• Title/Summary/Keyword: Calibration Test

Search Result 1,065, Processing Time 0.024 seconds

Field Campaigns and test results for Absolute Radiometric Calibration (Absolute Radiometric Calibration을 위한 Field Campaign과 시험결과)

  • Lee, Seon-Gu;Kim, Yong-Seung
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.213-219
    • /
    • 2006
  • Korea Aerospace Research Institute(KARI) performed field campaigns for absolute radiometric calibration with overpassing of satellite Orbview-3 on Cal/ Val site in Goheung and Daejeon. The performed Cal/Val method is the reflectance-based of vicarious calibration methods. We collected ground-based and meteology data such as temperature, surface pressure and reflectance of targets, and radiosonde data only collected on Goheung. Data collected on each field served as input to radiative transfer codes to generate a top-of-atmosphere(TOA) radiance. Derived TOA is compared with DN of overpassing satellite Orbview-3 to calculate calibration coefficient of gain and offset. Also, This study proposed a proper method to prepare absolute radiometic calibration of KOMPSAT-2 by using experience of Field campaign.

  • PDF

An Experimental Study on Density Tool Calibration (밀도검층 검출기 보정에 관한 기초 연구)

  • Kim, Yeonghwa;Kim, Kiju;Lim, Heontae;Kim, Jihoon;Kong, Nam-Young
    • Journal of the Korean Geophysical Society
    • /
    • v.7 no.4
    • /
    • pp.237-245
    • /
    • 2004
  • Series of basic experiments for current density calibration by user process and for density calibration using geophysical model borehole were made. We tried to find the sonde response characteristics for current calibration using water and aluminium field jig, and using the equation of half life of 137Cs source. The result of calibration test made in a geophysical model borehole built first in Korea shows a perfect linear calibration equation. By adopting this calibration equation we could estimate the limitation as well as possibility of current density calibration by user process.

  • PDF

Optimal Calibration Interval Analysis Method through the Goodness of Fit Test of Measurement Reliability Models based on Maintenance Data (정비 데이터 기반 측정신뢰성 모델 적합성 검정에 의한 최적 교정주기 분석 기법)

  • Cha, Yun-bae;Kim, Boo-il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.178-180
    • /
    • 2016
  • TMDE(Test Measurement and Diagnostic Equipment) which is using in the military weapon system should perform the periodic calibration to maintain a measurement reliability during the life cycle, organizations are faced with increasing pressures to minimize costs while improving the reliability of test equipment. Previous studies suggest that reliability models are determined by considering simple size and characteristics of equipment, however an applying single Model may not be fit well maintenance data of many kinds of TMDEs. This paper presents that recommending an optimal calibration interval through the goodness of fit test with verifying statistical significance level among the several intervals which are computed with using major reliability models. According to the result of applying the actual proposed of calibration interval analysis method for various types of equipment, reliabilities are maintained for the end of calibration intervals.

  • PDF

Site Calibration for the Wind Turbine Performance Evaluation (풍력발전기 성능실증을 위한 단지교정 방법)

  • Nam, Yoon-Su;Yoo, Neung-Soo;Lee, Jung-Wan
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.49-57
    • /
    • 2002
  • The accurate wind speed information at the hub height of a wind turbine is very essential to the exact estimation of the wind turbine power performance testing. Several methods on the site calibration, which is a technique to estimate the wind speed at the wind turbine's hub height based on the measured wind data using a reference meteorological mast, are introduced. A site calibration result and the wind resource assessment for the Taekwanryung test site are presented using a one-month wind data from a reference meteorological mast and a temporal mast installed at the site of wind turbine. From this analysis, it turns out that the current location of the reference meteorological mast is wrongly determined, and the self-developed codes for the site calibration are working properly. Besides, an analysis on the uncertainty allocation for the wind speed correction using site calibration is performed.

  • PDF

A Study on Calibration Signal for Test of The Partial Discharge Measurement (부분방전 측정 시험을 위한 기준신호에 관한 연구)

  • Lee, Yong-Sung;Lee, Kyoung-Yong;Choi, Yong-Sung;Lee, Chang-Su;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.110-111
    • /
    • 2004
  • 본 논문은 부분방전 검출 시험 전에 수행하는 Calibration 신호 주입 및 검출 방법에 대한 연구이다. 사용된 시료는 지중케이블의 절연층으로 사용되는 XLPE 시트와 XLPE케이블이다. 실험방법은 50kV 내전압기(750-2CTS, Hipotronics)로부터 공급된 Calibration 신호를 Lemke (LDP-5, LDIC), 오실로스코프 (TDS-3012, Tektronix)와 주파수 분석기 (8563E, HP)를 사용하여 측정하였다. 시험에 사용된 센서로는 자체 제작한 박전극센서, UHF 센서 그리고 Lemke UHF 센서를 사용하였다. 위 방법을 통해 신호의 형태와 인가 전하량에 따른 Calibration 파형과 전하량 변화를 비교하였다. 실험결과 Calibration 신호 주입시 시험 환경 및 센서에 따라 Calibration 신호와 주입방법의 차이가 발생하였다.

