• Title/Summary/Keyword: Capacity Expansion Model

Search Result 159, Processing Time 0.033 seconds

Analysis of Thermal Control Characteristics of VCHP by the Charging Mass of Non-Condensible Gas (불응축가스 주입량에 따른 VCHP의 열제어 특성)

  • Suh Jeong-Se;Park Young-Sik;Chung Kyung-Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1139-1144
    • /
    • 2005
  • This study has been performed to investigate the thermal performance of variable conductance heat pipe (VCHP) with meshed wick. The length of condenser portion in a VCHP is varied by the expansion of inert gas with the operation temperature, and the heat transport capacity is thus varied with the operating temperature. In this study, numerical evaluation of the VCHP is made for the thermal performance of VCHP, based on the diffusion model of inert gas. Water is used as a working fluid and nitrogen as a control inert gas in the copper tube. As a result, the thermal performance of VCHP has been compared with that of constant conductance heat pipe (CCHP) according to the variation of operation temperature. Maximum heat transport capacity of VCHP is mainly presented for operation temperature and the variation of operation temperature is also presented for heat transfer rate of VCHP.

Practical Modeling and PI Controller Design for Centrifugal Water Chillers (터보냉동기를 위한 실용적 모델링과 PI 제어기 설계)

  • Jeong, Seok-Kwon;Han, Sung-Joon;Jung, Young-Mi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.187-194
    • /
    • 2015
  • This paper describes the PI controller design based on a practical transfer function model for centrifugal water chillers. The rotational speed of a compressor and the opening angle of an electronic expansion valve were simultaneously regulated as manipulated variables to maintain temperature reference and to ensure high efficiency of the chiller. The COP according to the change in each variable was investigated by performing some static experiments, and it was reflected in the PI controller design to accomplish the high efficiency control. Especially, the practical transfer function model of the chiller was built based on the dynamic experimental data considering the strong inherent non-linearity and complexity of the chiller system. The validity of the designed PI controller was proven by some experimental results using the test facility and the results were also compared to the conventional evaporating pressure control results.

An Organizational Perspective on the Growth of Health Care Delivery System: Implications for Reform (의료공급체계의 성장과정과 개혁)

  • Han Dal Sun
    • Health Policy and Management
    • /
    • v.14 no.4
    • /
    • pp.21-47
    • /
    • 2004
  • There is general agreement that the Korean health care delivery system has two basic structural problems. One is the limited capacity and role of public hospitals, and the other is the absence of functional differentiation and referral arrangement between the clinics and hospitals of various technological sophistication levels. This study is intended to make an empirical observation of the system's growth process from the viewpoint of the population ecology model of organizations so as to understand the background of these problems and to find out ways of approaching them. As predicted from the population ecology model of organizations, all the types of medical care facilities have expanded in response to the environmental changes for the past three decades or so, and the differences in the extent and pattern of expansion among the types are related to what have taken place in the environment. These findings suggest that the efforts for reforming the health care delivery system should be directed not only to medical care institutions but also to the environmental context under which they function. It is believed that the usefulness of the population ecology perspective on organizations for studying the health care delivery system has been demonstrated. Thus further studies along this line based upon more strict design would improve systematic understanding of the system that is needed for developing policy approaches needed to increase its effectiveness.

Marine Ecosystem Response to Nutrient Input Reduction in Jinhae Bay, South Korea

  • Oh, Hyun-Taik;Lee, Won-Chan;Koo, Jun-Ho;Park, Sung-Eun;Hong, Sok-Jin;Jung, Rae-Hong;Park, Jong-Soo
    • Journal of Environmental Science International
    • /
    • v.15 no.9
    • /
    • pp.819-827
    • /
    • 2006
  • We study on the dynamic interaction with a simulated physical-biological coupled model response to nutrient reduction scenario in Jinhae Bay. According to the low relative errors, high regression coefficients of COD and DIN, and realistic distribution in comparison to the observation, our coupled model could be applicable for assessing the marine ecosystem response to nutrient input reduction in Jinhae Bay. Due to the new construction and expansion of sewage treatment plant from our government, we reduce 50% nutrient inputs near Masan Bay and sewage treatment plant. COD achieves Level II in Korea standard of the water quality from the middle of the Masan Bay to all around Jinhae Bay except the inner Masan Bay remaining at Level III. When our experiment reduces 50% nutrient inputs near Masan Bay and Dukdong sewage treatment plant simultaneously, COD decreases to about 0.1-1.2 mg/L $(128^{\circ}30'{\sim}128^{\circ}40'\;E,\;35^{\circ}05'{\sim}35^{\circ}11'\;N)$. The COD from the middle of the Masan Bay to Jinhae Bay achieves Level II.

