• 제목/요약/키워드: Canal length

검색결과 229건 처리시간 0.022초

Identification of Non-Muscle Nebulin Isoform in Human Brain Library

  • Joo, Young-Mi;Lee, Min-A;Choi, Pyung-Rak;Choi, Jae-Kyoung;Lee, Yeong-Mi;Choi, Su-Il;Kim, Myong-Shin;Jeon, Eun-Hee;Kim, So-Young;Kim, Chong-Rak
    • 대한의생명과학회지
    • /
    • 제10권1호
    • /
    • pp.23-29
    • /
    • 2004
  • Nebulin is a (Mr 600∼900 kDa) large actin-binding protein specific to skeletal muscle and thought to act as a molecular template that regulates the length of thin filaments. Cardiac muscles of higher vertebrates have been shown earlier to lack nebulin. Recently, full-length nebulin mRNA transcripts have been detected in heart muscle, but at lower levels than in skeletal muscle. Nebulin expression also was detected in the kidney, eye, and otic canal, suggesting that nebulin isoforms may also be expressed in these organs. We have searched for nebulin isoforms in brain of human using PCR and Northern blot. Here, we provide evidence that nebulin mRNA transcripts are expressed in brain. Seven nebulin isoforms (B, C, D, E, F, G and H form) are obtained in human skeletal muscle and four isoforms (B, C, G and H form) in human brain cDNA library. We cloned the 1.3 kb of nebulin fragment from human adult brain library by PCR. The identity of the PCR product was confirmed by sequence analysis. The partial brain nebulin sequence was 99% identical to the skeletal muscle cDNA as determined by Blast alignment. It contains two simple-repeats HR1, HR2 and linker-repeats exon l35∼143 except exon 140. It was different from skeletal muscle B form, which contain HR1 and HR8. These data suggest that nebulin isoform diversity occurs even more extensively than previously known, likely contributing to the distinct thin filament architecture of different striated muscles.

  • PDF

주파수의존형 전자근관장측정기의 정확도에 관한 연구 (The accuracy of the frequency dependent type apex locator)

  • 박주현;노병덕;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.150-160
    • /
    • 1996
  • The present study was to evaluate the accuracy of the frequency dependent type apex locator, Root-ZX. The subjects included 505 root canals of 238 teeth treated by the Department of Conservative Dentistry, and 22 human premolars which were schduled to be extracted for the orthodontic reasons. The results were as follows ; 1. The working lengths determined by Root-ZX were compared with radiographic readings. Of the total 505 root canals, 66 % showed coincidence within ${\pm}0.5mm$ and the average readings of Root-ZX were $0.13mm{\pm}1.05$ longer than those of radiographic readings. 2. The length difference between the file tip determined by Root-ZX and the apical constriction in extracted teeth were measured. Of the total 24 root canals, 70.8 % showed coincidence within ${\pm}0.5mm$ and the average readings of Root-ZX were $0.12mm{\pm}0.50$beyond the apical constriction. 3. The vitality of the teeth did not show any statistical difference(p>0.05) in the accuracy of the Root-ZX readings. The presence of the periapical lesions, however, significantly lowered the percentage of ${\pm}0.5mm$ accuracy in Root-ZX measurements.(p<0.05). In the presence of periapical lesions, the percentage within ${\pm}0.5mm$ was significantly lower.

  • PDF

시멘트의 종류에 따른 포스트의 인장강도 및 제거의 난이도에 관한 연구 (THE EFFECT OF VARIOUS CEMENTS ON THE TENSILE STRENGTH OF A POST AND DIFFICULTIES OF ULTRASONIC POST REMOVAL)

  • 박정원;노병덕;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.181-192
    • /
    • 1997
  • The difficulty of endodontic retreatment depends on various factors and it is affected by retention of post. In this experiment, root canal therapy was done in extracted human teeth and cut into 10mm length from the root apex, and then cemented by zinc phosphate cement, Vitremer$^{(R)}$(glass ionomer) luting cement and Panavia 21$^{(R)}$(resin cement). Post preparation was done by #4 Parapost drill at 6mm length and cement was inserted by lentulo spiral. After 24 hours, tensile bond strength, post removal time was measured after the ultrasonic application and the separation site was measured. The following results were obtained. 1. In measuring tensile bond strength, there is no statistical difference between zinc phosphate cement and Panavia 21$^{(R)}$, but Vitremer$^{(R)}$ showed lower value compared with those two cements. (p<0.001) 2. When the post removal time was measured after ultrasonic application, significant different value in order of Panavia 21$^{(R)}$, zinc phosphate cement and Vitremer$^{(R)}$ was shown. (p<0.001) 3. As a result of examining the separating site of each cement, all 16 of zinc phosphate cement group showed the fracture site between cement and post, Vitremer$^{(R)}$ was 13/16, and Panavia 2$^{(R)}$ was 8/16. In case of tooth restoration using Parapost, the use of Panavia 21 showed good retention property than Vitremer$^{(R)}$, but when retreatment is needed the difficulty of post removal will be increased.

