• Title/Summary/Keyword: Cancer imaging

Search Result 1,166, Processing Time 0.023 seconds

Associations Between Mammography and Ultrasound Imaging Features and Molecular Characteristics of Triple-negative Breast Cancer

  • Li, Bo;Zhao, Xin;Dai, Shao-Chun;Cheng, Wen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3555-3559
    • /
    • 2014
  • Background: The triple-negative breast cancer (TNBC) is an aggressive cancer characterized by the absence of estrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor 2 (HER2). Preoperative mammography and ultrasound features of TNBC may potentially suggest characteristics of the disease and assist in treatment decisions. Materials and Methods: The study covered 153 patients with TNBC from May 2011 to May 2012 who were confirmed by postoperative pathology results in our hospital. We compared the radiological findings among the patients and sought to determine the significant iconographic features. The biomarkers p53 and Ki-67 are regarded as significant factors in TNBC. They were therefore used to divide the TNBC into four groups for assessment of relationships with TNBC imaging features. Results: On mammography, most TNBCs exhibit obscure (44.3%) masses. On ultrasound, the majority of masses (95.4%) were predominantly indistinct (50.7%), irregular (76.0%) or featuring posterior echo enhancement/shadowing. Color Doppler flow imaging (CDFI) emphasized hypervascular (32.9%) masses. Differences in CDFI by ultrasound among the four groups were statistically significant (p=0.009). There were obvious differences in the percentages of spiculated margin (p=0.049) and intensive posterior echo (p=0.006) with spotty flow imaging by ultrasound between the Ki-67 (+) p53 (+) and other groups. Conclusions: A combination of mammography and ultrasound revealed the imaging characteristics of TNBC included an obscure mass with less attenuated posterior echoes and some vascularity. A worse prognosis was associated with spiculated margin and intensive posterior echoes with spotty flow imaging.

Comparison of real-time ultrasound imaging for manual lymphatic drainage on breast cancer-related lymphedema in individuals with breast cancer: a preliminary study

  • Seo, Dongkwon;Lee, Seungwon;Choi, Wonjae
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.1
    • /
    • pp.43-48
    • /
    • 2020
  • Objective: Breast cancer-related lymphedema (BCRL) is a major sequela after surgery or radiotherarpy for breast cancer. Manual lymphatic drainage (MLD) is designed to reduce lymph swelling by facilitating lymphatic drainage. This study attempted to determine the histologic changes in the skin and subcutaneous layer, and the immediate effect of MLD in decreasing lymphedema using ultrasound imaging, which is the method used most commonly to eliminate BCRL. Design: A single-group experimental study. Methods: Five subjects who were diagnosed with hemiparetic upper extremity lymphedema more than six months after breast cancer surgery participated in the study. MLD was performed for 60 minutes in the order of the thorax, breast, axilla, and upper arm of the affected side. In order to determine the effect of MLD, ultrasound imaging and limb volume were assessed. Two measurement tools were used for asessing lymphedema thickness among the pretest, posttest, and 30-minute follow-up period. Results: Significant diferences in ultrasound imaging and upper limb volume were found between the affected side and non-affected side (p<0.05). On the affected side, although ultrasound imaging showed a significant decrease after MLD (p<0.05), there were no significant difference in upper limb volume when compared to the baseline. Conclusions: In this study, a significant decrease in lymphedema by MLD was demonstrated by ultrasound imaging, which is considered to be more useful in assessing histological changes than limb volume measurements. Further research on the protocol for eliminating lymphedema will be needed.

Isolated Splenic Metastasis of Sigmoid Colon Cancer Detected by $^{18}F-FDG$ PET/CT ($^{18}F-FDG$ PET/CT 에서 발견된 S상 결장암의 단일 비장 전이)

  • An, Young-Sil;Yoon, Joon-Kee;Hong, Seon-Pyo;Choi, Bong-Hoi;Joh, Chul-Woo;Yoon, Seok-Nam
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.263-264
    • /
    • 2007
  • Splenic metastasis from colon carcinoma are rare and usually occur in the presence of disseminated visceral metastasis. The liver is the most common site of metastatic spread from colon cancer. Several hypotheses have attempted to explain the low incidence of splenic metastasis. It should be difficult for colorectal cancer cells to reach the spleen through the portal venous system, in which the blood flow is usually from the spleen to the liver. Reticuloendothelial system or rhythmic contraction of the spleen may squeeze out the tumor in the spleen. The absence of afferent lymphatic to the spleen, phagocytic activity and humoral anticancer substances are considered to be other reason for low incidence of splenic metastasis. We report the case of $^{18}F-FDG$ PET/CT finding in a 70-year-old woman who develop isolated splenic metastasis of sigmoid colon cancer.

