• 제목/요약/키워드: Canal length

검색결과 229건 처리시간 0.026초

꼬치동자개 (Pseudobagrus brevicorpus) 정자의 미세구조와 계통적 고찰(경골어류, 메기목, 동자개과) (Ultrastructure of Spermatozoa of the Slender Catfish, Pseudobagrus brevicorpus (Teleostei, Bagridae) with Phylogenetic Considerations)

  • 김구환;이준일
    • 한국수산과학회지
    • /
    • 제36권5호
    • /
    • pp.480-485
    • /
    • 2003
  • Morphology of the spermatozoa from the testes of the catfish (Pseudobagrus brevicorpus) was studied by transmission and scanning electron microscopy. The spermatozoa of P. brevicorpus are approximately $82.25\pm0.06\;{\mu}m$ in length and relatively simple cells composed of a spherical head, a short midpiece and a tail as in most teleost fish, The nucleus measuring about $2.00\pm0.02\;{\mu}m$ in length is depressed with a deep nuclear fossa of about $1.05\pm0.03\;{\mu}m$ in length three fifths of the nuclear length. The nuclear fossa contains the proximal and distal centrioles. The two centrioles are oriented approximately $150^{\circ}$ to each other. The mitochondria are arranged in two layers and their number is 12 or more. They are separated from the axoneme by the cytoplasmic canal. The axoneme is the 9+2 microtubular pattern and has inner but no outer dynein arms as in other bagrids. The axonemal fins were the closed to axonemal doublet 3 and 8. The axonemal fins and lost outer dynein arm are shared in Bagridae and the deep nuclear fossa is shared in Siluriformes. The axonemal fins observed in Bagridae and Amblycipitidae of Siluriformes might be the apomorphic character in Ostariophysi.

하악의 전산화 단층사진에서 횡단면이 임플랜트를 위한 가용골 높이의 결정에 미치는 영향 (The Effect of the Axial Plane on Measurement of Available Bone Height for Dental Implant in Computed Tomography of the Mandible)

  • 진민주
    • Journal of Periodontal and Implant Science
    • /
    • 제32권2호
    • /
    • pp.379-388
    • /
    • 2002
  • 임플랜트의 성공을 위해서 정확한 방사선학적 검사는 가용골의 높이와 하악관의 위치를 평가하고 중요구조물의 손상을 방지하는데 있어 필수적이다. CT촬영법 중 영상재구성법을 이용한 방법(CT/MPR)은 하악관의 위치를 잘 보여준다. 치아에 평행한 협설 단면 (cross-sectional plane)을 얻기 위해서는 횡단면(axial plane)이 교합면과 평행하도록 해야 한다. 횡단면(axial plane)이 교합면과 평행하지 않으면 재구성된 협설 단면(cross-sectional plane)은 계획된 fixture의 방향과 각을 이루게 되어 그 fixture의 실제 dimension을 보여주지 못하게 된다. 협설단면(cross-sectional view)에서 측정한 가용골 높이가 실제 가용골 높이보다 너무 큰 경우, 수술시 하악관을 침범할 가능성이 있게 된다. 이 연구의 목적은 하악 임플랜트 CT 촬영시 횡단면이 임플란트를 위한 가용골 높이의 측정에 미치는 영향을 알아보는 것이다. 하악 대구치 부위의 임플랜트를 계획하고 radiographic stent를 만든 후 치과 방사사선과에서 하악 임플랜트 CT를 촬영한 40명의 환자, 45개 부위를 선택하였다. 임플랜트 CT의 central panoramic view에서 치조정과 하악관, stent를 tracing한 후, 치조정과 하악관간의 거리(available bone height, ABH)를 재구성된 협설단면상에서 측정하였다(uncorrected ABH). 다음으로, .stent 방향으로 그은 직선상에서 측정하였다(corrected ABH). 두 거리사이의 각을 측정하였다. 두 거리로부터 각각 fixture의 길이를 결정하였다. 연구 결과, 두 가용골의 높이간에는 제 1 대구치와 제 2 대구치에서 모두 유의성있는 차이를 보였다 (p<0.001). 차이가 1 mm 이상인 경우는 제 1 대구치에서 8.7%, 제 2 대구치에서 15.5% 였다. 차이가 2 mm 이상인 경우는 제 1 대구치에서 2.0%, 제 2 대구치에서 6.6%였다. 최대값은 제 1 대구치에서 2.5 mm, 제 2 대구치에서 2.2 mm 였다. 두 가용골의 높이차와 각과의 상관 관계는 제 1 대구치와 제 2 대구치에서 모두 양의 상관관계를 보였다. 상관 계수는 제 1 대구치에서 0.534, 제 2 대구치에서 0.728 였다. 제 2 대구치가 더 강한 양의 상관관계를 보였다. 두 가용골의 높이로부터 결정한 fixture의 길이가 일치하지 않는 경우는 제 1 대구치에서는 24.4%, 제 2 대구치에서는 28.9%였다.

상아질 결합제로 처리된 수산화칼슘 plug의 근단부 폐쇄능에 관한 연구 (AN EXPERIMENTAL STUDY ON THE SEALING ABILITY OF A CALCIUM HYDROXIDE PLUG TREATED WITH DENTIN BONDING AGENT)

  • 김평식;황호길;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.187-201
    • /
    • 1996
  • The purpose of this study was to evaluate the sealing ability of a calcium hydroxide plug treated with a bonding agent. Ninety extracted human anterior teeth and premolars with single canal were used in this study. Crowns were removed. the canal's were instrumented. and the roots were randomly divided into three groups of 30 each. In control group. a single apical seat was prepared with #60 K file 1mm short of the apex and the root canal was obturated with Gutta-percha and Sealapex by the lateral condensation method. In experimental group 1 and group 2. to prepare an apical isthmus of 1mm in length. the first apical seat was prepared with a #45 K file 1mm short of the anatomical apex and with a #60 K file 2mm short for the second apical seat. Dry calcium hydroxide powders were packed in the apical isthmus with a hand plugger and #60 K file and then. the root canal was obturated with Gutta-percha and Seal apex by the lateral condensation method. In experimental group 2. following an application of the bonding agent to the plug. the root canal was obturated in the same way. The teeth of each group were immersed in a 2% methylene blue dye solution. for 1, 2, and 4 weeks. The distance from the tip of the cone to the deepest penetration was measured using the Tool maker's microscope. The results were as follows : 1. The teeth having the calcium hydroxide plug treated with the dentin bonding agent (experimental group 2) showed the lowest leakage with 1.4705mm and the control group without apical plug(no apical isthmus) showed the highest leakage with 3.1735mm. 2. The control group without apical plug showed higher leakage than experimental group 1 having the calcium hydroxide plug treated without the dentin bonding agent(p>0.05). 3. The control group without apical plug and experimental group 1, having the calcium hydroxide plug treated without the dentin bonding agent. showed higher leakage than experimental group 2. having the calcium hydroxide plug treated with the dentin bonding agent(p<0.001). 4. The immersion time had no significant effect on the degree of leakage. In conclusion, the results showed that the calcium hydroxide plug treated with the dentin bonding agent could decrease the microleakage from the root apex effectively.

  • PDF

접착제의 접착변수가 레진계 근관충전제의 근단밀폐효과에 미치는 영향 (The effects of total-etch, wet-bonding, and light-curing of adhesive on the apical seal of a resin-based root canal filling system)

  • 류원일;손원준;백승호;이인한;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제36권5호
    • /
    • pp.385-396
    • /
    • 2011
  • 연구목적: 본 연구는 치근벽의 전처리 개념과 접착제의 중합방법이 레진계 근관충전제의 치근단 밀폐능에 미치는 영향을 평가하였다. 연구 재료 및 방법: 3가지 다른 접착변수를 조합하여 충전한 Resilon-RealSeal 시스템의 근단미세누출을 색소침투법을 이용하여 통상의 가타퍼쳐 충전과 비교하였다. 실험군은 자가부식형 RealSeal primer와 이중중합형 RealSeal sealer를 이용하여 Resilon 충전한 SEDC군, 산부식없이 Scotchbond Multi-Purpose primer를 적용한 후 접착제는 광중합하고 Resilon을 충전한 NELC군, 및 Scotchbond Multi-Purpose의 접착강화제와 접착제를 total etch/wet bonding과 광중합의 술식을 정확하게 지켜서 Resilon을 충전한 TELC군으로 구분하였다. 대조군(GPCS)에서는 통상의 AH26 plus sealer를 사용하여 가타퍼쳐를 충전 하였다. 결과: 치아장축방향의 색소침투는 TELC군에서 GPCS군과 SEDC군에 비해 유의하게 작았다(Kruskal-Wallis test, p < 0.05). 횡단면의 미세누출 점수도 TELC군이 근첨으로부터 2 - 5 mm의 범위에서 다른 군에 비해 유의하게 낮았다(Kruskal-Wallis test, p < 0.05). 결론: 레진계 근관충전제를 사용 시에는, 자가부식형 전처리제와 이중중합형 sealer보다는, total etch/wet bonding 개념과 적절한 광중합을 도모하는 전처리제 및 접착제의 사용이 치근단 미세누출을 감소시키므로 추천된다.

전동 file을 장착한 Tri Auto ZX®의 치근단공 인지 정확도 평가 (ACCURACY OF TRI AUTO ZX® IN LOCATING APICAL FORAMEN WITH ROTARY FILE)

  • 박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.578-584
    • /
    • 1999
  • The purpose of this experiment was to determine: (1) the safe automatic apical reverse setting that prevents overinstrumentation of the root canal, using Tri Auto ZX$^{(R)}$ and (2) the effect of various irrigant on such instrumentation. The instrumentation was carried out with the automatic apical reverse setting of 0.5, 1.0, 1.5, and 2.0. The root canal irrigants used in usual manner were normal saline(0.9%), NaOCl(2.5%), and RC Prep$^{(R)}$. For each reverse setting and each irrigant, ten teeth were used with the total of 120 teeth. The distance between the file tip and the apical constriction was determined by stereomicroscope using the point that the file began to rotate in reverse direction. When the reverse setting mode was set to 0.5, 18 of 30 were overinstrumented. If these were discriminated by irrigant, 10 of 6 with 0.9% saline, 10 of 6 with NaOCl, and 10 of 6 with RC Prep$^{(R)}$ has the file tip located 0.57${\pm}$0.30mm, 0.73${\pm}$0.39mm, and 0.26${\pm}$0.25mm beyond the apical constriction respectively. In 1.0 setting 15 of 29 were over the apical constriction, and the distribution was 6 in saline, 5 in NaOCl, and 4 in RC Prep$^{(R)}$. The mean distance over the apical constriction was 0.28${\pm}$0.13mm with saline, 0.75${\pm}$0.61mm with NaOCl, and 0.25${\pm}$0.17mm with RC Prep$^{(R)}$. When the autoatic reverse mode was set to 1.5, and 2.0, 5, and 1 teeth were found to be overinstrumented in respective settings. But there were large variations in overinstrumented distances when an attempt was made to compare the effect of irrigants on this overinstrumentations and they were meaningless for the small sample size. When all of the autoreverse setting were combined to compare the number of overinstrumented teeth with each irrigant, there were no significant differences (14 for normal saline, 12 for NaOCl, 13 for RC Prep$^{(R)}$). When 0.5 or 1.0 automatic apical reverse setting mode was used the Tri Auto ZX$^{(R)}$ in clinical application, the possibility of overinstrumentation beyond the apical constriction exists in 55.9% of cases. Therefore 1.5 or 2.0 setting is safer for the preparation inside the canal but this type setting needs additional apical hand preparation of the root canal because the accuracy is lower than 0.5 or 1.0 setting.

  • PDF

근관세정 방법에 따른 수산화칼슘 제재의 제거 효율 비교 (A COMPARISON OF THE IRRIGATION SYSTEMS IN CALCIUM HYDROXIDE REMOVAL)

  • 은재승;박세희;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제34권6호
    • /
    • pp.508-514
    • /
    • 2009
  • 이 실험의 목적은 근관 내에 충전된 수산화칼슘의 제거 시 치근단 1/3에서 기존의 근관세정법과 $EndoActivator^{(R)}$, $EndoVac^{(R)}$ system의 세정 효율을 비교하고, 근관 세정 중 치근단공 개방 확인의 영향에 대해 평가하고자 함이다. 60개의 단근치를 사용하였고 ISO #35까지 근관성형 후 수산화칼슘을 충전하였다. 근관 세정법과 치근단공 개방 확인 유무에 따라 6개 실험군으로 나누어 세정하였다. 실험 치아를 양분하여 치근단 3 mm에서 근관 면적에 대한 잔존 수산화칼슘 면적의 백분율을 측정하였다. 실험결과 $EndoActivator^{(R)}$, $EndoVac^{(R)}$군이 기존의 근관 세정법 군에 비해 유의하게 높은 제거효율을 나타냈으며 (p<0.05), 치근단공 개방 확인 유무에 따른 유의한 차이는 나타나지 않았다. 이 실험 결과에 따르면 기존의 근관세정법으로 효과적인 세정이 불가능했던 근관의 치근단 1/3부위에서 $EndoActivator^{(R)}$, $EndoVac^{(R)}$ system과 같은 근관 세정법이 효과적인 대안이 될 수 있다는 결론을 얻었다.

구강병소에 대한 펄스형 Nd: YAG 레이저의 치료효과 (The Therapeutic Effects of a Pulsed Nd:YAG Laser on Oral Lesions)

  • 신금백
    • Journal of Oral Medicine and Pain
    • /
    • 제22권2호
    • /
    • pp.309-325
    • /
    • 1997
  • In order to set the lasing variables and evaluate, clinically, the therapeutic effects of a pulsed Nd:YAG laser on oral lesion, the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (wavelength 1064nm, Pulse duration 120$\mu$sec, fiber diameter 200$\mu$m/320$\mu$m) to 22 cases of oral soft tissue lesions and 6 cases of oral hard tissue lesions. The obtained results were as follows : 1. The effective excision with contact mode and the effective hemostasis of accompanied bleeding with noncontact mode were occurred by lasing on oral soft tissue lesions with fiber diameter of 320$\mu$m under the variables of 2.0~4.0W and 20~50Hz which were controlled into high power/low pulses for excision, low power/high pulses for hemostasis, low power in granulation tissue and high power in fibrous tissue according to therapeutic goals and tissue conditions. 2. About 50% of decreasing effect on hypersensitivity was occurred by lasing with non-contact and contact mode on cervical abrasion which caused dentinal hypersensitivity with fiber diameter of 320$\mu$m under the variables of 0.7 - 1.0W and 10Hz which were applied 2~3 times with 1 week interval. 3. The effective sterilization of infected root canal and lesion of periapical abscess was occurred by lasing with contact and spiral modes on wall of root canal and periapical abscess with fiber diameter of 200$\mu$m of which the tip was placed about 1mm shorter than root canal length under the variables of 1.OW and 10Hz.

  • PDF

Dentinal defects induced by 6 different endodontic files when used for oval root canals: an in vitro comparative study

  • Pawar, Ajinkya M;Thakur, Bhagyashree;Kfir, Anda;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.31.1-31.9
    • /
    • 2019
  • Objectives: To compare the formation of dentinal defects using stainless-steel hand K-files (HFs), rotary files, reciprocating files, and Self-Adjusting File (SAF), when used for oval root canals. Materials and Methods: One hundred and forty extracted human mandibular premolar with single root and oval canal were selected for this study. Oval canals were confirmed by exposing to mesio-distal and bucco-lingual radiographs. Teeth with open apices or anatomic irregularities were excluded. All selected teeth were de-coronated perpendicular to the long axis of the tooth, leaving roots segments approximately of 16 mm in length. Twenty teeth were left unprepared (control), and the remaining 120 teeth were divided into 6 groups (n = 20) and instrumented using HF (size 40/0.02), Revo-S (RS; size 40/0.06), ProTaper NEXT (PTN; size 40/0.06), WaveOne (WO; size 40/0.09), RECIPROC (RC; size 40/0.06), and the SAF (2 mm). Roots were then sectioned 3, 6, and 9 mm from the apex, and observed under stereomicroscope, for presence of dentinal defects. "No defect" was defined as root dentin that presented with no visible microcracks or fractures. "Defect" was defined by microcracks or fractures in the root dentin. Results: The control, HF, and SAF did not exhibit any dentinal defects. In roots instrumented by RS, PTN, WO, and RC files exhibited microcracks (incomplete or complete) in 40%, 30%, 55%, and 50%, respectively. Conclusions: The motor-driven root canal instrumentation with rotary and reciprocating files may create microcracks in radicular dentine, whereas the stainless-steel hand file instrumentation, and the SAF produce minimal or less cracks.

신생아의 항문직장내압검사 (Anorectal Manometry in Normal Neonates)

  • 서정민;최윤미;이은희;전용훈;안승익;홍기천;신석환
    • Advances in pediatric surgery
    • /
    • 제5권2호
    • /
    • pp.103-110
    • /
    • 1999
  • To estimate the normal anal canal pressure in neonates, anal manometry was performed in 46 normal babies less than 6 days of age. Twenty-eight of the subjects were boys and 18 girls. All the subjects passed meconium within 24 hours after birth. Birth weights were above 2.4 kg. There were no sexual differences in birth weight, birth height, gestational age, postnatal age, or Apgar score (p<0.05). The mean manometry values were; anal sphincter length $18.6{\pm}3.9$ mm, high pressure zone (HPZ) $9.2{\pm}3.6$ mm, vector volume $2027.2{\pm}2440.7$ mmHg2cm, maximum pressure $42.3{\pm}17.4$ mmHg, and position of the maximum pressure $6.0{\pm}22.4$ mm. Only the HPZ of boys was longer than those of girls (p=0.005). In squeezing state, HPZ and the position of maximun pressure were not changed from resting state. HPZ, vector volume, and maximum pressure in boys were higher than those in girls. As the birth weight increased, the anal sphincter length (p=0.001) and the HPZ increased (p=0.047). The resting pressures of the anal canal were evaluated in three portions; /23 upper portion, $12.8{\pm}8.6$ mmHg, middle portion, $20.3{\pm}10.8$ mmHg, and lower portion, $26.1{\pm}12.9$ mmHg. These normal values may serve as guidelines for the evaluation, diagnosis and treatment of neonatal anal diseases.

  • PDF

In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen

  • Tampelini, Fernanda Garcia;Coelho, Marcelo Santos;de Azevedo Rios, Marcos;Fontana, Carlos Eduardo;Rocha, Daniel Guimaraes Pedro;Pinheiro, Sergio Luiz;da Silveira Bueno, Carlos Eduardo
    • Restorative Dentistry and Endodontics
    • /
    • 제42권3호
    • /
    • pp.200-205
    • /
    • 2017
  • Objectives: The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Materials and Methods: Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a ${\times}25$ magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. Results: The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05). Conclusions: Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.