• Title/Summary/Keyword: Cancer patients

Search Result 10,735, Processing Time 0.046 seconds

Prostate Volume Measurement by TRUS Using Heights Obtained by Transaxial and Midsagittal Scanning: Comparison with Specimen Volume Following Radical Prostatectomy

  • Sung Bin Park;Jae Kyun Kim;Sung Hoon Choi;Han Na Noh;Eun Kyung Ji;Kyoung Sik Cho
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.110-113
    • /
    • 2000
  • Objective: The purpose of this study was to determine, when measuring prostate volume by TRUS, whether height is more accurately determined by transaxial or midsagittal scanning. Materials and Methods: Sixteen patients who between March 1995 and March 1998 underwent both preoperative TRUS and radical prostatectomy for prostate cancer were included in this study. Using prolate ellipse volume calculation (height × length × width × 𝜋/6), TRUS prostate volume was determined, and was compared with the measured volume of the specimen. Results: Prostate volume measured by TRUS, regardless of whether height was determined transaxially or midsagittally, correlated closely with real specimen volume. When height was measured in one of these planes, a paired t test revealed no significant difference between TRUS prostate volume and real specimen volume (p = .411 and p = .740, respectively), nor were there significant differences between the findings of transaxial and midsagittal scanning (p = .570). A paired sample test, however, indicated that TRUS prostate volumes determined transaxially showed a higher correlation coefficient (0.833) and a lower standard deviation (9.04) than those determined midsagittally (0.714 and 11.48, respectively). Conclusion: Prostate volume measured by TRUS closely correlates with real prostate volume. Furthermore, we suggest that when measuring prostate volume in this way, height is more accurately determined by transaxial than by midsagittal scanning.

  • PDF

Therapeutic Effect of Crocin in Inflammatory Diseases (염증성 질환에 대한 Crocin의 치료 효과)

  • YoungHee Kim
    • Journal of Life Science
    • /
    • v.34 no.2
    • /
    • pp.138-144
    • /
    • 2024
  • Crocin is a major carotenoid of the Gardenia jasminoides fruit and Crocus sativus stigma (saffron), which are used in various cuisines as flavoring and coloring agents, as well as in phytomedicine for the treatment of several disorders, including headache, fever, edema, fatty liver, viral hepatitis, respiratory disease, menstruation disorders, insomnia, and hypertension. Crocin (C44H64O24) is a chemical diester composed of the dicarboxylic acid crocetin and disaccharide gentiobiose. Many in vitro and in vivo studies have been conducted about the biological and pharmacological function and toxicity of crocin. Crocin has been revealed to have no genotoxicity and pathological manifestation. Crocin acts as an antioxidant, anti-cancer, memory enhancer, anxiolytic, antidepressant, aphrodisiac, anti-atherosclerotic, cardioprotector, and hepatoprotector. Here, an inclusive review of crocin is introduced based on previously explored studies referred to in the literature. Different studies have confirmed the protective role of crocin in the pathogenesis of inflammatory diseases, including inflammatory bowel diseases, gastritis, asthma, atherosclerosis, rheumatoid arthritis, multiple sclerosis, type 1 diabetes, Alzheimer's disease, Parkinson's disease, and depression. It is surmised that crocin suppresses inflammatory, antioxidant, and apoptotic processes through multiple mechanisms. Crocin is considered a safe and effective therapeutic choice for patients with inflammatory conditions, although more research investigating its mechanisms and results acquired in clinical trials are needed.