Analysis of Thermal Control Performance of Variable Conductance Heat Pipe with Axial Grooves (축방향 그루브형 가변전열 히트파이프의 열제어 특성)

  • Park, Y.S.;Kim, D.E.;Byon, G.S.;Suh, J.S.;Lee, K.W.;Park, K.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1651-1656
    • /
    • 2003
  • The present study has been conducted to analytically investigate the thermal control performance of variable conductance heat pipe(YCHP) with axial grooves. The condenser port of the YCHP is occupied by a inert gas in which the concentration of gas is varied with the operation temperature and the heat transport capacity is thus varied with the operating temperature due to the variation of inert gas concentration. In this study, numerical evaluation for the thermal control of the YCHP with axial grooves is made from the 1st order diffusion model that considers the diffusive expansion of inert gas by concentration gradient. Ammonia is used as a working fluid and Nitrogen as a control gas in the Aluminum tube. As a result, the thermal performance of YCHP based on diffusion model has been compared with that of YCHP from flat front model. Additionally, it is found that the concentration of inert gas is distributed in the condenser region of YCHP with axial grooves.

  • PDF

Optimal Sizing Evaluation Model of Building Cogeneration System (건물용 열병합발전 시스템의 적정규모 산정을 위한 최적 투자모형)

  • Park, Jong-Seong;Won, Seon-Jae;Kim, Jung-Hoon;Park, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.117-119
    • /
    • 1995
  • For an effective application of the cogeneration system for commercial and industrial buildings, we need to develop a relevant model to determine the long-term based optimal sizing of the cogeneration system considering electrical and thermal load demands, buy and sell contracts with electric utility and the annual production cost. In assessing the optimal sizing of cogeneration, we have to consider both economic parameters and their capacity expansion for the increased electrical and thermals demand in the future. In this paper, we propose a mathematical model for the optimal sizing of cogeneration systems considering annual production costs and other economic parameter such as, lifetime of the equipment, time value of the capital, etc. In the case study, we thoroughly examine the effects of the economic parameters and determine the optimal size of the sample system. In addition, we calculate the payback period of the cogeneration investment.

  • PDF

The Neuroprotective Effects of Carnosine in Early Stage of Focal Ischemia Rodent Model

  • Park, Hui-Seung;Han, Kyung-Hoon;Shin, Jeoung-A;Park, Joo-Hyun;Song, Kwan-Young;Kim, Doh-Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.3
    • /
    • pp.125-130
    • /
    • 2014
  • Objective : This study was conducted to elucidate neuroprotective effect of carnosine in early stage of stroke. Methods : Early stage of rodent stroke model and neuroblastoma chemical hypoxia model was established by middle cerebral artery occlusion and antimycin A. Neuroprotective effect of carnosine was investigated with 100, 250, and 500 mg of carnosine treatment. And antioxidant expression was analyzed by enzyme linked immunosorbent assay (ELISA) and western blot in brain and blood. Results : Intraperitoneal injection of 500 mg carnosine induced significant decrease of infarct volume and expansion of penumbra (p<0.05). The expression of superoxide dismutase (SOD) showed significant increase than in saline group in blood and brain (p<0.05). In the analysis of chemical hypoxia, carnosine induced increase of neuronal cell viability and decrease of reactive oxygen species (ROS) production. Conclusion : Carnosine has neuroprotective property which was related to antioxidant capacity in early stage of stroke. And, the oxidative stress should be considered one of major factor in early ischemic stroke.

