• Title/Summary/Keyword: Calibration Procedure

Search Result 401, Processing Time 0.026 seconds

Calibration of Car-Following Models Using a Dual Genetic Algorithm with Central Composite Design (중심합성계획법 기반 이중유전자알고리즘을 활용한 차량추종모형 정산방법론 개발)

  • Bae, Bumjoon;Lim, Hyeonsup;So, Jaehyun (Jason)
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.2
    • /
    • pp.29-43
    • /
    • 2019
  • The calibration of microscopic traffic simulation models has received much attention in the simulation field. Although no standard has been established for it, a genetic algorithm (GA) has been widely employed in recent literature because of its high efficiency to find solutions in such optimization problems. However, the performance still falls short in simulation analyses to support fast decision making. This paper proposes a new calibration procedure using a dual GA and central composite design (CCD) in order to improve the efficiency. The calibration exercise goes through three major sequential steps: (1) experimental design using CCD for a quadratic response surface model (RSM) estimation, (2) 1st GA procedure using the RSM with CCD to find a near-optimal initial population for a next step, and (3) 2nd GA procedure to find a final solution. The proposed method was applied in calibrating the Gipps car-following model with respect to maximizing the likelihood of a spacing distribution between a lead and following vehicle. In order to evaluate the performance of the proposed method, a conventional calibration approach using a single GA was compared under both simulated and real vehicle trajectory data. It was found that the proposed approach enhances the optimization speed by starting to search from an initial population that is closer to the optimum than that of the other approach. This result implies the proposed approach has benefits for a large-scale traffic network simulation analysis. This method can be extended to other optimization tasks using GA in transportation studies.

Boresight Calibration Comparison Using Geoid Models (지오이드 모델에 따른 Boresight 검정 비교)

  • So, Jae Kyeong;Park, Young Su;Won, Jae Ho;Yun, Hee Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.3
    • /
    • pp.291-297
    • /
    • 2016
  • Direct georeferencing has become widespread in the field of digital aerial photogrammetry; as a result, the boresight calibration has become an essential component of the procedure to calculating exterior orientation parameters of aerial photographs accurately. During this procedure, a reference is used for the height of the geoid model, and the calibration results can appear different depending on the geoid model. The exterior orientation parameters calculated through direct georeferencing during boresight calibration may have varied values according to the corresponding geoid model. With that in mind, the effects of the geoid model on the boresight calibration were analyzed through three different cases. The geoid models used in the experiments were EGM96, EGM08, and KNGeoid14, and, through boresight calibration, the datum shift and boresight angle for each model was computed. After calculating the exterior orientation of each case, the GCP (Ground Control Point) was verified using the DPW (Digital Photogrammetry Workstation). In each case, results in the boresight calibration acquired through the geoid model demonstrated a difference in the Z datum, the exterior orientation heights Z, and the rotation Ω and Φ. After utilizing the DPW in each case and comparing it to the GCP, the difference in accuracy in accordance with the geoid model was found to be within 3cm, and it was concluded that the geoid model did not have a significant impact on boresight calibration.

Determination of Identifiable Parameters and Selection of Optimum Postures for Calibrating Hexa Slide Manipulators

  • Park, Jong-Hyuck;Kim, Sung-Gaun;Rauf, Abdul;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2737-2742
    • /
    • 2003
  • Kinematic calibration enhances absolute accuracy by compensating for the fabrication tolerances and installation errors. Effectiveness of calibration procedures depends greatly on the measurements performed. While the Cartesian postures are measured completely, all of the geometric parameters can be identified to their true values. With partial pose measurements, however, few geometric parameters may not be identifiable and effectiveness of the calibration results may vary significantly within the workspace. QR decomposition of the identification Jacobian matrix can reveal the non-identifiable parameters. Selecting postures for measurement is also an important issue for efficient calibration procedure. Typically, the condition number of the identification Jacobian is minimized to find optimum postures. This paper investigates identifiable parameters and optimum postures for four different calibration procedures - measuring postures completely with inverse kinematic residuals, measuring postures completely with forward kinematics residuals, measuring only the three position components, and restraining the mobility of the end-effector using a constraint link. The study is performed for a six degree-of-freedom fully parallel HexaSlide type paralle manipulator, HSM. Results verify that all parameters are identifiable with complete posture measurements. For the case of position measurements, one and for the case of constraint link, three parameters were found non-identifiable. Optimal postures showed the same trend of orienting themselves on the boundaries of the search space.

  • PDF

IMU calibration technique and laboratory test (관성측정장치의 오차계수 식별기법 및 실험)

  • 성상만;이달호;이장규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.664-667
    • /
    • 1996
  • This paper presents the error parameter estimation technique for IMU(Inertial Measurement Unit) which is core sensor of INS(Inertial Navigation System) and verifies it via laboratory test. Firstly the error characteristic of gyroscope and accelerometer which is contained in IMU is examined and the error modelling is executed. The error of IMU can be divided into deterministic and random part, and the deterministic error can be divided into static and dynamic part. This paper consider the random part as constant. Secondly the error parameter estimation technique and following procedure for laboratory test is explained. Thirdly according to the test procedure the IMU test for static error is executed using 2-axis rate table and estimation result is presented with discussion about its validity.

  • PDF

On line flatness calibration of engineering surfaces using minimum separation technique (최소거리법에 의한 온라인 편평도 측정시스템 개발)

  • ;M. BURDEKIN
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.11a
    • /
    • pp.105-109
    • /
    • 1991
  • A computer aided flatness calibration system has been developed. Rectangular grids based measurement procedure is proposed with closing error technique. giving advantages over conventional diagonal measurement procedures (‘Union Jack’). A new analysis technique has been developed for flatness evaluation called ‘ETT(Enclose Tilt technique)’, enabling minimum separation definition which is acknowledged as standard term for flatness definition. Practical assessment shows the performance of the developed system.

