• 제목/요약/키워드: Cancer diagnosis

검색결과 2,788건 처리시간 0.029초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가 (Evaluation of Standardized Uptake Value and Metabolic Tumor Volume between Reconstructed data and Re-sliced data in PET Study)

  • 도용호;이홍재;김진의
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.3-8
    • /
    • 2016
  • PET 검사에서 SUV는 암의 원발 부위, 전이여부 파악 및 병기결정, 재발여부 판단에 도움을 주는 지표이다. 특히 항암, 방사선치료 후 효과 판정을 위한 검사 시 이전 검사와의 SUV 비교 평가가 중요시 된다. 그러나 핵의학과 에서 자체적으로 데이터를 저장하는 외장하드, mini PACS 등의 저장 장치는 데이터 손실의 가능성을 가지고 있다. 이에 본 연구에서는 workstation의 reconstructed data (R-D)와 병원 PACS로 전송한 R-D, re-sliced data (S-D) 사이의 SUV를 비교 평가하여 자체 저장장치의 데이터 손실 시 PACS로 전송한 데이터의 사용가능 여부를 확인 하고자 한다. Biograph Truepoint 40, mCT 40, mCT 64, mMR (Siemens, Germany)장비에서 2015년 1월부터 2월까지 $^{18}F-FDG$ PET 검사를 시행한 20명($60.5{\pm}8.3$세)의 데이터를 분석하였다. Workstation의 R-D와 PACS의 R-D, S-D 데이터를 Syngo.via 프로그램으로 전송하여 liver, aorta, tumor 부위의 max SUV($SUV_{max}$), peak SUV ($SUV_{peak}$)와 tumor의 metabolic tumor volume (MTV)를 측정하였다. Workstation과 PACS의 R-D에서 liver, aorta, tumor의 평균 $SUV_{max}$$2.95{\pm}0.59$, $2.35{\pm}0.61$, $10.36{\pm}6.15$ 이었고 $SUV_{peak}$$2.70{\pm}0.51$, $2.07{\pm}0.43$, $7.67{\pm}3.73$으로 동일하였으며 통계적으로 유의한 차이가 없었다(p>0.05). PACS의 S-D는 R-D대비 평균 $SUV_{max}$는 5.18%, 7.22%, 12.11%, $SUV_{peak}$는 2.61%, 3.63%, 10.07% 감소하였으며 통계적으로 유의한 차이가 있었다(p<0.05). R-D와 S-D에서 결과 값의 상관계수는 $SUV_{max}$에서 0.99, 0.96, 0.99이었고 $SUV_{peak}$에서 0.99, 0.99, 0.99로 모두 양의 상관관계가 있었다. Bland-Altman 분석에서 2표준편차는 $SUV_{max}$에서 0.125, 0.290, 1.864이었고 $SUV_{peak}$에서 0.053, 0.103, 0.826이었다. Tumor의 MTV는 workstation과 PACS의 R-D에서 모두 $14.21{\pm}12.72cm^3$로 동일하였다(p>0.05). PACS의 S-D에서는 R-D 대비 0.12% 감소하였으며 통계적으로 유의한 차이가 없었다(p>0.05). R-D와 S-D에서 상관계수는 0.99이었고 Bland-Altman 분석에서 2표준편차는 2.243이였다. 본 논문에서 PACS에 저장된 R-D의 경우 workstation의 R-D와 비교하여 $SUV_{max}$, $SUV_{peak}$, MTV 모두에서 동일한 값을 보였으나 S-D의 경우 상관관계는 높지만 MTV를 제외한 $SUV_{max}$, $SUV_{peak}$는 통계적으로 유의한 차이가 있었다. R-D를 안정성 있는 병원 PACS에 저장한다면 자체 저장장치의 데이터 손실 시 이전 PET 데이터와의 비교에서 신뢰성 있는 SUV 분석이 가능할 것이라 생각된다.

  • PDF

면역방사계수법을 이용한 Thyroglobulin 측정시 항 Thyroglobulin 항체의 존재가 미치는 영향: Thyroglobulin 측정 키트에 따른 차이 (Effects of Anti-thyroglobulin Antibody on the Measurement of Thyroglobulin : Differences Between Immunoradiometric Assay Kits Available)

  • 안병철;서지형;배진호;정신영;유정수;정진향;박호용;김정국;하승우;손진호;이인규;이재태;김보완
    • 대한핵의학회지
    • /
    • 제39권4호
    • /
    • pp.252-256
    • /
    • 2005
  • 목적 : Thyroglobulin (Tg)은 갑상선질환의 병태생리에 중추적 역할을 하고 있으며, 분화갑상선암 환자에서 갑상선암 재발에 대한 추적관찰에 가장 중요한 표지자의 하나로 임상에서 널리 이용된다. 혈청 Tg는 방사면역검사법 및 면역방사계수검사법으로 주로 측정되는데, 항 Tg 항체가 Tg측정값의 부정확성에 주된 영향인자임이 알려져 있으며 본 연구진에서도 보고한 바 있다. 본 연구자들은 국내에서 가장 널리 이용되는 면역방사계수법 Tg 키트 2종류를 이용하여, Tg측정 시 항 Tg 항체 영향이 사용된 키트에 따라 어떤 차이가 있는지 알아보고자 하였다. 대상 및 방법 : 면역방사계수법을 이용한 Tg 측정키트 2가지(A와 B)를 이용하였다. 검사시료로서는 Tg와 항 Tg 항체 표준용액을 혼합한 시료과 Tg 농도가 높은 환자의 혈청과 항 Tg 항체의 농도가 높은 환자의 혈청을 혼합한 시료를 이용하였다. 검사방법은 A 및 B 키트 모두 제조회사에서 제시한 표준방법을 이용하여 검사를 시행하였다. 통계학적 분석은 ANOVA test 를 이용하였다. 결과: Tg와 항 Tg 항체 표준용액을 혼합한 시료를 이용한 검사 시 두 가지 키트 모두에서 항 Tg 항체가 존재하는 경우 Tg값이 유의하게 낮게 측정되었다. 그러나 A 키트를 이용한 경우 그 정도가 현저하였으며, B 키트를 이용한 경우 임상적으로 의미가 없을 정도로 미약하였다. 환자의 혈청을 이용한 검사에서는 A 키트에서만 Tg측정값이 과소평가되는 결과를 나타내었다. 결론: 항 Tg 항체의 존재는 면역방사계수법을 이용한 혈청 Tg 측정시 과소평가를 일으킬 수 있으며, 그 정도는 사용한 Tg측정 키트에 따라 상이하게 나타남을 알 수 있다. 그러므로 Tg측정 시 항 Tg항체의 측정이 꼭 필요하며, 항 Tg 항체를 가진 혈청에서의 Tg 측정치를 해석할 경우 세심한 주의가 필요하리라 생각된다. 추적검사로 $^{18}F$-FDG PET, 흉부 CT, 그리고, 혈액검사를 시행받았다. PET추적검사 상 이전에 높은 섭취를 보였던 7명 중 6명에서 peak 및 mean SUV의 감소를 보였고 이전에 높은 섭취를 보인 나머지 1명과 낮은 섭취를 보인 1명에서는 병변이 완전히 소실되었다. 이러한 변화 소견은 흉부 CT 추적검사 소견과도 일치하였다. 결론: 원발성 과호산구증가 증후군 환자군에서 폐침범을 보이는 경우, 폐병변은 FDG PET 영상에서 폐암과 유사한정도의 높은 섭취를 보이는 위양성 결과를 나타내어 한번의 PET검사만으로는 양성과 악성을 감별할 수 없었다. 이러한 경우, 추적검사로 CT 및 $^{18}F$-FDG PET를 시행하여 병변의 위치 및 범위, SUV의 변화 소견을 같이 보는 것이 원발성 과호산구증가 증후군 환자에 있어서 보일 수 있는 폐침범 소견과 악성 종양을 감별하는 데 도움을 줄 수 있을 것으로 생각된다. 심벽두꺼워짐의 향상과는 상관성이 없었다. 심근기능의 전부하 후부하에 독립적인 지표인 탄성도는 실제 부피의 증가와 연관되지 않으면서도 생존능이 있는 심근의 기준과 일치하는 양상을 보였으므로 독립적인 매개변수로 사용될 수 있을 것으로 기대한다.높았다. 그러나 두 약제 섭취율 증가의 차이는 동물실험에서는 관찰되지 않았다. 이러한 결과로 보아 MIBI와 tetrofosmin은 Pgp와 MRP에 의한 다약제내성의 발현을 평가할 수 있는 방사성의약품으로 판단되며, 다약제내성 극복제의 시험관내 효능평가에는 MIBI가 tetrofosmin보다 더 우수할 것으로 사료되었다.변화는 없었다. 결론: Verapamil은 암세포의 종류에 따라 MIBI와 TF의 섭취를 감소시켰고, 고용량에는 MDR세포의 섭취도 감소시켰으며 이러한 현상은 세포독성 이나 PKC효소 아형과는 관련이 없었다. 그러므로

재발성 자궁경부 편평상피암 환자들에서 Squamous Cell Carcinoma 항원의 유용성 (The Clinical Significance of Follow Up SCC Levels in Patients with Recurrent Squamous Cell Carcinoma of the Cervix)

  • 최영민;박성광;조흥래;이경복;김기태;김주리;손승창
    • Radiation Oncology Journal
    • /
    • 제20권4호
    • /
    • pp.353-358
    • /
    • 2002
  • 목적 : 자궁경부 편평상피암의 치료 후 추적조사 시에 시행하는 혈중 Squamous Cell Carcinoma (SCC) 항원 검사가 재발의 조기 발견에 도움이 되는지 알아보고자 하였다. 대상 및 방법 : 1997년 1월부터 1998년 12월까지 자궁경부 편평상피암으로 방사선치료를 받고 완전 관해 되었다가 재발된 환자들 중에서 재발 시에 SCC 항원 검사가 이루어졌던 20명을 대상으로 하였다. SCC 항원은 환자의 혈청으로부터 면역효소법으로 측정되었고, 2 ng/mL 미만을 정상으로 하였다. 진단, 추적조사, 재발 시의 SCC 항원값을 조사하여, SCC 항원 검사의 재발에 대한 민감도, 재발 양상에 따른 차이, 재발에 대한 증가 시기, 종양의 크기 및 병기와의 관계 등을 조사하였다. 결과 : 재발된 환자 20명 중의 17명에서 SCC 항원이 정상보다 증가되어 SCC 항원의 민감도는 $85\%$였고, 평균은 15.2 ng/mL (중앙값 : 9.5 ng/mL)였다. 재발 부위별로는 국소 재발, 원격전이, 동시에 발생한 경우 등으로 나누어서 SCC 항원을 비교하였으나 차이가 없었다. 재발을 진단하기 전 6개월 내에 SCC 항원이 검사되었던 11명에서 재발전 SCC 항원은 평균이 13.6 ng/mL (중앙값 : 3.6 ng/mL)였고, 7명에서 정상 보다 높았으며, 정상 범위였던 4명 중의 3명에서 1.5 ng/mL 이상으로 증가되는 양상이었다. 재발된 환자들 중에서 진단 시에 SCC 항원이 검사되었던 16명의 환자들에서 병기 Ib, IIa이면서 4 cm 미만이었던 환자들에 비하여 병기 Ib, IIa이면서 4 cm 이상이거나 병기 IIb, III이었던 환자들에서 진단 당시의 SCC 항원값이 높았다. 결론 : 자궁경부 편평상피암 환자들에서 추적조사 SCC 항원 검사는 재발의 조기 발견에 유용하고, 향후 효과적인 구제치료법이 개발되면 임상적인 이득이 더욱 증가될 것으로 생각된다.y 미만과 그 이상인 경우가 $5.1\%$$22.1\%$, 병기 II 이하인 경우와 III 이상인 경우가 $10.5\%$$31.8\%$였다. 다변량분석에서는 icruCREED 만이 유의하였다(0=0.0432). 등급 1 출혈은 자연적으로 소실되거나(3명) $1\~2$개월의 sucralfate 관장으로 멈추었다. 등급 2의 환자 6명은 $1\~2$개월 동안 sucralfate 관장으로 출혈의 빈도와 양이 줄어들었고 이 중 4명은 전기응고술을 추가로 시행하였다. 다른 9명은 전기응고술을 먼저 시행하였다(4명; sucralfate 관장 병행). 모두 $3\~10$개월 내에 정지되었다. 등급 3의 출혈은 잦은 전기응고술과 수혈을 요하였다. 결론 : 본 연구에서 중등도 이상의 직장출혈빈도가 $8.5\%$로 타 문헌에서 보고된 빈도와 유사한 결과였다. 직장에 조사된 총 생물학적 동등선량이 100 Gy 이상인 경우에 직장출혈이 유의하게 증가하므로, 치료계획시 생물학적 동등선량을 고려함으로써 휴유증 감소에 도움이 될 것으로 생각된다. 직장출혈이 발생한 환자에서 조기에 적극적으로 치료를 시행함으로써 출혈로 인한 불편함을 신속하게 해결하고 이로 인한 심리적 불안감을 해소할 수 있으며 나아가 삶의 질 향상에도 도움을 줄 수 있을 것으로 판단된다.절, 복강림프절 그리고 문합부위 등을 모두 포함하는 좀더 넓은 조사면의 치료가 필요할 것으로 사료된다.장암의 국소제어율을 높일 수 있는 치료방법이 개발되어야 할 것으로 사료된다.어율 모두에 유의한 인자는 방사선치료 후 종양반응과 N 병기였다. 결론 : 조기 병기의 성문상부암에서는 통상적인 방사선단독치료로 후두기능을 보존하면서 수술군과 대등한 종양제어율을 보여주었다. 그러나 진행된 병기의 경우에는 수술과 방사선치료의

기관지결핵의 임상상-201예에 대한 후향적 고찰 (The Clinical Features of Endobronchial Tuberculosis - A Retrospective Study on 201 Patients for 6 years)

  • 이재영;김정미;문두섭;이창화;이경상;양석철;윤호주;신동호;박성수;이정희
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권5호
    • /
    • pp.671-682
    • /
    • 1996
  • 연구배경: 결핵은 아직 우리나라에서 중요한 질병중 하나이고, 기관지결핵은 진단이 용이하지 않고, 기도협착등 합병증을 초래하여 임상적으로 중요성이 인식되어 왔으나 적절한 치료법이 확립되어 있지 않고, 각 보고자마다 내시경적 분류를 다르게 하고 있다. 이에 저자들은 1991년1월 부터 1996년 4월간 한양대학교 부속병원에서 기관지결핵으로 진단된 201예를 대상으로 기관지결핵의 임상상을 알아보고자 하였다. 방법: 1991년 1월 부터 1996년 4월 까지 한양대학교 부속병원에서 기관지내시경으로 기관지결핵으로 진단된 201예를 대상으로 임상상에 대한 후향적 분석을 하여 다음의 결과를 얻었다. 결과: 1) 총 기관지내시경을 실시한 1031예 중 기관지결핵으로 진단된 환자는 201예 (19.5%)였고, 이중 남자 55예, 여자 146예로 여자가 남자에 비해 2.7배 많았다. 연령분포는 20-29세가 61예(30.3%)로 가장 많았으며, 30-39세가 40예(19.9%), 50-59세가 27예(13.4%), 40-49세가 21예(10.4%), 15-19세가 19예(9.5%), 60-69세가 19예(9.5%), 70세 이상이 14예(7.0 %) 순이었다. 2) 증상 및 증후로는 기침 74.5%과 객담 55.2%이 가장 많았으며, 호흡곤란 28.6%, 흉통 19.8%, 발열감 17.2%, 천명음 15.6% 객혈 11.5%순이었다. 3) 방사선 소견으로는 침윤 67.7%, 허탈 43.9%, 동공형성 11.6%, 흉막삼출 7.4% 순이었고, 정상인 예도 6예(3.2%)이었다. 침범부위는 좌상폐야 39.7%, 우상폐야 36.0%, 우중폐야 24.3%, 좌하폐야 21.2%, 좌중폐야 18.5%, 우하폐야 14.8% 순이었다. 4) 폐기능 검사를 실시한 76예의 결과는 정상소견이 44.7%, 제한성 양상이 39.5%, 폐쇄성 양상이 11.8%, 혼합형 양상이 3.9% 순이었다. 5) 기관지내시경 소견으로는 건락성 물질인 백색의 가막형성의 건락성 가막형이 70예 (34.8%)로 가장 많았으며, 점막의 발적 및 부종의 점막형이 54예(26.9%), 과형성성 소견의 파형성형이 52예(25.9%), 섬유화에 의한 협착소견의 섭유화 협착형이 22예(10.9%), 그리고 미란이나 궤양의 궤양형이 3예(1.5%) 순이었다. 6) 각 검사별 양성률은 기관지세척액에서 도말항산균 양성률이 51.2%, 배양양성이 27.4%, 기관지정 조직검사에서 항산균 양성률이 36.4% 항산균이 없는 육아종소견이 13.1%, 만성 염증소견이 36.4%, 확진을 못한 경우가 14.1%였다. 건락성 가막형의 조직검사 검체에서 항산균의 발현과 기관지 세척액에서 결핵군 배양양성률이 각각 44예 중 24예(54.5%; P=0.013), 70예 중 29예(41.4 %; P=0.009)로 높게 나타났다. 결론: 젊은 여성에 있어서 일반 진해제에 잘 반응하지 않는 기침이 오랫동안 지속될시 흉부 액스선 검사가 정상이고, 객담 도말항산균 검사가 음성이더라도 기관지결핵을 의심해야 하고, 확진을 위한 기관지내시경을 실시하여야 한다. 그리고 치료에 반응이 좋지 않은 천식이나, 폐암의 발생이 높은 노년층에 있어서도 감별진단을 위하여 또한 기관지내시경을 실시하여야 한다. 향후 기관지내시경에 의한 기관지결핵의 통일된 분류 및 스테로이드의 항결핵제와의 병용이 기도협착에 미치는 효과에 대한 잘 설계된 대조군 설정의 전향적 연구가 필요하리라 생각된다.

  • PDF

항 바이러스 치료중인 B형 간염환자에서 HBeAg 및 HBV DNA 검출에 관한 분석 (Analysis of HBeAg and HBV DNA Detection in Hepatitis B Patients Treated with Antiviral Therapy)

  • 천준홍;채홍주;박미선;임수연;유선희;이선호
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.35-39
    • /
    • 2019
  • [목적] B형 간염바이러스(hepatitis B virus, HBV)감염은 전세계적으로 중요한 공중 보건 문제이며 만성간염, 간 경변, 간암의 주요 원인으로 알려져 있으며, 이러한 질환의 진단 및 치료에 B형 간염바이러스의 혈청학적 검사는 필수적이다. 항 바이러스 치료중인 B형 간염 환자를 대상으로 면역방사계수 측정법(IRMA; Immunoradiometric assay)과 화학발광 미세입자 면역분석법(CMIA; Chemiluminescent Micropartical Immunoassay)을 이용하여 HBe-Ag 검사를 시행하였고, 실시간 중합효소 연쇄반응(RT-PCR; Realtime-Polymerase Chain Reaction)법을 이용하여 혈청 내 HBV DNA 검출율 을 비교 분석 하였다. [대상 및 방법] 항 바이러스 치료가 시행중인 B형 간염 환자 270명을 대상으로 HBeAg 혈청 검사와 HBV DNA 정량 검사를 실시하였다. HBeAg 혈청 검사는 검출 원리가 다른 두 가지 혈청학적 검사법(IRMA, CMIA)을 적용 하였고, 혈청 내 HBV DNA는 Abbott m2000 System을 사용하여 실시간 중합효소 연쇄반응(RT-PCR; Realtime-Polymerase Chain Reaction)법으로 정량 측정 하였다. [결과] HBeAg 검출율은 면역방사계수법(IRMA)의 경우 24.1% (65/205), 화학발광 미세입자 면역 분석법(CMIA)에서는 82.2% (222/48)의 결과를 보였다. 혈청학적 검사방법(IRMA, CMIA)에 따른 HBeAg 검사결과의 일치율은 33% (89/270)이다. 실시간 중합효소 연쇄반응(RT-PCR)을 이용한 혈청 내 HBV DNA의 검출율은 29.3% (79/191)를 보였고, 혈청 내 HBV-DNA 농도는 $16IU/mL{\times}1.0{\times}10^9IU/mL$ 이며 검출한계는 <15IU/mL 이다. 면역방사계수법(IRMA)으로 HBeAg 검출결과가 양성일때 55.4%, 그리고 음성일때 20.9%의 HBV DNA 검출율과 $1.1{\times}10^8IU/mL$, $5.7{\times}10^5IU/mL$의 혈청내 HBV DNA농도를 나타냈다. 이에 반해 화학발광 미세입자 면역 분석법(CMIA)의 경우 HBeAg 검출결과가 양성일때 HBV DNA 검출율은 28.4%, 음성일때 33.3%의 결과를 나타냈으며 혈청 내 HBV DNA농도는 $6.0{\times}10^7IU/mL$, $2.4{\times}10^5IU/mL$ 이었다. 면역방사계수법과 화학발광 미세입자 면역 분석법에서 동일하게 HBeAg 검출 결과가 양성인 경우 HBV DNA 검출율은 62.3%의 결과를 보였으며, 혈청 내 HBV DNA 농도는 $1.1{\times}10^8IU/mL$ 이다. [결론] 혈청학적 검사법에 따른 HeAg 검출율은 많은 차이를 보였다. 이러한 차이는 검사kit에 사용된 Ab의 특성과 epitope, HBV의 genotype등 여러 가지 원인으로 생각된다. 혈청학적 검사 결과로 분류 된 그룹별 HBV DNA의 검출율과 농도를 비교한 결과, Group II(IRMA 양성, CMIA 양성, N=53)에서 높은 검출율과 농도를 확인할 수 있었다.

인공지능이 의사결정에 미치는 영향에 관한 연구 : 인간과 인공지능의 협업 및 의사결정자의 성격 특성을 중심으로 (A Study on the Impact of Artificial Intelligence on Decision Making : Focusing on Human-AI Collaboration and Decision-Maker's Personality Trait)

  • 이정선;서보밀;권영옥
    • 지능정보연구
    • /
    • 제27권3호
    • /
    • pp.231-252
    • /
    • 2021
  • 인공지능(Artificial Intelligence)은 미래를 가장 크게 변화시킬 핵심 동력으로 산업 전반과 개인의 일상생활에 다양한 형태로 영향을 미치고 있다. 무엇보다 활용 가능한 데이터가 증가함에 따라 더욱더 많은 기업과 개인들이 인공지능 기술을 이용하여 데이터로부터 유용한 정보를 추출하고 이를 의사결정에 활용하고 있다. 인공지능에 관한 기존 연구는 모방 가능한 업무의 자동화에 초점을 두고 있으나, 인간을 배제한 자동화는 장점 못지않게 알고리즘 편향(Algorithms bias)으로 발생되는 오류나 자율성(Autonomy)의 한계점, 그리고 일자리 대체 등 사회적 부작용을 보여주고 있다. 최근 들어, 인간지능의 강화를 위한 증강 지능 (Augmented intelligence)으로서 인간과 인공지능의 협업에 관한 연구가 주목을 받고 있으며 기업도 관심을 가지기 시작하였다. 본 연구는 의사결정을 위해 조언(Advice)을 제공하는 조언자의 유형을 인간, 인공지능, 그리고 인간과 인공지능 협업의 세 가지로 나누고, 조언자의 유형과 의사결정자의 성격 특성이 의사결정에 미치는 영향을 살펴보았다. 311명의 실험자를 대상으로 사진 속 얼굴을 보고 나이를 예측하는 업무를 진행하였으며, 연구 결과 의사결정자가 조언활용을 하려면 먼저 조언의 유용성을 높게 인지하여하는 것으로 나타났다. 또한 의사결정자의 성격 특성이 조언자 유형별로 조언의 유용성을 인지하고 조언을 활용하는 데에 미치는 영향을 살펴본 결과, 인간과 인공지능의 협업 형태인 경우 의사결정자의 성격 특성에 무관하게 조언의 유용성을 더 높게 인지하고 적극적으로 조언을 활용하는 것으로 나타났다. 인공지능 단독으로 활용될 경우에는 성격 특성 중 성실성과 외향성이 강하고 신경증이 낮은 의사결정자가 조언의 유용성을 더 높게 인지하고 조언을 활용하는 것으로 나타났다. 본 연구는 인공지능의 역할을 의사결정과 판단(Decision Making and Judgment) 연구 분야의 조언자의 역할로 보고 관련 연구를 확장하였다는데 학문적 의의가 있으며, 기업이 인공지능 활용 역량을 제고하기 위해 고려해야 할 점들을 제시하였다는데 실무적 의의가 있다.

간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교 (Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma)

  • 강신창;박훈희;김정열;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.3-8
    • /
    • 2010
  • $^{11}C$-Acetate PET/CT는 간에 관련된 병변을 찾아내는데 있어 유용성이 있으며, 이에 대한 예민도는 87.3%에 이른다. 이에 반해 $^{18}F$-FDG PET/CT의 예민도는 47.3%이며, $^{18}F$-FDG와 $^{11}C$-Acetate PET/CT 검사를 동시에 사용하는 경우 예민도는 100%로 보고된바 있다. 하지만 $^{11}C$-Acetate PET/CT검사에서 췌장, 비장의 정상섭취로 인해 $^{18}F$-FDG PET/CT검사에 영향을 줄 수 있어 정확한 진단에 혼란을 야기시킬 수 있다. 본 연구는 이러한 두 방사성의약품의 사용으로 인하여 영상에 얼마나 영향을 주는지에 대해 당일 검사법과 양일 검사법 간의 비교 분석을 통해 유용성을 확인하는데 목적이 있다. 본 연구는 2007년 12월부터 2009년 7월까지 본원에서 간암 진단을 받고 PET/CT 검사를 시행한 환자 46명을 대상으로 하였다(남자 35명, 여자 11명, 평균연령: $54{\pm}10.6$세, 연령 범위: 29~69세). 검사에 이용된 장비는 Biograph TruePoint 40 PET/CT이며, 당일 검사법으로 검사한 21명에게는 $^{11}C$-Acetate PET/CT 검사를 먼저 시행하고 약 1시간 후에 곧바로 $^{18}F$-FDG PET/CT 검사를 시행하였다. 양일 검사법으로 검사를 시행한 25명에게는 1일째 $^{11}C$-Acetate PET/CT검사를 시행하고, 2일째 $^{18}F$-FDG PET/CT 검사를 시행하였다. 두 검사법 간의 $^{18}F$-FDG 영상에서 췌장과 비장에 동일한 관심영역을 설정하고 표준섭취계수를 측정하여 비교 평가하였다. 통계 분석은 SPSS Ver. 17을 사용하였으며, unpaired t-test를 통하여 두 검사법 간의 통계적 유의성을 확인하였다. 각각의 검사법으로 시행한 환자의 영상을 분석한 결과, 양일 검사법으로 검사를 시행한 환자의 췌장 부분의 표준섭취계수 평균${\pm}$표준편차는 두부 $1.62{\pm}0.32$ g/mL, 체부 $1.57{\pm}0.37$ g/mL, 미부 $1.49{\pm}0.33$ g/mL, 비장은 $1.53{\pm}0.28$ g/mL였다. 당일 검사법으로 검사를 시행한 환자의 췌장은 두부 $1.65{\pm}0.35$ g/mL, 체부 $1.58{\pm}0.27$ g/mL, 미부 $1.49{\pm}0.28$ g/mL, 비장은 $1.66{\pm}0.29$ g/mL로 나타났다. 당일 검사법과 양일 검사법 간의 췌장과 비장에서의 표준섭취계수는 통계적으로 유의한 차이를 보이지 않았으며 (p<0.05), PET/CT 영상분석에서도 위양성으로 오인할 수 있는 높은 섭취는 보이지 않았다. 본 연구를 통해서 하루 동안 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사를 시행하여도 $^{18}F$-FDG 영상에서 $^{11}C$-Acetate의 영향으로 인해 표준섭취계수의 과대평가가 일어나지 않는다는 것을 알 수 있었고 이는 표준섭취계수의 측정값을 통해 통계적으로 유의성을 확인할 수 있었다. 앞으로 $^{11}C$-Acetate가 상용화될 경우 $^{18}F$-FDG와 당일 검사법을 이용하여 간질환의 진단에 있어 PET/CT 검사의 진단능을 향상시킬 수 있고 위 결과를 토대로 두 방사성의약품의 간섭영향 없이 하루에 검사를 완료할 수 있으며, 대기시간을 단축하여 환자의 만족도를 높일 수 있을 것으로 사료된다.

  • PDF