  • PDF

Development of the automatic calibration system for industrial resistance thermometers at low temperatures (산업용 저항 온도계의 저온 자동 비교 교정 시스템 개발)

  • Yang, In-Seok;Song, Chang-Ho;Kang, Kee-Hoon;Kim, Yong-Gyoo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.429-436
    • /
    • 2008
  • A system is designed and fabricated for the automatic low temperature calibration by comparison of industrial resistance thermometers. The cryostat is suitable for the calibration of four capsule type thermometers and four long stem thermometers. By the automatic temperature control of the cryostat, we could calibrate thermometers from $-200^{\circ}C$ to $0^{\circ}C$ for ${\sim}15$ hours by one fill of liquid nitrogen in the test run of the system. The uncertainty of the calibration for industrial platinum resistance thermometers using the automatic system is about 30mK with a 95.% confidence interval.

The Detection of Calibration Signal for Test of the Partial Discharge Measurement (부분방전 측정 시험을 위한 기준 신호 검출)

  • Lee, Yong-Sung;Lee, Kyoung-Yong;Choi, Yong-Sung;Lee, Chang-Su;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.316-318
    • /
    • 2004
  • 본 논문은 부분방전검출 시험 전에 수행하는 Calibration 신호 주입 및 검출 방법에 대한 연구이다. 사용된 시료는 활선상의 배전용 XLPE 케이블이다. 실험방법은 50kV 내전압기 (750-2CTS, Hipotronics)로부터 공급된 Calibration 신호를 Lemke (LDP-5, LDIC), 오실로스코프 (TDS-3012, Tektronix)와 주파수 분석기 (8563E, HP)를 사용하여 측정하였다. 마지막으로 시험에 사용된 센서는 안테나 특성의 UHF 센서와 고주파 특성의 HFCT 센서이다. 실험결과, Calibration 신호 주입 시 시험 환경 및 센서에 따라 Calibration 신호와 주입방법의 차이가 발생하였다. 따라서 신호의 형태와 인가 전하량에 따른 Calibration 파형과 전하량 변화를 알 수 있었다.

  • PDF

The Study of Circuit Model Parameter Generation Using Device Simulation (소자 시뮬레이션을 이용한 Circuit Model Parameter 생성에 대한 연구)

  • 이흥주
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.177-182
    • /
    • 2003
  • In the case of the flash memory, various kinds of transistors and the wide range of operation voltage are necessary to achieve the read/write operations. Therefore, the characteristics of transistors are measured in the silicon for the circuit design, and the test vehicle run must be processed. In this study, an efficient design flow is suggested using TCAD tools. The test vehicle is replaced with well-calibrated TCAD simulation. First, the calibration methodology is introduced and tested for flash memory device. The calibration errors are less than 5% of a full chip operation, which is accepted by the designers. The results of the calibration were used to predict I-V curves and model parameter of the various transistors for the design of flash device.

  • PDF

CALIBRATION OF VECTOR MAGNETOGRAMS BY SOLAR FLARE TELESCOPE OF BOAO

  • MOON YONG-JAE;PARK YOUNG DEUK;YUN HONG SIK
    • Journal of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.65-73
    • /
    • 1999
  • In this study we present a new improved nonlinear calibration method for vector magnetograms made by the Solar Flare Telescope of BOAO. To identify Fe I 6302.5 line, we have scanned monochromatic images of the line integrated over filter passband, changing the location of the central transmission wavelength of a Lyot filter. Then we obtained a filter-convolved line profile, which is in good agreement with spectral atlas data provided by the Sacramento Peak Solar Observatory. The line profile has been used to derive calibration coefficients of longitudinal and transverse fields, employing the conventional line slope method under the weak field approximation. Our improved nonlinear calibration method has also been used to calculate theoretical Stokes polarization signals with various angles of inclination of magnetic fields. For its numerical test, we have compared input magnetic fields with the calibrated ones, which have been derived from the new improved non-linear method and the conventional method respectively. The numerical test shows that the calibrated fields obtained from the improved method are consistent with the input fields, but not with those from the conventional method. Finally, we applied our new improved method to a dipole model which characterizes a typical field configuration of a single, round sunspot. It is noted that the conventional method remarkably underestimates the transverse field component near the inner penumbra.

  • PDF

Intercomparison of Light Oil Flow Standard System for the Reliability of Measurement Accuracy (경질유 유량표준장치의 신뢰도 검증을 위한 측정정확도 비교)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.9
    • /
    • pp.712-719
    • /
    • 2008
  • Light Oil Flow Standard System(LOFSS), as a national oil flow standard system, in Korea Research Institute of Standards and Science(KRISS) was developed for oil flowmeter calibration, and the expanded uncertainty of flow quantity determination was estimated within 0.04 %. In order to improve the reliability of the LOFSS measurement, a proficiency test was carried out in the flow range of 20 and $240\;m^3/h$ (Reynolds number $20,000{\sim}900,000$). A turbine flowmeter was used as a transfer package in round robin test. The water flow standard system of KRISS, the pipe prover of the national calibration and test organization and the master meter calibrator of the turbine flowmeter supplier, which used the different working fluid respectively, were compared with the turbine flowmeter measurement. The maximum difference of measurement was 0.15 % between the LOFSS and the pipe prover. The En numbers of the each system measurement were evaluated at the same Reynolds number. It was found that the En numbers were less than 1 in the comparison, which means the procedures of the uncertainty estimation of the each calibrators were reasonable and reliable.