• 제목/요약/키워드: Calibration curve

검색결과 698건 처리시간 0.027초

최적화 기법을 이용한 임하호유역 대표 CN값 추정 (Regionalization of CN values at Imha Watershed with SCE-UA)

  • 전지홍;김태동;최동혁
    • 한국농공학회논문집
    • /
    • 제53권5호
    • /
    • pp.9-16
    • /
    • 2011
  • Curve Numbers (CN) for the combination of land use and hydrologic soil group were regionalized at Imha Watershed using Long-term Hydrologic Impact Assessment (L-THIA) coupled with SCE-UA. The L-THIA was calibrated during 1991-2000 and validated during 2001-2007 using monthly observed direct runoff data. The Nash-Sutcliffe (NS) coefficients for calibration and validation were 0.91 and 0.93, respectively, and showed high model efficiency. Based on the criteria of model calibration, both calibration and validation represented 'very good' fit with observe data. The spatial distribution of direct surface runoff by L-THIA represented runoff from Thiessen pologen at Subi and Sukbo rain gage station much higher than other area due to the combination of poor hydrologic condition (hydrologic soil C and D group) and locality heavy rainfall. As a results of hydrologic condition and treatment for land use type based on calibrated CNs, forest is recommended to be hydrologically modelled dived into deciduous, coniferous, and mixed forest due to the hydrological difference. The CNs for forest and upland showed the poor hydrologic condition. The steep slope of forest and alpine agricultural field make high runoff rate which is the poor hydrologic condition because CN method can not consider field slope. L-THIA linded with SCE-UA could generated a regionalized CNs for land use type with minimized time and effort, and maximized model's accuracy.

L-THIA를 이용한 서울특별시 유출량 공간적 분석: 2011년 7월 27일 강우를 중심으로 (Analysis of Spatical Distribution of Surface Runoff in Seoul City using L-THIA: Case Study on Event at July 27, 2011)

  • 전지홍
    • 한국농공학회논문집
    • /
    • 제53권6호
    • /
    • pp.171-183
    • /
    • 2011
  • Temporal and spatical surface runoff by heavy rainfall during 25~28 July, 2011 causing urban flooding at Seoul were analyzed using Long-Term Hydrologic Impact Assessment (L-THIA). L-THIA was calibrated for 1988~1997 and validated for 1998~2007 using monthly observed data at Hangangseoul watershed which covers 90 % of Seoul city. As a results of calibration and validation of L-THIA at Hangangseoul watershed, Nash-Sutcliffe coefficients were 0.99 for calibration and 0.99 for validation. The simulated values were good agreement with observed data and both calibrated and validated levels were "very good" based on calibration criteria. The calibrated curve number (CN) values of residential and other urban area represented 87 % and 93 % of impervious area, respectively, which were maximum percentage of impervious area. As a result of L-THIA application at Seoul city during 25~28 July, 2011, most of rainfall (54 %, 287.49 mm) and surface runoff (65 %, 247.32) were generated at 27 July, 2011 and a significant amount of rainfall and surface runoff were occurred at southeastern Seoul city. As a result of bi-hourly spatial and temporal analysis during 27 July, 2011, surface runoff during 2:00~4:00 and 8:00~10:00 were much higher than those during other times and surface runoff located at Seocho-gu during 6:00~8:00 represented maximum value with maximum rainfall intensity which caused landslide from Umyun mountain.

황색종 담배중 전알카로이드와 환원당 분석에 대한 불확도 측정 (Uncertainty of Total Alkaloids and Reducing Sugar Determination in Flue-cured Tobacco)

  • 백순옥;장기철;이운철;한상빈
    • 한국연초학회지
    • /
    • 제23권1호
    • /
    • pp.45-52
    • /
    • 2001
  • This study was carried out to evaluate the uncertainty in the analysis of total alkaloids and reducing sugar content in flue-cured tobacco. The sources of uncertainty associated with the analysis of total alkaloids and reducing sugar were the weighing of sample, the preparation of extracting solution, the addition of extracting solution into the sample, the preparation of standard solution, the precision of calibration curve for standard solution, the reproducibility of analysis, and the determination of water content in tobacco, etc. For the calculating uncertainties, Type A of uncertainty was evaluated by the statistical analysis of a series of observation, and Type B by the information based on supplier’s catalogue and/or certificated of calibration. It was shown that the main source of uncertainty was caused by the calibration curve of standard solution, the reproducibility of analysis, the volume measurement of 1$m\ell$, and the purity of nicotine reference material in the preparation of standard solution. The uncertainty in the addition of extracting solution, the sample weighing, the volume measurement of 100$m\ell$, and the determination of water content of tobacco contributed relatively little to the overall uncertainty. The expanded uncertainty of total alkaloids and reducing sugar in flue-cured tobacco at 95% level of confidence was $\pm$0.12% and $\pm$0.54%, respectively.

