• Title/Summary/Keyword: Cancer patients

Search Result 10,433, Processing Time 0.052 seconds

The Effect of 131I Therapy by Taking in Laxatives (방사성요오드 치료 시 완하제 투여 효과)

  • Kil, Sang-Hyeong;LEE, Hyo-Yeong;Park, Kwang-Yeol;Jo, Kyung-Nam;Baek, Seung-Jo;Hwang, Kyo-Min;Cho, Seong-Mook;Choi, Jae-Hyeok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.3-9
    • /
    • 2014
  • Purpose: Our goals were to evaluate the effect of high dose radioiodine treatment for thyroid cancer by taking in laxatives. Materials and Methods: Twenty patients(M:F=13:7, age $46.3{\pm}8.1\;yrs$) who underwent high dose radioiodine treatment were seperated into Group 1 taking $^{131}I$ 5,500 MBq and Group 2 with the use of laxatives after taking $^{131}I$ 5,500 MBq. The whole body was scanned 16 hours and 40 hours after taking radioactive iodines by using gamma camera, the ROIs were drawn on the gastro-intestinal tract and thigh for calculation of reduction ratio. At particular time during hospitalization, the radioactivity remaining in the body was measured in 1 meter from patient by using survey meter (RadEye-G10, Thermo Fisher Scientific, USA). Schematic presentation of an Origin 8.5.1 software was used for spatial dose rate. Statistical comparison between groups were done using independent samples t-test. P value less than 0.05 was regarded as statistically significant. Results: The reduction ratio in gastro-intestinal 16 hours and 40 hours after taking laxatives is $42.1{\pm}6.3%$ in Group 1 and $72.1{\pm}6.4%$ in Group 2. The spatial dose rate measured when discharging from hospital was $23.8{\pm}6.7{\mu}Sv/h$ in Group 1 and $8.2{\pm}2.4{\mu}Sv/h$ in Group 2. The radioactivity remaining in the body is much decreased at the patient with laxatives(P<0.05). Conclusion: The use in combination with laxatives is helpful for decreasing radioactivity remaining in the body. The radioactive contamination could be decreased at marginal individuals from patients.

  • PDF

Platelet count change by vincristine in maintenance phase of acute lymphoblastic leukemia chemotherapy (급성 림프구성 백혈병의 항암 유지요법 중 vincristine과 관련된 혈소판수의 변화)

  • Lee, Sung Moon;Ham, Soon Shik;Jeon, In-sang
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.2
    • /
    • pp.181-186
    • /
    • 2006
  • Purpose : The hematologic change during the treatment of acute lymphoblastic leukemia(ALL) is critical as a prognostic determinant and a variable to determine the dose of chemotherapeutic agents. It is known that the dose of vincristine used in the maintenance phase of ALL is small enough to increase the count of platelet. To investigate the change of platelet count according to the vincristine administration in maintenance phase of ALL chemotherapy, we performed this study. Methods : Eleven patients eligible under the criteria of Children's Cancer Study Group(CCG)-1882 and who had completed chemotherapy were enrolled in this study. The count of platelets before vincristine administration was compared with those of vincristine administration 1, 2 and 3 weeks after the early and last periods of maintenance phases. The platelet count before vincristine administration was defined as 100 percent and that after vincristine were compared. In addition, we tentatively defined an enhancing effect of vincristine as positive when the relative count was more than 120 percent. Results : Platelet count did not differ according to the early and last periods of maintenance phase. Platelet count at first week after vincristine administration increased more significantly than that before vincristine in early and last periods. There was an enhancing effect in 10(90.9 percent) of 11 patients after 1 week vincristine administration both in the early and last periods of the maintenance phase. Conclusion : Vincristine, used in ALL maintenance phases as a low dose, increased platelet count 1 week after administration. The increased platelet count resumed to the previous level 2-3 weeks later. However, the thrombocytosis observed in the maintenance phase by vincristine was not high enough to induce thrombosis. In addition, vincristine is known to reduce the activity of platelets. Therefore, the risk of thrombosis in the maintenance phase of ALL chemotherapy would be low.

