• Title/Summary/Keyword: Canal length

Search Result 229, Processing Time 0.026 seconds

A NEW POST REMOVAL TECHNIQUE USING ATD TUGGING DEVICE (ATD automatic bridge remover를 이용한 새로운 포스트 제거 방법)

  • Park, Yun-Woo;Park, Se-Hee;Shin, Hye-Jin;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.215-220
    • /
    • 2005
  • It is common for clinicians to encounter endodontically tl·treated teeth that contain posts within their roots. If endodontic treatment is failed, these posts must be removed to facilitate successful nonsurgical retreatment. There have been many techniques such as ultrasonic instrument, Ruddle post removal system, Eggler post remover and Masserann kit developed to facilitate removal of posts from the root canal space. But these methods may be disadvantageous because long length of time required for post removal and fracture of post or teeth. In now days new post removal technique using ATD automatic bridge remover was introduced. Advantages of this method are simple and short time consuming compare to others. This article served as a successful case report of post removal using ATD automatic bridge remover.

Screw-in forces during instrumentation by various file systems

  • Ha, Jung-Hong;Kwak, Sang Won;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.4
    • /
    • pp.304-309
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Materials and Methods: Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS-k, DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Results: Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest (p < 0.05). Conclusions: Geometrical differences rather than shaping motion and alloys may affect the screw-in force during canal instrumentation. To reduce screw-in forces, the use of NiTi files with smaller cross-sectional area for higher flexibility is recommended.

Clavicle Nonunion: Matchstick Bone-grafting and Osteosynthesis

  • Park, Yong Bok;Yoo, Jae Chul;Park, Geun Min;Kum, Dong Ho;Tauheed, Mohammed;Jeong, Jeung Yeol
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • Background: This study was conducted to evaluate the surgical outcomes of plate fixation using autologous iliac bone graft shaped in the form of a matchstick in clavicle nonunion resulting from prior surgical or non-surgical management. Methods: From May 2005 to February 2013, 17 patients underwent surgery for clavicle nonunion. The mean age at the time of surgery was 48.8 years. The iliac bone was harvested and shaped into slivers approximately 3 cm long, which resembled matchsticks. After opening of the medullary canal, the plate and screws were applied and cancellous bone was placed at the nonunion site. Matchstick bone grafts which were longitudinally placed and encircled on the nonunion site were tied with periosteum using 3-4 stitches. Union was determined via postoperative plane X-ray. Clinical status was evaluated using the visual analogue scale score for pain, and Constant and American Shoulder Elbow Surgeon score. Results: All patients had a stable radiological union at the follow-up. The mean duration from index operation to nonunion operation was 13.2 months (7-32 months). The mean follow-up period was 20.1 months (8-56 months), and the mean duration until union was 11.2 weeks (8-16 weeks). All clinical scores were improved at the final follow-up (p<0.001). The mean segmental defect was $3.3{\pm}2.6mm$ (1-18 mm); and the difference in clavicular length between operative and non-operative site was $5.9{\pm}6.9mm$. Conclusions: Matchstick shaped autologous iliac bone grafting technique in clavicle nonunion is acceptable with a high union rate.

Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators

  • Kim, Pil-Jong;Kim, Hong-Gee;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.113-122
    • /
    • 2015
  • Objectives: The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL). Materials and Methods: The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Results: Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Conclusions: Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

Comparison of cyclic fatigue life of nickel-titanium files: an examination using high-speed camera

  • Ozyurek, Taha;Keskin, Neslihan Busra;Furuncuoglu, Fatma;Inan, Ugur
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.224-231
    • /
    • 2017
  • Objectives: To determine the actual revolutions per minute (rpm) values and compare the cyclic fatigue life of Reciproc (RPC, VDW GmbH), WaveOne (WO, Dentsply Maillefer), and TF Adaptive (TFA, Axis/SybronEndo) nickel-titanium (NiTi) file systems using high-speed camera. Materials and Methods: Twenty RPC R25 (25/0.08), 20 WO Primary (25/0.08), and 20 TFA ML 1 (25/0.08) files were employed in the present study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which has an artificial stainless steel canal with a $60^{\circ}$ angle of curvature and a 5-mm radius of curvature. The files were divided into 3 groups (group 1, RPC R25 [RPC]; group 2, WO Primary [WO]; group 3, TF Adaptive ML 1 [TFA]). All the instruments were rotated until fracture during the cyclic fatigue test and slow-motion videos were captured using high-speed camera. The number of cycles to failure (NCF) was calculated. The data were analyzed statistically using one-way analysis of variance (ANOVA, p < 0.05). Results: The slow-motion videos were indicated that rpm values of the RPC, WO, and TFA groups were 180, 210, and 425, respectively. RPC ($3,464.45{\pm}487.58$) and WO ($3,257.63{\pm}556.39$) groups had significantly longer cyclic fatigue life compared with TFA ($1,634.46{\pm}300.03$) group (p < 0.05). There was no significant difference in the mean length of the fractured fragments. Conclusions: Within the limitation of the present study, RPC and WO NiTi files showed significantly longer cyclic fatigue life than TFA NiTi file.

Effectiveness of endodontic retreatment using WaveOne Primary files in reciprocating and rotary motions

  • Patricia Marton Costa;Renata Maira de Souza Leal;Guilherme Hiroshi Yamanari;Bruno Cavalini Cavenago;Marco Antonio Hungaro Duarte
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.15.1-15.7
    • /
    • 2023
  • Objectives: This study evaluated the efficiency of WaveOne Primary files (Dentsply Sirona) for removing root canal fillings with 2 types of movement: reciprocating (RCP) and continuous counterclockwise rotation (CCR). Materials and Methods: Twenty mandibular incisors were prepared with a RCP instrument (25.08) and filled using the Tagger hybrid obturation technique. The teeth were retreated with a WaveOne Primary file and randomly allocated to 2 experimental retreatment groups (n = 10) according to movement type: RCP and CCR. The root canals were emptied of filling material in the first 3 steps of insertion, until reaching the working length. The timing of retreatment and procedure errors were recorded for all samples. The specimens were scanned before and after the retreatment procedure with micro-computed tomography to calculate the percentage and volume (mm3) of the residual filling material. The results were statistically evaluated using paired and independent t-tests, with a significance level set at 5%. Results: No significant difference was found in the timing of filling removal between the groups, with a mean of 322 seconds (RCP) and 327 seconds (CCR) (p < 0.05). There were 6 instrument fractures: 1 in a RCP motion file and 5 in continuous rotation files. The volumes of residual filling material were similar (9.94% for RCP and 15.94% for CCR; p > 0.05). Conclusions: The WaveOne Primary files used in retreatment performed similarly in both RCP and CCR movements. Neither movement type completely removed the obturation material, but the RCP movement provided greater safety.

Minimally invasive percutaneous endoscopic thoracolumbar foraminotomy in large-breed dogs-a comparative study

  • Soo Hee Lee;Soo Young Choi;Ho Hyun Kwak;Heung Myong Woo
    • Korean Journal of Veterinary Service
    • /
    • v.47 no.2
    • /
    • pp.61-72
    • /
    • 2024
  • This study aimed to evaluate the feasibility of percutaneous endoscopic foraminotomy (PEF) for the treatment of intervertebral disc herniation of the thoracolumbar spine in large-breed dogs by comparing it with open hemilaminectomy (OH). Six large-breed canine cadavers were used in the present study. A barium and agarose mixture (BA-gel) simulating intervertebral disc herniation was injected into the spinal canal at two intervertebral spaces (T12-T13, L2-L3) of the thoracolumbar spine in each cadaver. PEF and OH were randomly allocated to the sites in each cadaver. Computed tomography was performed pre- and postoperatively. The incision length, vertebral window size, procedure time, and amount of simulated disc material removed were recorded to compare PEF and OH. Both procedures clearly exposed the simulated disc material and spinal cord. The size of the incision and vertebral window created after PEF was much smaller than those after OH. The surgical duration of PEF was longer than that of OH. However, no significant difference (P>0.05) was observed in the amount of BA-gel removed between PEF and OH. Thus, PEF could be used as an effective surgical option for intervertebral disc herniation of the thoracolumbar region in large-breed dogs in that it could lead to less tissue damage as well as sufficient removal of the simulated disc material.

SURGICAL EXTRUSION OF THE CROWN-ROOT FRACTURED INCISORS: CASE REPORTS (외과적 정출술을 이용한 치관-치근 파절된 미성숙 영구치의 치험례)

  • Lee, Eun-Mi;Kim, Tae-Wan;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Sun-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.305-312
    • /
    • 2008
  • Crown-root fractures occur throughout both crown and root, and are defined as fractures involving enamel, dentin and cementum. The fractures may be grouped according to pulpal involvement into complicated and uncomplicated one. Crown-root fractures often occur on maxillary anterior teeth and comprise 5% of injuries affecting the permanent dentition and 2% in the primary dentition. To restore crown-root fractured tooth, biologic width must be maintained. For maintaining biologic width, such methods as gingivectomy following osteoplasty or orthodontic extrusion or surgical extrusion are available. Surgical extrusion is a method that extracts the tooth and replants the fractured tooth supragingivally. It is indicated when the length of the crown fragment is less than half the length of the clinical root. In these cases, root canal treatment and crown restoration using light-cured composite resin were performed after surgical extrusion. In following periodic examinations, favorable outcome was observed.

  • PDF

Impact of piezocision on orthodontic tooth movement

  • Papadopoulos, Nikolaos;Beindorff, Nicola;Hoffmann, Stefan;Jost-Brinkmann, Paul-Georg;Prager, Thomas Michael
    • The korean journal of orthodontics
    • /
    • v.51 no.6
    • /
    • pp.366-374
    • /
    • 2021
  • Objective: This study investigated the impact of a single piezocision in the maxillary alveolar process on the speed of tooth movement. The null hypothesis was that the speed of tooth movement will be equal with and without piezocision. Methods: All maxillary molars on one side were moved against the combined incisors in 10 ten-week-old male Wistar rats. Under general anesthesia, a force of 25 cN was applied on either side using a Sentalloy closed coil spring. After placing the orthodontic appliance, vertical corticision was performed using a piezotome under local anesthesia, 2 mm mesial from the mesial root of the first molar on a randomly selected side; the other side served as the control. At the beginning of the treatment, and 2 and 4 weeks later, skull micro-computed tomography was performed. After image reconstruction, the distance between the mesial root of the first molar and the incisive canal, and the length of the mesial root of the first maxillary molar were measured. Moreover, the root resorption score was determined as described by Lu et al. Results: Significantly higher speed of tooth movement was observed on the corticision side; thus, the null hypothesis was rejected. The loss of root length and root resorption score were significantly more pronounced after piezocision than before. A strong correlation was observed between the speed of tooth movement and root resorption on the surgical side, but the control side only showed a weak correlation. Conclusions: Piezocision accelerates orthodontic tooth movement and causes increased root resorption.

Studies on the Morphological Characteristics and Life History of the Chili Fish, Cultriculus eigenmanni (Jordan et Metz) (1) On the Egg Development and the Fry in the Larval Stage (치리(Cultriculus eigenmanni)의 형태 및 생활사에 관한 연구 I. 난발생과 부화자어에 대하여)

  • KIM Eul-Bae;KIM Young-Gill
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.2
    • /
    • pp.151-156
    • /
    • 1984
  • The Chili fish, one of the most common species of the freshwater fishes, is distributed in the river basins of the western coast of Korea. However, any studies on this fish, especially its development or life history, have not been made so far. The authors, therefore, carried out an experiment to reveal some characteristics of egg develoment and fry in this fish. For accomplshing this study, we caught some adult Chili fish by means of a casting net at raceway in the vicinity of Kunsan in June and July, 1983; then, we injected 0. 1 cc Gonadotrophic hormone 1,000 unit solution (Puberogen) in order to induce the spawning on the abdominal cavity of male and female respectively, Approximately 12 hours after injection, the artificially fertilized eggs by using of the dry method and the naturally fertilized eggs were observed simultaneously in the aquarium ($30{\times}50{\times}70cm$). The fertilized eggs, in spherical shape, were sperative, demersel, adhesive nature and $1.38{\sim}1.59\;mm$ in diameter. The light yellow yolk was opaque and $1.17{\sim}l.27\;mm$ in diameter. The hatching of eggs took place at 29.5 hours after fertilization under the condition of $23.5{\sim}25.0^{\circ}C$ water temperature. Basically there were not found so many different aspects in comparison with the common species of Cyprinidae in the development process of eggs : however, there were a few noticable characteristics, that is, pigment cells, eye balls and blood circulation are invisible, or the velocity of egg development is rapid, seemed similar to the Loach's egg. Newly hatched larvae with the yolk sac (2.39 mm in size) were $3.87{\sim}3.99\;mm$ in total length and their myotome number was expressed as 28+15=43. About 20 hours after hatching, a caudal and a pectoral fin as well as an anus began to orgin. In addition, a few malanophore showed on the upper regin of the yolk sac of the larvae whose size was 4.73 mm in total length. The larvae developed about 5.02 mm in total length, and the median fin fold in the abdomen extended forward to two thirds or beyond of the yolk sac at 50 hours after hatching. Simultaneously, the eye balls and mouth also appeared. After 3 days, the yolk sac nearly disappeared, and the larvae (5.4 mm in total length) with perfect eye balls began to swim for themselves for the first time. Also, the specialization between the gill arches and the ailmentary canal, the development of each fins except dorsal fin as well as the blood circulation obviously distinguished in this stage. The larvae whose total length was 5.68 mm was very brisk: also, the development of the dorsal fin rudiment, nearly perfect formation of each organs and the function of the upper and lower jaws were noticeably observed 5 days after hatching.

  • PDF