모드(휨항복 전 또는 후 전단파괴)였다. 실험결과를 420 MPa 급 철근을 사용한 벽체, 그리고 현행설계기준에 의한 예측강도와 비교하였다. 실험 결과로부터 550 MPa 급 철근을 사용한 벽체의 전단강도가 420 MPa 급 철근을 사용한 벽체의 전단강도에 비해 안전여유가 조금 감소하였으나 비슷함을 보였다. ACI 349 전단강도식은 550 MPa 급 철근을 사용한 벽체를 과소평가하였으며, 휨 항복의 실험체의 경우 큰 변형능력을 보였다. 이 결과는 ACI 349 규정이 550 MPa 급 철근을 사용한 낮은 벽체(형상비 1.0)의 내진설계에 안전하게 적용될 수 있음을 가리킨다.

Cost-Effective Transition to 40 Gb/s Line Rate Using the Existing 10 Gb/s-Based DWDM Infrastructure

  • Lee, Sang-Soo;Cho, Hyun-Woo;Lim, Sang-Kyu;Lee, Dong-Soo;Yoon, Kyeong-Mo;Lee, Yong-Gi;Kim, Kwang-Joon;Ko, Je-Soo
    • ETRI Journal
    • /
    • 제30권2호
    • /
    • pp.261-267
    • /
    • 2008
  • In this paper, we propose and demonstrate a cost-effective technique to upgrade the capacity of dense wavelength division multiplexing (DWDM) networks to a 40 Gb/s line rate using the existing 10 Gb/s-based infrastructure. To accommodate 40 Gb/s over the link optimized for 10 Gb/s, we propose applying a combination of super-FEC, carrier-suppressed return-to-zero, and pre-emphasis to the 40 Gb/s transponder. The transmission of 40 Gb/s DWDM channels over existing 10 Gb/s line-rate long-haul DWDM links, including $40{\times}40$ Gb/s transmission over KT's standard single-mode fiber optimized for 10 Gb/s achieves successful results. The proposed upgrading technique allows the Q-value margin for a 40 Gb/s line rate to be compatible with that of 10 Gb/s.

  • PDF

Seismic performance assessment of the precast concrete buildings using FEMA P-695 methodology

  • Adibi, Mahdi;Talebkhah, Roozbeh
    • Structural Engineering and Mechanics
    • /
    • 제82권1호
    • /
    • pp.55-67
    • /
    • 2022
  • The precast reinforced concrete frame system is a method for industrialization of construction. However, the seismic performance factor of this structural system is not explicitly clarified in some existing building codes. In this paper, the seismic performance factor for the existing precast concrete building frame systems with cast-in-situ reinforced shear walls were evaluated. Nonlinear behavior of the precast beam-column joints and cast-in-situ reinforced shear walls were considered in the modeling of the structures. The ATC-19's coefficient method was used for calculating the seismic performance factor and the FEMA P-695's approach was adopted for evaluating the accuracy of the computed seismic performance factor. The results showed that the over-strength factor varies from 2 to 2.63 and the seismic performance factor (R factor) varies from 5.1 to 8.95 concerning the height of the structure. Also, it was proved that all of the examined buildings have adequate safety against the collapse at the MCE level of earthquake, so the validity of R factors was confirmed. The obtained incremental dynamic analysis (IDA) results indicated that the minimum adjusted collapse margin ratio (ACMR) of the precast buildings representing the seismic vulnerability of the structures approximately equaled to 2.7, and pass the requirements of FEMA P-695.

Earthquake loss assessment framework of ductile RC frame using component- performance -based methodology

  • Shengfang Qiao;Xiaolei Han;Hesong Hu;Mengxiong Tang
    • Structural Engineering and Mechanics
    • /
    • 제91권4호
    • /
    • pp.369-382
    • /
    • 2024
  • The earthquake loss assessment framework of ductile reinforced concrete (or RC) frame using component-performance -based methodology was studied in this paper. The elasto-plastic rotation angle was used as the damage indicator of structural component, and the damage-to-loss model was proposed on the basis of the deformation indicator of structural component. Dynamic instability during incremental dynamic analysis was taken as collapse criterion, and column failure was taken as criterion that structure has to be demolished. Expected earthquake losses of low-rise, mid-rise and high-rise RC frames were discussed. The expected earthquake loss encompassed collapse loss, demolition loss and repair loss. Furthermore, component groups of RC frame were divided into structural components, nonstructural components and rugged components. The results indicate that ductile RC frame is more likely to be demolished than collapse, especially in low-rise and mid-rise RC frames. Furthermore, the less collapse margin ratio the structure has, the more demolition probability the structure will suffer under rare earthquake. The demolition share of total earthquake loss might be more prominent than repair share and collapse share in ductile RC frame.