Typical and Atypical Imaging Features of Malignant Lymphoma in the Abdomen and Mimicking Diseases (복부 악성 림프종의 영상 소견 및 비슷한 소견을 보일 수 있는 질병들)

  • Jong Eun Kim;So Hyun Park;Young Sup Shim;Sungjin Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1266-1289
    • /
    • 2023
  • Malignant lymphoma typically presents with homogeneous enhancement of enlarged lymph nodes without internal necrotic or cystic changes on multiphasic CT, which can be suspected without invasive diagnostic methods. However, some subtypes of malignant lymphoma show atypical imaging features, which makes diagnosis challenging for radiologists. Moreover, there are several lymphoma-mimicking diseases in current clinical practice, including leukemia, viral infections in immunocompromised patients, and primary or metastatic cancer. The ability of diagnostic processes to distinguish malignant lymphoma from mimicking diseases is necessary to establish effective management strategies for initial radiological examinations. Therefore, this study aimed to discuss the typical and atypical imaging features of malignant lymphoma as well as mimicking diseases and discuss important diagnostic clues that can help narrow down the differential diagnosis.

Dosimetric Analysis of Lung Stereotactic Body Radiotherapy Using Halcyon Linear Accelerator

  • Shinhaeng Cho;Ick Joon Cho;Yong Hyub Kim;Jea-Uk Jeong;Mee Sun Yoon;Taek-Keun Nam;Sung-Ja Ahn;Ju-Young Song
    • Progress in Medical Physics
    • /
    • v.34 no.4
    • /
    • pp.48-54
    • /
    • 2023
  • Purpose: In this study, the dosimetric characteristics of lung stereotactic body radiotherapy (SBRT) plans using the new Halcyon system were analyzed to assess its suitability. Methods: We compared the key dosimetric parameters calculated for the Halcyon SBRT plans with those of a conventional C-arm linear accelerator (LINAC) equipped with a high-definition multileaf collimator (HD-MLC)-Trilogy Tx. A total of 10 patients with non-small-cell lung cancer were selected, and all SBRT plans were generated using the RapidArc technique. Results: Trilogy Tx exhibited significant superiority over Halcyon in terms of target dose coverage (conformity index, homogeneity index, D0.1 cc, and D95%) and dose spillage (gradient). Trilogy Tx was more efficient than Halcyon in the lung SBRT beam delivery process in terms of the total number of monitor units, modulation factor, and beam-on time. However, it was feasible to achieve a dose distribution that met SBRT plan requirements using Halcyon, with no significant differences in satisfying organs at risk dose constraints between both plans. Conclusions: Results confirm that Halcyon is a viable alternative for performing lung SBRT in the absence of a LINAC equipped with HD-MLC. However, extra consideration should be taken in determining whether to use Halcyon when the planning target volume setting is enormous, as in the case of significant tumor motions.

A novel fully covered metal stent for unresectable malignant distal biliary obstruction: results of a multicenter prospective study

  • Arata Sakai;Atsuhiro Masuda;Takaaki Eguchi;Keisuke Furumatsu;Takao Iemoto;Shiei Yoshida;Yoshihiro Okabe;Kodai Yamanaka;Ikuya Miki;Saori Kakuyama;Yosuke Yagi;Daisuke Shirasaka;Shinya Kohashi;Takashi Kobayashi;Hideyuki Shiomi;Yuzo Kodama
    • Clinical Endoscopy
    • /
    • v.57 no.3
    • /
    • pp.375-383
    • /
    • 2024
  • Background/Aims: Endoscopic self-expandable metal stent (SEMS) placement is currently the standard technique for treating unresectable malignant distal biliary obstructions (MDBO). Therefore, covered SEMS with longer stent patency and fewer migrations are required. This study aimed to assess the clinical performance of a novel, fully covered SEMS for unresectable MDBO. Methods: This was a multicenter single-arm prospective study. The primary outcome was a non-obstruction rate at 6 months. The secondary outcomes were overall survival (OS), recurrent biliary obstruction (RBO), time to RBO (TRBO), technical and clinical success, and adverse events. Results: A total of 73 patients were enrolled in this study. The non-obstruction rate at 6 months was 61%. The median OS and TRBO were 233 and 216 days, respectively. The technical and clinical success rates were 100% and 97%, respectively. Furthermore, the rate of occurrence of RBO and adverse events was 49% and 21%, respectively. The length of bile duct stenosis (<2.2 cm) was the only significant risk factor for stent migration. Conclusions: The non-obstruction rate of a novel fully covered SEMS for MDBO is comparable to that reported earlier but shorter than expected. Short bile duct stenosis is a significant risk factor for stent migration.

