• Title/Summary/Keyword: Calibration Interval

Search Result 97, Processing Time 0.026 seconds

Accuracy Analysis of Small-Mass Measurement System using Multiple Calibration Algorithm for Experiments in Space (다중보상 알고리즘을 활용한 우주실험용 소질량측정시스템의 정확도 향상 연구)

  • Lee, Jong-Won;Kim, Youn-Kyu;Lee, Joo-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.8
    • /
    • pp.99-106
    • /
    • 2021
  • Scientists at the International Space Station have been studying space life sciences to prepare for future manned space explorations, and require experimental specimen such as rodents for mass measurement. However, it is challenging to use mass measurement systems in space owing to the errors caused by factors such as mechanical-electronic noise. Therefore, to minimize the measurement errors, we propose a new algorithm called multiple calibration, which divides the mass range and calculates the sample weight by using the correction equation of each interval. We performed tests to evaluate and compare the performance of the proposed method to that of normal methods. As a result, the measurement accuracy improved by over two times using the multiple calibration method. Furthermore, we conducted mass measurements on various samples and confirmed that our method is valid for mass measurements.

Non-Destructive Prediction of Head Rice Ratios using NIR Spectra of Hulled Rice (정조 상태에서 백미에 대한 완전미율의 비파괴 예측)

  • Kwon, Young-Rip;Cho, Seung-Hyun;Lee, Jae-Heung;Seo, Kyoung-Won;Choi, Dong-Chil
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.3
    • /
    • pp.244-250
    • /
    • 2008
  • The purpose of this study was to measure fundamental data required for the prediction of milling ratios, and to develop regression models to predict the head rice ratio of milled rice using NIR spectra of hulled rice. A total of 81 rice samples used in this study were collected from Jeongeup, Jeonbuk province in 2006. NIR spectra were measured using one mode of measurement, reflection. The reflectance spectra were measured in the wavelength region of 400-2500 nm with an NIR spectrophotometer "NIRSystems 6500" (Foss, Silverspring, USA). Calibration equations were developed by the modified partial least squares (MPLS), partial least squares (PLS), and principal components regression (PCR). Math treatments were 1-4-4-1, 1-10-10-1, 2-4-4-1, and 2-10-10-1. The software used was WinISI (Infrasoft International, State College, USA). Automatic head rice production and quality checking system used was "SY2000-AHRPQCS" (Ssangyong, Korea). The calibration was made with the first derivative and the spectrum designated was in 8 nm interval. The determination coefficients of head rice ratios were 0.8353, 0.8416 and 0.5277 for the MPLS, PLS and PCR, respectively. Those obtained with 20 nm interval were 0.8144, 0.8354 and 0.6908 for the MPLS, PLS and PCR, respectively. The calibration was made with second derivative that spectrum designated was 8 nm in interval. The determination coefficients of head rice ratios were 0.7994, 0.8017 and 0.4473 for the MPLS, PLS and PCR, respectively. Those with 20 nm interval were 0.8004, 0.8493 and 0.6609 for the MPLS, PLS and PCR, respectively. These results indicate that the accuracy of determination coefficient for MPLS and PLS is higher than that of PCR.

Inverse Estimation of Viscoplastic Properties of Solder Alloy Using Moir$\acute{e}$ Interferometry and Computer Model Calibration (모아레 간섭계와 모델교정법을 이용한 솔더 합금의 점소성 물성치 역추정)

  • Gang, Jin-Hyuk;Lee, Bong-Hee;Joo, Jin-Won;Choi, Joo-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.1
    • /
    • pp.97-106
    • /
    • 2011
  • In this study, viscoplastic material properties of solder alloy which is used in the electronics packages are inversely estimated. A specimen is fabricated to this end, and an experiment is conducted to examine deformation by Moir$\acute{e}$ interferometry. As a result of the experiment, bending displacement of the specimen and shear strain of the solder are obtained. A viscoplastic finite element analysis procedure is established, and the material parameters are determined to match closely with the experiments. The uncertainties which include inherent experimental error and insufficient data of experiments are addressed by using the method of computer model calibration. As a result, material parameters are identified in the form of confidence interval, and the displacements and strains using these parameters are predicted in the form the prediction interval.