Evaluation of Manufactured Device for Radiation therapy in Head and Neck Cancer (두경부암 환자의 방사선 치료시 자체 제작한 고정용구 (Shoulder Retractor)에 대한 유용성 평가)

  • Kim, Tae Jun;Jin, Sun Sik;Kim, Dong Hyun;Kim, Dong Wook;Chung, Weon Kuu;Kim, Kyoung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.99-105
    • /
    • 2014
  • Purpose : We compared the set-up accuracy and right-left Shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Materials and Methods : Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. Results : The position variation correction of left (right) Shoulder after image guidance were $1.07{\pm}3.99mm$ ($-4.35{\pm}2.09mm$), $-0.37{\pm}5.91mm$ ($1.26{\pm}5.28mm$), $-0.63{\pm}2.44mm$ ($0.25{\pm}1.61mm$) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were $-2.06{\pm}2.68$, $-1.11{\pm}8.15$, $0.34{\pm}3.78mm$, and $0.51{\pm}0.77$ degree for group A, $-1.18{\pm}1.82$, $-0.94{\pm}2.13$, $-0.67{\pm}1.98mm$, and $0.91{\pm}1.04$ degree for group B and $0.12{\pm}2.18$, $-0.79{\pm}2.64$, $0.79{\pm}2.64$, and $0.00{\pm}0.49$ degree for group C. Conclusion : In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment.

A Long-term Follow up Study on Pulmonary Function after Lobectomy and Pneumonectomy (폐절제술 후 폐환기능의 변화에 대한 장기 추적관찰)

  • Lee, Yi-Hyeong;Kim, Se-Kyu;Chang, Joon;Chung, Kyung-Young;Ahn, Chul-Min;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.6
    • /
    • pp.638-645
    • /
    • 1993
  • Objectives: The functional effects of pulmonary resection are dependent on the preexisting function of resected and remaining tissue as well as on the compensatory potential of the remaining tissue. Nowadays, large pulmonary resections are usually applied to lung cancer patients often already compromised by chronic lung disease. It is important to evaluate the pulmonary reserve after lung resection preoperatively in the decision of operability and extent of resection. The aim of this study was to evaluate the changes of pulmonary function after pulmonary resection. Methods: 8 lobectomized and 8 pneumonectomized patients were evaluated. The pulmonary function test was performed preoperatively and in immediate postoperative period and thereafter to 5 years at 3 months interval. Results: 1) The pulmonary function 1 week after operation was significantly low compared with predicted values in, lobectomy and pneumonectomy groups(p<0.05), and improved closely to their predicted values 3 months after operation. 2) The FVC was maintained above predicted value at 6-24 months and similar to predicted value thereafter in lobectomy group. In pneumonectomy group, the FVC maintained similar to predicted value at 6-36 months and improved above its predicted value thereafter. 3) The FEV1 was maintained similar to their predicted values from 6 months to 5 years after operation in both groups. 4) The FEV1/FVC did not change in the course of time in both groups. 5) The FEF25-75% was maintained similar to predicted value at 6-60 months after operation in lobectomy group, but it decreased under predicted value after 1 year in pneumonectomy group. 6) The MVV was maintained similar to predicted value at 6-24 months and decrease thereafter in lobectomy group. In pneumonectomy group, the MVV was maintained at 6-60 months after operation. 7) The differeces in the pulmonary function(FVC, FEV1, FEF25-75%, MVV) between two groups were seen only at 6 months after operation(p<0.05). Conclusion: The pulmonary function was markedly decreased immediately after operation, improved similar to predicted value at 1-3 months, highest at 6 months, and maintained similar to the predicted value to 5 years after pulmonary resection. The difference in the pulmonary function between two groups was the most at 6 months after operation.

  • PDF

Development of Devices for Improving the Reducibility of Patient Positioning on a Breast Board (Breast Board를 이용한 방사선치료에서 환자 위치 재현성 향상 방안에 대한 연구)

  • Huh Soon Nyung;Cho Woong;Park Yang Kyun;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.123-130
    • /
    • 2005
  • Purpose: We wanted to improve the setup reproducibility of breast cancer patients when utilizing a commercially available breast board for radiation therapy. The breast board was modified by using a new head rest and 2 types of board fixation devices. Materials and Methods: A conventional head/neck rest was modified to be positioned in various slots of the breast board, and it was fabricated 1 cm thinner to provide more comfort to a patient when the patient's neck was rotated. This rest improves the uncertainty of the daily setup. Also, the sagging problems at the left and right sides became negligible with the two types of board fixation devices: (1) the stair type, and (2) the arm type. The first device consists of an upper/lower holder with 4 stair-types of grooves and 4 rectangular Inserts. In order to cover the whole range of vertical setup of the breast board, 4 rectangular inserts were needed, and each covered 10 steps. The arm-type fixation device was also fabricated and attached to the breast board, It had two aluminum bars that were fixed by utilizing a lock-type of screw. These devises were evaluated with two volunteers in order to prove the effectiveness of the improved setup accuracy. Results; The developed cranio-caudal fixation device demonstrated that it could reduce the cranio-caudal error by nearly $55\%$ compared to the old device. As for left-and-right inclination, the stair-type and arm-type fixation devices can reduce the relative inclination by nearly $80\%$ and $90\%$, respectively, compared to the breast board without the fixation device. Conclusion: It was verified that the developed devices were effective for positioning the patients and for avoiding inclination of the breast board.

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

A Study on IMRT (Intensity Modulated Radiation Therapy) Delivery Technique and FFF (Flattening Filter Free) Beam to Increase Skin Dose to Irregularly Shaped Skin Surface. (IMRT(Intensity Modulated Radiation Therapy)전달 기법과 FFF(Flattening Filter Free) 빔을 이용한 요철 부위 피부 선량 증가 방법에 대한 고찰)

  • Woo Heon;Son Sang Jun;Je Young Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.7-12
    • /
    • 2022
  • Purpose: When it is difficult to secure the skin dose when treating Irregularly Shaped Skin Surface such as the nose where it is difficult to apply a bolus, increase the skin dose with a treatment plan that combines the IMRT (Intensity Modulated Radiation Therapy) delivery technique and FFF (Flattening Filter Free), It was tried to find out whether or not through the phantom experiment. Materials & Methods: Based on the 6MV-FF (Flattening Filter) and VMAT (Volumetric-Modulated Arc Therapy) treatment plans, which are the most commonly used treatment plans for head and neck cancer, A comparison group was created by combining VMAT and IMRT, FF and FFF, and the presence or absence of 5 mm bolus application. A virtual target was created on the Rando Phantom's nose, and a virtual bolus of 5 mm was applied assuming full contact on the Rando Phantom's nose. Five measurement points were determined based on the phantom's nose, and the absorbed dose was measured by irradiating each treatment plan 3 times per treatment plan according to the treatment technique and whether or not the bolus was applied. Result: The difference in skin dose in FF vs FFF increased in the case of FFF in VMAT bolus off, and there was no difference in case of IMRT bolus off. In VMAT bolus 5 mm and IMRT bolus 5 mm, it was confirmed that the skin dose was rather decreased in FFF. The difference in skin dose between VMAT and IMRT increased only in the case of FFF bolus off, and there was no statistical difference in the rest. For the difference in skin dose between bolus off vs bolus 5 mm, it was confirmed that the skin dose increased at bolus 5 mm, except for the case of using IMRT FFF. The treatment plan combining IMRT and FFF did not find any statistically significant difference as a result of analyzing the measured values of the treatment plan skin dose applied with a 5 mm bolus using the commonly used VMAT and FF. Therefore, it is thought that by using IMRT_FFF, it is possible to deliver a skin dose similar to that of applying a 5 mm bolus to VMAT_FF, which can be useful for patients who need a high skin dose but have difficulty applying a bolus. Conclusion: For patients who find it difficult to apply bolus, an increase in skin dose can be expected with a treatment plan that properly combines IMRT and FFF compared to VMAT and FF.