  • PDF

Radioactivity analysis for EPS waste using organic solvents

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3717-3722
    • /
    • 2021
  • In this study, the recovery rates of the dissolution method for radioactivity analysis of expandable polystyrene (EPS) with a liquid scintillation counter (LSC) using tetrahydrofuran (THF), toluene, and acetone as solvents were estimated. The detection efficiency calibration curve for each solvent was derived. Two methods-the volumetric ratio method and the quenching agent method-were used to prepare quench source sets, and calibration curves were derived by linking the data from the two quench source sets. The R2 value of the calibration curve for THF was found to be 0.984. The relationship between the mass of dissolved EPS and the quench level was estimated: the quench level increased as the mass of dissolved EPS increased. Premix and postmix dissolution methods were tested. The recovery rates using THF with the premix method were 84.9 ± 0.9% and 96.5 ± 1.5% for 3H and 14C, respectively. Furthermore, the stability of the recovery rate over time when using THF was evaluated. The dissolution method with the premixed solution exhibited a more stable recovery rate over time. The dissolution methods were found to be applicable for analysis using LSC, and THF was found to be the most suitable solvent for the proposed method.

Wiggle Matching for Radiocarbon Dating Korean Artifacts with Biannual Samples

  • Park, Won-Kyu;Nam, Tae-Kwang;Park, Jung-Hun;Hong, Wan
    • 한국가구학회지
    • /
    • 제20권6호
    • /
    • pp.605-611
    • /
    • 2009
  • This paper reports the application of radiocarbon wiggle matching for Korean wooden artifacts such as furniture and Buddhist statues for precise dating. Ten biannual samples of 20 years (AD 1249-1268) for AMS (accelerator mass spectrometry) radiocarbon measurements were prepared from a board of the pedestal for Buddhist statue at Jeongsusa (temple) in Kangwhado, Korea, which was dendrochronologically dated. The average 95.4% confidence interval of radiocarbon dating without wiggle matching was 123 year. When wiggle matching technique was applied, it became 37 year, 3.3 times smaller than that without wiggle matching. The results indicated that wiggle matching technique using the calibration curve for northern hemisphere (IntCal04: International radiocarbon calibration curve announced in 2004) can produce precise dates for Korean wooden artifacts which possess as much as 20 tree rings.

  • PDF

Determination of Sulfur-containing Drugs by Gas Chromatography with Flame Photometric Detector

  • Kim, Kyoung-Ho;Cho, Yung-Hyun;Park, Man-Ki;Lee, Wang-Kyu
    • Archives of Pharmacal Research
    • /
    • 제6권2호
    • /
    • pp.103-108
    • /
    • 1983
  • Such sulfur-containing drugs as chlorpromazine, sulfonamides and thiazides were determined by gas chromatography with flame photometric detector (FPD) and flame ionization detector (FID). 0.6% QF-1 or 3% SE-30 on Chromosorb WAWDMCS were found suitable for drugs listed above. In the experimental conditions given maximum response the FPD response and the response ratio of FPD increased with the number of sulfur atom per molecule. It was possible to obtain a linear calibration curve from $10^{-9}$ / mole to $2{\times}10^{-8}$ / mole and to analyze variety of sulfur drugs by the calibration curve of one sulfur standard.

  • PDF

비혼탁도 법을 이용한 나노 콜로이드 입자의 크기 결정 (Determination of Sizes of Nano-Particles by Specific Turbidimetry)

  • 임경희
    • 한국응용과학기술학회지
    • /
    • 제25권1호
    • /
    • pp.107-114
    • /
    • 2008
  • In this article a reliable and rapid method based on specific turbidimetry is proposed for the determination of sizes of nanoparticles. Conventionally in specific turbidimetry specific turbidities for a colloidal dispersion are measured as a function of light wavelength, and compared to theoretical values calculated from Mie scattering theory for presumed particle sizes. In contrast specific turbidity at a fixed wavelength is measured in the proposed method, and particle sizes are determined from the prepared calibration curve. The calibration curve is a plot of specific turbidity vs particle size and in this case the specific turbidities are measured for a couple of samples of known sizes.