발·송전설비 통합성을 고려한 전력계통계획 전산모형 프로그램 개발 (Development of Transmission Expansion Planning Optimization Software Considering Integration of Generation and Transmission Facilities)

  • 허돈;정해성;유헌수;조강욱
    • 조명전기설비학회논문지
    • /
    • 제24권2호
    • /
    • pp.16-26
    • /
    • 2010
  • 본 논문에서 제안하는 전력계통계획 방법론은 계통계획이 신규 자원의 수익에 영향을 미칠 수 있다는 인식 하에 발전 및 송전 투자 결정에 관한 상호 작용을 반영하고, 이것으로 인하여 설비 투자자 및 전력계통계획자의 목적을 동시에 고려할 수 있게 된다. 이러한 관점에서 본 논문은 혼합정수계획 모형에 기초한 전력계통계획 전산모형 프로그램을 개발하고자 한다. 이 소프트웨어는 설비예비율, 발전원별 비율,순동예비력 양, 에너지 및 연료제약 조건, 송전선로 사고 및 손실, 파이 분기 등의 기술적 제약조건을 만족하면서 신규 발전설비, 송전선로, 변전소의 용량뿐만 아니라 건설 시기와 장소를 결정하도록 설계되어 있다. 최종적으로 간단한 Garver 계통을 통하여 본 논문에서 제안된 전산모형 프로그램의 정확성 및 효율성을 검증하고자 한다.

고강도 철근콘크리트 교각의 내진 거동 (Seismic Behavior of High-Strength Reinforced Concrete Bridge Columns)

  • 황선경;이진옥;류효진;윤현도;임병훈
    • 콘크리트학회논문집
    • /
    • 제17권4호
    • /
    • pp.505-511
    • /
    • 2005
  • 본 연구에서는 콘크리트 교각의 내진성능에 영향을 미치는 중요한 요인으로 보고되고 있는 콘크리트 강도, 횡보강근 체적비, 축력비를 실험변수로 하여 반복하중을 받는 고강도콘크리트 교각의 실험적 연구를 수행한 후 채택된 변수에 따른 교각의 파괴형태, 휨거동, 내진성능을 비교분석하고 기준식 및 제안식의 적용가능성을 검토하였다. 실험결과 철근콘크리트 교각의 하중-변위 관계에서 ACI규준에 의한 횡보강근 체적비보다 $44\%$증가시킨 경우 최대내력 이후 보다 안정된 이력거동 양상을 나타내었다. 기둥 하부에서 1.0D 떨어진 구간에서 주근 및 횡보강근이 큰 변형도를 보이고 있어 철근콘크리트 교각의 연성을 향상시키기 위해서는 주근의 좌굴을 방지하기 위한 횡보강근의 세심한 고려가 요구된다. 반복하중을 받는 교각의 휨강도는 ACI 규준식에 의한 이론 값보다 약 $20\%$ 증가된 값을 보이고 있어 ACI 규준식은 휨강도를 안전적으로 평가하는 것으로 나타났다. 시험체별 변위연성을 비교한 결과 횡보강근 체적비가 증가할수록 그리고 작용 축력비 및 콘크리트 압축강도가 감소할수록 변위 연성이 증가하는 경향을 나타내고 있어 철근콘크리트 교각의 연성에 횡보강근 체적비와 축력비 및 콘크리트의 압축강도가 중요한 요인으로 작용할 것으로 예상된다.

지역 의료이용 친화도(RI)와 병원 경영성과의 관계 (Relationship between Relevance Index and Hospital Management Performance)

  • 박종영;이진우
    • 디지털융복합연구
    • /
    • 제17권3호
    • /
    • pp.261-269
    • /
    • 2019
  • 본 연구는 우리나라의 종합병원의 경영성과와 지역 의료이용 친화도를 알 수 있는 RI를 과학적인 방법으로 산출하여 지역의료이용량과 병원 경영성과의 인과 관계에 대한 연구결과를 바탕으로 효율적인 경영전략을 제시하는데 그 연구의 의의가 있다. 연구결과를 보면 첫째, 일반적 특성에 따른 지역친화도 차이에서는 도시구분별 병상 수, 경상이익에서 통계적으로 유의한 차이가 나타났다. 둘째, 지역 의료이용의 친화도(RI)와 변수들 간의 상관관계를 살펴보면, 경상수지비율, 외래환자 초진율, 의료수익의료이익률, 100병상 당 1일 평균 외래환자 수, 100병상 당 1일 평균 입원환자 수, 입원환자 1인 1일당 평균진료비와 유의한 상관관계를 나타냈다. 연구결과를 바탕으로 본 연구의 의의를 살펴보면, 첫째 지역 의료이용 지표인 지역 의료이용 친화도를 산출하여 경영성과와의 연관관계와 유의한 영향을 미치는 변수를 규명하였다는 점에서 본 연구의 의의가 있다고 할 수 있다. 둘째로는 도시규모, 병상규모 등 내,외부적 환경요인에 따라 비교분석하였으며, 향후 병원이 지역 의료이용률를 높이기 위한 병원경영 전략의 수립에 기초 자료를 제공하였다고 할 수 있다.