A STUDY OF CORE TYPE AND LUTING CEMENTS ON COMPLETE CAST CROWN RETENTION (코어 형태와 시멘트 종류에 따른 전부주조금관의 유지력에 관한 연구)

  • Paek, Sang-Hyun;Chang, Ik-Tae;Lee, Sun-Hyung;Yang, Jae-Ho;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.169-177
    • /
    • 2000
  • The purpose of this study was to compare the retention of complete cast crown over amalgam ores, composite resin cores, and cast gold cores when cemented with three different luting agents. Eighteen core specimens each of amalgam(Bestaloy, Dong Myung, Seoul, Korea), composite resin (Z100, 3M Dental product, st. Paul, Minn) and type IV gold alloy (Ba-4, Heesung Engelhard Corp., Korea) were made in a customized milling stainless steel die. A wax pattern with a loop attached to occlusal surface was made for each core and a type II gold alloy casting was fabricated. The castings which had clinically acceptable marginal fit were used as test samples. The following luting cements were used to cement cast crowns on each core material : (1) zinc phosphate cement (Confi-dental Products Co., USA) (2) glass-ionomer cement (Fuji Plus, GC Industrial Corp., Tokyo, Japan) (3) resin cement (Panavia 21, Kuraray Co., USA). All cements were mixed according to manufacturers' instructions. A static load of 5kg was then applied for 10 minutes on the crowns. All specimens were stored in saline solution for 24 hours at $37^{\circ}C$ and thermocycled for 500 cycles. After storage and cycling, the tensile bond strengths were measured by using a universal testing machine (Instron Corp., Canton, Mass.) at a crosshead speed of 0.5mm/min. The results were as follows 1. The retentive strength of resin cement was the highest of alt three types of cement for resin core (p<0.05). 2. There was no statistical difference among the retentive strengths of three cements for amalgam core (p>0.05). 3. The retentive strength of resin cement was higher than that of zinc phosphate for cast core, but there was no difference between the retentive strength of glass ionomer cement and those of rein and zinc phosphate cement. 4. The retentive strength of the zinc phosphate cement for amalgam core was the highest of all type of cores.

  • PDF

The effect of low temperature aging on the mechanical property & phase stability of Y-TZP ceramics

  • Kim, Hyung-Tae;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.113-117
    • /
    • 2009
  • STATEMENT OF PROBLEM. Recently Yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) has been introduced due to superior flexural strength and fracture toughness compared to other dental ceramic systems. Although zirconia has outstanding mechanical properties, the phenomenon of decrease in the life-time of zirconia resulted from degradation in flexural strength after low temperature aging has been reported. PURPOSE. The objective of this study was to investigate degradation of flexural strength of Y-TZP ceramics after various low temperature aging treatments and to evaluate the phase stability and micro-structural change after aging by using X-ray diffraction analysis and a scanning electron microscope (SEM). MATERIAL AND METHODS. Y-TZP blocks of Vita In-Ceram YZ (Vita Zahnfabrik, Bad $S\ddot{a}ckingen$, Germany) were prepared in 40 mm (length) $\times$ 4 mm (width) $\times$ 3 mm (height) samples. Specimens were artificially aged in distilled water by heat-treatment at a temperature of 75, 100, 125, 150, 175, 200, and $225^{\circ}C$ for 10 hours, in order to induce the phase transformation at the surface. To measure the mechanical property, the specimens were subjected to a four-point bending test using a universal testing machine (Instron model 3365; Instron, Canton, Mass, USA). In addition, X-ray diffraction analysis (DMAX 2500; Rigaku, Tokyo, Japan) and SEM (Hitachi s4700; Jeol Ltd, Tokyo, Japan) were performed to estimate the phase transformation. The statistical analysis was done using SAS 9.1.3 (SAS institute, USA). The flexural strength data of the experimental groups were analyzed by one-way analysis of variance and to detect statistically significant differences ($\alpha$= .05). RESULTS. The mean flexural strength of sintered Vita In-Ceram YZ without autoclaving was 798 MPa. When applied aging temperature at below $125^{\circ}C$ for 10 hours, the flexural strength of Vita In-Ceram YZ increased up to 1,161 MPa. However, at above $150^{\circ}C$, the flexural strength started to decrease. Although low temperature aging caused the tetragonal-to-monoclinic phase transformation related to temperature, the minimum flexural strength was above 700 MPa. CONCLUSION. The monoclinic phase started to appear after aging treatment above $100^{\circ}C$. With the higher aging temperature, the fraction of monoclinic phase increased. The ratio of monoclinic/tetragonal + monoclinic phase reached a plateau value, circa 75% above $175^{\circ}C$. The point of monoclinic concentration at which the flexural strength begins to decrease was between 12% and 54%.