가스크로마토그라피-염광광도검출기를 이용한 지방산의 신속간편한 정량 (A Rapid and Convenient Method for the Determination of Fatty Acid by Gas Chromatography-Flame Photometric Detector)

  • 조영현;박만기;이숙연
    • 약학회지
    • /
    • 제29권5호
    • /
    • pp.227-233
    • /
    • 1985
  • A new method of determination of fatty acid using gas chromatography-flame photometric detector (GC-FPD) is described. Fatty acid was methylthiomethyl-esterified with methylthiomethy chloride in 1,8-diazabicyclo [5,4,0]-undec-7-ene catalyst and its concentration measured by GC-FPD with 3%OV-1 or 3% FS-1 column. The FPD responses of thirteen fatty acid methylthiomethyl esters were examined and were proportional to the concentration of the esters without regard to their chemical structures. Consequently it was possible to determine various fatty acid using one standard calibration curve by GC-FPD. We could rapidly and conveniently determine varous fatty acids using one standard calibration curve by GC-FPD. We could rapidly and conveniently determine 13 fatty acids in Ginseng Radix alba by this method.

  • PDF

Energy Calibration for Neutron Capture Resonance of Natural Sm by Using 46-MeV Electron Linear Accelerator

  • Lee, Jae-Hong;Lee, Sam-Yol
    • 한국방사선학회논문지
    • /
    • 제1권2호
    • /
    • pp.31-35
    • /
    • 2007
  • Energy calibration is important to identify accurate neutron capture resonance energy in the neutron TOF (Time-of-Flight) experiment. In present study, the accurate neutron capture resonance energies of natural Sm were measured by using a 46-MeV electron linear accelerator (linac) at the Research Reactor Institute, Kyoto University(KURRI). The BGO spectrometer were adopted for measurement the prompt capture gamma-ray of the sample. To obtain energy calibration curve, resonance energy of a gold sample used as standard resonance energy Mughabghab's data (From neutron resonance parameters data). Previous data (by Mughabghab) of natural Sm sample have been compared with the present result.

  • PDF

Measurement Uncertainty of Nicotine in Environmental Tobacco Smoke (ETS)

  • Lee, Jeong-Il;Lee, Cheol Min;Shim, In-Keun;Kim, Seong-Mi;Lee, Woo-Seok;Kim, Yoon-Shin
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권8호
    • /
    • pp.2394-2398
    • /
    • 2013
  • Nicotine is the main component of environmental tobacco smoke, and its presence in indoor air is widely used as a secondhand-smoke indicator. Environmental tobacco smoke is a major source of indoor air pollution, but sufficient investigation of the uncertainty of its measurement, which mirrors the reliability of nicotine measurement, has not been performed. We calculated the uncertainty of measurement of indoor air nicotine concentration at low, medium, and high concentrations of 11.3798, 10.1977, $98.3768{\mu}g/m^3$, respectively, and we employed the Guide to the Expression of Uncertainty in Measurements (GUM), proposed by the International Organization for Standardization (ISO). The factors considered in determining the uncertainty were uncertainty of the calibration curve (calibration curve and repeated measurements), desorption efficiency, extraction volume, and sampling airflow (accuracy and acceptable limits of flowmeter). The measurement uncertainty was highest at low concentrations; the expanded measurement uncertainty is $0.9435{\mu}g/m^3$ and is represented as a relative uncertainty of 63.38%. At medium and high (concentrations, the relative uncertainty was 13.1% and 9.1%, respectively. The uncertainty of the calibration curve was largest for low indoor nicotine concentrations. To increase reliability of measurement in assessing the effect of secondhand smoke, measures such as increasing the sample injection rate ($1{\mu}L$ or more), increasing sampling volume to increase collected nicotine, and using gas chromatography-mass spectrometry (GC/MS) or GC/MS/MS, which has a lower quantitation threshold, rather than gas chromatography with nitrogen phosphorous detector, should be considered.