• Title/Summary/Keyword: Camera flash

Search Result 52, Processing Time 0.02 seconds

Slow Sync Image Synthesis from Short Exposure Flash Smartphone Images (단노출 플래시 스마트폰 영상에서 저속 동조 영상 생성)

  • Lee, Jonghyeop;Cho, Sunghyun;Lee, Seungyong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.27 no.3
    • /
    • pp.1-11
    • /
    • 2021
  • Slow sync is a photography technique where a user takes an image with long exposure and a camera flash to enlighten the foreground and background. Unlike short exposure with flash and long exposure without flash, slow sync guarantees the bright foreground and background in the dim environment. However, taking a slow sync image with a smartphone is difficult because the smartphone camera has continuous and weak flash and can not turn on flash if the exposure time is long. This paper proposes a deep learning method that input is a short exposure flash image and output is a slow sync image. We present a deep learning network with a weight map for spatially varying enlightenment. We also propose a dataset that consists of smartphone short exposure flash images and slow sync images for supervised learning. We utilize the linearity of a RAW image to synthesize a slow sync image from short exposure flash and long exposure no-flash images. Experimental results show that our method trained with our dataset synthesizes slow sync images effectively.

Investigation of Instrument for Photostress Recovery Time Test in the Eye (눈의 광피로회복시간 검사를 위한 도구의 탐색)

  • Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.193-196
    • /
    • 2013
  • Purpose: This study was investigated to find out a useful instrument instead of direct ophthalmoscope for ocular photostress recovery time (PSRT) test. Methods: The PSRT test was performed using direct ophthalmoscope, trans illuminator, pen light, and camera flash for 48 subjects (average age 22.88 years, 96 eyes) who were corrected to 0.8~1.2 of visual acuity. Results: Each mean of PSRT measured by direct ophthalmoscope, trans illuminator, pen light, and camera flash was $27.90{\pm}18.40$ sec, $23.73{\pm}12.99$ sec, $21.31{\pm}15.57$ sec, and $18.98{\pm}11.64$ sec, respectively. The difference of PSRT between the eyes corrected more than 1.0 and the other eyes corrected under 1.0 of visual acuity was not found significantly. And there was no difference between dominant eyes and nondominant eyes of PSRT. Conclusions: Though the nearest instrument to direct ophthalmoscope was trans illuminator, pen light and camera flash could be the useful instruments for PSRT test.

Development of Device Driver for Image Capture and Storage by Using VGA Camera Module Based on Windows CE (WINDOWS CE 기반 VGA 카메라 모듈의 영상 획득과 저장을 위한 디바이스 드라이버 개발)

  • Kim, Seung-Hwan;Ham, Woon-Chul;Lee, Jung-Hwan;Lee, Ju-Yun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.27-34
    • /
    • 2007
  • In this paper device driver for camera capture in hand held mobile system is implemented based on microsoft windows CE operating system. We also study the storage device driver based on the FAT fie system by using NAND flash memory as a storage device. We use the MBA2440 PDA board for implementing the hardware for image capture by using CMOS camera module producted by PixelPlus company. This camera module has VGA $640{\times}480$ pixel resolution. We also make application program which can be cooperated with the device driver for testing its performance, for example image capture speed and quality of captured image. We check that the application can be cooperated well not only with the device driver for camera capture but also with the device driver for FAT file system designed especially for the NAND flash memory.

The Characteristics of a Transient Liquefied Butane Spray using PDPA and High Speed Camera (PDPA와 고속카메라에 의한 액상부탄 간헐분무 특성 연구)

  • 윤준규;임종한;김종현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.466-474
    • /
    • 2004
  • The characteristics of liquefied butane spray are expected to be different from conventional diesel fuel spray, because a flash boiling spray is expected when the surround pressure is below the saturated vapor pressure of the butane(0.23MPa 98K). The axial velocities. radial velocities. and size distributions in butane sprays were measured with PDPA(Phase Doppler Particle Analyzer) system. Sprays were macroscopically observed by using the high speed camera in case that the surround pressure is 0.37MPa and 0.15MPa. respectively. Compared with the conventional spray. the reversed results were investigated when the surround pressure is below the saturated vapor pressure of the butane.

A Study on Flash Memory Management Techniques (플래시메모리의 관리 기법 연구)

  • Kim, Jeong-Joon;Chung, Sung-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.4
    • /
    • pp.143-148
    • /
    • 2017
  • Flash Memory which is light and strong external shock as storage of small electronics like smartphone, digital camera, car black box has been widely used. Since the operation speed of the read operation and the write operation are different from each other, and the flash memory has the feature that it is not possible to overwrite, the delete operation is added to solve these problems. Wear-leveling must also be considered, since the number of erase times of the flash memory is limited. Many studies have been conducted on the substitutional algorithms of flash memory based on these characteristics of recent flash memories. So, to solve the problem that has existing buffer replacement algorithm this thesis divide page into 6 groups and when proposed algorithm select victim page, it consider reference page frequency and page recency.

Applying In-Page Logging to SQLite DBMS (SQLite DBMS에 IPL 기법 응용)

  • Na, Gap-Joo;Kim, Sang-Woo;Kim, Jae-Myung;Lee, Sang-Won
    • Journal of KIISE:Databases
    • /
    • v.35 no.5
    • /
    • pp.400-410
    • /
    • 2008
  • Flash memory has been widely used in mobile devices, such as mobile phone and digital camera. Recently flash SSD(Solid State Disk), having same interface of the disk drive, is replacing the hard disk of some laptop computers. However, flash memory still cannot be considered as the storage of database systems. The FTL(Flash Translation Layer) of commercial flash SSD, making flash memory operate exactly same as a hard disk, shows poor performance on the workload of databases with many random overwrites. Recently In-Page Logging(IPL) approach was proposed to solve this problem. In this paper, we implement IPL approach on SQLite, a popular open source embedded DBMS, and evaluate its performance. It improves the performance by up to 30 factors for update queries.

Implementation of Reflection Removal Algorithm on Mobile Device (모바일 장치에서 반사 잔상 제거 알고리즘 구현)

  • Lee, YuKyong;Lee, Yong-Hwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.1
    • /
    • pp.108-112
    • /
    • 2021
  • Undesired reflection removal from an image captured through glass window is widely needed with the prevalence of camera. In this paper, we present and implement a reflection removal algorithm, which is specially designed for smart devices. Our implementation requires smart phone application to take two input pictures of the same target, one with flash light on and another with flash light off. Then, we find a flash spot in the picture, match the features to align the input pictures, transform the color space, and finally combine the pictures. As the result, we get a resulting image with removed reflection, achieving the visually pleasant.

Effect of Injection Pressure on the Flash Boiling Spray from Simple Orifice Nozzle (인젝터 압력이 단공노즐 감압비등 분무에 미치는 영향)

  • Lee, Hyunchang;Cha, Hyunwoo;Kang, Donghyeon
    • Journal of ILASS-Korea
    • /
    • v.27 no.1
    • /
    • pp.42-49
    • /
    • 2022
  • Flash boiling occurs in a couple of modern engineering systems and understanding its mechanism is important. In this experimental study, discharge coefficient of flash boiling spray from simple orifice nozzle was measured, and backlight imaging was acquired at injection pressure to 6.0 bar and temperature to 163℃ for the purpose. Pressurized water by pump was used for working fluid and was heated by electric heater and ejected through simple orifice nozzle diameter of 0.5 mm. High speed camera with long distance microscope was used for backlight imaging in two FoV having magnification of 3.3 and 0.64. The decrease of discharge coefficient according to degree of superheating and evolution of flash boiling spray imaged at various pressure and temperature were explained by the pressure field inside the injector.

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF