• Title/Summary/Keyword: Caliper

Search Result 242, Processing Time 0.032 seconds

A Study on the Effect of Thermal Deformation and Color Changes during the Firing Processes of Porcelain Clay(I) (자기소지의 소성 과정 중 열변형과 색 변화에 관한 연구(I))

  • 김종태
    • Archives of design research
    • /
    • v.21
    • /
    • pp.99-106
    • /
    • 1997
  • There were the changes of shapes and color tones when the soil materials e.g. Blue-Porcelain, White-Porcelain, Bunchong, mixed A and B, mullite, Sanchong and Ongki - used by most domestic ceramic artists - were glazed at $ 950^{\circ}C,; 1200^{\circ}C,; 1250^{\circ}C,; 1280^{\circ}C,;1300^{\circ}C$ After the materials were dried out at 120t: in an electric oven, they were mixed with water, keeping the percentage of moisture content 25% and kneaded specimens which are hexahedron by $$ 250{\times}30{\times}8mm$$were produced and dried after calibrated at 200mm interval with a vernier caliper. After the materials were dried and glazed, they showed few shape-changes at $950^{\circ}C$ but began to changed at $1200^{\circ}C$,especially Bunchong and Ongki made rapid changes. In the case of color-change, White-Porcelain changed very little. The color of Blue-Porcelain, mixed A and B, Sanchong, Mullite changed to ]aune brilliant as temperature went up but Bunchong and Ongki changed to dark brown or dark chocolate under the same conditions. This study aims at suggestion of the basic data which minimize failure rates by recognizing the property of the materials on the basis of this study and regulating shape-change phenomena and sensitive changes of color when ceramic artists work.

  • PDF

A Study on the Measurements of Total Body Fat in Korean Women Worker (여성근로자(女性勤勞者)의 피하지방측정(皮下脂肪測定)에 의(衣)한 총지방량(總脂肪量))

  • Bin, Soon-Duk;Ryu, Tcheong-Kun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.6 no.1
    • /
    • pp.17-25
    • /
    • 1973
  • For purpose of understanding of women worker's nutritional status in Korea, the author had studied oil 668 workers who are working in textile industry, chemical industry, manufacture of electrical machinery and supplies, manufacture of rubber and transportation (bus-guider). Skin-fold caliper was applicated and measured five positions. As a results of this study the following conclusions were obtained; 1. The mean skin-fold thickness were; arm: $$9.08{\pm}3.40\;mm\;(7.23{\sim}10.50\;mm)$$ back: $$16.23{\pm}5.25\;mm\;(13.18{\sim}17.20\;mm)$$ waist : $$17.86{\pm}5.82\;mm\;(13.27{\sim}19.31\;mm)$$ abdomen : $$15.45{\pm}5.04\;mm\;(10.82{\sim}16.43\;mm)$$ knee: $$13.49{\pm}4.16\;mm\;(10.80{\sim}14.04\;mm)$$ The lowest mean skin-fold thickness by age was $12.26{\pm}3.50\;mm$ at 16 year-old and the highest mean skin-fold thickness was $14.57{\pm}5.55\;mm$ at 19 yesr-old respectively. 2. Fat amounts The lowest body fat weight was 10.77 kg at 16 year-old and the highest was 12.09kg at 19 year-old, respectively. The mean body fat weight was 11.76 kg. The lowest %Fat was 20.67% at 26 year-old, the highest was 23.89% at 18 year-old and the average was 22.76%, respectively. The mean FFW was 39.94 kg and the lowest was 37.91 kg at 17 year-old, the highest was 41.64 kg at 27 year-old. The ratio of fat weight and total body mass (FW/TBM) were 21.04% at 27 year-old 23.75% at 19 year-old and average was 22.75%, respectively. The ratio of fat free weight and total body mass (FFW/TBM) were 76.25% at 19 year-old and 78.96% at 27 year-old, respectively. The average was 77.25%. The ratio of fat weight and fat free weight (FW/FFW) were 27.31% at 27 year-old and 31.15% at 19 year-old. The average was 29.44%.