  • PDF

Pipe Flange Measurement System Using Draw-Wire Sensor (Draw-Wire센서를 이용한 파이프 플랜지 계측시스템)

  • 윤재웅;윤강섭;이수철
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.62-69
    • /
    • 2003
  • In most shipyards, the measurement of 3-dimensional relative position of pipes should be connected in the block depends on the manual operation. It results a very tedious and inefficient procedure, thus the proper measurement system is needed to improve productivity and accuracy. This paper describes the development of pipe measurement system including system concepts, measuring procedures, system calibration, and its accuracy and productivity. And also, the possibility and things to be improved for application in shipyard are discussed in this paper.

Non-therapeutic purposes in orthodontics and correction of tooth and jaw surgery for the recognition of some students on research (비 치료목적으로 시술되고 있는 치아교정과 양악수술에 대한 일부 대학생들의 인식도에 관한 연구)

  • Kang, Mi-Hyun;Lee, Eun-Sook;Lee, Cheon-Hee;Kim, Sun-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.6
    • /
    • pp.1232-1240
    • /
    • 2012
  • Objectives : In this study, the treatment method for some college students, due to the misuse of non-therapeutic molding technique non-therapeutic procedure is applied in orthodontics or jaw surgery and therapeutic purposes, such as to properly recognize and to investigate whether. Methods : In this study used, 4 questions, the questionnaire general characteristics (such as gender, major, whether the treatment experience and purpose) Orthodontic and knowledge about the jaw surgery (Corrective jaw surgery hope and reason, or jaw surgery benefits, side effects, etc.) 6 items, calibration and recognition jaw surgery on seven items 17 items was constructed. Results : Of the perception of the majors of the respondents according to the presence or absence of a non-therapeutic procedure for calibration or jaw surgery the correct way, and the purpose appeared to know roughly majors and all students majoring statistically significant (p<.001). The degree of recognition for non-therapeutic procedures according to the gender of the respondents' facial aesthetic improvement, and the most common reason, you want to make a non-therapeutic procedure, correction or contrast, I've found that looks supremacist influence on the non-therapeutic procedure or roughly know the correct way, and jaw surgery for the purpose that appeared to be statistically significant (p<.05). Conclusions : Non-therapeutic procedure for the interest and knowledge to promote oral health as well as esthetic improvements to the original non-therapeutic procedure for therapeutic purposes and how to deliver education and it is very important.

A Visual Calibration Scheme for Off-Line Programming of SCARA Robots (스카라 로봇의 오프라인 프로그래밍을 위한 시각정보 보정기법)

  • Park, Chang-Kyoo;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.1
    • /
    • pp.62-72
    • /
    • 1997
  • High flexibility and productivity using industrial robots are being achieved in manufacturing lines with off-line robot programmings. A good off-line programming system should have functions of robot modelling, trajectory planning, graphical teach-in, kinematic and dynamic simulations. Simulated results, however, can hardly be applied to on-line tasks until any calibration procedure is accompained. This paper proposes a visual calibration scheme in order to provide a calibration tool for our own off-line programming system of SCARA robots. The suggested scheme is based on the position-based visual servoings, and the perspective projection. The scheme requires only one camera as it uses saved kinematic data for three-dimensional visual calibration. Predicted images are generated and then compared with camera images for updating positions and orientations of objects. The scheme is simple and effective enough to be used in real time robot programming.

Color Calibration Method for Improvement of Reliability on Image Analysis of Rock (암석영상분석의 신뢰도 향상을 위한 컬러보정기법 연구)

  • 장윤섭;박형동
    • Tunnel and Underground Space
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • Recently, the use of image analysis methods and commercial equipments has been extensively increased in the field of rock engineering. However the problem of errors involved in the image acquisition and subsequent analysis procedure has been frequently neglected. In addition there has been few studies dealing with this problem. So proper color calibration method is needed to be developed for the objectivity and improvement of reliability on image analysis of rock. Color calibration method using standard color rendition chart was adopted on this study. Color calibration and error analysis were carried out for the image acquired from granite rock samples. As a result, comparison among other rock images and improvement of reliability on whole analysis were possible.

Study on the Identifiable Parameters and Optimum Postures for Calibrating Parallel Manipulators (병렬구조 로봇의 보정을 위한 보정 가능 변수 판별과 최적 자세 선정에 관한 연구)

  • Park, Jong-Hyuck;Kim, Sung-Gaun;Rauf, Abdul;Ryu, Je-Ha
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1476-1481
    • /
    • 2003
  • Kinematic calibration enhances absolute accuracy by compensating for the fabrication tolerances and installation errors. Effectiveness of calibration procedures depends greatly on the measurements performed. This paper investigates identifiable parameters and optimum postures for four different calibration procedures - measuring postures completely with inverse kinematic residuals, measuring postures completely with forward kinematics residuals, measuring only the three position components, and restraining the mobility of the end-effector using a constraint link. The study is performed for a six degree-of-freedom fully parallel HexaSlide type parallel manipulator, HSM. Results verify that all parameters are identifiable with complete posture measurements. For the case of position measurements, one and for the case of constraint link, three parameters were found non-identifiable. Selecting postures for measurement is also an important issue for efficient calibration procedure. Typically, the condition number of the identification Jacobian is minimized to find optimum postures. Optimal postures showed the same trend of orienting themselves on the boundaries of the search space.

  • PDF