Development of an Eye Patch-Type Biosignal Measuring Device to Measure Sleep Quality (수면의 질을 측정하기 위한 안대형 생체신호 측정기기 개발)

  • Changsun Ahn;Jaekwan Lim;Bongsu Jung;Youngjoo Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.5
    • /
    • pp.171-180
    • /
    • 2023
  • The three major sleep disorders in Korea are snoring, sleep apnea, and insomnia. Lack of sleep is the root of all diseases. Some of the most serious potential problems associated with sleep deprivation are cardiovascular problems, cognitive impairment, obesity, diabetes, colitis, prostate cancer, etc. To solve these problems, the Korean government provided low-cost national health insurance benefits for polysomnography tests in July 2018. However, insomnia patients still have problems getting treated in terms of time, space, and economic perspectives. Therefore, it would be better for insomnia patients to be allowed to test at home. The measuring device can measure six biosignals (eye movement, tossing and turning, body temperature, oxygen saturation, heart rate, and audio). A gyroscope sensor (MPU9250, InvenSense, USA) was used for eye movement, tossing, and turning. The input range of the sensor was in 258°/sec to 460°/sec, and the data range was in the input range. Body temperature, oxygen saturation range, and heart rate were measured by a sensor (MAX30102, Analog Devices, USA). The body temperature was measured in 30 ℃ to 45 ℃, and the oxygen saturation range was 0% for the unused state and 20 % to 90 % for the used state. The heart rate measurement range was in 40 bpm to 180 bpm. The measurement of audio signal was performed by an audio sensor (AMM2742-T-R, PUIaudio, USA). The was -42 dB ±1 dB frequency range was 20 Hz to 20 kHz. The measured data was successfully received in wireless network conditions. The system configuration was consisted of a PC and a mobile app for bio-signal measurement and data collection. The measured data was collected by mobile phones and desktops. The data collected can be used as preliminary data to determine the stage of sleep and perform the screening function for sleep induction and sleep disturbances. In the future, this convenient sleep measurement device could be beneficial for treating insomnia.

Diagnostic Approach to the Solitary Pulmonary Nodule : Reappraisal of the Traditional Clinical Parameters for Differentiating Malignant Nodule from Benign Nodule (고립성 폐결절에 대한 진단적 접근 : 악성결절과 양성결절의 감별 지표에 대한 재검토)

  • Kho, Won Jung;Kim, Cheol Hyeon;Jang, Seung Hun;Lee, Jae Ho;Yoo, Chul Gyu;Chung, Hee Soon;Kim, Young Whan;Han, Sung Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.500-518
    • /
    • 1996
  • Background : The solitary pulmonary nodule(SPN) presents a diagnostic dilemma to the physician and the patient. Many clinical characteristics(i.e. age, smoking history, prior history of malignancy) and radiological characteristics( i.e. size, calcification, growth rate, several findings of computed tomography) have been proposed to help to determine whether the SPN was benign or malignant. However, most of these diagnostic guidelines are based on the data collected before computed tomography(CT) has been introduced and lung cancer was not as common as these days. Moreover, it is not well established whether these guidelines from western populations could be applicable to Korean patients. Methods : We had a retrospective analysis of the case records and radiographic findings in 114 patients presenting with SPN from Jan. 1994 to Feb. 1995 in Seoul National University Hospital, a tertiary referral hospital. Results : We observed the following results ; (1) Out of 113 SPNs, the etiology was documented in 94 SP IS. There were 34 benign SP s and 60 malignant SPNs. Among which, 49 SPNs were primary lung cancers and the most common hi stologic type was adenocarcinoma. (2) The average age of patients with benign and malignant SPNs was $49.7{\pm}12.0$ and $58.1{\pm}10.0$ years, respectively( p=0.0004), and the malignant SPNs had a striking linear propensity to increase with age. (3) No significant difference in the hi story of smoking was noted between the patients with benign SPNs($13.0{\pm}17.6$ pack- year) and those with malignant SPNs($18.6{\pm}25.1$ pack-year) (p=0.2108). (4) 9 out of 10 patients with prior history of malignancy had malignant SPNs. 5 were new primary lung cancers with no relation to prior malignancy. (5) The average size of benign SPNs($3.01{\pm}1.20cm$) and malignant SPNs($2.98{\pm}0.97cm$) was not significantly different(p=0.8937). (6) The volume doubling time could be calculated in 22 SPNs. 9 SPNs had the volume doubling time longer than 400 days. Out of these, 6 were malignant SPNs. (7) The CT findings suggesting malignancy included the lobulated or spiculated border, air- bronchogram, pleural tail, and lymphadenopathy. In contrast, calcification, central low attenuation, cavity with even thickness, well-marginated border, and peri nodular micronodules were more suggestive for benign nodule. (8) The diagnostic yield of percutaneous needle aspiration and biopsy was 57.6%(19/33) of benign SPNs and 81.0%(47/58) of malignant SPNs. The diagnostic value of sputum analysis and bronchoscopic evaluations were relatively very low. (9) 42.3%(11/26) of SPNs of undetermined etiology preoperatively turned out to be malignant after surgical resection. Overall, 75.4%(46/61) of surgically resected SPNs were malignant. Conclusions : We conclude that the likelihood of malignant SPN correlates the age of patient, prior history of malignancy, some CT findings including lobulated or spiculated border, air-bronchogram, pleural tail and lymphadenopathy. However, the history of smoking, the size of the nodule, and the volume doubling time are not helpful to determent whether the SPN is benign or malignant, which have been regarded as valuable clinical parameters previously. We suggest that aggressive diagnostic approach including surgical resection is necessary in patient with SPNs.