  • PDF

Long term results in the unilateral cleft lip repair by Mulliken's method (Mulliken 방법을 이용한 일측성 구순열의 장기 추적 결과)

  • Kim, Seok-Kwun;Moon, In-Sun;Lee, Chang-Ho;Heo, Jung;Kwon, Yong-Seok;Lee, Keun-Cheol
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.174-182
    • /
    • 2009
  • Purpose: The Mulliken's method is a one of the very excellent technique to correction of the unilateral cleft lip. It could decrease the need of additional operation and second operation by the early simultaneous correction of unilateral cleft lip and nasal deformity, at a time. Numerous procedures were advocated for the correction of nasal deformity, but with general dissatisfaction of the results, it became obvious that no one procedure is the ideal one. The authors have been operating on unilateral cleft lip by Mulliken's method and long term follow - up of postoperative result was evaluated. Methods: The authors have done long term follow - up of result in the 75 cases unilateral cleft lip patient, during 1 ~ 7 years. That was repaired by simultaneous correction of cleft lip and nasal deformity by Mulliken's method at the period from June, 1997 to December, 2007. The patients were unilateral complete cleft lip 39 cases, unilateral incomplete cleft lip 36 cases. In the severe complete cleft lip cases, lip adhesion operation was done before definite operation. The mean age of unilateral cleft lip operation was 3.2 months. Five anthropometric parameters, which were upper lip, cutaneous lip and vermilion mucosa height, nasal tip protrusion, columella length were measured by Sliding Vernier Caliper. The anthropometric analysis was performed preoperative and postoperative at 6 months, 3, 5 and 7 years and the results were com pared with those of age - matched, normal children. T - tests were used to analyze the differences between the measurements. Results: Long - term postoperative results were evaluated by anthropometrically. Most patients showed adequate growth of upper lip height, vermilion mucosa height and columella length. But nasal tip protrusion was relatively short compare with normal value. Incomplete cleft lip group was nearly normal growth results than complete cleft lip group. Conclusion: In conclusion, we could make harmonious Cupid's bow, natural philtrum and lip, appropriate nasal shape by Mulliken's method. But nasal tip protrusion was under the normal values on complete and incomplete group. And incomplete group was more good results than complete group. We have experienced repair of cleft lip by Mulliken's method with 75 cases of unilateral cleft lip patients and conclude that it was very useful and good method.

Discontinuity Analysis Using Well Log Methods from a Borehole-PABH1 in the Pungam Sedimentary Basin (풍암퇴적분지 내 시추공 PABH1에서 불연속면에 대한 물리검층방법의 적용)

  • 김영화;장승익;김중열;현혜자
    • The Journal of Engineering Geology
    • /
    • v.8 no.3
    • /
    • pp.261-273
    • /
    • 1998
  • Multiple well log analysis technique consisting of geophysical well log and geological core log has been made to analysis the discontinuities of a test borehole-PABH1 located in Pungam sedimentary basin, Sosok, Hongchon-gun, Kangwon Province. Well log methods consist of normal resistivity log, focussed log, single point resistance log, SP log, gamma log, natural gamma log as well as acoustic televiewer log and borehole television log. Core scanning technique was used as an aid for geological core log. The analysis was made by comparing firstly the televiewer and core discontinuities, and then the results from conventional geophysical log analysis were compared to those from core log and acoustic televiewer log. Fractures deduced from the acoustic televiewer log coincide well with discontinuities shown on the core and conventional geophysical logs. Particularly close coincidence could be observed between fractures derived from acoustic televiewer and conventional geophysical log analysis. It has been noted that the geophysical logs such as, caliper, resistivity, density and high resolution gamma gamma curves are effective in delineating the fractures. For example the ratio between density and resistivity (BRD/SHN) provides also an alternative indicator for discerning the fracture condition in the study area.

  • PDF

The Relationship of Two-Point Discrimination Threshold and the Number of Fungiform Papilla According to Anatomical Location of Tongue (해부학적 위치에 따른 혀의 촉각식별능의 차이와 심상유두 개수의 관계)

  • Kim, Kyun-Yo;Hur, Yun-Kyung;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.4
    • /
    • pp.295-303
    • /
    • 2008
  • The lingual branch of the trigeminal nerve transmitts general sensation from anterior two thirds of the tongue, also bearing within sheath fibers of chordal tympani branch of the facial nerve. Chorda tympani nerve carries special taste sensations from the anterior two thirds of the tongue and sub-serves the existing trigeminal pathway. Chorda tympani nerve and the lingual nerve innervate to fungiform papilla and distribution of fungiform papilla on tongue dorsum is variable according to anatomical location. The purpose of this report is to assess that the relationship of the number of fungiform papilla and the ability of two-point discrimination of tongu dorsum. Twenty-six healthy students(male:female=13:13) whose mean age was $30{\pm}3$ participated in our study. Two-point discrimination thresholds were measured to evaluate the spatial acuity of touch sensation. The measurement was carried out at the tip and posterolateral region of dorsal tongue. After two-point discrimination test, we took the pictures of their dorsal tongue dyed with methylene blue with digital camera. There were no significant differences between the number of fungiform papilla and the two-point discrimination threshold. But, we found that there were the intraregional and intersubject variations of spatial acuity of the tongue. During the test on the posterolateral region of the dorsal tongue, students appealed the difficulty of discrimination of one point and two point.

Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images (두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향)

  • Jeong Ho-Gul;Kim Kee-Deog;Park Hyok;Kim Dong-Ook;Jeong Haijo;Kim Hee-Joung;Yoo Sun Koo;Kim Yong Oock;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF

A FLUOROSCOPIC STUDY ON THE STABILITY OF SKIN REFERENCE POINTS DURING JAW OPENING AND CLOSING MOVEMENT (방사선 투시를 이용한 개폐구 운동에 따른 수직 고경 계측점의 안정성에 관한 연구)

  • Ahn, Hyung-Jun;Kim, Chang-Whe;Kim, Yung-Soo;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.516-530
    • /
    • 1999
  • The current clinical technique for occlusal vertical dimension recording is based on marking the skin reference points on the patient's face and measuring between these points using caliper-like device. And it is difficult to achieve reliable measurements by this technique because of movable soft tissue. The purpose of this study is to reveal the stability of skin reference points by comparing the relative movement between extra-oral skin reference points and intra-oral reference points using X-ray fluoroscope. 10 test subjects were divided into 2 groups : Group I (natural dentition) and Group II (denture-wearer whose vertical dimension was lost) and Group III consists of identical test subjects to Group II with their upper denture removed and record base inserted. Attaching the 3 mm diameter steel ball to nose tip, lower lip, chin and to existing denture (or record base), fluoroscopic examination and recording were taken during 2 jaw opening and closing movements. After subsequent digitization using personal computer, 1219 still pictures with 0.1 second interval were made. Using the 2 dimensional graphic software, measurements between reference points were executed. Dividing the entire jaw movement into 3 ranges (total, 1st half opening, 2nd half opening), rate of movement and relative movement between extra-oral and intra-oral reference points were calculated and statistically analyzed. The results of this study are as follows. 1 Within the same experimental group, no statistical difference was found in the stability of skin reference between lower lip point and chin point during total range of jaw opening and closing movement (p>.05) 2. In the first half range of jaw opening, statistical difference was found between Group I (natural dentition) and Group II (denture wearer) (p<.05) Group I has greater skin reference stability than Group II. 3. In the first half range of jaw opening, statistical difference was found between Group I and Group III (record base wearer) (p<.05). Group I has greater skin reference stability than Group III. 4. In the first half range of jaw opening, no statistical difference was found in the stability of skin reference between Group II and Group III (p>.05). 5. In the second half range of jaw opening, no statistical difference was found in the stability of skin reference between any experimental groups (p>.05). 6. In patients with their occlusal vertical dimension lost, employing other measuring references rather than skin is recommended because of low stability.

  • PDF

Comparing the efficiency of periodontal instrument sharpening using aluminum oxide stones with different levels of roughness (다양한 거칠기의 알루미늄 옥사이드(Al2O3) 연마석을 이용한 치주기구 날 세우기의 효율성 비교)

  • Kim, Yong-Gun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.131-137
    • /
    • 2014
  • Purpose: This study examined the efficiency and wear of periodontal instrument sharpening using aluminum oxide stones with different levels of roughness. Materials and Methods: Thirty new No. 9-10 Gracey curets were used in this study. All curets had become dull after scaling and root planing. After similar blunting, the instruments were divided randomly into three groups (240, 600, 800 grit) containing 10 curets each. The stones were applied correctly to the lateral surface of each curet to maintain the $70-80^{\circ}$ angle. After resharpening, sharpness of the curets was examined by an optical microscope. After 20, 40, 60, and 80 strokes, the wear was measured at 1 mm and 2 mm from the tip of the cutting edge using a digital caliper. The data was analyzed statistically using analysis of variance (ANOVA) with repeated measures, 2-way ANOVA, and a Fisher's exact test. Results: The degree of sharpness increased significantly (P < 0.001) as the number of sharpening strokes grew for all stones. A comparison of the degree of sharpness on the same number of strokes showed that the 240 grit group significantly excelled the other groups on 5 and 10 strokes, respectively (P < 0.001). The mean wear showed no statistically significant difference among the groups (P > 0.05). Conclusion: The efficiency of Gracey curet resharpening was enhanced with more coarse stones, though we should consider the wear of the instrument during resharpening.

Radiographic Evaluation of Small Intestinal Diameter in Small Breed Dogs (소형견에서 소장 직경의 방사선학적 평가)

  • Choi, Ho-Jung;Kim, Soo-Chan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.391-394
    • /
    • 2012
  • The purpose of the present study was to prove our empirical tendency of relatively high small intestinal diameter (SI) to fifth lumbar vertebral height (L5) ratio, which has been used in dogs. In this study, the ratio of SI/L5 was determined in small breed dogs weighing less than 5 kg. In addition, the effect of large volume of contrast media on the intestinal dilation was determined by performing upper gastrointestinal contrast study. Abdominal radiography and upper gastrointestinal series were performed in twelve healthy dogs weighing less than 5 kg. Small intestinal diameter (SI), fifth lumbar vertebral height (L5), and twelveth rib diameter were measured on abdominal radiographs. The range of values of SI/L5 is from 1.03 to 2.26 in plain radiography, and from 1.55 to 2.5 in contrast studies. Contrast agent significantly increased small intestinal diameter, and could be considered as mildly dilated intestinal model. Therefore, a value of 2.1 for SI/L5 is recommended as the upper limit of the normal range suggesting nonobstructive intestinal dilation.

In vitro comparison of measurement accuracy In pre-enlarged and enlarged canals with four apex locators (근관 성형 전후의 네 가지 전자근관장측정기의 측정 정확성의 비교)

  • Sung, Sang-Yup;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.371-377
    • /
    • 2006
  • The purposes of this study were to assess the accuracy of measurements in pre-enlarged canals with small instruments and to compare the accuracies, in enlarged canal, with small size instruments and instruments that match the actual canal diameter using Root ZX, Bingo1020, SmarPex, and e-Magic Finder. Ten extracted teeth were embedded in an alginate model made for testing apex locators. A size 10 file was placed into the root canal until the tip of the file reached the plane of the major diameter of the foramen under a dental operating microscope at the 25 x magnification. The measurement was done with digital caliper and defined as actual length. Electronic length measurement with a size 10 file in pre-enlarged canal was done by reading the index indicating Apex of each device to gain a definite value After completion of canal enlargement to a size 45 file, each difference between actual length and electric measurement value with a size 10 and 40 files in enlarged canal was recorded as L10 and L40. The one-way ANOVA and Scheffe's multiple range tests were computed for analyze the differences among the four apex locators in the same group. The Student's t-test between L10 and L40 of each locator was done. The accuracies of electronic measurements were significantly different among the 4 devices. The file size made no difference on the accuracy of electronic measurement in enlarged canal with same device. The e-Magic Finder was the most accurate device among the 4 apex locators used in this study.