Advances in Optimal Detection of Cancer by Image Processing; Experience with Lung and Breast Cancers

  • Mohammadzadeh, Zeinab;Safdari, Reza;Ghazisaeidi, Marjan;Davoodi, Somayeh;Azadmanjir, Zahra
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5613-5618
    • /
    • 2015
  • Clinicians should looking for techniques that helps to early diagnosis of cancer, because early cancer detection is critical to increase survival and cost effectiveness of treatment, and as a result decrease mortality rate. Medical images are the most important tools to provide assistance. However, medical images have some limitations for optimal detection of some neoplasias, originating either from the imaging techniques themselves, or from human visual or intellectual capacity. Image processing techniques are allowing earlier detection of abnormalities and treatment monitoring. Because the time is a very important factor in cancer treatment, especially in cancers such as the lung and breast, imaging techniques are used to accelerate diagnosis more than with other cancers. In this paper, we outline experience in use of image processing techniques for lung and breast cancer diagnosis. Looking at the experience gained will help specialists to choose the appropriate technique for optimization of diagnosis through medical imaging.

Significance and Application of Digital Breast Tomosynthesis for the BI-RADS Classification of Breast Cancer

  • Cai, Si-Qing;Yan, Jian-Xiang;Chen, Qing-Shi;Huang, Mei-Ling;Cai, Dong-Lu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.4109-4114
    • /
    • 2015
  • Background: Full-field digital mammography (FFDM) with dense breasts has a high rate of missed diagnosis, and digital breast tomosynthesis (DBT) could reduce organization overlapping and provide more reliable images for BI-RADS classification. This study aims to explore application of COMBO (FFDM+DBT) for effect and significance of BI-RADS classification of breast cancer. Materials and Methods: In this study, we selected 832 patients who had been treated from May 2013 to November 2013. Classify FFDM and COMBO examination according to BI-RADS separately and compare the differences for glands in the image of the same patient in judgment, mass characteristics display and indirect signs. Employ Paired Wilcoxon rank sum test was used in 79 breast cancer patients to find differences between two examine methods. Results: The results indicated that COMBO pattern is able to observe more details in distribution of glands when estimating content. Paired Wilcoxon rank sum test showed that overall classification level of COMBO is higher significantly compared to FFDM to BI-RADS diagnosis and classification of breast (P<0.05). The area under FFDM ROC curve is 0.805, while that is 0.941 in COMBO pattern. COMBO shows relation of mass with the surrounding tissues, the calcification in the mass, and multiple foci clearly in breast cancer tissues. The optimal sensitivity of cut-off value in COMBO pattern is 82.9%, which is higher than that in FFDM (60%). They share the same specificity which is both 93.2%. Conclusions: Digital Breast Tomosynthesis (DBT) could be used for the BI-RADS classification in breast cancer in clinical.

Clinical Application of $^{18}F-FDG$ PET in Testicular Cancer (고환암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Yoon, Joon-Kee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.121-125
    • /
    • 2008
  • $^{18}F-FDG$ PET has a higher diagnostic accuracy than a in initial staging of testicular cancer. In seminoma, it can discriminate residual tumor from necrosis/fibrosis or mature teratoma. $^{18}F-FDG$ PET is also useful for the response evaluation of chemotherapy. However, there's no clinical evidence for the use of $^{18}F-FDG$ PET in the diagnosis and differential diagnosis of testicular cancer.

