• Title/Summary/Keyword: Camera Lens

Search Result 644, Processing Time 0.02 seconds

Smartphone Fundus Photography in an Infant with Abusive Head Trauma (학대뇌손상 영아에서 스마트폰으로 촬영한 안저소견)

  • Kim, Yong Hyun;Choi, Shin Young;Lee, Ji Sook;Yoon, Soo Han;Chung, Seung Ah
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.11
    • /
    • pp.1313-1316
    • /
    • 2017
  • Purpose: To report fundus photography using a smartphone in an infant with abusive head trauma. Case summary: An 8-month-old male infant presented to the emergency room with decreased consciousness and epileptic seizures that the parents attributed to a fall from a chair. He had no external wounds or fractures to the skull or elsewhere. However, computerized tomography of the brain revealed an acute subdural hematoma in the right cranial convexity and diffuse cerebral edema, leading to a midline shift to the left and effacement of the right lateral ventricle and basal cistern. The attending neurosurgeon promptly administered a decompressive craniectomy. Immediately after the emergency surgery, a fundus examination revealed numerous multi-layered retinal hemorrhages in the posterior pole extending to the periphery in each eye. He also had white retinal ridges with cherry hemorrhages in both eyes. We acquired retinal photographs using the native camera of a smartphone in video mode. The photographer held the smartphone with one hand, facing the patient's eye at 15-20 cm, and held a 20 diopter condensing lens at 5 cm from the eye in the other hand. Our documentation using a smartphone led to a diagnosis of abusive head trauma and to obtain the criminal's confession, because the findings were specific for repetitive acceleration-deceleration forces to an infant's eye with a strong vitreoretinal attachment. Conclusions: This ophthalmic finding had a key role in the diagnosis of abusive head trauma. This case presented the diagnostic use of a smartphone for fundus photography in this important medicolegal case.

Development of a dual-mode energy-resolved neutron imaging detector: High spatial resolution and large field of view

  • Wenqin Yang;Jianrong Zhou;Jianqing Yang;Xingfen Jiang;Jinhao Tan;Lin Zhu;Xiaojuan Zhou;Yuanguang Xia;Li Yu;Xiuku Wang;Haiyun Teng;Jiajie Li;Yongxiang Qiu;Peixun Shen;Songlin Wang;Yadong Wei;Yushou Song;Jian Zhuang;Yubin Zhao;Junrong Zhang;Zhijia Sun;Yuanbo Chen
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2799-2805
    • /
    • 2024
  • Energy-resolved neutron imaging is an effective way to investigate the internal structure and residual stress of materials. Different sample sizes have varying requirements for the detector's imaging field of view (FOV) and spatial resolution. Therefore, a dual-mode energy-resolved neutron imaging detector was developed, which mainly consisted of a neutron scintillator screen, a mirror, imaging lenses, and a time-stamping optical fast camera. This detector could operate in a large FOV mode or a high spatial resolution mode. To evaluate the performance of the detector, the neutron wavelength spectra and the multiple spatial resolution tests were conducted at CSNS. The results demonstrated that the detector accurately measured the neutron wavelength spectra selected by a bandwidth chopper. The best spatial resolution was about 20 ㎛ in high spatial resolution mode after event reconstruction, and a FOV of 45.0 mm × 45.0 mm was obtained in large FOV mode. The feasibility was validated to change the spatial resolution and FOV by replacing the scintillator screen and adjusting the lens magnification.

Thermographic Assessment on Temperature Change of Eye Surface in Cataract Surgery Observation (백내장수술 안에서 열화상카메라를 이용한 안구표면 온도의 변화)

  • Park, Chang Won;An, Young-Ju;Kim, Hyojin
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.497-504
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the temperature changes of the ocular surface before and after cataract surgery using thermography of a thermal imaging camera. Methods : The study included 75 patients (75 eyes) aged from 50 to 79 years who underwent cataract surgery. In the past, those who underwent corneal-related surgery, wearing contact lens, disorder of tear secretion and taking medication for systemic disease were excluded from this study. The temperature changes of the eyeball surface were measured using a thermal imager (Cox CX series, Answer, Korea) following Tear Break Up Time (TBUT) test, Mcmonnies questionnaire and Schirmer's Test in real time, Results : While the temperature of preoperative ocular surface was $35.20{\pm}0.54^{\circ}C$ and that of postoperative temperature was $35.30{\pm}0.53^{\circ}C$, the difference was not significant. The temperature changes in the ocular surface were statistically significant at $-0.12{\pm}0.08{\Delta}$ ($^{\circ}C/sec$) before the surgery and $-0.18{\pm}0.07{\Delta}$ ($^{\circ}C/sec$) after the surgery. In comparison of the age groups, it was shown that the changes in the surface temperature before the surgery were from $-0.19{\pm}0.05{\Delta}$ ($^{\circ}C/sec$) to $-0.14{\pm}0.09{\Delta}$ ($^{\circ}C/sec$) in the 50s group, and from $-0.12{\pm}0.08{\Delta}$ ($^{\circ}C/sec$) to $-0.15{\pm}0.07{\Delta}$ ($^{\circ}C/sec$) in 60s group, and $-0.18{\pm}0.07{\Delta}$ ($^{\circ}C$) to $-0.12{\pm}0.08{\Delta}/sec$) in the 70s group, showing significant changes in the ocular surface temperature at all ages. Conclusion : Following the cataract surgery, all the indicators of dry eye syndrome were decreased, and eye surface temperature changes were significant. The thermography technique of the ocular surface would be expected to be useful for the evaluation of various dry eye syndromes because it is easy to evaluate dry eye syndrome noninvasively and can be quantified.

3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT (방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학)

  • Kim, Ju-Heon;Han, Sung-Mi;Song, Hyun-Ouk;Seo, Youn-Kyung;Moon, Young-Suk;Kim, Hong-Tae
    • Anatomy & Biological Anthropology
    • /
    • v.31 no.4
    • /
    • pp.133-142
    • /
    • 2018
  • 3D histology is a imaging system for the 3D structural information of cells or tissues. The synchrotron radiation propagation phase contrast micro-CT has been used in 3D imaging methods. However, the simple phase contrast micro-CT did not give sufficient micro-structural information when the specimen contains soft elements, as is the case with many biomedical tissue samples. The purpose of this study is to develop a new technique to enhance the phase contrast effect for soft tissue imaging. Experiments were performed at the imaging beam lines of Pohang Accelerator Laboratory (PAL). The biomedical tissue samples under frozen state was mounted on a computer-controlled precision stage and rotated in $0.18^{\circ}$ increments through $180^{\circ}$. An X-ray shadow of a specimen was converted into a visual image on the surface of a CdWO4 scintillator that was magnified using a microscopic objective lens(X5 or X20) before being captured with a digital CCD camera. 3-dimensional volume images of the specimen were obtained by applying a filtered back-projection algorithm to the projection images using a software package OCTOPUS. Surface reconstruction and volume segmentation and rendering were performed were performed using Amira software. In this study, We found that synchrotron phase contrast imaging of frozen tissue samples has higher contrast power for soft tissue than that of non-frozen samples. In conclusion, synchrotron radiation propagation phase contrast cryo-microCT imaging offers a promising tool for non-destructive high resolution 3D histology.