A vision-based system for long-distance remote monitoring of dynamic displacement: experimental verification on a supertall structure

  • Ni, Yi-Qing;Wang, You-Wu;Liao, Wei-Yang;Chen, Wei-Huan
    • Smart Structures and Systems
    • /
    • v.24 no.6
    • /
    • pp.769-781
    • /
    • 2019
  • Dynamic displacement response of civil structures is an important index for in-construction and in-service structural condition assessment. However, accurately measuring the displacement of large-scale civil structures such as high-rise buildings still remains as a challenging task. In order to cope with this problem, a vision-based system with the use of industrial digital camera and image processing has been developed for long-distance, remote, and real-time monitoring of dynamic displacement of supertall structures. Instead of acquiring image signals, the proposed system traces only the coordinates of the target points, therefore enabling real-time monitoring and display of displacement responses in a relatively high sampling rate. This study addresses the in-situ experimental verification of the developed vision-based system on the Canton Tower of 600 m high. To facilitate the verification, a GPS system is used to calibrate/verify the structural displacement responses measured by the vision-based system. Meanwhile, an accelerometer deployed in the vicinity of the target point also provides frequency-domain information for comparison. Special attention has been given on understanding the influence of the surrounding light on the monitoring results. For this purpose, the experimental tests are conducted in daytime and nighttime through placing the vision-based system outside the tower (in a brilliant environment) and inside the tower (in a dark environment), respectively. The results indicate that the displacement response time histories monitored by the vision-based system not only match well with those acquired by the GPS receiver, but also have higher fidelity and are less noise-corrupted. In addition, the low-order modal frequencies of the building identified with use of the data obtained from the vision-based system are all in good agreement with those obtained from the accelerometer, the GPS receiver and an elaborate finite element model. Especially, the vision-based system placed at the bottom of the enclosed elevator shaft offers better monitoring data compared with the system placed outside the tower. Based on a wavelet filtering technique, the displacement response time histories obtained by the vision-based system are easily decomposed into two parts: a quasi-static ingredient primarily resulting from temperature variation and a dynamic component mainly caused by fluctuating wind load.

Comparison of the retention of the full veneer casted gold crowns with varying convergence angle, crown length and dental cements (수렴각과 치관 길이를 달리한 금속 다이상에서 치과용 시멘트 합착 후 전부주조관의 유지력 비교)

  • Yun, Jung-Ho;Cho, Jin-Hyung;Kim, Jee-Hwan;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.2
    • /
    • pp.99-106
    • /
    • 2013
  • Purpose: The aim of this research was to establish the effect and variation in differing convergence angle and length of abutment on the retention of full veneer casted gold crown. Materials and methods: Two different length,5 mm and 10 mm in height with convergence angles of 5, 10, 15 and 25 degrees crowns were fabricated. Cementation was done using cements; zinc phosphate cement (Fleck's zinc phosphate cement), resin-modified glass ionomer cement (Vitremer) and resin cement (Panavia 21). These were tested for tensile force at the point of separation by using Instron Universal Testing Machine. Statistical analysis was done by SAS 6.04 package. Results: In all cements the mean retention decreased with significant difference on increase of convergence angle (P<.05). Increase in every 5 degree-convergence angel the retention rate decreased with resin-modified glass ionomer cement of 15.9% and resin cement of 14.8%. With zinc phosphate cement, there was largest decreasing rate of mean retention of 25.5% between convergence angles from 5 degree to 10 degree. When the crown length increased from 5 mm to 10 mm, the retention increased with the significant difference in the same convergence angle and in all types of cement used (P<.05). Conclusion: The retention was strongly dependent on geometric factors of abutment. Much care is required in choosing cements for an optimal retention in abutments with different convergence angles and crown lengths.

In Vitro Evaluation of Shear Bond Strengths of Zirconia Cerami with Various Types of Cement after Thermocycling on Bovine Dentin Surface (지르코니아 표면 처리와 시멘트 종류에 따른 치면과의 전단 결합 강도 비교 연구)

