• Title/Summary/Keyword: Cancer statistics

Search Result 733, Processing Time 0.032 seconds

Discussion of COVID-19 Vaccination and Axillary Lymph Nodes Uptake in 18F-FDG PET/CT (18F-FDG PET/CT에서 코로나 백신접종과 액와 림프절 섭취에 대한 고찰)

  • Min-Chan, Kim;Yong-Hoon, Choi;Han-Sang, Lim;Jae-Sam, Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.32-36
    • /
    • 2022
  • Purpose There are reports that the COVID-19 vaccine causes false positive uptake of axillary lymph nodes. Therefore, this paper intends to evaluate the change in SUVmax of axillary lymph nodes with the period after the COVID-19 vaccination. Materials and Methods In 134 breast cancer patients who were tested for 18F-FDG PET/CT at Severance hospital, 3.7 MBq/kg of 18F-FDG was intravenously injected and scanned for 2 minutes per bed after 60 minutes. The equipment was Discovery 600 (GE Healthcare, MI, USA). The period was divided into four groups, 0 to 2 weeks, 3 to 6 weeks, 7 to 10 weeks, and 11 weeks or more. SUVmax was measured after checking the uptake of axillary lymph nodes on the ipsilateral side of vaccination and the Kruskal-Wallis test was performed using SPSS Statistics 28 (IBM Corp., Armonk, NY, USA). Results From 0 to 2 weeks groups to 11 weeks or more group, the average of SUVmax was measured in the order of 5.52, 2.85, 1.82, and 1.7. As a result of the Kruskal-Wallis test, there was a significant difference between 0 to 2 weeks group from all other groups (P < 0.05), and there was no significant difference between the remaining three groups. Conclusion The SUVmax of axillary lymph nodes decreased over the period after the COVID-19 vaccination and no significant difference was found after 3 weeks of vaccination. Therefore, it is recommended to record COVID-19 vaccination information before examination.

Analysis of Trends of 'An Investigation on Multicultural Families in Korea' at the Korean Statistical Information Service(KOSIS) (국가통계포털(KOSIS) 『전국다문화가족실태조사』 동향 분석)

  • Chae, eun-hie
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.11
    • /
    • pp.11-20
    • /
    • 2018
  • The Korean Statistical Information Service (KOSIS), classifies and summarizes 1,062 cases that were found when searching [An Investigation on Multicultural Families in Korea] on the website. These years are 2009, 2012, and 2015. The suggestion of this study is as follows. First, it is a comparison between the migrant group and the permanent resident group of 'children' in the research data. Identifying the relative position of a married migrant family to a permanent resident can provide a very important clue. Also, for other date, comparison of the settled and migrant groups is as important as the 'children'. Second, in the 'medical care' category, we need to add more depth than the surface content. For example, the inclusion of details about cancer diagnosis will determine the incidence of marriage migrants. Such efforts can provide more practical assistance to married migrant families. KOSIS is a very useful site that provides useful site that provides us with a lot of information. In the future, they should be able to use migrant group information more efficiently and be more helpful to them. This is the beginning of a sustainable society.

The Association between Pulmonary Function Test Result and Combustible Cigarette Smoking or Electrical Cigarette Smoking in Korean Adults : Using the 2014-2019 Korean national health and nutrition examination survey data (한국 성인에서 일반담배 또는 가열 전자담배를 이용한 흡연 형태와 폐 기능 검사 결과와의 관련성: 2014-2019년도 국민건강영양조사 자료를 이용하여)

  • Il-hwan Kim;Il-Hyun Lee;Sae-Ron Shin
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.1
    • /
    • pp.27-39
    • /
    • 2024
  • Purpose : Smoking is a major factor in chronic obstructive pulmonary disease (COPD), but the effect of electrical cigarette smoking on COPD development is still uncertain. This study aimed to compare the functions of airways and lungs exposed to combustible cigarettes and electrical cigarettes based on the pulmonary function test (PFT) results from the Korean National Health and Nutrition Examination Survey (NHANES). Methods : This study used data from 8,942 participants with PFT results out of 47,309 total subjects from the 6th to 8th Korean NHANES (2014-2015, 2016-2018, and 2019, respectively). Individuals with diseases such as cancer, ex-smokers, and dual tobacco users were excluded. The PFT results were analyzed according to the COPD diagnostic criteria. After adjusting for confounding variables, a complex sample generalized linear model ANOVA test was performed to investigate the association between PFT results and combustible smoker or electrical cigarette user groups. Results : In an analysis based on the obstructive ventilatory disorders (forced expiratory volume in 1 second[FEV1]/forced vital capacity[FVC]<.7), combustible cigarette smokers showed a 3.46 times higher risk of COPD compared to non-smokers, while electrical cigarette smokers exhibited no significant difference in terms of COPD-related risks compared to non-smokers. FEV1 showed a negative relation with combustible cigarette smokers as reported elsewhere (B=-.07, p<.001). FEV1/FVC was negatively related to both combustible cigarette smokers (B=-.03, p<.001) and electrical cigarette smokers (B=-.02, p<.001). Conclusion : FEV1/FVC decreases were observed in the long-term exposure to both combustible and electrical cigarettes. The lower FEV1 in the combustible cigarette group implies the worsening of the severity of COPD, suggesting more damage to the airways and lungs in the short term. Therefore, the temporary electrical cigarettes use for the transition period in order to smoking cessation potentially aids to reduce the harmful effect of combustible cigarettes in COPD development.

Imaging-Based Versus Pathologic Survival Stratifications of Diffuse Glioma According to the 2021 WHO Classification System

  • So Jeong Lee;Ji Eun Park;Seo Young Park;Young-Hoon Kim;Chang Ki Hong;Jeong Hoon Kim;Ho Sung Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.772-783
    • /
    • 2023
  • Objective: Imaging-based survival stratification of patients with gliomas is important for their management, and the 2021 WHO classification system must be clinically tested. The aim of this study was to compare integrative imaging- and pathology-based methods for survival stratification of patients with diffuse glioma. Materials and Methods: This study included diffuse glioma cases from The Cancer Genome Atlas (training set: 141 patients) and Asan Medical Center (validation set: 131 patients). Two neuroradiologists analyzed presurgical CT and MRI to assign gliomas to five imaging-based risk subgroups (1 to 5) according to well-known imaging phenotypes (e.g., T2/FLAIR mismatch) and recategorized them into three imaging-based risk groups, according to the 2021 WHO classification: group 1 (corresponding to risk subgroup 1, indicating oligodendroglioma, isocitrate dehydrogenase [IDH]-mutant, and 1p19q-codeleted), group 2 (risk subgroups 2 and 3, indicating astrocytoma, IDH-mutant), and group 3 (risk subgroups 4 and 5, indicating glioblastoma, IDHwt). The progression-free survival (PFS) and overall survival (OS) were estimated for each imaging risk group, subgroup, and pathological diagnosis. Time-dependent area-under-the receiver operating characteristic analysis (AUC) was used to compare the performance between imaging-based and pathology-based survival model. Results: Both OS and PFS were stratified according to the five imaging-based risk subgroups (P < 0.001) and three imaging-based risk groups (P < 0.001). The three imaging-based groups showed high performance in predicting PFS at one-year (AUC, 0.787) and five-years (AUC, 0.823), which was similar to that of the pathology-based prediction of PFS (AUC of 0.785 and 0.837). Combined with clinical predictors, the performance of the imaging-based survival model for 1- and 3-year PFS (AUC 0.813 and 0.921) was similar to that of the pathology-based survival model (AUC 0.839 and 0.889). Conclusion: Imaging-based survival stratification according to the 2021 WHO classification demonstrated a performance similar to that of pathology-based survival stratification, especially in predicting PFS.

Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study

  • Kyung Hee Lee;Kun Young Lim;Young Joo Suh;Jin Hur;Dae Hee Han;Mi-Jin Kang;Ji Yung Choo;Cherry Kim;Jung Im Kim;Soon Ho Yoon;Woojoo Lee;Chang Min Park
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1300-1310
    • /
    • 2019
  • Objective: To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in a multi-institutional setting. Materials and Methods: A total of 9384 initial PTNBs performed in 9239 patients (mean patient age, 65 years [range, 20-99 years]) from January 2010 to December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PTNBs for diagnosis of malignancy were measured. The proportion of diagnostic failures was measured, and their risk factors were identified. Results: The overall accuracy, sensitivity, specificity, PPV, and NPV were 91.1% (95% confidence interval [CI], 90.6-91.7%), 92.5% (95% CI, 91.9-93.1%), 86.5% (95% CI, 85.0-87.9%), 99.2% (95% CI, 99.0-99.4%), and 84.3% (95% CI, 82.7-85.8%), respectively. The proportion of diagnostic failures was 8.9% (831 of 9384; 95% CI, 8.3-9.4%). The independent risk factors for diagnostic failures were lesions ≤ 1 cm in size (adjusted odds ratio [AOR], 1.86; 95% CI, 1.23-2.81), lesion size 1.1-2 cm (1.75; 1.45-2.11), subsolid lesions (1.81; 1.32-2.49), use of fine needle aspiration only (2.43; 1.80-3.28), final diagnosis of benign lesions (2.18; 1.84-2.58), and final diagnosis of lymphomas (10.66; 6.21-18.30). Use of cone-beam CT (AOR, 0.31; 95% CI, 0.13-0.75) and conventional CT-guidance (0.55; 0.32-0.94) reduced diagnostic failures. Conclusion: The accuracy of PTNB for diagnosis of malignancy was fairly high in our large-scale multi-institutional cohort. The identified risk factors for diagnostic failure may help reduce diagnostic failure and interpret the biopsy results.

Association between Initial Chest CT or Clinical Features and Clinical Course in Patients with Coronavirus Disease 2019 Pneumonia

  • Zhe Liu;Chao Jin;Carol C. Wu;Ting Liang;Huifang Zhao;Yan Wang;Zekun Wang;Fen Li;Jie Zhou;Shubo Cai;Lingxia Zeng;Jian Yang
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.736-745
    • /
    • 2020
  • Objective: To identify the initial chest computed tomography (CT) findings and clinical characteristics associated with the course of coronavirus disease 2019 (COVID-19) pneumonia. Materials and Methods: Baseline CT scans and clinical and laboratory data of 72 patients admitted with COVID-19 pneumonia (39 men, 46.2 ± 15.9 years) were retrospectively analyzed. Baseline CT findings including lobar distribution, presence of ground glass opacities, consolidation, linear opacities, and lung severity score were evaluated. The outcome event was recovery with hospital discharge. The time from symptom onset to discharge or the end of follow-up (for those remained hospitalized) was recorded. Data were censored in events such as death or discharge without recovery. Multivariable Cox proportional hazard regression was used to explore the association between initial CT, clinical or laboratory findings, and discharge with recovery, whereby hazard ratio (HR) values < 1 indicated a lower rate of discharge at four weeks and longer time until discharge. Results: Thirty-two patients recovered and were discharged during the study period with a median length of admission of 16 days (range, 9 to 25 days), while the rest remained hospitalized at the end of this study (median, 17.5 days; range, 4 to 27 days). None died during the study period. After controlling for age, onset time, lesion characteristics, number of lung lobes affected, and bilateral involvement, the lung severity score on baseline CT (> 4 vs. ≤ 4 [reference]: adjusted HR = 0.41 [95% confidence interval, CI = 0.18-0.92], p = 0.031) and initial lymphocyte count (reduced vs. normal or elevated [reference]: adjusted HR = 0.14 [95% CI = 0.03-0.60], p = 0.008) were two significant independent factors that influenced recovery and discharge. Conclusion: Lung severity score > 4 and reduced lymphocyte count at initial evaluation were independently associated with a significantly lower rate of recovery and discharge and extended hospitalization in patients admitted for COVID-19 pneumonia.

A Study on the Quality of Healthcare Services for Four Critical Illnesses and the Maintenance of Right to Protection and Dignity in a Senior General Hospital (상급종합병원의 4대 중증질환 의료 서비스 품질과 보호받을 권리 및 존엄성 유지에 관한 연구)

  • Woojin Lee;Minsuk Shin
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.4
    • /
    • pp.531-550
    • /
    • 2023
  • Purpose: The unique nature of life-and-death healthcare services sets them apart from other service industries. While many studies exist on the relationship between healthcare services and customer satisfaction, most of them focus on mildly ill patients, ignoring the differences between critically ill and non-seriously ill patients. This study discusses the actual quality of healthcare services for patients who are facing life-threatening illnesses and are on life support, as well as their right to protection and dignity. Methods: The survey conducted to 149 patients with the four major illnesses: cancer, heart disease, brain disease and rare and incurable disease, those who have experiences with senior general hospitals. Results: The basic statistics of this study are adequate to represent the four major critical illnesses, and the reliability and validity of this study's hypotheses, which were measured by multiple items, were analyzed, and the internal consistency was judged to be high. In addition, it was found that the convergent validity was good and the discriminant validity was also secured. When examining the goodness of fit of the hypotheses, the SRMR, which is the standardized root mean square of residuals that measures the difference between the covariance matrix of the data variables and the theoretical covariance matrix structure of the model, met the optimal criteria. Conclusion: The academic implications of this study are differentiated from other studies by moving away from evaluating the quality of healthcare services for mildly ill patients and focusing on the rights and dignity of patients with life-threatening illnesses in four senior general hospitals. In terms of academic implications, this study enriches the depth of related studies by demonstrating the right to protection and dignity as a factor of patient-centeredness based on physical environment quality, interaction quality, and outcome quality, which are presented as sub-factors of healthcare quality. We found that the three quality factors classified by Brady and Cronin (2001) are optimized for healthcare quality assessment and management, and that the results of patients' interaction quality assessment can be used to provide a comprehensive quality rating for hospitals. Health and human rights are inextricably linked, so assessing the degree to which rights and dignity are protected can be a superior and more comprehensive measurement tool than traditional health level measures for healthcare organizations. Practical implications: Improving the quality of the physical environment and the quality of outcomes is an important challenge for hospital managers who attract patients with life and death conditions, but given the scale and economics of time, money, and human inputs, improving the quality of interactions and defining them as performance indicators in hospital quality management is an efficient way to create maximum value in the short term.

Statistical Errors in Papers Published in the Journal of the Korean Society for Therapeutic Radiology and Oncology (대한방사선종양학회지 게재 논문의 통계적 오류 현황)

  • Park, Hee-Chul;Choi, Doo-Ho;Ahn, Song-Vogue;Kang, Jin-Oh;Kim, Eun-Seog;Park, Won;Ahn, Seung-Do;Yang, Dae-Sik;Yun, Hyong-Geun;Chung, Eun-Ji;Chie, Eui-Kyu;Pyo, Hong-Ryull;Hong, Se-Mie
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.289-294
    • /
    • 2008
  • Purpose: To improve the quality of the statistical analysis of papers published in the Journal of the Korean Society for Therapeutic Radiology and Oncology (JKOSTRO) by evaluating commonly encountered errors. Materials and Methods: Papers published in the JKOSTRO from January 2006 to December 2007 were reviewed for methodological and statistical validity using a modified version of Ahn's checklist. A statistician reviewed individual papers and evaluated the list items in the checklist for each paper. To avoid the potential assessment error by the statistician who lacks expertise in the field of radiation oncology; the editorial board of the JKOSTRO reviewed each checklist for individual articles. A frequency analysis of the list items was performed using SAS (version 9.0, SAS Institute, NC, USA) software. Results: A total of 73 papers including 5 case reports and 68 original articles were reviewed. Inferential statistics was used in 46 papers. The most commonly adopted statistical methodology was a survival analysis (58.7%). Only 19% of papers were free of statistical errors. Errors of omission were encountered in 34 (50.0%) papers. Errors of commission were encountered in 35 (51.5%) papers. Twenty-one papers (30.9%) had both errors of omission and commission. Conclusion: A variety of statistical errors were encountered in papers published in the JKOSTRO. The current study suggests that a more thorough review of the statistical analysis is needed for manuscripts submitted in the JKOSTRO.

A Web-based 'Patterns of Care Study' System for Clinical Radiation Oncology in Korea: Development, Launching, and Characteristics (우리나라 임상방사선종양을 위한 웹 기반 PCS 시스템의 개발과 특성)

  • Kim, Il Han;Chie, Eui Kyu;Oh, Do Hoon;Suh Chang-Ok;Kim, Jong Hoon;Ahn, Yong Chan;Hur, Won-Joo;Chung, Woong Ki;Choi, Doo Ho;Lee, Jae Won
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.291-298
    • /
    • 2003
  • Purpose: We report upon a web-based system for Patterns of Care Study (PCS) devised for Korean radiation oncology. This PCS was designed to establish standard tools for clinical quality assurance, to determine basic parameters for radiation oncology processes, to offer a solid system for cooperative clinical studies and a useful standard database for comparisons with other national databases. Materials and Methods: The system consisted of a main server with two back-ups in other locations. The program uses a Linux operating system and a MySQL database. Cancers with high frequencies in radiotherapy departments in Korea from 1998 to 1999 were chosen to have a developmental priority. Results: The web-based clinical PCS .system for radiotherapy in www.pcs.re.kr was developed in early 2003 for cancers of the breast, rectum, esophagus, larynx and lung, and for brain metastasis. The total number of PCS study items exceeded one thousand. Our PCS system features user-friendliness, double entry checking, data security, encryption, hard disc mirroring, double back-up, and statistical analysis. Alphanumeric data can be input as well as image data. In addition, programs were constructed for IRB submission, random sampling of data, and departmental structure. Conclusion: For the first time in the field of PCS, we have developed a web-based system and associated working programs. With this system, we can gather sample data in a short period and thus save, cost, effort and time. Data audits should be peformed to validate input data. We propose that this system should be considered as a standard method for PCS or similar types of data collection systems.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF