• 제목/요약/키워드: Calibration plot

검색결과 55건 처리시간 0.027초

EPR Investigation on a Quantitative Analysis of Eu(II) and Eu(III) in LiCl/KCl Eutectic Molten Salt

  • Park, Yong-Joon;Kim, Tack-Jin;Cho, Young-Hwan;Jung, Yong-Ju;Im, Hee-Jung;Song, Kyu-Seok;Jee, Kwang-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권1호
    • /
    • pp.127-129
    • /
    • 2008
  • EPR spectroscopic technique was applied for a quantitative analysis of Eu(II) for a speciation of europium in a LiCl-KCl eutectic melt. By adopting the first absorption line of each isotopes (151Eu and 153Eu), a calibration plot was obtained. The calibration of the EPR intensity shows a good linearity according to the amount of Eu(II). The EPR intensity was identified to increase proportionally with a decrease of the attenuation parameter for EPR microwave power. The fluorescence technique was used qualitatively to find whether either of Eu(II) or Eu(III) ions exists in a molten salt sample. The ICP-AES technique was also adopted to determine the total concentration of europium in the sample, since EPR is only sensitive for detecting the Eu(II) ion. The extent of the reduction of Eu(III) in the LiCl-KCl eutectic melt at 723 K was determined by using this technique.

A Mixed-effects Height-Diameter Model for Pinus densiflora Trees in Gangwon Province, Korea

  • Lee, Young Jin;Coble, Dean W.;Pyo, Jung Kee;Kim, Sung Ho;Lee, Woo Kyun;Choi, Jung Kee
    • 한국산림과학회지
    • /
    • 제98권2호
    • /
    • pp.178-182
    • /
    • 2009
  • A new mixed-effects model was developed that predicts individual-tree total height for Pinus densiflora trees in Gangwon province as a function of individual-tree diameter (cm). The mixed-effects model contains two random-effects parameters. Maximum likelihood estimation was used to fit the model to 560 height-diameter observations of individual trees measured throughout Gwangwon province in 2007 as part of the National Forest Inventory Program in Korea. The new model is an improvement over fixed-effects models because it can be calibrated to a local area, such as an inventory plot or individual stand. The new model also appears to be an improvement over the Forest Resources Evaluation and Prediction Program for the ten calibration trees used in this study. An example is provided that describes how to estimate the random-effects parameters using ten calibration trees.

Imaging Plate에 기록된 전자회절자료의 해석 (Accurate Interpretation of Electron Diffraction Data Acquired by Imaging Plates)

  • 김영민;김윤중
    • Applied Microscopy
    • /
    • 제33권3호
    • /
    • pp.195-204
    • /
    • 2003
  • Imaging plate에 기록된 전자회절 자료의 면간 거리 분석과 상동정시 나타나는 오차 요인들을 고찰하고 실험적인 보정방법을 도출하였다. 각각의 회절방향에 대한 radial intensity distribution plot과 실험적으로 도출된 면간 거리 보정식에 의해 전자회절 자료의 디지털 이미지에서 면간 거리 측정오차는 약 0.5%로 낮아짐을 알 수 있었다. Al 표준시료를 이용하여 imaging plate에 기록된 전자회절 자료의 면간 거리 편차 경향을 분석한 후 [001] gibbsite 시편에 동일한 실험적 보정을 수행하여 120분간의 전자빔 조사로부터 형성된 여러 전이 상들에 대한 면간 거리 측정 및 상 동정을 보다 정밀히 수행할 수 있었다. 그 결과, gibbsite로부터 형성된 주요 전이상들은 ${\chi}$-알루미나, ${\gamma}$-알루미나, ${\sigma}$-알루미나로 구성됨을 명확하게 동정할 수 있었다.

ADVANTAGES OF USING ARTIFICIAL NEURAL NETWORKS CALIBRATION TECHNIQUES TO NEAR-INFRARED AGRICULTURAL DATA

  • Buchmann, Nils-Bo;Ian A.Cowe
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1032-1032
    • /
    • 2001
  • Artificial Neural Network (ANN) calibration techniques have been used commercially for agricultural applications since the mid-nineties. Global models, based on transmission data from 850 to 1050 nm, are used routinely to measure protein and moisture in wheat and barley and also moisture in triticale, rye, and oats. These models are currently used commercially in approx. 15 countries throughout the world. Results concerning earlier European ANN models are being published elsewhere. Some of the findings from that study will be discussed here. ANN models have also been developed for coarsely ground samples of compound feed and feed ingredients, again measured in transmission mode from 850 to 1050 nm. The performance of models for pig- and poultry feed will be discussed briefly. These models were developed from a very large data set (more than 20,000 records), and cover a very broad range of finished products. The prediction curves are linear over the entire range for protein, fat moisture, fibre, and starch (measured only on poultry feed), and accuracy is in line with the performance of smaller models based on Partial Least Squares (PLS). A simple bias adjustment is sufficient for calibration transfer across instruments. Recently, we have investigated the possible use of ANN for a different type of NIR spectrometer, based on reflectance data from 1100 to 2500 nm. In one study, based on data for protein, fat, and moisture measured on unground compound feed samples, dedicated ANN models for specific product classes (cattle feed, pig feed, broiler feed, and layers feed) gave moderately better Standard Errors of Prediction (SEP) compared to modified PLS (MPLS). However, if the four product classes were combined into one general calibration model, the performance of the ANN model deteriorated only slightly compared to the class-specific models, while the SEP values for the MPLS predictions doubled. Brix value in molasses is a measure of sugar content. Even with a huge dataset, PLS models were not sufficiently accurate for commercial use. In contrast an ANN model based on the same data improved the accuracy considerably and straightened out non-linearity in the prediction plot. The work of Mr. David Funk (GIPSA, U. S. Department of Agriculture) who has studied the influence of various types of spectral distortions on ANN- and PLS models, thereby providing comparative information on the robustness of these models towards instrument differences, will be discussed. This study was based on data from different classes of North American wheat measured in transmission from 850 to 1050 nm. The distortions studied included the effect of absorbance offset pathlength variation, presence of stray light bandwidth, and wavelength stretch and offset (either individually or combined). It was shown that a global ANN model was much less sensitive to most perturbations than class-specific GIPSA PLS calibrations. It is concluded that ANN models based on large data sets offer substantial advantages over PLS models with respect to accuracy, range of materials that can be handled by a single calibration, stability, transferability, and sensitivity to perturbations.

  • PDF

Development of a Chloroform Reference Material for the Proficiency Testing of Hazardous Compounds in Commercial Consumer Chemical Products Under the Consumer Chemical Products and Biocide Safety Management Act (K-BPR)

  • Lee, Sang Tak;Lee, Jae-ung;Kim, Joo-Hyon;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • 제10권4호
    • /
    • pp.112-116
    • /
    • 2019
  • In this study, a chloroform consumer chemical product (CCP) reference material (RM) is successfully developed, with potential to be used in the proficiency testing of hazardous compounds in CCPs for analysis and testing agencies. Validation experiments are rigorously conducted to evaluate whether the RM meets the requirements set by the ISO 13528 and ISO Guide 35, using a reliable GC/MS method for the analysis of chloroform. The obtained calibration plot linearity, limit of detection (LOD), and limit of quantitation (LOQ) are excellent. The developed RM meets the homogeneity and stability requirements; the between-unit (sbb) and within-unit (swb) standard deviations are less than 2.5%, and the stability is found to be guaranteed for 50 days.

Determination of Letrozole in formulation by a Validated RP-HPLC method

  • Ganesh, Mani;Bhagiyalakshm, Margandan;Vinoba, Mari;Jang, Hyun-Tae
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2010년도 춘계학술발표논문집 2부
    • /
    • pp.1230-1232
    • /
    • 2010
  • A simple, rapid and validated reverse d phase liquid chromatographic method has been developed for the determination of Letrozole (LZ) in pharmaceutical dosage. LZ was separated on ODS analytical column with a mixture of acetonitrile, water in the ratio 50:50 (v/v) as mobile phase at a flow rate of 1.0 mL /min. The effluent was monitored by UV detection at 265nm. Calibration plot was linear in the range of 160 to $240{\mu}g$/mL with the linear regression (r) = 0.999. The method was validated for recovery, precision, specificity.