Endoscopic submucosal dissection in colorectal neoplasia performed with a waterjet system-assisted knife: higher en-bloc resection rate than conventional technique

  • Paolo Cecinato;Matteo Lucarini;Francesco Azzolini;Mariachiara Campanale;Fabio Bassi;Annalisa Cippitelli;Romano Sassatelli
    • Clinical Endoscopy
    • /
    • v.55 no.6
    • /
    • pp.775-783
    • /
    • 2022
  • Background/Aims: Colorectal endoscopic submucosal dissection (ESD) is burdened by its associated high risk of adverse events and long procedure time. Recently, a waterjet-assisted knife was introduced to simplify and speed up the procedure. The aim of this study was to evaluate the efficacy and safety of waterjet-assisted ESD (WESD) compared to that of the conventional ESD (CESD) technique. Methods: The charts of 254 consecutive patients who underwent colorectal ESD between January 2014 and February 2021 for colorectal neoplasms were analyzed. The primary outcome was the en-bloc resection rate. Secondary outcomes were complete and curative resection rates, the need to switch to a hybrid ESD, procedure speed, the adverse event rates, and the recurrence rates. Results: Approximately 174 neoplasias were considered, of which, 123 were removed by WESD and 51 by CESD. The en-bloc resection rate was higher in the WESD group (94.3% vs. 84.3%). Complete resection rates and curative resection rates were similar. The need to switch to a hybrid ESD was greater during CESD (39.2% vs. 13.8%). Procedure speed and adverse event rates were similar. During follow-up, one recurrence occurred after a WESD. Conclusions: WESD allows a high rate of en-bloc resections and less frequently requires a rescue switch to the hybrid ESD compared to CESD.

Evaluation of Dose Change by Using the Deformable Image Registration (DIR) on the Intensity Modulated Radiation Therapy (IMRT) with Glottis Cancer (성문암 세기조절 방사선치료에서 변형영상정합을 이용한 선량변화 평가)

  • Kim, Woo Chul;Min, Chul Kee;Lee, Suk;Choi, Sang Hyoun;Cho, Kwang Hwan;Jung, Jae Hong;Kim, Eun Seog;Yeo, Seung-Gu;Kwon, Soo-Il;Lee, Kil-Dong
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.167-175
    • /
    • 2014
  • The purpose of this study is to evaluate the variation of the dose which is delivered to the patients with glottis cancer under IMRT (intensity modulated radiation therapy) by using the 3D registration with CBCT (cone beam CT) images and the DIR (deformable image registration) techniques. The CBCT images which were obtained at a one-week interval were reconstructed by using B-spline algorithm in DIR system, and doses were recalculated based on the newly obtained CBCT images. The dose distributions to the tumor and the critical organs were compared with reference. For the change of volume depending on weight at 3 to 5 weeks, there was increased of 1.38~2.04 kg on average. For the body surface depending on weight, there was decreased of 2.1 mm. The dose with transmitted to the carotid since three weeks was increased compared be more than 8.76% planned, and the thyroid gland was decreased to 26.4%. For the physical evaluation factors of the tumor, PITV, TCI, rDHI, mDHI, and CN were decreased to 4.32%, 5.78%, 44.54%, 12.32%, and 7.11%, respectively. Moreover, $D_{max}$, $D_{mean}$, $V_{67.50}$, and $D_{95}$ for PTV were increased or decreased to 2.99%, 1.52%, 5.78%, and 11.94%, respectively. Although there was no change of volume depending on weight, the change of body types occurred, and IMRT with the narrow composure margin sensitively responded to such a changing. For the glottis IMRT, the patient's weight changes should be observed and recorded to evaluate the actual dose distribution by using the DIR techniques, and more the adaptive treatment planning during the treatment course is needed to deliver the accurate dose to the patients.

Lung Biopsy after Localization of Pulmonary Nodules with Hook Wire (Hook Wire를 이용한 폐결절의 위치선정 및 생검)

  • Kim, Jin-Sik;Hwang, Jae-Joon;Lee, Song-Am;Lee, Woo-Surng;Kim, Yo-Han;Kim, Jun-Seok;Chee, Hyun-Keun;Yi, Jeong-Geun
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.681-686
    • /
    • 2010
  • Background: A chest computed-tomography has become more prevalent so that it is more common to detect small sized pulmonary nodules that have not been found in previous simple chest x-ray. If those detected nodules are undersized or located in pulmonary parenchyma, it is difficult to accomplish a biopsy since it is vulnerable to explore them either grossly or digitally. Thus, in our hospital, a thoracoscopic pulmonary wedge resection was performed after locating a lesion by means of hook wire with CT-guided. Material and Method: 31 patients (17 males and 14 female patients) from December in 2006 to June in 2010 became our subjects; their 34 pulmonary nodules were subjected to the thoracoscopic pulmonary wedge resection after locating a lesion by means of hook wire with CT-guided. Also we analyzed a possibility of hook wire dislocation, a frequency of conversion to open thoracotomy, time consumed to operation after location of a lesion, operation time, post operation complication, and histological diagnosis of the lesion. Result: 12 of 34 cases were ground glass lesion, whereas 22 cases of them were solitary pulmonary lesion. The median value of the lesion was 8mm in size (range: 3 to 23 mm), while the median value was 12.5 mm in depth (range: 1 to 34 mm). The median value of time consumed from location of the lesion to anesthetic induction was 86.5 minutes (41~473 minutes); furthermore the mean value of operation time was 103 minutes (25~345 minutes). Intrathoracic wire dislocation was found in one case, but a target lesion was successfully excised. Open thoracotomy was performed in four cases due to pleural adhesion. However, there was no case of conversion to open thoracotomy due to failure to detect a target lesion. In histological diagnosis, metastatic cancer were found in 15 cases, which were the most common, primary lung cancer were in 9 cases, non-specific inflammation were in 3 cases, tuberculosis inflammation were in 2 cases, lymph nodes were in 2 cases, active tuberculosis were in 1 case, atypical adenomatous hyperplasia was in 1 case and normal lung parenchymal finding was in 1 case, respectively. Conclusion: In our hospital, in order to accomplish a precise histological diagnosis of ground-glass lesion and pulmonary nodules in lung parenchyma, location of pulmonary nodules were exactly located with hook wire under chest computed-tomography, which was followed by lung biopsy. We concluded that this was an accurate, minimally invasive and valuable method to minimize the complications and increase of cost of medical service provided.

THE CHANGE OF SALIVARY FLOW RATE, AND CONCENTRATION OF TOTAL PROTEIN AND IGA AFTER RADIATION THERAPY OF ORAL CANCER (구강암 환자에서 방사선 조사에 따른 타액량, 총 단백 및 IgA 농도의 변화)

  • Lee, Jong-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.3
    • /
    • pp.249-256
    • /
    • 1999
  • This study was performed to investigate the changes in flow and composition of saliva in oral cancer patients after radiation therapy. Stimulated whole saliva was collected from 7 patients who were scheduled for over 6,000cGy irradiation (180 - 225cGy fraction $Co^{60}$ therapy, 5 times a week). The flow rate of saliva, and concentration of total protein and IgA were measured before irradiation and 1, 2, 3, 4, 5 days and 1, 2, 3, 4, 6 weeks and 3, 6, 12 months after. The followings are results we obtained: 1. The salivary flow rate before irradiation was $0.8671{\pm}0.4057ml/min$. Significant decrease started 3 days after irradiation and reached a minimum at 4 weeks ($0.2621{\pm}0.2858ml/min$). Afterwards, flow rate started to increase and was on the way to recover at 1 year. 2. The concentration of total protein and IgA before irradiation were $137.2000{\pm}16.9912mg%$ and $3.4200{\pm}1.4114mg%$, respectively. After irradiation, these figures increased significantly and reached a maximum of $366.4000{\pm}174.0583mg%$ and $43.4800{\pm}29.1207mg/ml$, respectively at 6 weeks. Recovery towards normal values started following the end of irradiation and figures at 12 months had lowered to $165.400{\pm}21.1495mg%$ and $4.6200{\pm}2.1580mg/ml$ each. 3. The ratio of IgA to the amount of total protein was 2.5% before irradiation. This began to increase from 1 week following irradiation as the total dose of radiation received was increased (11.9% at 6 weeks). After 1 year from the start of radiation therapy, the ratio was reduced to such level that was before irradiation.

  • PDF

The Efficacy of Aspirin in Preventing the Recurrence of Colorectal Adenoma: a Renewed Meta-Analysis of Randomized Trials

  • Zhao, Tai-Yun;Tu, Jing;Wang, Yin;Cheng, Da-Wei;Gao, Xian-Kui;Luo, Hao;Yan, Bi-Chun;Xu, Xiao-Li;Zhang, Hong-Ling;Lu, Xing-Jun;Wang, Yao-Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2711-2717
    • /
    • 2016
  • Background: Through search the possible randomized control trials, we make a renewed meta-analysis in order to assess the impact of aspirin in preventing the recurrence of colorectal adenoma. Materials and Methods: The Medicine/PubMed, Embase, Cochrane Central Register of Controlled Trials (CENTRAL), Chinese biomedical literature service system (SinoMed) databases were searched for the related randomized controlled trials until to the April 2016. Three different authors respectively evaluated the quality of studies and extracted data, and we used the STATA software to analyze, investigate heterogeneity between the data, using the fixed-effects model to calculate and merge data. Results: 7 papers were included the renewed meta-analysis, among these studies, two pairs were identified as representing the same study population, with the only difference being the duration of follow-up. Thus there were only five papers included our meta-analysis, and one Chinese paper were also included the work. Results were categorized by the length of follow-up, different kinds of people, varied dose of oral aspirin. The relative of adenoma in patients taking aspirin vs placebo were 0.73 (95% CI 0.55-0.98, P=0.039) with 1 year follow up; 0.84 (95% CI 0.72-0.98, P=0.484) with greater than 1 year follow up; for the advanced adenoma, the RR 0.68 (95% CI 0.49-0.94, P=0.582),for one year; RR=0.75 (95% CI 0.52-1.07, P=0.552) for greater one year. Furthermore the white population could divided into two subgroups according to the different length of follow-up time. When the length of follow-up time less than 3-year, The RR of two subgroups respective were RR=0.86 (95% CI 0.76-0.98, P=0.332), $I^2=0%$, RR=0.68 (95% CI 0.47-0.98, P=0.552), $I^2=64.6%$, But with the extension of follow-up time greater than 2-year, with the white, oral aspirin without considering dose had no efficacy on preventing the recurrence of any adenoma, the RR was 0.86 (95% CI 0.71-1.05, P=0.302), $I^2=16.4%$. Conclusions: This meta-analysis indicated that oral aspirin is associated with a remarkable decrease in the recurrence of any adenoma and advanced adenomas in patients follow-up for 1 year without concerning the dose of aspirin, but with the extension of follow-up time for greater than 1 year, oral aspirin can be effective on preventing the recurrence of any adenoma, but for the advanced adenoma, the result indicated that oral aspirin had no efficacy, According to the inclusion of ethnic groups, we also divided relevant papers into two subgroups as the yellow and white group. Then the follow-up time was less than 3 years, oral aspirin without considering the dose, had an significant efficacy on preventing the recurrence of any adenoma. But with the follow-up greater than 2 years, oral aspirin had no effect in the white.