• 제목/요약/키워드: Cam-in-Cam

Search Result 2,319, Processing Time 0.036 seconds

A Study on the Development of CAD/CAM System for High Precision Cam Profile CNC Grinding Machine (고 정밀 캠 프로파일 CNC 연삭기용 CAD/CAM 시스템 개발에 관한 연구)

  • Lim, Sang-Heon;Jung, Jong-Yun;Lee, Choon-Man
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.5
    • /
    • pp.44-50
    • /
    • 2006
  • Cam mechanisms are one of the most popular devices for generating irregular motion and are widely used in many automatic equipments, such as textile machinery, internal combustion engines and other automatic devices. In order to obtain the positive motion of follower by rotating cam, its shape should be correctly designed and manufactured. In present paper, a CAD/CAM system is developed for shape design of disk cams using relative velocity method and NC code generation using the biarc curve interpolation. And, a disk cam is successfully manufactured by the developed CAD/CAM system. Thus, it is shown that the developed CAD/CAM system can be used for high precision cam profile CNC grinding machine.

DNA Rearrangement of TOL Plasmid in Pseudomonas putida PpGl Harbouring CAM Plasmid (CAM 플라스미드를 함유하는 Pseudomonas putida PpG1에서 TOL 플라스미드이 DNA 재배열)

  • 전효곤;조경연;고영희
    • Microbiology and Biotechnology Letters
    • /
    • v.18 no.4
    • /
    • pp.433-436
    • /
    • 1990
  • The TOL plasmid, pWWO, conjugally transferred from Pseudomonas putida mt-2 was dissociated into TOL* and TOL $\Delta$A in P. putidu PpGl carrying CAM plasmid. The TOL* was integrated into the CAM plasmid, and the resulting plasmid was designated as CAM::TOL*. The introduction of NAH plasmid, belonging to Inc P9 incompatibility group, into P. putida CSTBA carrying CAM::TOLt plasmid and TOL A plasmid did not affect m-toluate catabolism, but resulted in expelling the TOL $\Delta$ plasmid.

  • PDF

Optimum Design of Beating Cam for High Speed Rapier Loom (고속 래피어 직기용 바듸침 캠의 최적설계)

  • Kim, Jong-Su;Kim, Dae-Won
    • 연구논문집
    • /
    • s.28
    • /
    • pp.89-100
    • /
    • 1998
  • This paper deals with the design and analysis of a beating cam. The beating device of a high speed rapier loom, weaving fabric by completion of warp-weft patterns, is driven by double cam type on the same axis. As the double cam, coupled with two cams, performs the mutual conjugate motion, the double cam must be very preciously designed for smooth. For the shape design of a double cam, an instant velocity center method is proposed. This method can determine the cam profile from the contact conditions of the cam and roller follower and the velocity relationships at the instant velocity center. And the practical applicability was verified by developing “DISKCAM of a CAD program. As the results in this paper, the shapes of two cams, which are in the conjugate motion, are designed by instant velocity center method. We applied 8-order polynominals for the beating as displace¬ment curves for shape determination of double cams. The data of displacement, velocity, and acceleration of beating cam can be used adjust in accurate operation and to develope an advanced beating device.

  • PDF

Status and issues of CAD/CAM technology in Korea (국내 CAD/CAM 현황과 문제점)

  • 이종원;김태수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.437-442
    • /
    • 1986
  • Survey has been made to evaluate technological level and to identify research issues in CAD/CAM area. It is found out that major users of the CAD/CAM system are in mechanical and electronics as well as garment industries. Their experience shows that the impact of the CAD/CAM introduction is not yet noticeable in drafting man power and cost reduction. It is identified that the low penetration rate of CAD/CAM technology in industry is due to the lack of locally developed CAD/CAM softwares.

  • PDF

A Survey of Medical Students' Opinions about Complementary and Alternative Medicine

  • Song, Hywan
    • Korean Journal of Health Education and Promotion
    • /
    • v.20 no.4
    • /
    • pp.27-40
    • /
    • 2003
  • Objective: To determine second, third and fourth-year medical students' opinions and knowledge related to complementary and alternative medicine (CAM) in a school with no requirement or elective course on the subject. Study Design: A questionnaire was offered to second, third and fourth-year medical students of the Medical College of Kosin University from August 7th, through August 30th, 2003. Results: Most students had been exposed to CAM therapies, knew that the majority of the South Korean public was using CAM, believed that some CAM interventions were useful, and did not believe CAM therapies were a threat to public health. Only one fifth of the students(22.5%) disagreed that they had to have requirement or elective course on CAM in their curriculum. Most students had insufficient knowledge or understanding of the safety or lack of it for ten of the more common CAM modalities. Most respondents thought these interventions were useful, but would not refer a patient nor dissuade a patient from seeking out such interventions. Conclusion: Medical students in this school self-identified an interest about the clinical usefulness of ten CAM modalities, but did not have sufficient knowledge about the safety for ten of the more common CAM modalities. Including CAM topics in the medical school curriculum would better prepare physicians to respond to patient inquiries about CAM and thereby to fulfill their role as patient advocates.

A Study on the Cam Ring Deformation in a Balanced Type Vane Pump (유압 베인 펌프의 캠 링 변형에 관한 연구)

  • 한동철;조명래;양광식;박제승
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.206-211
    • /
    • 1998
  • This paper presents the deformation characteristics of cam ring in a balanced type vane pump. Cam ring is operated in the condition of high pressure. Therefore the local deformation of cam ring affects the characteristics of compression, vane motion and noise and vibration. We analyzed the deformation of cam ring in three types by using the finite element method. As results of analysis, deformed shape of cam ring and the effects of deformation on the compression are presented.

  • PDF

A Study on Programming Development Forming Design Automated of CAM for Coil Spring Forming Tool (코일 스프링 성형용 CAM의 성형설계자동화 프로그램개발)

  • Park, Chul-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.753-758
    • /
    • 2008
  • A CAM program for forming design Automated of CAM for Spring using car was developed in this study. This program was written in AUTO LISP on the AUTO CAD system with a personal. An approach to the system is based on the kinemateic of the object function. We make a determination of an cam programming. A CAM spline is continuous in displacement. velocity and acceleration. This program which can design Coil Spring shapes will successfully support CAN designing and manufacturing for Small & Medium companies.

Specific Targeting of Fluorescein Isothiocyanate with Ep-CAM Antibody(Specific targeting of FITC with Ep-CAM Antibody)

  • Lee, Young-Tae;Tae, Gun-Sik
    • Journal of Photoscience
    • /
    • v.10 no.3
    • /
    • pp.237-240
    • /
    • 2003
  • The tetradecameric peptide (K47-K60) near the NH$_2$-terminal region of epithelial-cell adhesion molecule (Ep-CAM) was chosen as antigenic site and a polyclonal antibody was generated, which could recognize Ep-CAM from the mouse colon tissue or the colon cancer cell, CT-26, in Western blot analysis. Then, the fluorescein isothiocyanate (FITC), a fluorescence dye, was conjugated with the affinity purified Ep-CAM antibody using thiocyanate and the amino groups of FITC and antibody, respectively. The molar ratio of FITC to antibody was estimated approximately 1.86 to 1.00 by measuring the optical densities at 492 nm and 280 nm. Ep-CAM antibody-FITC conjugate was then used for immunohistochemistry of the CT-26 cells. Judging from the shapes formed by fluorescence, the Ep-CAM antibody could delivered FITC to the surface of cells in which Ep-CAM was expressed. This result implies that Ep-CAM antibody could be also used for the tissue-specific delivery of the photosensitizer to the target protein via antigen-antibody interaction.

  • PDF

A Study on Numerical Method for Motion Analysis of Cylindrical Cam with Translate Follower (병진운동용 원통캠기구의 운동해석을 위한 수치해석법 연구)

  • 김상진;신중호;김대원;박세환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.719-722
    • /
    • 2002
  • Cylindrical cam mechanisms are used commonly in many automatic machinery. But the cylindrical cam is very difficult to design and manufacture the shape. The motion analysis of the cylindrical cam can check the accuracy between designed data and manufactured data of the cam shape and can reproduce without the cam design data. The motion analysis of the cylindrical cam consists of displacement analysis, velocity analysis and acceleration analysis. This paper performs the motion analysis of a cylindrical cam with translating follower by using a relative velocity method and a central difference method. The displacement is calculated by using the central difference method and the velocity is calculated by the relative velocity method. The relative velocity method is defined by the relative motion between follower and cam at a center of a follower roller. The central difference method is derived in the 3 dimensional space.

  • PDF

A Study on Stability for Traverse Cam of Twising Machine using Shape Design Method of Relative Velocity and Modified Displacement Curves (상대속도에 의한 형상설계법과 개선된 변위선도에 의한 연사기용 Traverse Cam의 안정성에 관한 연구)

  • Kim, Jong-Su;Yun, Ho-Eop
    • 연구논문집
    • /
    • s.31
    • /
    • pp.101-112
    • /
    • 2001
  • A Twisting machine is to twist yarns for improving yarn stiffness. After twisting yarns, the twisting machine is winding yarn at a bobbin. Traverse cam is main part of winding yarn part. In other to improve twisting machine performance and stability, improve traverse cam part. Original displacement curves of traverse cam has two problems. One is that displacement curve has a vertex point the other is that velocity curve is discontinue point. So that, in this paper proposes a modified displacement curves of traverse cam and new shape design method of the traverse cam using the relative velocity method[1]. The relative velocity method calculates the relative velocity of the follower versus the cam at a center of roller, and then determines a contact point by using the geometric relationship and the kinematical constraints. Finally, we present to compare two designed cam. One is designed using original displacement curves the other is using modified displacement curve.

  • PDF