• Title/Summary/Keyword: Cannulated screw

Search Result 48, Processing Time 0.021 seconds

Anterior Screw Fixation using Herbert Screw for Type II Odontoid Process Fractures

  • Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.5
    • /
    • pp.345-349
    • /
    • 2005
  • Objective: Anterior screw fixation provides the best anatomical and functional results for type II odontoid process fracture (type II-A, II-N, and II-P) with intact transverse ligament. The purpose of this study is to evaluate the usefulness of the 4.5mm diameter, cannulated Herbert screw in anterior screw fixation. Methods: From Jan. 2003 to Feb. 2004, consecutive 10cases of type II odontoid process fractures were treated with anterior screw fixation using a Herbert screw. The Herbert screw has double threads, with different pitches on the distal and proximal ends. It has no head, so it can be inserted through articular cartilage and buried below bone surface. It was originally developed for treating scaphoid fractures. Results: There were 8male and 2female patients whose ages ranged from 15 to 67years (mean 42.1years). The fracture type was type II-A in 4patients, II-N in 3 patients, and II-P in 3 patients. The fracture line was oblique downward and backward in 6cases, oblique downward and forward in 1 case, and horizontal in 3cases. The range of follow-up was 5 to 18months (mean 12months). Bone fusions were achieved in all cases without any instrumental failures or postoperative complications. Conclusion: The Herbert screw is very useful in anterior fixation for type II odontoid process fracture. This series showed successful results also in type II-A odontoid fracture when treated with the Herbert screw, but further more studies are required.

Polymethylmethacrylate-Augmented Screw Fixation for Stabilization of the Osteoporotic Spine : A Three-Year Follow-Up of 37 Patients

  • Moon, Bong-Ju;Cho, Bo-Young;Choi, Eun-Young;Zhang, Ho-Yeol
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.305-311
    • /
    • 2009
  • Objective : The purpose of this study was to determine the efficacy, radiological findings, clinical outcomes and complications in patients with lumbar stenosis and osteoporosis after the use of polymethylmethacrylate (PMMA) augmentation of a cannulated pedicle screw. Methods : Thirty-seven patients with degenerative spinal stenosis and osteoporosis (T-score < -2.5) underwent lumbar fusion using the Dream Technology Pedicle Screw ($DTPS^{TM}$, Dream Spine Total Solutions, Dream STS, Seoul. Korea) between 2005 and 2007. The clinical outcomes were evaluated by using the visual analog scale (VAS) and the Prolo scale. Radiologic findings were documented through computed tomography (CT) and plain films. Results : Thirty-seven patients were evaluated and included, 2 males and 35 females with an average bone mineral density (BMD) of $0.47g/cm^2$. The average age of the patients was 68.7 (range, 57-88). The preoperative VAS for low back and leg pain ($7.87{\pm}0.95$ and $8.82{\pm}0.83$) were higher as compared with postoperative VAS ($2.30{\pm}1.61$ and $1.42{\pm}0.73$) with statistical significance (p = 0.006, p = 0.003). According to the Prolo scale, 11, 22, one and three patients were in excellent, good, fair and poor conditions, respectively. The average amount of the injected cement per one cannulated screw was $1.83{\pm}0.11\;mL$. Conclusion : The results show favorable outcome both clinically and radiographically for 37 patients who underwent lumbar fusion using $DTPS^{TM}$ and PMMA. Based on the results, the use of this surgical method can be a safe and effective option for the operation on the osteoporotic spine.

Treatment of Lateral Malleolar Fractures with Cannulated Screws in Danis-Weber type B Ankle Fractures (Danis-Weber B형 족근 관절 골절에 있어 유경 나사를 이용한 비골 외 과 골절의 치료)

  • Park, Yong-Wook;Chung, Yung-Khee;Yoo, Jung-Han;Park, Hong-Jun;Yu, Sun-O;Kang, Ki-Man
    • Journal of Korean Foot and Ankle Society
    • /
    • v.5 no.2
    • /
    • pp.129-135
    • /
    • 2001
  • Purpose: To evaluate the radiographic results of the treatment for Danis-Weber type B lateral malleolar fracture with 2 cannulated screws. Materials and Methods: Thirty-four cases of Danis-Weber type B lateral malleolar fracture were available. Follow-up averaged 8 months (6-25 months). The medial clear space for lateral displacement of talus, talo-crural angle for lateral malleolar shortening, and malunion evidence of lateral malleolar fracture were observed. Results: Medial clear space was from 2mm to 4mm in 34 cases. Talo-crural angle was from $73^{\circ}$ to $82.5^{\circ}$ in 33 cases. One case was complicated with malunion of lateral malleolus. But, we found the same condition in the immediate post- operative radiographic film. Conclusion: We believe that the 2 cannulated screws fixation for Danis-Weber type B lateral malleolar simple fractures is an excellent treatment method.