  • PDF

Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode (호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용)

  • Kim, Sung Ki;Lim, Hhyun Sil;Kim, Wan Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • Purpose : This study has already started commercial Gated RapidArc automation equipment which was not previously in the Gated radiation therapy can be performed simultaneously with the VMAT Gated RapidArc radiation therapy to the accuracy of the analysis to evaluate the usability, Amplitude mode applied to the patient. Materials and Methods : The analysis of the distribution of radiation dose equivalent quality solid water phantom and GafChromic film was used Film QA film analysis program using the Gamma factor (3%, 3 mm). Three-dimensional dose distribution in order to check the accuracy of Matrixx dosimetry equipment and Compass was used for dose analysis program. Periodic breathing synchronized with solid phantom signals Phantom 4D Phantom and Varian RPM was created by breathing synchronized system, free breathing and breath holding at each of the dose distribution was analyzed. In order to apply to four patients from February 2013 to August 2013 with liver cancer targets enough to get a picture of 4DCT respiratory cycle and then patients are pratice to meet patient's breathing cycle phase mode using the patient eye goggles to see the pattern of the respiratory cycle to be able to follow exactly in a while 4DCT images were acquired. Gated RapidArc treatment Amplitude mode in order to create the breathing cycle breathing performed three times, and then at intervals of 40% to 60% 5-6 seconds and breathing exercises that can not stand (Fig. 5), 40% While they are treated 60% in the interval Beam On hold your breath when you press the button in a way that was treated with semi-automatic. Results : Non-respiratory and respiratory rotational intensity modulated radiation therapy technique absolute calculation dose of using computerized treatment plan were shown a difference of less than 1%, the difference between treatment technique was also less than 1%. Gamma (3%, 3 mm) and showed 99% agreement, each organ-specific dose difference were generally greater than 95% agreement. The rotational intensity modulated radiation therapy, respiratory synchronized to the respiratory cycle created Amplitude mode and the actual patient's breathing cycle could be seen that a good agreement. Conclusion : When you are treated Non-respiratory and respiratory method between volumetric intensity modulated radiation therapy rotation of the absolute dose and dose distribution showed a very good agreement. This breathing technique tuning volumetric intensity modulated radiation therapy using a rotary moving along the thoracic or abdominal breathing can be applied to the treatment of tumors is considered. The actual treatment of patients through the goggles of the respiratory cycle to create Amplitude mode Gated RapidArc treatment equipment that does not automatically apply to the results about 5-6 seconds stopped breathing in breathing synchronized rotary volumetric intensity modulated radiation therapy facilitate could see complement.