  • PDF

Cone beam형 전산화 단층영상을 이용한 하악전치부 영양관의 연구 (Nutrient canals on mandibular anterior region in cone beam computed tomography)

  • 강정호;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제36권3호
    • /
    • pp.137-143
    • /
    • 2006
  • Purpose : To evaluate location, distribution, diameter, and length of the nutrient canals on mandibular anterior region using a cone beam computed tomography (CBCT). Materials and Methods : Mandibular CBCT was performed on 33 adults (18 males and 15 females) with no history of systemic disease, and any other dental surgery history Location, distribution, diameter, and length of the nutrient canals on mandibular anterior region were radiographically evaluated. A statistical comparison was done by SPSS. Results : In the location and distribution of nutrient canals, they were found in 6.8% at labial portion above root apex, in 93.28% at lingual portion above root apex in 46.2% at labial portion below root apex, and in 53.6% at lingual portion below root apex. Nutrient canals at lingual portion above root apex were most frequently observed between central and lateral incisors, and those at labial and lingual portion below root apex were most frequently observed between central incisors. The mean diameters of nutrient canals were 0.54 mm at labial portion above root apex, 0.61 mm at lingual portion above root apex, 0.66 mm at labial portion below root apex, and 0.76 mm at lingual portion below root apex. The mean lengths of nutrient canals were 2.63 mm at labial portion above root apex, 3.74 mm at lingual portion above root apex, 4.51 mm at labial portion below root apex, and 6.77 mm at lingual portion below root apex. Conclusion : CBCT is useful device to evaluate the anatomical structure of nutrient canals on mandibular anterior region.

  • PDF

감염 근관에서 분리된 연쇄구균의 16S Ribosomal DNA 중합효소 연쇄반응과 제한효소 절단길이 다형성에 관한 연구 (POLYMERASE CHAIN REACTION AND RESTRICTION FRAGMENT LENGTH POLYMORPHISM OF 16S RIBOSOMAL DNA OF STREPTOCOCCI ISOLATED FROM INFECTED ROOT CANALS)

  • 정희일;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.577-609
    • /
    • 1995
  • Bacteria have been regarded as one of the most important factors in pulpal and periapical diseases. Streptococci are frequently isolated facultative anaerobes in infected root canals. Recently molecular biological techniques have been rapidly progressed. This study was designed to apply the molecular biological tools to the identification and classification of streptococci in the endodontic microbiology. Streptococci isolated from infected root canals were identified with both Vitek Systems and API 20 STREP. Identification results were somewhat different in several strains of streptococci. Eighteen streptococci and enterococcal was difficult so to digest plasmid DNA using Hind III and EcoRI to differentiate strains by restriction enzyme analysis of plasmid DNA. 16S rDNA of chromosome was amplified by polymerase chain reaction(PCR) and then restricition fragment length polymorphism(RFLP) using several restriction enzymes was observed. The molecular mass of 16S rDNA of chromosomal DNA was approximately 1.4kb. There were three to five RFLP patterns using eight restriction enzymes. RFLP patterns digested with CfoI which recognizes four base sequences were identical in all stains. Hind III which recognizes six base sequences could not digest the 16S rDNA. Restriction enzymes which recognize five base sequences were suitable for RFLP pattern analysis. At least three different restriction enzymes were needed to compare each strains. 16S rDNA PCR-RFLP was simple and rapid to differentiate and classify strains and could be used in the epidemiological study of root canal infections.

  • PDF

Clinical and radiographic outcomes of regenerative endodontic treatment performed by endodontic postgraduate students: a retrospective study

  • Hadi Rajeh Alfahadi;Saad Al-Nazhan; Fawaz Hamad Alkazman;Nassr Al-Maflehi; Nada Al-Nazhan
    • Restorative Dentistry and Endodontics
    • /
    • 제47권2호
    • /
    • pp.24.1-24.15
    • /
    • 2022
  • Objectives: Regenerative endodontic treatment is a clinical procedure aimed at biologically regenerating damaged root canal tissue of immature permanent teeth. This study aimed to report the outcomes of regenerative endodontic treatment performed by endodontic postgraduate students. Materials and Methods: Clinical and radiographic data of 27 patients, aged 10-22 years, who underwent regenerative treatment of immature permanent teeth from 2015 to 2019 were followed up, wherein clinical and radiographic examinations were performed for each patient. Postoperative success rate and tooth survival were analyzed, and the postoperative radiographic root area changes were quantified. Results: A total of 23 patients attended the dental appointments, showing that all teeth survived and were asymptomatic. Specifically, 7 periapical pathosis cases were completely healed, 12 were incompletely healed, and 4 cases failed. Moreover, significant differences were found between discolored and non-discolored teeth, and between the presence or absence of periapical radiolucency. Additionally, 3 anterior teeth showed complete closure of the apical foramen, while the apical foramen width was reduced in 17 teeth and failed in 3 teeth. Root length was also found to have been increased in 7 anterior and 4 posterior teeth, and the average length ranged from 4.00-0.63 mm in the anterior teeth, 2.85-1.48 mm of the mesial root, and 2.73-2.16 mm of the molar teeth distal root. Furthermore, calcified tissue deposition was observed in 7 teeth. Conclusions: A favorable outcome of regenerative endodontic treatment of immature permanent teeth with necrotic pulp was achieved with a high survival rate.

맞춤형 인공관절 설계를 위한 인체 고관절의 3차원 형상 정보 추출 (Extracting 3D Geometry Parameters of Hip Joint for Designing a Custom-Made Hip Implant)

  • 서정우;전용태
    • 한국CDE학회논문집
    • /
    • 제13권3호
    • /
    • pp.200-208
    • /
    • 2008
  • Total Hip Replacement(THR) is a surgical procedure that replaces a diseased hip joint with a prosthesis. A plastic or metal cup forms the socket, and the head of the femur is replaced by a metal ball on a stem placed inside the femur. Due to the various types and shapes of human hip joint of every individual, a selected commercial implant sometimes may not be the best-fit to a patient, or it cannot be applied because of its discrepancy. Hence extracting geometry parameters of hip joint is one of the most crucial processes in designing custom-made implants. This paper describes the framework of a methodology to extract the geometric parameters of the hip joint. The parameters include anatomical axis, femoral head, head offset length, femoral neck, neck shaft angle, anteversion, acetabulum, and canal flare index. The proposed system automatically recommends the size and shape of a custom-made hip implant with respect to the patient's individual anatomy from 3D models of hip structures. The proposed procedure creating these custom-made implants with some typical examples is precisely presented and discussed in this paper.

슬관절 재전치환술용 경골삽입물 형상이 접촉압력 분포에 미치는 영향 (Effect of stem design on contact pressure distribution of end-of-stem in revision TKR)

  • 김윤혁;구교민;권오수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.179-180
    • /
    • 2006
  • In this study, the effect of stem-end design on contact pressure and stress distribution in revision TKR was investigated using finite element method. The finite element model of tibia, including the cortical bone, the cancellous bone and canal, was developed based on CT images. The stem models with various stem lengths, diameters and frictional coefficients, and press-fit effects were considered. The results showed that the longer stem length, the stronger press-fit, the bigger stem diameter, and the higher frictional coefficient increased both peak contact pressure and the highest Von-Mises stress values. We hypothesized that peak contact pressure and Von-Mises stress distribution around the stem, may be related to the stem end pain. The results of this study will be useful to design the stem endand reduce the end-of-stem pain in revision TKR.

  • PDF

도롱뇽(Hynobius leechii) 정충의 미세구조(Amphibia, Urodela) (Ultrastructure of Spermatozoa in Urodeles, Hynobius leechii (Amphibia: Urodela))

  • 김구환;박원학;이영환
    • Applied Microscopy
    • /
    • 제25권1호
    • /
    • pp.111-121
    • /
    • 1995
  • The ultrastructure of spermatozoa in Hynobius leechii was examined with transmission electron microscope and compared with those of other urodeles and anurans. The perforatorium and the tail show most of the common feature of urodeles. However, there were several ultrastructural characteristics in an acrosome, nucleus, neck, axial rod and mitochondria related to the nucleus. The acrosome was trifoliate in transverse sections and the perforatorium consisted of two different concentric parts with a fine sharp point in a subacrosomal lumen. The nucleus consisted of two different regions of chromatin area and nuclear ridge. The nuclear ridge was composed of several bundles of five to ten minute tubular subunits of 19 nm diameter in this species, while in higher urodeles it was well developed in multi layers. The protoplasmic bead was separated by a cytoplasmic canal except the connection with only the distal portion of the nucleus. The neck was a short cylinder and contained pericentriolar material with transverse striations. In Hynobius the ring was not elongated to the tail and the mitochondria were distributed only in the protoplasmic bead around the nucleus as in Cryptobranchus, while in higher groups of urodeles it elongates to the length of the middle piece and the mitochondria follow the ring. The ring elongation may be related to the distribution of mitochondria. Hynobiidae and Cryptobranchidae are closely related based on structure of neck, the axial rod and location of mitochondria, although they are different in the composition of the axial rod.

  • PDF

삼각형 래버린스 위어의 유량계수 산정 (Estimation of Discharge Coefficient for Triangle Shape Labyrinth Weir)

  • 송재우;이진은;임장혁
    • 한국방재학회 논문집
    • /
    • 제9권2호
    • /
    • pp.87-93
    • /
    • 2009
  • 래버린스 위어는 마루부의 형상이 직선이 아닌 위어로 월류 폭을 증가시켜 월류량을 증대시키는 수공구조물이다. 최근 강우량 증가에 의한 댐 여수로의 개선 및 관개시설 및 운하관련 수공구조물 등 래버린스 위어의 활용범위는 다양하고 이에 관한 연구가 필요한 실정이다. 본 연구의 목적은 수리모형실험을 통해 삼각형 래버린스 위어 형상에 따른 수리특성 및 유량특성을 분석하여, 삼각형 래버린스 위어의 유량계수식을 제시하는데 있다. 본 연구에서 제시된 유량계수식은 상관계수, 잔차의 합, 평균절대오차율을 분석한 결과 적용성이 있는 것으로 나타나 댐의 여수로 및 관개시설 등 수공구조물 설계에 적용이 가능할 것이다.