• Title/Summary/Keyword: Cancer imaging

Search Result 1,166, Processing Time 0.03 seconds

Clinical Manifestations and Imaging Characteristics of Gliomatosis Cerebri with Pathological Confirmation

  • Zhang, Chun-Pu;Li, Hua-Qing;Zhang, Wei-Tao;Liu, Ming-Hui;Pan, Wen-Jing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4487-4491
    • /
    • 2014
  • Objective: To explore the clinical manifestations and imaging characteristics of gliomatosis cerebri to raise the awareness and improve its diagnostic accuracy for patients. Materials and Methods: Clinical data, imaging characteristics and pathological examination of 12 patients with GC from Jan., 2008 to Jan., 2012 were analyzed retrospectively. Results: Patients with GC were clinically manifested with headache, vomiting, repeated seizures, fatigue and unstable walking, most of whom had more than 2 lesions involving in parietal lobe, followed by temporal lobe, frontal lobe, periventricular white matter and corpus callosum. Magnetic resonance imaging (MRI) showed diffuse distribution, T1-weighted images (T1WI) with equal and low signals and T2-weighted images (T2WI) with bilateral symmetrical high diffuse signals. There was no reinforcement by enhancement scanning and signals were different in diffusion-weighted images (DWI). The higher the tumor staging, the stronger the signals. Pathological examination showed neuroastrocytoma in which tumor tissues were manifested by infiltrative growth in blood vessels and around neurons. Conclusions: In clinical diagnosis of GC, much attention should be paid to the diffuse distribution of imaging characteristics, incomplete matching between clinical and imaging characteristics and confirmation by combining with histopathological examination.

Development of Effective Analytical Signal Models for Functional Microwave Imaging

  • Baang, Sung-Keun;Kim, Jong-Dae;Lee, Yong-Up;Park, Chan-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.471-476
    • /
    • 2007
  • Various active microwave imaging techniques have been developed for cancer detection for past several decades. Both the microwave tomography and the UWB radar techniques, constituting functional microwave imaging systems, use the electrical property contrast between normal tissues and malignancies to detect the latter in an early development stage. Even though promising simulation results have been reported, the understanding of the functional microwave imaging diagnostics has been relied heavily on the complicated numerical results. We present a computationally efficient and physically instructive analytical electromagnetic wave channel models developed for functional microwave imaging system in order to detect especially the breast tumors as early as possible. The channel model covers the propagation factors that have been examined in the previous 2-D models, such as the radial spreading, path loss, partial reflection and transmission of the backscattered electromagnetic waves from the tumor cell. The effects of the system noise and the noise from the inhomogeneity of the tissue to the reconstruction algorithm are modeled as well. The characteristics of the reconstructed images of the tumor using the proposed model are compared with those from the confocal microwave imaging.

Robotized Percutaneous Biopsy (로봇을 이용한 경피 생체 검사)

  • Son, Jaebum;Kim, Kwang Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.105-113
    • /
    • 2012
  • Biopsy is a type of histopathological examinations, in which a physician samples cells or tissues from a patient's suspicious lesion. Such a lesion frequently resides deep inside human body, and then a percutaneous biopsy is therefore performed using a thick needle with the assistance of medical imaging such as computed tomography(CT) and magnetic resonance imaging(MRI). Recently modern robotic technology is being introduced to percutaneous biopsy in order to reduce any possible human error and hazard on physicians caused by medical imaging. After medical imaging locates the exact location of lesion, an optimization algorithm plans the path for a biopsy needle. Subsequently, a robot system moves the biopsy needle to the lesion in accurate and safe way with the control of a practitioner or automatically. In this article, we try to look into the state-of-art of percutaneous biopsy using such robotic technology. We classified percutaneous biopsy robots by mechanical characteristics and by imaging technology. Then, advantage and disadvantage of each class type are described as well as the basic description, and a few representative designs for each type are introduced. Current research issues of robotized percutaneous biopsy are subjectively selected for the readers' convenience. We emphasize the basic technology of actuator and sensors compatible with imaging technology to conclude this review.

