• Title/Summary/Keyword: Capacitive

Search Result 1,056, Processing Time 0.026 seconds

Enhanced Desalination Performance through Nafion-coated Cathode in Capacitive Deionization (축전식 탈염에서 나피온 코팅 음극을 통한 담수화 성능 향상)

  • Kim, Jieun;Jung, Seongwoo;Kim, Jinwook;Kim, Jaehwan;Kwak, Rhokyun
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.2
    • /
    • pp.13-20
    • /
    • 2022
  • An effective capacitive deionization process termed membrane capacitive deionization (MCDI) is newly designed and experimentally tested for seawater desalination. By preventing co-ions to be expelled, MCDI can improve the ion removal performance, but there is a trade-off between blocking co-ion transfer and increasing contact resistance. The conventional MCDI uses 2D-shaped films which increase contact resistance and reduce desalination performance in the trade-off. In this paper, with the 3-D shape of Nafion coated activated carbon cloth, the mentioned problems are expected to be solved making the desalination performance better. We visualized ion concentration and fluid flows with half-MCDI cell that can measure only efficiency of cathode. We found the optimal number of coatings which have the better efficiency than CMX, commercial cation exchange membrane in fixed current conditions of 100uA.

Application of Capacitive Deionization Packed Ion Exchange Resins in Two Flow Channels (두 가지 유로 형태에 따라 이온교환수지를 채운 축전식 탈염기술)

  • Lee, Dong-Ju;Park, Jin-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.1
    • /
    • pp.24-30
    • /
    • 2015
  • To desalinate the aqueous solutions with high salt concentration using the capacitive deionization technology, two resin/membrane capacitive deionization(RMCDI) cells were fabricated by filling mixed ion exchange resins in two different flow channels (spacer and spiral type). The salt removal efficiency of the spacer- and spiral-RMCDI was 77.21 and 99.94%, respectively. Many ions were significantly removed in a spiral RMCDI cell because the feed solution could be more evenly contacted with the ion exchange resins filled on the spiral type flow channel. As the result of the changes of pH and accumulative charges, it was observed that Faradaic reaction was diminished for a spiral RMCDI cell filled by the mixture of cation and anion exchange resins. Therefore, the desalination of the aqueous solutions with high salt concentration by the capacitive deionization technology was proven. In addition, further studies on the optimization of the mixing ratio with ion exchange resins and the introduction of the regeneration process generally occurred in the continuous electrodeionization (CEDI) technology are required to improve the RMCDI technology.

Humidity Sensitive Characterization by Electrode Pattern on the Capacitive Humidity Sensor Using Polyimide (폴리이미드 용량형 습도센서의 전극 패턴에 따른 감습 특성)

  • Park, Sung-Back;Shin, Hoon-Kyu;Lim, Jun-Woo;Chang, Sang-Mok;Kwon, Young-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.9
    • /
    • pp.566-570
    • /
    • 2014
  • Electrode pattern effects on the capacitive humidity sensor were investigated. The fabrication of the capacitive humidity sensor was formed with three steps. The bottom electrode was formed on the silicon substrate with Pt/Ti thin layer by using shadow mask and e-beam evaporator. The photo sensitive polyimide was formed on the bottom electrode by using photolithography process as a humidity sensitive thin film. The upper electrode was formed on the polyimide thin film with Pt/Ti thin layer by using e-beam evaporator and lift-off method. Three electrode patterns, such as circle, square, and triangle pattern, were used and changed the sizes to investigate the effects. The capacitances of the sensors were decreased 622 to 584 pF with the area decreament of patterns 250,000 to $196,250{\mu}m^2$. From these results, a capacitive humidity sensor with photo sensitive polyimide is expected to be applied to a high sensitive humidity sensor.

Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System (패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극)

  • Lee, Jeong Su;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.203-210
    • /
    • 2014
  • Wearable medical device has been a resurgence of interest thanks to the development of technology and propagation of smart phone in recent years. Various types of wearable devices have been introduced and available in market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearable device. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrode to body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram (ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system be adhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-to-digital converter and wireless transmission module and designed to be attached on the body as a patch. To validate the feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethane and adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoring in real-life.

Design of Multi-Finger Flick Interface for Fast File Management on Capacitive-Touch-Sensor Device (정전기식 입력 장치에서의 빠른 파일 관리를 위한 다중 손가락 튕김 인터페이스 설계)

  • Park, Se-Hyun;Park, Tae-Jin;Choy, Yoon-Chul
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.8
    • /
    • pp.1235-1244
    • /
    • 2010
  • Most emerging smart phones support capacitive touch sensors. It renders existing gesture-based interfaces not suitable since they were developed for the resistive touch sensors and pen-based input. Unlike the flick gestures from the existing gesture interfaces, the finger flick gesture used in this paper reduces the workload about half by selecting the target and the command to perform on the target at a single touch input. With the combination with multi-touch interface, it supports various menu commands without having to learn complex gestures, and is suitable for the touch-based devices hence it minimizes input error. This research designs and implements the multi-touch and flick interface to provide an effective file management system on the smart phones with capacitive touch input. The evaluation proves that the suggested interface is superior to the existing methods on the capacitive touch input devices.