Design of Predictive Controller for Effective Superheat Control of Variable Speed Refrigeration System (가변속냉동시스템의 효율적인 과열도제어를 위한 예측제어기 설계)

  • Choi, Jeong-Pil;Hua, Li;Jeong, Seok-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.9-15
    • /
    • 2008
  • In this paper, we suggest PI control with a predictive controller to progress both energy saving and coefficient of performance(COP) in a variable speed refrigeration system. The capacity and superheat are controlled simultaneously and independently by an inverter and an electronic expansion valve respectively for saving energy and improving COP in the system. The refrigeration system has long dead time in superheat inherently. The dead time makes the system difficult to achieve the satisfactory quick control response, especially superheat control response. In order to solve this problem, we designed a predictive controller based on PI control to progress superheat control performance. The control performance was investigated through some experiments to verify the effectiveness of the predictive controller.

  • PDF

Optimizing Network Lifetime of RPL Based IOT Networks Using Neural Network Based Cuckoo Search Algorithm

  • Prakash, P. Jaya;Lalitha, B.
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.1
    • /
    • pp.255-261
    • /
    • 2022
  • Routing Protocol for Low-Power and Lossy Networks (RPLs) in Internet of Things (IoT) is currently one of the most popular wireless technologies for sensor communication. RPLs are typically designed for specialized applications, such as monitoring or tracking, in either indoor or outdoor conditions, where battery capacity is a major concern. Several routing techniques have been proposed in recent years to address this issue. Nevertheless, the expansion of the network lifetime in consideration of the sensors' capacities remains an outstanding question. In this research, aANN-CUCKOO based optimization technique is applied to obtain a more efficient and dependable energy efficient solution in IOT-RPL. The proposed method uses time constraints to minimise the distance between source and sink with the objective of a low-cost path. By considering the mobility of the nodes, the technique outperformed with an efficiency of 98% compared with other methods. MATLAB software is used to simulate the proposed model.

A Review of U.S. Renewable Energy Expansion and Support Policies (미국의 재생 에너지 확대 및 지원정책 연구)

  • Kim, Chu
    • Land and Housing Review
    • /
    • v.9 no.2
    • /
    • pp.41-50
    • /
    • 2018
  • The purpose of this study is to review the U.S. renewable energy policies implemented by the federal government and the state governments to investigate potential barriers of renewable energy expansion and to develop policy implications for the successful renewable energy policy making in Korea. Recently, the restructuring in the energy supply chain has been being a new trend in many countries that shows a transition from traditional fossil fuels to sustainable renewable energy sources. The United States has enforced effective renewable energy policies (i.e., regulatory policies, financial incentives), which have led to the exploding growth of renewable energy facilities and productions over the last ten years. For example, many state governments in the U.S. are implementing Renewable Portfolio Standard (RPS) policies that require increased energy supply from renewable energy sources (i.e., solar, wind and geothermal). These RPS policies are expected to account for at least 10-50 percent of total electricity production in the next fifteen years. As part of results, in the recent three years, renewable energy in the U.S provided over 50 percent of total new power generation constructions. On the other hand, Korea initiated to develop climate change policies in 2008 for the Green Growth Policy that set up a target reduction of national Greenhouse Gas (GHG) emissions up to 37 percent by 2025. However, statistical data for accumulated renewable energy capacity refer that Korea is still in its early stage that contribute to only 7 percent of the total electricity production capacity and of which hydroelectric power occupied most of the production. Thus, new administration in Korea announced a new renewable energy policy (Renewable Energy 3020 Plan) in 2017 that will require over 95 percent of the total new generations as renewable energy facilities to achieve up to 20 percent of the total electricity production from renewable energy sources by 2030. However, to date, there have not been enough studies to figure out the barriers of the current policy environment and to develop implications about renewable energy policies to support the government plan in Korea. Therefore, this study reviewed the U.S. renewable energy policies compared with Korean policies that could show model cases to introduce related policies and to develop improved incentives to rapidly spread out renewable energy facilities in Korea.