The Usefulness of Three-Dimensional Imaging with Spiral CT for Evaluation of the Upper Airway Lesions (상부기도병변의 평가에 있어 나선식컴퓨터단층촬영술을 이용한 3차원적 영상의 유용성)

  • 김진환;김현웅;소상훈;노영수;임현준;윤대영
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.1
    • /
    • pp.43-51
    • /
    • 1998
  • Background: Three-dementional imaging with spiral CT(3D spiral CT) is a well established imaging modality which has been investigated in various clinical settings. However the 3D spiral CT in upper airway disease is rarely reported and its results are still obscure. Objectives: To access the usefulness of 3D spiral CT imaging in patients with upper airway diseases. Materials and Methods We performed 3D spiral CT in fourteen patients In whom upper airway diseases were clinically suspected. Nine of these patients had upper airway stenosis, two had laryngeal cartilage fracture, and three had laryngo-hypopharyngeal cancer. For evaluation of location and extent of the lesions, we compared the findings of 3D imaging with those of air tracheogram, conventional 2D CT images, endoscopic and operative findings. Results: In case of stenosis, 3D spiral CT provide significant useful information, particularly the site and length of the stenotic segment. But, it was difficult to define the fracture of the laryngeal framework and to detect the cartilagenous invasion by head and neck cancer using the 3D imaging. Conclusion : The 3D spiral CT was an useful adjunctive method to assess some kind of upper airway disease but not in others. So, we should compare the findings of 3D images with those of other diagnostic tools for accurate diagnosis of the upper airway disease.

  • PDF

What Is the Problem in Clinical Application of Sentinel Node Concept to Gastric Cancer Surgery?

  • Miyashiro, Isao
    • Journal of Gastric Cancer
    • /
    • v.12 no.1
    • /
    • pp.7-12
    • /
    • 2012
  • More than ten years have passed since the sentinel node (SN) concept for gastric cancer surgery was first discussed. Less invasive modified surgical approaches based on the SN concept have already been put into practice for malignant melanoma and breast cancer, however the SN concept is not yet placed in a standard position in gastric cancer surgery even after two multi-institutional prospective clinical trials, the Japan Clinical Oncology Group trial (JCOG0302) and the Japanese Society for Sentinel Node Navigation Surgery (SNNS) trial. What is the problem in the clinical application of the SN concept to gastric cancer surgery? There is no doubt that we need reliable indicator(s) to determine with certainty the absence of metastasis in the lymph nodes in order to avoid unnecessary lymphadenectomy. There are several matters of debate in performing the actual procedure, such as the type of tracer, the site of injection, how to detect and harvest, how to detect metastases of SNs, and learning period. These issues have to be addressed further to establish the most suitable procedure. Novel technologies such as indocyanine green (ICG) fluorescence imaging and one-step nucleic acid amplification (OSNA) may overcome the current difficulties. Once we know what the problems are and how to tackle them, we can pursue the goal.

Clinical Application of $^{18}F-FDG$ PET in Ovarian Cancer (난소암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Oh, So-Won;Kim, Seok-Ki
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.91-100
    • /
    • 2008
  • Ovarian cancer is often fatal since it is difficult to diagnose early and recurrence is quite frequent despite successful implementation of cytoreductive surgery and chemotherapy, thus exact diagnosis and early detection of recurrence are crucial to patient management. For pre-treatment staging, FDG PET could be helpful in a limited patient group possessing high risks of ovarian cancer. Besides, FDG PET could be recommended to patients with a high suspicion of recurrence i.e. rise of CA-125, especially in cases of conventional diagnostic imaging modalities presenting no evidence of disease because FDG PET provides critical information for treatment planning such as recurrence site or pattern. In order to expand the use of FDG PET to general population at staging or routine surveillance of ovarian cancer, more investigation is needed. The usefulness of FDG PET in evaluating treatment response and prognosis of ovarian cancer has not yet been determined, but it has been reported that FDG PET could evaluate treatment response early and show a close relationship with overall survival. PET/CT has been actively adopted in management of ovarian cancer. Not only in detecting tumor recurrence and evaluating treatment response but also in pre-treatment staging, FDG PET/CT is expected to playa role due to available anatomical information.