  • PDF

흑연로 원자흡수분광광도법에 의한 뇨시료 중 흔적량 원소의 정량 (Determination of Trace Elements in Urine Samples by Graphite Furnace Atomic Absorption Spectrophotometry)

  • 최종문;최희선;박창준;김영상
    • 분석과학
    • /
    • 제7권4호
    • /
    • pp.555-561
    • /
    • 1994
  • A method was described for the graphite furnace atomic absorption spectrophotometric determination of trace cadmium, copper, chromium and lead in urine samples. The elements were directly determined without any other treatments. The ash temperature was intensively optimized to improve the large background by the removal of organic materials and alkali and alkali earth metals in urine samples. Two kinds of standard solutions were used to plot calibration curves. From the recovery data, it could be confirmed that the analytical results with the synthetic urine matrix similar to real urine were more accurate than with a deionized water matrix.

  • PDF

In-line Monitoring of an Oxide Ion in LiCI Molten Salt Using a YSZ Based Oxide Ion Selective Electrode

  • Cho, Young-Hwan;Jeon, Jong-Seon;Yeon, Jei-Won;Choi, In-Kyu;Kim, Won-Ho
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.415-419
    • /
    • 2004
  • The electrode potential characteristics of a YSZ based membrane metal oxide electrode have been studied in molten LiCL at $700^{\circ}C$ by the potentiometric method. The electrode exhibited a good potential response to log[$O^2$] and data reproducibility. The calibration plot (potential vs. log[$O^2$] was found to be linear, obeying the Nernst equation. The electrode potential showed a good reversibility corresponding to increase/decrease of the oxide ion present in the molten LiCl. The physical and chemical durability appeared to be sound after several repeated uses, resulting in reproducible results. However, "the proposed electrode" failed when metallic Li was present in the melt.

Nomogram for screening the risk of developing metabolic syndrome using naïve Bayesian classifier

  • Minseok Shin;Jeayoung Lee
    • Communications for Statistical Applications and Methods
    • /
    • 제30권1호
    • /
    • pp.21-35
    • /
    • 2023
  • Metabolic syndrome is a serious disease that can eventually lead to various complications, such as stroke and cardiovascular disease. In this study, we aimed to identify the risk factors related to metabolic syndrome for its prevention and recognition and propose a nomogram that visualizes and predicts the probability of the incidence of metabolic syndrome. We conducted an analysis using data from the Korea National Health and Nutrition Survey (KNHANES VII) and identified 10 risk factors affecting metabolic syndrome by using the Rao-Scott chi-squared test, considering the characteristics of the complex sample. A naïve Bayesian classifier was used to build a nomogram for metabolic syndrome. We then predicted the incidence of metabolic syndrome using the nomogram. Finally, we verified the nomogram using a receiver operating characteristic curve and a calibration plot.

NEAR-INFRARED STUDIES ON STRUCTURE-PROPERTIES RELATIONSHIP IN HIGH DENSITY AND LOW DENSITY POLYETHYLENE

  • Sato, Harumi;Simoyama, Masahiko;Kamiya, Taeko;Amari, Trou;Sasic, Slobodan;Ninomiya, Toshio;Siesler, Heinz-W.;Ozaki, Yukihiro
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1281-1281
    • /
    • 2001
  • Near-infrared (NIR) spectra have bean measured for high-density (HDPE), linear low-density (LLDPE), and low-density (LDPE) polyethylene in pellet or thin films. The obtained spectra have been analyzed by conventional spectroscopic analysis methods and chemometrics. By using the second derivative, principal component analysis (PCA), and two-dimensional (2D) correlation analysis, we could separate many overlapped bands in the NIR. It was found that the intensities of some bands are sensitive to density and crystallinity of PE. This may be the first time that such bands in the NIR region have ever been discussed. Correlations of such marker bands among the NIR spectra have also been investigated. This sort of investigation is very important not only for further understanding of vibration spectra of various of PE but also for quality control of PE by vibrational spectroscopy. Figure 1 (a) and (b) shows a NIR reflectance spectrum of one of the LLDPE samples and that of PE, respectively. Figure 2 shows a PC weight loadings plot of factor 1 for a score plot of PCA for the 16 kinds of LLDPE and PE based upon their 51 NIR spectra in the 1100-1900 nm region. The PC loadings plot separates the bands due to the $CH_3$ groups and those arising form the $CH_2$ groups, allowing one to make band assignments. The 2D correlation analysis is also powerful in band enhancement, and the band assignments based upon PCA are in good agreement with those by the 2D correlation analysis.(Figure omitted). We have made a calibration model, which predicts the density of LLDPE by use of partial least square (PLS) regression. From the loadings plot of regression coefficients for the model , we suggest that the band at 1542, 1728, and 1764 nm very sensitive to the changes in density and crystalinity.

  • PDF