  • To diagnose vascular diseases from the viewpoint of hemodynamics, detailed quantitative hemodynamic information of related blood flows with a high spatial resolution of tens micrometer and a high temporal resolution in the order of millisecond were required. For investigating the hemodynamic phenomena of vascular circulatory diseases, a new diagnosing technique combining a medical radiography and PIV method was newly developed. This technique consisted of a medical X-ray tube, an X-ray CCD camera, a shutter module for double pulse-type X-ray source, and a synchronizer. Through several preliminary tests, the feasibility of the angiographic PIV technique was verified. For in-vivo measurements to real blood flows, we developed tracer microcapsules which were optimized to this system by encapsulating a contrast material of iodine with a matrix material of PVA (polyvinylpyrrolidone). In near future, the angiographic PIV technique would be useful for diagnosing hemodynamic phenomena of vascular diseases and for their early detection.

  • PDF

A Comparative Study on Atrial Fibrillation Detection between Clinical Study and Automatic Diagnosis using a Smartphone Camera in Koreans (한국인을 대상으로 스마트폰 카메라를 이용한 자동진단과 임상실험 간의 심방세동 검출에 대한 비교 연구)

  • Kong, Youngsun;Jung, Jaehong;Choi, Hyungoh;Moon, Chanki;Nam, Yunyoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.541-543
    • /
    • 2015
  • 최근 스마트폰 카메라를 이용하여 심방세동을 진단하기 위해 PPG를 이용하여 Pulse Peak 사이의 간격을 구하고 RMSSD와 섀넌 엔트로피를 이용하여 불규칙 정도를 계산하는 연구가 활발히 진행되고 있다. 본 논문에서는 심방세동 환자와 정상인을 포함한 한국인을 대상으로 스마트폰을 이용한 심방세동 검출을 실험하고 정확률을 계산하였다. 심방세동 환자를 포함한 한국인 29명을 대상으로 PPG 신호를 수집하여 실험하였다. 실험결과에서 정확률 85.18%를 보였다.

EXTRACTING OUTLINE AND ESTIMATING HEIGHT OF LAND FEATURES USING LIDAR DATA

  • Lee, Woo-Kyun;Song, Chul-Chul
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.181-183
    • /
    • 2006
  • Digital topographic map in Korea contains layers of spatial and attribute data for 8 land features such as railroads, watercourses, roads, buildings and etc. Some of the layers such as building and forest don't include any information about height, which can be just prepared by interpretation of remote sensed data or field survey. LiDAR(Light Detection And Ranging) data using active pulse and digital camera provides data about height and form of land features. LiDAR data can be used not only to extract the outline of land features but also to estimate the height. This study presents technical availability for extraction and estimation of land feature's outline and height using LiDAR data which composes of natural and artificial land features, and digital aerial photograph which was taken simultaneously with the LiDAR. The estimated location, outline and height of land features were compared with the field survey data, and we could find that LiDAR data and digital aerial photograph can be a useful source for estimating the height of land features as well as extracting the outline.

  • PDF

In vitro application of Angiographic PIV technique to blood flows (Angiographic PIV 기법을 이용한 혈액유동의 in-vitro 연구)

  • Kim, Guk-Bae;Lim, Nam-Yun;Jung, Sung-Yong;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.105-108
    • /
    • 2007
  • To diagnose the vascular diseases from the viewpoint of hemodynamics, we need detailed quantitative hemodynamic information of related blood flows with a high spatial resolution of tens micrometer and a high temporal resolution in the order of millisecond. For investigating in-vivo hemodynamic phenomena of vascular circulatory diseases, a new diagnosing technique combining a medical radiography and PIV method was newly developed. This technique called 'Angiographic PIV system' consists of a medical X-ray tube, an X-ray CCD camera, a shutter module for generating double pulse-type X-ray, and a synchronizer. Through several preliminary tests, the feasibility of the Angiographic PIV technique was verified. For in-vivo applications to real blood flows, we developed tracer microcapsules, which were optimized to this system, made of a contrast material of iodine and a matrix material of PVA (polyvinylpyrrolidone). In near future, the Angiographic PIV technique will be used for understanding hemodynamic phenomena of vascular diseases and for their early detection.

  • PDF

A Brazing Defect Detection Using an Ultrasonic Infrared Imaging Inspection (초음파 열 영상 검사를 이용한 브레이징 접합 결함 검출)

  • Cho, Jai-Wan;Choi, Young-Soo;Jung, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.426-431
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material in real time. In this paper a realtime detection of the brazing defect of thin Inconel plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (23 kHz) ultrasonic transducer was used to infuse the welded Inconel plates with a short pulse of sound for 280 ms. The ultrasonic source has a maximum power of 2 kW. The surface temperature of the area under inspection is imaged by an infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the bound between the two faces of the Inconel plates near the defective brazing point and heated up highly, are observed. And the weak thermal signal is observed at the defect position of brazed plate also. Using the image processing technology such as background subtraction average and image enhancement using histogram equalization, the position of defective brazing regions in the thin Inconel plates can be located certainly.

Real-time Vital Signs Measurement System using Facial Image Data (안면 이미지 데이터를 이용한 실시간 생체징후 측정시스템)

  • Kim, DaeYeol;Kim, JinSoo;Lee, KwangKee
    • Journal of Broadcast Engineering
    • /
    • v.26 no.2
    • /
    • pp.132-142
    • /
    • 2021
  • The purpose of this study is to present an effective methodology that can measure heart rate, heart rate variability, oxygen saturation, respiration rate, mental stress level, and blood pressure using mobile front camera that can be accessed most in real life. Face recognition was performed in real-time using Blaze Face to acquire facial image data, and the forehead was designated as ROI (Region Of Interest) using feature points of the eyes, nose, and mouth, and ears. Representative values for each channel of the ROI were generated and aligned on the time axis to measure vital signs. The vital signs measurement method was based on Fourier transform, and noise was removed and filtered according to the desired vital signs to increase the accuracy of the measurement. To verify the results, vital signs measured using facial image data were compared with pulse oximeter contact sensor, and TI non-contact sensor. As a result of this work, the possibility of extracting a total of six vital signs (heart rate, heart rate variability, oxygen saturation, respiratory rate, stress, and blood pressure) was confirmed through facial images.

A Study on Real-Time Defect Detection Using Ultrasound Excited Thermography (초음파 서모그라피를 이용한 실시간 결함 검출에 대한 연구)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Jung, Hyun-Kyu;Kim, Seung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.211-219
    • /
    • 2006
  • The UET(ultrasound excited thermography) for the ,eat-time diagnostics of the object employs an infrared camera to image defects of the surface and subsurface which are locally heated using high-frequency putted ultrasonic excitation. The dissipation of high-power ultrasonic energy around the feces of the defects causes an increase In temperature. The defect's image appears as a hot spot (bright IR source) within a dark background field. The UET for nondestructive diagnostic and evaluation is based on the image analysis of the hot spot as a local response to ultrasonic excited heat deposition. In this paper the applicability of VET for fast imaging of defect is described. The ultrasonic energy is injected into the sample through a transducer in the vertical and horizontal directions respectively. The voltage applied to the transducer is measured by digital oscilloscope, and the waveform are compared. Measurements were performed on four kinds of materials: SUS fatigue crack specimen(thickness 14mm), PCB plate(1.8 mm), CFRP plate(3 mm) and Inconel 600 plate (1 mm). A high power ultrasonic energy with pulse durations of 250ms Is injected into the samples in the horizontal and vertical directions respectively The obtained experimental result reveals that the dissipation loss of the ultrasonic energy In the vertical injection is less than that in the horizontal direction. In the cafe or PCB, CFRP, the size of hot spot in the vortical injection if larger than that in horizontal direction. Duration time of the hot spot in the vertical direction is three times as long as that in the horizontal direction. In the case of Inconel 600 plate and SUS sample, the hot spot in the horizontal injection was detected faster than that in the vertical direction