• Title/Summary/Keyword: Calibration and measurement capability

Search Result 49, Processing Time 0.03 seconds

Real-Time Force Sensing in the Envelope of Zebrafish Egg during Micropipette Penetration

  • Yun, Seok;Kim, Deok-Ho;Kim, Byung-Kyu;Lee, Sang-Ho;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2451-2456
    • /
    • 2003
  • In biological cell manipulation, manual thrust or penetration of an injection pipette into an egg is currently performed by a skilled operator, relying only on visual feedback information. Massive load of various micro injection of either genes, fluid or cells in the postgenomic era calls a more reliable and automatic micro injection system that can test hundreds of genes or cell types at a single experiment. We initiated to study cellular force sensing in zebrafish eggs as the first step for the development of a more controllable micro injection system by any inexperienced operator. Zebrafish eggs at different developmental stages were collected and an integrated biomanipulation system was employed to measure cellular force during penetrating the egg envelope, the chorion. First of all, the biomanipulation system integrated with cellular force sensing instrument is implemented to measure the penetration force of cell membranes and characterize mechanical properties of zebrafish embryo cells. Furthermore, implementation of cellular force sensing system and calibration are presented. Finally, the cellular force sensing of penetrating cell membranes at each developmental stages was experimentally performed. The results demonstrated that the biomanipulation system with force sensing capability can measure cellular force at real-time while the injection operation is undergoing. The magnitude of the measured force was in the range of several hundreds of uN. The precise real-time measurement should provide the first step forwards for the development of an automatic and reliable injection system of various materials into biological cells.

  • PDF

A study on the image formation system variable and performance analysis for optimum design of high resolution SAR (고해상도 SAR 최적 설계를 위한 영상형성 시스템 변수 및 성능분석에 관한 연구)

  • Kwak, Jun-Young;Jeong, Dae-Gwon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.1
    • /
    • pp.49-60
    • /
    • 2012
  • Synthetic aperture radar (SAR) has been employed in various fields due to its capability to generate high resolution images regardless of weather and visibility. This paper presents a performance analysis on the image formation of high resolution SAR according to various slant range distance and synthetic aperture lengths using a range migration algorithm simulator. Although the visual performance on the SAR image is more accurate, a numeric analysis resulted in a comparable measurement. More specifically, raw data were generated for an ideal point target upon imaging geometries and design parameters such as slant range distance and synthetic aperture lengths. Finally, spatial resolution, peak to sidelobe ratio and integrated sidelobe ratio are drawn to provide SAR capabilities in the initial concept design, final in-flight calibration and validation stages.

A Biosensor for the Rapid Detection of the Fungicide Iprovalicarb Residuess (살균제 Iprovalicarb 잔류물의 신속한 검출을 위한 바이오센서)

  • Cho, Han-Keun;Kim, Woon-Ho;Kyung, Kee-Sung;Lee, Eun-Young
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.440-447
    • /
    • 2007
  • In this study, a biosensor was developed using an enzyme-linked immunosorbent assay (ELISA) to rapidly measure the fungicide iprovalicarb residues in agricultural products. The biosensor was designed to include micro-pumps and solenoid valves for fluid transport, a spectrophotometer cuvet as a reaction chamber, a photodiode with a light-emitting diode for optical density measurement, and a control microcomputer to implement assay. The rate of change in optical density of the cuvet was read as final signal output. Micro-pumps were evaluated to investigate their delivery capability, the highest values of the error and the coefficient of variation were 4.3% and 4.6% respectively. As the incubation period was reduced from 15 minutes to 11 minutes to shorten the total processing time, the sensor sensitivity was decreased as the antibody dilution ratio was reduced to a half. The maximum usable period of the coated cuvet was found to be two days with 1% error limit. To predict the concentration of the iprovalicarb residue in agricultural products, a linear calibration model was obtained with r-square values of 0.992 for potato and 0.985 for onion. In validation test for the samples of potatoes and onions against the high performance liquid chromatography, very high correlation values were obtained as 0.996 and 0.993 respectively. Using the cuvet immobilized with antigen, it took 21-minutes for the biosensor to complete the measuring process of the iprovalicarb residues.

Effects of variety, region and season on near infrared reflectance spectroscopic analysis of quality parameters in red wine grapes

  • Esler, Michael B.;Gishen, Mark;Francis, I.Leigh;Dambergs, Robert G.;Kambouris, Ambrosias;Cynkar, Wies U.;Boehm, David R.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1523-1523
    • /
    • 2001
  • The wine industry requires practical methods for objectively measuring the composition of both red wine grapes on the vine to determine optimal harvest time; and of freshly harvested grapes for efficient allocation to vinery process streams for particular red wine products, and to determine payment of contract grapegrowers. To be practical for industry application these methods must be rapid, inexpensive and accurate. In most cases this restricts the analyses available to measurement of TSS (total soluble solids, predominantly sugars) by refractometry and pH by electropotentiometry. These two parameters, however, do not provide a comprehensive compositional characterization for the purpose of winemaking. The concentration of anthocyanin pigment in red wine grapes is an accepted indicator of potential wine quality and price. However, routine analysis for total anthocyanins is not considered as a practical option by the wider wine industry because of the high cost and slow turnaround time of this multi-step wet chemical laboratory analysis. Recent work by this ${group}^{l,2}$ has established the capability of near infrared (NIR) spectroscopy to provide rapid, accurate and simultaneous measurement of total anthocyanins, TSS and pH in red wine grapes. The analyses may be carried out equally well using either research grade scanning spectrometers or much simpler reduced spectral range portable diode-array based instrumentation. We have recently expanded on this work by collecting thousands of red wine grape samples in Australia. The sample set spans two vintages (1999 and 2000), five distinct geographical winegrowing regions and three main red wine grape varieties used in Australia (Cabernet Sauvignon, Shiraz and Merlot). Homogenized grape samples were scanned in diffuse reflectance mode on a FOSE NIR Systems6500 spectrometer and subject to laboratory analysis by the traditional methods for total anthocyanins, TSS and pH. We report here an analysis of the correlations between the NIR spectra and the laboratory data using standard chemometric algorithms within The Unscrambler software package. In particular, various subsets of the total data set are considered in turn to elucidate the effects of vintage, geographical area and grape variety on the measurement of grape composition by NIR spectroscopy. The relative ability of discrete calibrations to predict within and across these differences is considered. The results are then used to propose an optimal calibration strategy for red wine grape analysis.

  • PDF

Reliability Evaluation of Fiber Optic Sensors Exposed to Cyclic Thermal Load (주기적인 반복 열하중에 노출된 광섬유 센서의 신뢰성 평가)

  • Kim, Heon-Young;Kang, Donghoon;Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.225-230
    • /
    • 2016
  • Fiber Bragg grating (FBG) sensors are currently the most prevalent sensors because of their unique advantages such as ease of multiplexing and capability of performing absolute measurements. They are applied to various structures for structural health monitoring (SHM). The signal characteristics of FBG sensors under thermal loading should be investigated to enhance the reliability of these sensors, because they are exposed to certain cyclic thermal loads due to temperature changes resulting from change of seasons, when they are applied to structures for SHM. In this study, tests on specimens are conducted in a thermal chamber with temperature changes from -$20^{\circ}C$ to $60^{\circ}C$ for 300 cycles. For the specimens, two types of base materials and adhesives that are normally used in the manufacture of packaged FBG sensors are selected. From the test results, it is confirmed that the FBG sensors undergo some degree of compressive strain under cyclic thermal load; this can lead to measurement errors. Hence, a pre-calibration is necessary before applying these sensors to structures for long-term SHM.

Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology (환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정)

  • Kang, Suman;Im, Inchul;Lee, Jaeseung;Jang, Eunsung;Lee, Mihyeon;Kwon, Kyungtae;Kim, Changtae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression device is a device by using the Compton scattering reaction and suppress the Compton continuum portion of the spectrum, so can be made more clear analysis of gamma ray peak in the Compton continuum region. Measurements above background occurs or, radioactivity counts of radioactivity concentration value of $^{40}K$ nuclides $^{137}Cs$ and natural radioactivity artificial radioactivity detected from the surface soil sample, unwanted non-target analysis and interference peak who dotted line you know the calibration of the measurement energy is allowed to apply the (Compton suppression) non-suppressed spectrum inhibition spectrum and (Compton Unsuppression) the background to the measured value of the activity concentration value of the standard-ray source is detected relative to the peak of By measuring according to the different distances cause $^{137}Cs$, and comparative analysis of the Monte Carlo simulation, in order to obtain a detection capability for efficient, looking at the Compton inhibitor, as the CSF value increases with increase in the distance, more It was found that the background due to Compton continuum of the measured spectrum suppression mode Compton unrestrained mode can know that the Compton suppression many were made, using a $^{137}Cs$ is reduced.

Comparisons of Water Behavior and Moisture Content between Rockwools and Coir used in Soilless Culture (무토양재배용 암면과 코이어 배지의 수분 이동 및 함수율 특성 비교)

  • Shin, Jong Hwa;Son, Jung Eek
    • Journal of Bio-Environment Control
    • /
    • v.24 no.1
    • /
    • pp.39-44
    • /
    • 2015
  • To improve crop productivity with optimal water management in soilless culture, the information of physical characteristics of the root medium including water behavior should be required. The objectives of this study were to analyze the physical characteristics including hydraulic properties of the root media commercially used and to analyze the relationships between actual moisture content and measured one by FDR sensor. The weight of the medium was measured by load cell for calculating the actual moisture content. The accuracy of the moisture content measured by FDR sensor was obtained by comparing with the actual one. The water holding capacity of the coir was lower than those of the rockwool due to the features of large and rough particles of the coir. The moisture content measured by FDR sensor showed large difference from the actual moisture contents measured by loadcell, indicating that the calibration of FDR sensor is needed before starting measurement. The optimum range of moisture content for irrigation control was narrow in the coir than the rockwool due to the lower water holding capacity and rehydration capability of the coir. The results of this study can be useful in establishing adequate irrigation strategies in the soilless culture.

Development of a Wideband Power Sensor for the Measurement of Wireless Power (무선 주파수 전력 측정을 위한 광대역 전력 센서 개발)

  • Hwang, Mun-Su;Na, In-Ho;Gu, Ja-Gyeong;Lim, Jong-Sik;Ahn, Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3600-3607
    • /
    • 2009
  • This paper describes the development of a power sensor for wireless signal over the ultra wideband range of 300~3800MHz with the detecting range of 150mW~150W. The proposed power sensor fundamentally has the function of not only detecting wireless power, but recognizing frequency and measuring VSWR. The development of the power sensor is completed through the design of dual directional coupler, design of power detector block which produces DC data using the corresponding RF input power level, and establishment of collecting the exact calibration data. The dual directional coupler has the operating frequency of 300~3800MHz with the 0.085dB of insertion loss, and directivity of 30dB at least at 3800MHz. The developed power sensor has the capability of power sensing with less than 0.25dB of resolution as well as measuring VSWR of 1.17~1.96 under the practical operating situation of very high power up to 150W at 300~3800MHz.

DISEASE DIAGNOSED AND DESCRIBED BY NIRS

  • Tsenkova, Roumiana N.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1031-1031
    • /
    • 2001
  • The mammary gland is made up of remarkably sensitive tissue, which has the capability of producing a large volume of secretion, milk, under normal or healthy conditions. When bacteria enter the gland and establish an infection (mastitis), inflammation is initiated accompanied by an influx of white cells from the blood stream, by altered secretory function, and changes in the volume and composition of secretion. Cell numbers in milk are closely associated with inflammation and udder health. These somatic cell counts (SCC) are accepted as the international standard measurement of milk quality in dairy and for mastitis diagnosis. NIR Spectra of unhomogenized composite milk samples from 14 cows (healthy and mastitic), 7days after parturition and during the next 30 days of lactation were measured. Different multivariate analysis techniques were used to diagnose the disease at very early stage and determine how the spectral properties of milk vary with its composition and animal health. PLS model for prediction of somatic cell count (SCC) based on NIR milk spectra was made. The best accuracy of determination for the 1100-2500nm range was found using smoothed absorbance data and 10 PLS factors. The standard error of prediction for independent validation set of samples was 0.382, correlation coefficient 0.854 and the variation coefficient 7.63%. It has been found that SCC determination by NIR milk spectra was indirect and based on the related changes in milk composition. From the spectral changes, we learned that when mastitis occurred, the most significant factors that simultaneously influenced milk spectra were alteration of milk proteins and changes in ionic concentration of milk. It was consistent with the results we obtained further when applied 2DCOS. Two-dimensional correlation analysis of NIR milk spectra was done to assess the changes in milk composition, which occur when somatic cell count (SCC) levels vary. The synchronous correlation map revealed that when SCC increases, protein levels increase while water and lactose levels decrease. Results from the analysis of the asynchronous plot indicated that changes in water and fat absorptions occur before other milk components. In addition, the technique was used to assess the changes in milk during a period when SCC levels do not vary appreciably. Results indicated that milk components are in equilibrium and no appreciable change in a given component was seen with respect to another. This was found in both healthy and mastitic animals. However, milk components were found to vary with SCC content regardless of the range considered. This important finding demonstrates that 2-D correlation analysis may be used to track even subtle changes in milk composition in individual cows. To find out the right threshold for SCC when used for mastitis diagnosis at cow level, classification of milk samples was performed using soft independent modeling of class analogy (SIMCA) and different spectral data pretreatment. Two levels of SCC - 200 000 cells/$m\ell$ and 300 000 cells/$m\ell$, respectively, were set up and compared as thresholds to discriminate between healthy and mastitic cows. The best detection accuracy was found with 200 000 cells/$m\ell$ as threshold for mastitis and smoothed absorbance data: - 98% of the milk samples in the calibration set and 87% of the samples in the independent test set were correctly classified. When the spectral information was studied it was found that the successful mastitis diagnosis was based on reviling the spectral changes related to the corresponding changes in milk composition. NIRS combined with different ways of spectral data ruining can provide faster and nondestructive alternative to current methods for mastitis diagnosis and a new inside into disease understanding at molecular level.

  • PDF