• 제목/요약/키워드: Capacitive micro-sensor

검색결과 24건 처리시간 0.019초

공기정합 스테이지의 위치결정오차 분석 및 보정 (Analysis and compensation of positioning error for aerostatic stage)

  • 황주호;박천홍;이찬흥;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.378-391
    • /
    • 2002
  • A 250mm stroke aerostatic stage, which detects position with laser scale and is driven by linear motor, is made and analyzed positioning error in 20$\pm$ 0.5 $^{\circ}C$ controlled atmosphere, aiming at investigating positioning characteristic of ultra-precision stage. We prove this aerostatic stage has a 10nm micro step resolution by experiment. By means of analyzing laser interferometer system, the scale of measuring error is about 0.2-0.4$\mu\textrm{m}$ according to refractive index error from missing the temperature change. To improve laser interferometer system, compensate refractive index error using measuring data from thermocouple. And, confirm 0.10$\mu\textrm{m}$ repeatability and 0.13 $\mu\textrm{m}$ positioning accuracy using the compensating refractive index. Also, we confirm 0.07 ${\mu}{\textrm}{m}$ repeatability of the stage using capacitive displacement sensor.

  • PDF

압전체 PZT 박막을 이용한 FET형 압력 센서의 제작과 그 특성 (Fabrication and Characteristics of FET-type Pressure Sensor Using Piezoelectric PZT Thin Film)

  • 김영진;이영철;권대혁;손병기
    • 센서학회지
    • /
    • 제10권3호
    • /
    • pp.173-179
    • /
    • 2001
  • 현재 사용되어지는 반도체형 압력센서에는 압저항형과 용량형이 있다. 특히 반도체 마이크로 압력센서는 크기도 작고 신호처리회로를 동일칩 위에 집적화 할 수 있어 많은 관심을 모아왔다. 그러나 이러한 형태의 센서들은 제조공정이 복잡해서 생산성이 낮다. 기존의 센서들이 가지는 단점들을 극복하기 위해 새로운 형태의 FET형 압력센서(PSFET : pressure sensitive field effect transistor)를 제안하고 그 동작특성을 조사하였다. 압력 감지 물질은 PZT(Pb(Zr,Ti)$O_3$)를 사용하였다. RF 마그네트론 스퍼터링법을 사용하여 MOSFET의 게이트 절연막 위에 PZT 압전 박막을 증착하였다. PZT의 안정적 상태인 perovskite 구조를 형성하기 위하여 PbO 분위기에서 열처리하는 기법을 도입하였다. 제작된 PSFET의 감도는 0.38 mV/mmHg이다.

  • PDF

TPMS용 4빔 실리콘 미세 압저항형 가속도센서의 설계 및 제작 (Design and Fabrication of 4-beam Silicon-Micro Piezoresistive Accelerometer for TPMS Application)

  • 박기웅;김현철
    • 대한전자공학회논문지SD
    • /
    • 제49권2호
    • /
    • pp.1-8
    • /
    • 2012
  • 본 논문은 자동차용 타이어 공기압 모니터링 시스템(TPMS)의 핵심 부품인 가속도센서에 관한 연구이다. 일반적으로 압저항형 가속도센서는 정전용량형 가속도센서에 비하여 제조 비용이 적고 출력 특성이 선형적이며 주변 잡음에 면역성이 강한 장점을 갖는다. 그래서 TPMS용으로 압저항형을 선택하였고, ANSYS 프로그램을 이용하여 3가지 타입의 구조를 설계하여 공진주파수 특성을 비교하여 가장 안정적인 구조인 질량체 가장자리의 가운데에 있는 4개의 빔에 의하여 지지되는 브릿지 타입의 실리콘압저항형 가속도센서를 선택하였다. 그리고 센서 크기를 고려하여 빔의 길이는 $200{\mu}m$로 정하였으며, 빔 길이에 따른 최대응력과 최대변위를 시뮬레이션하여 센서를 설계하였다. TPMS용 4 빔 실리콘 미세 압저항형 가속도센서의 크기는 $3.0mm{\times}3.0mm{\times}0.4mm$의 크기로 제작 되었다. 휠 각도에 따른 출력 특성과 온도 특성을 측정하여 센서의 특성을 분석 하였다. 그 결과 가속도센서의 옵셋 전압은 43.2 mV 이고 감도는 $42.5{\mu}V/V/g$ 이다. 센서의 특징으로 내충격성은 1500 g 이고, 측정 범위는 0 ~ 60 g, 사용온도는 $-40^{\circ}C{\sim}125^{\circ}C$ 를 갖는다.

Basic Physiological Research on the Wing Flapping of the Sweet Potato Hawkmoth Using Multimedia

  • Nakajima, Isao;Yagi, Yukako
    • Journal of Multimedia Information System
    • /
    • 제7권2호
    • /
    • pp.189-196
    • /
    • 2020
  • We have developed a device for recording biological data by inserting three electrodes and a needle with an angular velocity sensor into the moth for the purpose of measuring the electromyogram of the flapping and the corresponding lift force. With this measurement, it is possible to evaluate the moth-physiological function of moths, and the amount of pesticides that insects are exposed to (currently LD50-based standards), especially the amount of chronic low-concentration exposure, can be reduced the dose. We measured and recorded 2-channel electromyography (EMG) and angular velocity corresponding to pitch angle (pitch-like angle) associated with wing flapping for 100 sweet potato hawkmoths (50 females and 50 males) with the animals suspended and constrained in air. Overall, the angular velocity and amplitude of EMG signals demonstrated high correlation, with a correlation coefficient of R = 0.792. In contrast, the results of analysis performed on the peak-to-peak (PP) EMG intervals, which correspond to the RR intervals of ECG signals, indicated a correlation between ΔF fluctuation and angular velocity of R = 0.379. Thus, the accuracy of the regression curve was relatively poor. Using a DC amplification circuit without capacitive coupling as the EMG amplification circuit, we confirmed that the baseline changes at the gear change point of wing flapping. The following formula gives the lift provided by the wing: angular velocity × thoracic weight - air resistance - (eddy resistance due to turbulence). In future studies, we plan to attach a micro radio transmitter to the moths to gather data on potential energy, kinetic energy, and displacement during free flight for analysis. Such physiological functional evaluations of moths may alleviate damage to insect health due to repeated exposure to multiple agrochemicals and may lead to significant changes in the toxicity standards, which are currently based on LD50 values.