Development of Image-based System for Multiple Fluorescence Imaging Study (다중형광영상 연구를 위한 영상기반 시스템 개발)

  • Yoon, WoongBae;Kim, Hong Rae;Lee, Hyun Min;Kim, Young Jae;Kim, Kwang Gi;Yoo, Heon;Lee, Seung Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.12
    • /
    • pp.1445-1452
    • /
    • 2015
  • In these days, fluorescent materials such as ICG or 5-ALA is used for the brain surgery. The patients who underwent brain tumor surgery has been increased during last 30 years and the survivorship rate increased 22∼33% in 5 years. Recently, the Fluorescence induction surgery is developed for more safety and improved the resection rate for the glioma in the neurosurgery field. In this study, we proposed fluorescence area detection method for ICG and 5-ALA fluorescence induced surgery using acquired images from image processing. Accuracy was 99.21% from ICG images, and 99.51% from 5-ALA images. Matthews correlation coefficient was 88.67% from ICG images, and 90.49% from 5-ALA images.

Diagnostic Value of Contrast-Enhanced Digital Mammography versus Contrast-Enhanced Magnetic Resonance Imaging for the Preoperative Evaluation of Breast Cancer

  • Kim, Eun Young;Youn, Inyoung;Lee, Kwan Ho;Yun, Ji-Sup;Park, Yong Lai;Park, Chan Heun;Moon, Juhee;Choi, Seon Hyeong;Choi, Yoon Jung;Ham, Soo-Youn;Kook, Shin Ho
    • Journal of Breast Cancer
    • /
    • v.21 no.4
    • /
    • pp.453-462
    • /
    • 2018
  • Purpose: This study aimed to compare the diagnostic performance of contrast-enhanced digital mammography (CEDM) and contrast-enhanced magnetic resonance imaging (CEMRI) in preoperative evaluations, and to evaluate the effect of each modality on the surgical management of women with breast cancer. Methods: This single-center, prospective study was approved by the Institutional Review Board, and informed consent was obtained from all patients. From November 2016 to October 2017, 84 patients who were diagnosed with invasive carcinoma (69/84) and ductal carcinoma in situ (15/84), and underwent both CEDM and CEMRI, were enrolled. Imaging findings and surgical management were correlated with pathological results and compared. The diagnostic performance of both modalities in the detection of index and secondary cancers (multifocality and multicentricity), and occult cancer in the contralateral breast, was compared. The authors also evaluated whether CEDM or CEMRI resulted in changes in the surgical management of the affected breast due to imaging-detected findings. Results: Eighty-four women were included in the analysis. Compared with CEMRI, CEDM demonstrated a similar sensitivity (92.9% [78/84] vs. 95.2% [80/84]) in detecting index cancer (p=0.563). For the detection of secondary cancers in the ipsilateral breast and occult cancer in the contralateral breast, no significant differences were found between CEDM and CEMRI (p=0.999 and p=0.999, respectively). Regarding changes in surgical management, CEDM resulted in similar changes compared with CEMRI (30.9% [26/84] vs. 29.7% [25/84], p=0.610). Regarding changes in surgical management due to false-positive findings, no significant differences were found between CEDM and CEMRI (34.6% [9/26] vs. 44.0% [11/25], p=0.782). Conclusion: CEDM demonstrated a diagnostic performance comparable with CEMRI in depicting index cancers, secondary cancers, and occult cancer in the contralateral breast. CEDM demonstrated similar changes in surgical management compared with CEMRI.

Initial experience of magnetic resonance imaging/ultrasonography fusion transperineal biopsy: Biopsy techniques and results for 75 patients

  • Tae, Jong Hyun;Shim, Ji Sung;Jin, Hyun Jung;Yoon, Sung Goo;No, Tae Il;Kim, Jae Yoon;Kang, Seok Ho;Cheon, Jun;Kang, Sung Gu
    • Investigative and Clinical Urology
    • /
    • v.59 no.6
    • /
    • pp.363-370
    • /
    • 2018
  • Purpose: The aim of this study is to describe the technique and to report early results of transperineal magnetic resonance imaging and ultrasonography (MRI-US) fusion biopsy. Materials and Methods: A total of 75 patients underwent MRI-US fusion transperineal biopsy. Targeted biopsy via MRI-US fusion imaging was carried out for cancer-suspicious lesions with additional systematic biopsy. Detection rates for overall and clinically significant prostate cancer (csPCa) were evaluated and compared between systematic and targeted biopsy. In addition, further investigation into the detection rate according to prostate imaging reporting and data system (PI-RADS) score was done. Results of repeat biopsies were also evaluated. Results: Overall cancer detection rate was 61.3% (46 patients) and the detection rate for csPCa was 42.7% (32 patients). Overall detection rates for systematic and targeted biopsy were 41.3% and 57.3% (p<0.05), respectively. Detection rates for csPCa were 26.7% and 41.3%, respectively (p<0.05). The cancer detection rates via MRI fusion target biopsy were 30.8% in PI-RADS 3, 62.1% in PI-RADS 4 and 89.4% in PI-RADS 5. Rates of csPCa missed by targeted biopsy and systematic biopsy were 0.0% and 25.0%, respectively. The cancer detection rate in repeat biopsies was 61.1% (11 among 18 patients) in which 55.5% of cancer suspected lesions were located in the anterior portion. Conclusions: Transperineal MRI-US fusion biopsy is useful for improving overall cancer detection rate and especially detection of csPCa. Transperineal MRI-US targeted biopsy show potential benefits to improve cancer detection rate in patients with high PIRADS score, tumor located at the anterior portion and in repeat biopsies.

Imaging Patterns of Bacillus Calmette-Guérin-Related Granulomatous Prostatitis Based on Multiparametric MRI

  • Seungsoo Lee;Young Taik Oh;Hye Min Kim;Dae Chul Jung;Hyesuk Hong
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.60-67
    • /
    • 2022
  • Objective: To categorize multiparametric MRI features of Bacillus Calmette-Guérin (BCG)-related granulomatous prostatitis (GP) and discover potential manifestations for its differential diagnosis from prostate cancer. Materials and Methods: The cases of BCG-related GP in 24 male (mean age ± standard deviation, 66.0 ± 9.4 years; range, 50-88 years) pathologically confirmed between January 2011 and April 2019 were retrospectively reviewed. All patients underwent intravesical BCG therapy followed by a MRI scan. Additional follow-up MRI scans, including diffusion-weighted imaging (DWI), were performed in 19 patients. The BCG-related GP cases were categorized into three: A, B, or C. The lesions with diffusion restriction and homogeneous enhancement were classified as type A. The lesions with diffusion restriction and a poorly enhancing component were classified as type B. A low signal intensity on high b-value DWI (b = 1000 s/mm2) was considered characteristic of type C. Two radiologists independently interpreted the MRI scans before making a consensus about the types. Results: The median lesion size was 22 mm with the interquartile range (IQR) of 18-26 mm as measured using the initial MRI scans. The lesion types were A, B, and C in 7, 15, and 2 patients, respectively. Cohen's kappa value for the inter-reader agreement for the interpretation of the lesion types was 0.837. On the last follow-up MRI scans of 19 patients, the size decreased (median, 5.8 mm; IQR, 3.4-8.5 mm), and the type changed from A or B to C in 11 patients. The lesions resolved in four patients. In five patients who underwent prostatectomy, caseous necrosis on histopathology matched with the non-enhancing components of type B lesions and the entire type C lesions. Conclusion: BCG-related GP demonstrated three imaging patterns on multiparametric MRI. Contrast-enhanced T1-weighted imaging and DWI may play a role in its differential diagnosis from prostate cancer.