  • PDF

Removal of broken syndesmotic screw with minimal bone defects in Korea: a case report

  • Min Gyu Kyung;Chulhee Park
    • Journal of Trauma and Injury
    • /
    • v.36 no.3
    • /
    • pp.265-268
    • /
    • 2023
  • Ankle fractures with syndesmotic injuries often require fixation, where metal screw fixation is a popular method. However, as the patient begins weight-bearing, most syndesmotic screws tend to loosen or break, and removal of such screws has been challenging for the surgeons, as the available techniques require predrilling or trephination and are associated with risks of bone damage. This study presents a case with technical tip for the removal of broken tricortical-fixed non-cannulated syndesmotic screws. It implements the generation of a small cortical window in the medial distal tibia and the use of pliers to engage the screw tip and remove through the medial side. The technique presented in the current study overcomes these limitations and facilitates minimal bone damage and reduced exposure to radiation.

Arthroscopic Reduction and Internal Fixation with Cannulated Screw of a Transverse Glenoid Fracture (유경 나사를 이용한 견갑골 관절와 횡골절의 관절경적 정복 밑 내고정)

  • Noh Kyu Cheol;Yoo Jung Han;Kang Ki Man
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.176-180
    • /
    • 2003
  • We describe in this report the accurate reduction of a transverse displaced glenoid fracture through arthroscopic control . We used the lateral and superior (Neviaser portal) portal of the arthroscopic surgery in the shoulder joint for the U 4.0-mm titanium cannulated cancellous screw fixation. The advantages of this treatment are excellent intra-articular visualiBation, decreased soft tissue dissection ,less blood loss, shortened postoperative recovery and early ROM exercise. There(ore, we report the method of operation and the cases .

  • PDF

Evaluation of minimally invasive surgical reduction of sacroiliac luxation in toy breed dogs: a cadaver study

  • Ahn, Seoung-Yob;Jeong, Soon-Wuk
    • Journal of Veterinary Science
    • /
    • v.23 no.2
    • /
    • pp.38.1-38.13
    • /
    • 2022
  • Background: Minimally invasive surgery (MIS) technique of sacroiliac luxation in toy breed dogs using cannulated screws has not been described. Objectives: The purpose of this study was to evaluate the effectiveness of pelvic canal recovery, the reproducibility of successful surgery outcomes, and the acceptable difficulty of the procedure in MIS of sacroiliac luxation in toy breed dogs. Methods: MIS using 2.3-mm cannulated screws was demonstrated in 12 toy breed dog cadavers with sacroiliac luxation artificially induced. Pre and postoperative radiographs were used to evaluate the pelvic canal diameter ratio (PCDR), hemipelvic canal width ratio (HCWR), and reduction rate. Dorsoventral angle (DVA) and craniocaudal angle (CCA) of the inserted screw were obtained postoperative computed tomographic scan. Results: The statistically significant difference between the mean pre and postoperative PCDR was found (1.10 ± 0.12 and 1.26 ± 0.11, respectively; p = 0.002), and the mean HCWR close to 1.0 meaning symmetric pelvis also was obtained (0.97 ± 0.07). The mean DVA and CCA were 2.26° ± 1.33° and 2.60° ± 1.86°, respectively. Conclusions: MIS of sacroiliac luxation using 2.3-mm cannulated screws is applicable to toy breed dogs with acceptable difficulty.

Arthroscopic Cannulated Screw Fixation Technique for Avulsion Fracture of the Intercondylar Eminence of the Tibia (삽관 나사못(Cannulated screw)을 사용한 경골 과간 융기부 견열 골절의 관절경적 치료 기법)

  • Lee, Kee-Byoung;Chang, Ho-Guen;Lee, Seok-Beom;Moon, Young-Wan;Kang, Ki-Hoon;Lee, Wook-Hyung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.127-131
    • /
    • 1999
  • Avulsion fractures of the intercondylar eminence of the tibia are not uncommon. In the displaced avulsion fracture, anatomical reduction and firm fixation of fracture fragments are needed but the most of the conventional operative techniques including arthroscopic technique are relatively complex and need. The results were not always satisfactory due to the risk of postoperative complications such as wound infection, premature epiphyseal closure and loss of fixation after early motion etc. So we describe a simple and safe modified method of arthroscopic reduction and fixation for avulsion fractures of the intercondylar eminence of the tibia. In our thirteen cases, we achieved anatomical reduction and secure fixation using cannulated screw through the three arthroscopic portals (anterolateral, medial mid-patellar and central). Postoperatively, immediate limited range of motion of the knee and partial weight bearing were possible. Additional use of the washer afforded safe fixation of comminuted avulsion fracture. The advantage of this technique includes its technical simplicity, easy removal of hardware, ability to treat comminuted type IV fracture with washer, no additional skin incision, no damage to growing plate in growth children and less morbidity.

  • PDF

Pulmonary Embolism after Screw Fixation for a Greater Tubercle Fracture of Humerus

  • Kang, Suk;Chung, Phil Hyun;Kim, Jong Pil;Kim, Young Sung;Lee, Ho Min;Jang, Han Gil
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.4
    • /
    • pp.201-204
    • /
    • 2014
  • Pulmonary embolism is a serious complication, which is well known in patients undergoing total hip or total knee arthroplasty or lower extremity fracture surgery. But, there are few literatures concerning pulmonary embolism after upper extremity surgery. Pulmonary embolism after minor upper extremity fracture surgery is extremely rare. We report a case of 66-year-old female patient that developed pulmonary embolism after percutaneous cannulated screw fixation for a greater tubercle fracture of the proximal humerus with literature review.

Arthroscopic Treatment of Greater Tuberosity fracture - Preliminary Report - (상완골 대결절 골절 손상에 대한 관절경적 치료 -예비 보고-)

  • Ji, Jong-Hoon;Kim, Young-Yul;Park, Sang-Eun;Ra, Ki-Hang;Do, Jeong-Hun;Kim, Weon-Yoo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.1
    • /
    • pp.57-65
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the clinical result of arthroscopic treatments by using suture anchors or suture anchors combined with cannulated screw in the greater tuberosity fracture of the proximal humerus fracture. Materials and Methods: From March 2004 to March 2006 we have used suture anchor or suture anchors combined with cannulated screw for 6 cases of the greater tuberosity fracture which include displaced fractures, comminuted fractures and minimally displaced fractures with comcomittent lesions such as rotator cuff tears, stiffness and labral lesion. In this retrospective study, we analyzed the clinical outcomes by using the range of motion, University of California at Los Angeles shoulder rating scale (UCLA) and the ASES shoulder index score (ASES) in the average 6 months follow up. Results: At the last follow up, average range of motion was improved to 154.3 degree, 145.8 degree, 32.6 degree and L1 vertebrae in each forward flexion, abduction, external rotation and internal rotation. Clinically the UCLA rating scales improved to 31.5 and the ASES shoulder index score (ASES) improved to 93.6 in the last follow up. Conclusion: Arthroscopic treatments by using suture anchor or suture anchors combined with cannulated screw in the greater tuberosity fracture of the proximal humerus fracture is an alternative treatment of the greater tuberosity fracture of the proximal humerus fracture.

  • PDF

Additional axial K-wire Fixation for Proximal Crescentic Metatarsal Osteotomy : A Biomechanical Study (반월형 근위 중족골 절골술에 대한 보강적 축성 K-강선 고정술 : 생체역학적 연구)

  • Jung, Hong-Geun;Kim, You-Jin;Guyton, Gregory
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.2
    • /
    • pp.151-156
    • /
    • 2003
  • Purpose: Proximal crescentic metatarsal osteotomy(PMO) is one of the most common procedures for correcting moderate to severe degree hallux valgus deformity. Although screw fixation is used for osteotomy site stability, loss of reduction can occur. The purpose of this study is to compare the sagittal plane stability of the conventional crescentic PMO fixed with a single screw with that of the crescentic PMO fixed with 1 screw and 2 supplemental K -wires. Material and Methods: Ten matched pairs of cadaveric foot specimens were used for the proximal crescentic metatarsal osteotomy. For one foot specimen of each pair, crescentic osteotomy was fixed with 4mm long threaded cannulated screw, while the matched pair was prepared by adding two axial 1.6mm K-wires to the conventionally fixed 4mm screw. The extensometer was used to measure the osteotomy gap as the metatarsal head was loaded continuously until failure using a servohydraulic MTS Mini Bionix test frame. The strength of fixation was normalized with the bone mineral density (BMD) of the paired specimen $(N{\times}cm^{2}/gm)$, Result: The average strength of the crescentic PMO with axial K-wire fixation ($458.8cm^{2}/gm$, S.D. 434.3) was significantly higher than the standard crescentic PMO ($367.5cm^{2}/gm$, S.D. 397,9) (p=0.05). Conclusion: Supplemental fixation with two axial K-wires can be added to the crescentic PMO to enhance the initial fixation stability to prevent the loss of reduction or dorsal malunion.

  • PDF