  • Cho, Soo-Hyun;Cho, In-Ho;Lee, Jong-Hyuk;Nam, Ki-Young;Kim, Jong-Bae;Hwang, Sang-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.249-257
    • /
    • 2007
  • State of problem : The use of zirconium oxide all-ceramic material provides several advantages, including a high flexural strength(>1000MPa) and desirable optical properties, such as shading adaptation to the basic shades and a reduction in the layer thickness. Along with the strength of the materials, the cementation technique is also important to the clinical success of a restoration. Nevertheless, little information is available on the effect of different surface treatments on the bonding of zirconium high-crystalline ceramics and resin luting agents. Purpose : The aim of this study was to test the effects of surface treatments of zirconium on shear bond strengths between bovine teeth and a zirconia ceramic and evaluate differences among cements Material and methods : 54 sound bovine teeth extracted within a 1 months, were used. They were frozen in distilled water. These were rinsed by tap water to confirm that no granulation tissues have left. These were kept refrigerated at $4^{\circ}C$ until tested. Each tooth was placed horizontally at a plastic cylinder (diameter 20mm), and embedded in epoxy resin. Teeth were sectioned with diamond burs to expose dentin and grinded with #600 silicon carbide paper. To make sure there was no enamel left, each was observed under an optical microscope. 54 prefabricated zirconium oxide ceramic copings(Lava, 3M ESPE, USA) were assigned into 3 groups ; control, airborne-abraded with $110{\mu}m$ $Al_2O_3$ and scratched with diamond burs at 4 directions. They were cemented with a seating force of 10 ㎏ per tooth, using resin luting cement(Panavia $F^{(R)}$), resin cement(Superbond $C&B^{(R)}$), and resin modified GI cement(Rely X $Luting^{(R)}$). Those were thermocycled at $5^{\circ}C$ and $55^{\circ}C$ for 5000 cycles with a 30 second dwell time, and then shear bond strength was determined in a universal test machine(Model 4200, Instron Co., Canton, USA). The crosshead speed was 1 mm/min. The result was analyzed with one-way analysis of variance(ANOVA) and the Tukey test at a significance level of P<0.05. Results : Superbond $C&B^{(R)}$ at scratching with diamond burs showed the highest shear bond strength than others (p<.05). For Panavia $F^{(R)}$, groups of scratching and sandblasting showed significantly higher shear bond strength than control group(p<.05). For Rely X $Luting^{(R)}$, only between scratching & control group, significantly different shear bond strength was observed(p<.05). Conclusion : Within the limitation of this study, Superbond $C&B^{(R)}$ showed clinically acceptable shear bond between bovine teeth & zirconia ceramics regardless of surface treatments. For the surface treatment, scratching increased shear bond strength. Increase of shear bond strength by sandblasting with $110{\mu}m$ $Al_2O_3$ was not statistically different.

COMPARATIVE STUDY OF PHYSICAL PROPERTIES FOR VARIOUS BAND CEMENTS (수종의 밴드 접착 시멘트의 물성에 대한 비교 연구)

  • Yang, Kyu-Ho;Kim, Ki-Baek;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.427-432
    • /
    • 2009
  • The aim of this study was to compare the shear-peel strength and the fracture site of 5 commercially available orthodontic band cements. One hundred molar bands were cemented to extracted human 3rd molars. The specimens were prepared in accordance with the manufacturer's instructions for each cement. After storage in a humidor at $37^{\circ}C$ for 24 hours, the shear debonding force was assessed for each specimen using an universal testing machine with crosshead speed of 2 mm/minute. Maximal failure stress was converted to mean shear-peel strength, MPa. The predominant site of band failure was recorded visually for all specimens as either at the band/cement or cement/enamel interface. Mean shear-peel strength of Ormco was the highest(2.44${\pm}$0.57), followed by Fuji $Ortho^{TM}$(2.24${\pm}$0.50), $Ketac-Cem^{TM}$(2.10${\pm}$0.57), 3M $Unitek^{TM}$(1.82${\pm}$0.43), $Band-Lok^{TM}$(1.73${\pm}$0.28). There were statistically significant differences between Ormco and $Band-Lok^{TM}$, Ormco and 3M $Unitek^{TM}$, and Fuji $Ortho^{TM}$ and $Band-Lok^{TM}$(p<0.05). The predominant site of bonding failure for bands cemented with the Ormco was at the band/cement interface, whereas bands cemented with Ultra $Band-Lok^{TM}$ failed predominantly at the enamel/cement interface. There was no significant difference among the other cements(Fuji $Ortho^{TM}$, 3M $Unitek^{TM}$, $Ketac-Cem^{TM}$).

  • PDF

Evaluation of shear-bond strength between different self-adhesive resin cements with phosphate monomer and zirconia ceramic before and after thermocycling (인산염계 기능성 단량체가 첨가된 수종의 자가 접착 레진시멘트와 지르코니아 세라믹 사이 열순환 전후 전단결합강도 비교)

  • Lee, Ji-Hun;Kim, Min-Kyung;Lee, Jung-Jin;Ahn, Seung-Geun;Park, Ju-Mi;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.318-324
    • /
    • 2015
  • Purpose: This study compared shear bond strengths of five self-adhesive cements with phosphate monomer to zirconium oxide ceramic with and without airborn particle abrasion. Materials and methods: One hundred zirconia samples were air-abraded ($50{\mu}mAl_2O_3$). One hundred composite resin cylinders were fabricated. Composite cylinders were bonded to the zirconia samples with either Permacem 2.0 (P), $Clearfil^{TM}$ SA Luting (C), $Multilink^{(R)}$ Speed (M), $RelyX^{TM}$ U200 Automix (R), G-Cem $LinkAce^{TM}$ (G). All bonded specimens were stored in distilled water ($37^{\circ}C$) for 24 h and half of them were additionally aged by thermocycling ($5^{\circ}C$, $55^{\circ}C$, 5,000 times). The bonded specimens were loaded in shear force until fracture (1 mm/min) by using Universal Testing Machine (Model 4201, Instron Co, Canton, MA, USA). The failure sites were inspected under field-emission scanning electron microscopy. The data was analyzed with ANOVA, Tukey HSD post-hoc test and paired samples t-test ($\alpha$=.05). Results: Before and after thermocycling, $Multilink^{(R)}$ Speed (M) revealed higher shear-bond strength than the other cements. G-Cem $LinkAce^{TM}$ (G) showed significantly lower bond strengths after thermocycling than before treatment (P<.05), but the other groups were not significantly different (P>.05). Conclusion: Most self-adhesive cements with phosphate monomer showed high shear bond strength with zirconia ceramic and weren't influenced by thermocycling, so they seem to valuable to zirconia ceramic bonding.

Human Papillomavirus Genotypes among Females in Mexico: a Study from the Mexican Institute for Social Security

  • Salcedo, Mauricio;Pina-Sanchez, Patricia;Vallejo-Ruiz, Veronica;Monroy-Garcia, Alberto;Aguilar-Lemarroy, Adriana;Cortes-Gutierrez, Elva I.;Santos-Lopez, Gerardo;Montoya-Fuentes, Hector;Grijalva, Renan;Madrid-Marina, Vicente;Apresa-Garcia, Teresa;Hernandez, Dulce M.;Jave-Suarez, Luis F.;Romero, Pablo;Poot, Albros;Salgado, Eduardo;Ramos-Gonzalez, Patricia;Gonzalez-Hernandez, Rigoberto;Canton, Juan C.;Jimenez-Aranda, Lucio;Parra-Melquiadez, Miriam;Paniagua, Lucero;Mendoza, Monica;Arreola, Hugo;Villegas, Vanesa;Torres-Poveda, Kirvis;Bahena-Roman, Margarita;Gonzalez-Yebra, Beatriz;Taniguchi, Keiko;Rodea, Carlos;Mantilla-Morales, Alejandra;Mora-Garcia, Maria L.;Velazquez-Velazquez, Cindy K.;Cordova-Uscanga, Candelaria;Peralta, Raul;Lopez-Romero, Ricardo;Marrero, Daniel;Bandala, Cindy;Reyes-Leyva, Julio;Furuya, Maria E.;Almeida, Eduardo;Galvan, Maria E.;Grijalva, Israel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10061-10066
    • /
    • 2015
  • Background: The aetiological relationship between human papillomavirus (HPV) infection and cervical cancer (CC) is widely accepted. Our goal was to determine the prevalence of HPV types in Mexican women attending at the Mexican Institute for Social Security from different areas of Mexico. Materials and Methods: DNAs from 2,956 cervical samples were subjected to HPV genotyping: 1,020 samples with normal cytology, 931 with low-grade squamous intraepithelial lesions (LGSIL), 481 with high grade HGSIL and 524 CC. Results: Overall HPV prevalence was 67.1%. A total of 40 HPV types were found; HPV16 was detected in 39.4% of the HPV-positive samples followed by HPV18 at 7.5%, HPV31 at 7.1%, HPV59 at 4.9%, and HPV58 at 3.2%. HPV16 presented the highest prevalence both in women with altered or normal cytology and HPV 18 presented a minor prevalence as reported worldwide. The prevalence ratio (PR) was calculated for the HPV types. The analysis of PR showed that HPV16 presents the highest association with CC, HPV 31, -33, -45, -52 and -58 also demonstrating a high association. Conclusions: The most prevalent HPV types in cervical cancer samples were -16, -18, -31, but it is important to note that we obtained a minor prevalence of HPV18 as reported worldwide, and that HPV58 and -52 also were genotypes with an important prevalence in CC samples. Determination of HPV genotypes is very important in order to evaluate the impact of vaccine introduction and future cervical cancer prevention strategies.