Performance Study of Membrane Capacitive Deionization Installed with Sulfonated Poly(ether ether ketone) and Poly(vinyl amine)/poly(vinyl alcohol) Membranes (Sulfonated Poly(ether ether ketone) 및 Poly(vinyl amine)/poly(vinyl alcohol) 혼합막이 장착된 막결합형 축전식 탈염공정의 성능 연구)

  • Kim, Ka young;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.26 no.1
    • /
    • pp.62-69
    • /
    • 2016
  • In this study, sulfonated poly(ether ether ketone) (SPEEK) as cation exchange membrane and blended and crosslinked poly(vinyl amine) (PVAm) with poly(vinyl alcohol) (PVA) membrane as anion exchange membrane were used and then the performance experiments of the membrane capacitive deionization (MCDI) installed with both membranes were carried out. The newly prepared anion exchange membrane were characterized through water content, ion exchange capacity and FT-IR. The crosslinking time of 3 h to 5 h indicated that the salt removal was reduced from 81.3, 65.7% to 53.8%. The effect of PVAm contents from 40, 60, to 80% on the salt removal was shown 81.3, 75.2 and 37.7%, respectively. As a result, it was concluded that the crosslinking time and the content of PVAm had an influence on the salt removal efficiency.

Preceding Study on the Sensing Part of Level Measurement System of Launch Vehicle Propellant Tanks (발사체 탱크 추진제 수위 측정시스템 감지부 선행연구)

  • Shin, Dong-Sun;Lee, Eung-Shin;Ko, Hyun-Seok;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.54-57
    • /
    • 2009
  • The propellant level measurement system of the next Koreanized launch vehicle shall adapt a capacitive type sensor, which can generate capacitive values continuously considering cryogenic environment and the characteristics of flowrate control. At present there are a twin-arc and a triple-arc methods as a capacitive type signal sensing method. In this study a highly accurate triple-arc method, which can apply to almost all fluids, is chosen. In this paper the review results on the principle of triple-arc sensing, the analysis results on the influence on capacitive values due to shape change of sensing part, and the simulation results to monitor the influence on signal sensing according to the location of sensing part in the upper part of propellant tank are included. Information obtained from this study can be used in the designing and manufacturing of on-board propellant level measurement system in tanks.

  • PDF

A Design of Multi-Channel Capacitive Touch Sensing ASIC for SoC Applications in 0.18 ${\mu}m$ CMOS Process (0.18 ${\mu}m$ CMOS 공정을 이용한 SoC용 정전 용량형 멀티 채널 터치 센싱 ASIC의 설계)

  • Nam, Chul;Pu, Young-Gun;Park, Joon-Sung;Hong, Seong-Hwa;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.4
    • /
    • pp.26-33
    • /
    • 2010
  • This paper presents a multi-channel capacitive touch sensing unit for SoC applications. This unit includes a simple common processing unit and switch array to detect the touch sensing input by capacitive-time(C-T) conversion method. This touch sensor ASIC is designed based on the Capacitive-Time(C-T) conversion method to have advantages of small current and chip area, and the minimum resolution of the unit is 41 fF per count with the built-in sensing oscillator, LDO regulator and $I^2C$ for no additional external components. This unit is implemented in 0.18 um CMOS process with dual supply voltage of 1.8 V and 3.3 V. The total power consumption of the unit is 60 uA and the area is 0.26 $mm^2$.

A Study on RF Characteristics of Transmission Line Employing Inverted Periodically Arrayed Capacitive Devices for Application to Highly Miniaturized Wireless Communication system on MMIC (MMIC 상에서 초소형 무선 통신 시스템에의 응용을 위한 반전된 형태의 주기적 용량성 구조를 이용한 전송선로의 RF 특성에 관한 연구)

  • Kim, Jeong-Hoon;Jang, Jang-Hyeon;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.52-57
    • /
    • 2015
  • In this paper, we studies on the RF characteristics of the transmission line employing IPACD (inverted periodically arrayed capacitive devices) on MMIC (monolithic microwave integrated circuit) for application to wireless communication system. According to measured results, the novel transmission line employing IPACD showed a wavelength much shorter than conventional transmission lines. In addition, the IPACD structure showed an effective permittivity much higher than conventional ones. We also extracted the bandwidth characteristic of the IPACD structure using equivalent circuit analysis. According to the results, the cut-off frequency of the proposed structure was 129.2 GHz.

A Study on comnon-mode-driven shield for capacitive coupling active electrode (용량성 결합 능동 전극의 공통 모드 구동 차폐)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily life. This study introduced a new method of electrode circuit design developed for reducing the 60Hz power line noise observed at the indirect-contact ECG measurement. By the introduced common-mode-driven shielding, the voltage of the electrical shield surrounding the capacitive coupling electrode is maintained at the same as the common mode voltage. Though the method cannot reduce the level of common mode voltage itself, that reduces effectively the differential mode noise converted from the common mode voltage by the difference of cloth impedance between the two capacitive coupling electrode. The experiment results using the actual indirect-contact ECG showed that the 60Hz power line noise was reduced remarkably though the reduction ratio was smaller than the expected by the theory. Especially, the reduction ratio became large for the large difference of cloth. It is expected that the introduced method is useful for reducing the power line noise under condition of poor electrical grounding.