Terahertz Pulse Imaging of Micro-metastatic Lymph Nodes in Early-stage Cervical Cancer Patients

  • Jung, Eun-A;Lim, Mee-Hyun;Moon, Ki-Won;Do, Young-Woong;Lee, Soon-Sung;Han, Hae-Wook;Choi, Hyuck-Jae;Cho, Kyoung-Sik;Kim, Kyu-Rae
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.155-160
    • /
    • 2011
  • Lymph node metastasis is an important prognostic factor in cervical cancer patients. We report THz imaging for detecting micro-metastatic foci in the lymph nodes of early-stage uterine cervical cancer patients. Five paraffin-embedded metastatic lymph nodes from two cervical cancer patients were imaged using a THz time-domain spectroscopy system in the reflection mode. The size and shape of the tumor regions were compared with those from histopathologic examinations. The metastatic portions of lymph nodes as small as 3 mm were well delineated by THz imaging. The reflected peak amplitudes were lower in metastatic portions than in the normal portions of lymph nodes, and the difference in their peak-to-peak amplitudes was ~5%.

Polymeric nanoparticles as dual-imaging probes for cancer management

  • Menon, Jyothi U.;Jadeja, Parth;Tambe, Pranjali;Thakore, Dheeraj;Zhang, Shanrong;Takahashi, Masaya;Xie, Zhiwei;Yang, Jian;Nguyen, Kytai T.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.3 no.3
    • /
    • pp.129-140
    • /
    • 2016
  • This article reports the development of biodegradable photoluminescent polymer (BPLP)-based nanoparticles (NPs) incorporating either magnetic nanoparticles (BPLP-MNPs) or gadopentate dimeglumine (BPLP-Gd NPs), for cancer diagnosis and treatment. The aim of the study is to compare these nanoparticles in terms of their surface properties, fluorescence intensities, MR imaging capabilities, and in vitro characteristics to choose the most promising dual-imaging nanoprobe. Results indicate that BPLP-MNPs and BPLP-Gd NPs had a size of $195{\pm}43nm$ and $161{\pm}55nm$, respectively and showed good stability in DI water and 10% serum for 5 days. BPLP-Gd NPs showed similar fluorescence as the original BPLP materials under UV light, whereas BPLP-MNPs showed comparatively less fluorescence. VSM and MRI confirmed that the NPs retained their magnetic properties following encapsulation within BPLP. Further, in vitro studies using HPV-7 immortalized prostate epithelial cells and human dermal fibroblasts (HDFs) showed > 70% cell viability up to $100{\mu}g/ml$ NP concentration. Dose-dependent uptake of both types of NPs by PC3 and LNCaP prostate cancer cells was also observed. Thus, our results indicate that BPLP-Gd NPs would be more appropriate for use as a dual-imaging probe as the contrast agent does not mask the fluorescence of the polymer. Future studies would involve in vivo imaging following administration of BPLP-Gd NPs for biomedical applications including cancer detection.

The Offer of Advanced Imaging Techniques Leads to Higher Acceptance Rates for Screening Colonoscopy - a Prospective Study

  • Albrecht, Heinz;Gallitz, Julia;Hable, Robert;Vieth, Michael;Tontini, Gian Eugenio;Neurath, Markus Friedrich;Riemann, Jurgen Ferdinand;Neumann, Helmut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.8
    • /
    • pp.3871-3875
    • /
    • 2016
  • Background: Colonoscopy plays a fundamental role in early diagnosis and management of colorectal cancer and requires public and professional acceptance to ensure the ongoing success of screening programs. The aim of the study was to prospectively assess whether patient acceptance rates to undergo screening colonoscopy could be improved by the offer of advanced imaging techniques. Materials and Methods: Overall, 372 randomly selected patients were prospectively included. A standardized questionnaire was developed that inquired of the patients their knowledge regarding advanced imaging techniques. Second, several media campaigns and information events were organized reporting about advanced imaging techniques, followed by repeated evaluation. After one year the evaluation ended. Results: At baseline, 64% of the patients declared that they had no knowledge about new endoscopic methods. After twelve months the overall grade of information increased significantly from 14% at baseline to 34%. The percentage of patients who decided to undergo colonoscopy because of the offer of new imaging methods also increased significantly from 12% at baseline to 42% after 12 months. Conclusions: Patients were highly interested in the offer of advanced imaging techniques. Knowledge about these techniques could relatively easy be provided using local media campaigns. The offer of advanced imaging techniques leads to higher acceptance rates for screening colonoscopies.