Luminance Correction for Stereo Images using Histogram Interval Calibration (히스토그램 구간 교정을 이용한 스테레오 영상의 휘도 보정)

  • Kim, Seaho;Kim, Hiseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.159-167
    • /
    • 2013
  • In stereo-view system, variations of target camera position or lighting conditions cause discrepancies on the luminance and chrominance components of stereo views. These discrepancies lead to inaccurate frame view prediction and low quality of 3 D video coding. In this paper, an efficient histogram interval calibration method is proposed for stereo-view coding, so as to compensate for the luminance component of target view. First the proposed method is analyzed by the histogram of the target image frame. Then, it divide two sections of histogram of that frame to correct the color discrepancies. Secondly, each section of the target frame is corrected the luminance component by identify the maximum matching region between the reference frame and the target frame. We have verified our proposed histogram matching method in comparison with the other color correction ones. Experimental results show that it can correct better luminance calibration results of PSNR(Peak Signal to Noise Ratio) and has less computation time.

In-situ Calibration of Membrane Type Dissolved Oxygen Sensor for CTD (CTD용 박막형 용존산소 센서의 현장 교정)

  • DONG-JIN KANG;YESEUL KIM
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.28 no.1
    • /
    • pp.41-50
    • /
    • 2023
  • Dissolved oxygen sensors have characteristics in which data drift occurs over time. Therefore, in-situ calibration of the dissolved oxygen sensor is essential to accurately measure the concentration of dissolved oxygen in seawater. In order to provide a method for in-situ calibration, appropriate number of samples for calibration, and laboratory calibration interval of the dissolved oxygen sensor, the dissolved oxygen sensor values were compared with the measured values by titration on a total of 133 samples from three different cruises in the Indian Ocean, Pacific Ocean, and East Sea over a period of about one year. As a result, it is preferable to calibrate the sensor value using the correlation of a straight line obtained by directly comparing the final concentration value given by the sensor and the measured value. For the accurate calibration, at least 30 samples must be used to enable in-situ calibration within an accuracy range of about 1%. In addition, it is recommended that a laboratory calibration should perform within 1 year for the membrane type dissolved oxygen sensor for CTD to achieve a performance of 70% or more.

Bootstrap Calibrated Confidence Bound for Variance Components Model (분산 성분 모형에 대한 붓스트랩 보정 신뢰구간)

  • Lee, Yong-Hee
    • The Korean Journal of Applied Statistics
    • /
    • v.19 no.3
    • /
    • pp.535-544
    • /
    • 2006
  • We consider use of Bootstrap calibration in the problem of setting a confidence interval for a linear combination of variance components. Based on the the modified large sample(MLS) method by Graybill and Wang(1980), Bootstrap Calibration is applied to improve the coverage probability of the MLS confidence bound when the experiment is balanced and coefficients of a linear combination are positive. Performance of the proposed confidence bound in small sample is investigated by simulation studies.

Evaluation of the Potential for the Adulteration Screening of Imported Hay by Near Infrared Reflectance Spectroscopy (근적외선분광법을 이용한 수입건초의 이물질 혼입판정 가능성 평가)

  • Park, Hyung-Soo;Lee, Hyo-Won;Kim, Ji-Hye;Lee, Sang-Hoon;Kim, Jong-Duck
    • Journal of Animal Environmental Science
    • /
    • v.20 no.4
    • /
    • pp.183-188
    • /
    • 2014
  • Near-infrared reflectance spectroscopy (NIRS) was used to study the potential of adulteration of imported forage. Hay samples were prepared two set ; calibration set and validation one. The former were mixed 12 sets from 100% to 50% with Yangcho (Chinese leymus, leymus chinensis Trin.) and the latter were adulterated with 6 set of 8% to 38% in 5% interval. Mixed materials with Yangcho were rice straw, reed and alfalfa. Stand error of prediction (SEP) in calibration equation for alfalfa, reed and rice straw were 0.97, 0.97 and 0.99 also 0.54, 0.86 and 1.26%. Multiple correlation coefficient ($R^2$) for alfalfa, reed and rice straw were 0.99, 0.97 and 0.99. SEP in the same samples were 1.88, 2.15 and 1.49, respectively.

A Measurement Method of Three-Dimensional Surface Morphology Based on Depth-from-Focus through Linear Magnification Calibration (선형배율보정을 통한 DFF 기반의 삼차원 형상 측정법)

  • Kim, Gyung-Bum;Shin, Young-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.9 s.174
    • /
    • pp.115-122
    • /
    • 2005
  • Errors resulting from magnification variations of a optical system are largely generated in three-dimensional shape measurements based on depth-from-focus. In the case of measuring the surface morphology of tiny objects based on DFF, images are acquired with a very small interval so that magnification changes can be minimized. However, the magnification variations are actually existed in the acquired images and so focus measures are wrongly or ambiguously extracted. In this paper, a methodology with linear magnification calibrations, based on DFF, is proposed to make more accurate measurement in surface morphology with high depth discontinuity, compared with previous ones. Several experiments show that the proposed method outperforms existing ones without magnification calibrations.

Wiggle Matching for Radiocarbon Dating Korean Artifacts with Biannual Samples

  • Park, Won-Kyu;Nam, Tae-Kwang;Park, Jung-Hun;Hong, Wan
    • Journal of the Korea Furniture Society
    • /
    • v.20 no.6
    • /
    • pp.605-611
    • /
    • 2009
  • This paper reports the application of radiocarbon wiggle matching for Korean wooden artifacts such as furniture and Buddhist statues for precise dating. Ten biannual samples of 20 years (AD 1249-1268) for AMS (accelerator mass spectrometry) radiocarbon measurements were prepared from a board of the pedestal for Buddhist statue at Jeongsusa (temple) in Kangwhado, Korea, which was dendrochronologically dated. The average 95.4% confidence interval of radiocarbon dating without wiggle matching was 123 year. When wiggle matching technique was applied, it became 37 year, 3.3 times smaller than that without wiggle matching. The results indicated that wiggle matching technique using the calibration curve for northern hemisphere (IntCal04: International radiocarbon calibration curve announced in 2004) can produce precise dates for Korean wooden artifacts which possess as much as 20 tree rings.

  • PDF

Development of Near Infrared Spectroscopy(NIRS) Equation of Crude Protein in Wheat Germplasm

  • Hyemyeong Yoon;Myung-Chul Lee;Yumi Choi;Myong-Jae Shin;Sejong Oh
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.08a
    • /
    • pp.100-100
    • /
    • 2020
  • Wheat is mainly composed of carbohydrate but it contains a moderate amount of protein, which gives a very useful characteristics to flour food such as the unique elasticity and stickiness of the dough. We developed a calibration equation for analyzing crude protein content using Near Infrared Spectroscopy to quick analyze the crude protein content of wheat germplasm stored in the National Agrobiodiversity Center, RDA, Korea. The 1,798 wheat germplasms were used to draw up the calibration formula. The crude protein's interval distribution of 1,798 wheat germplasms used for the calibration was 7.04-20.84%, the average content was 13.2%, and standard deviation was 2.6%. The germplasms distribution was composed of a suitable group for the preparation of the calibration formula because the content distribution was a normal, excluding the 13.0-15.5% content section. In order to verify the applicability of the NIRS prediction model, we measured the crude protein content of the 300 wheat germplasms that were not used for the calibration using both Kjeldahl analysis and NIR spectrum. The analysis value calculated using each method were statistically processed, and the test results and statistical indicators of the predictive model were compared. As a result, The R2 value of the optimized NIRS prediction model was 0.997, and the Standard error of Calibration value(SEC) was 0.132, and slope value was 1.000. With prediction model selection, compared to Kjeldahl method, R2 values were 0.994(Kjeldahl), 0.998(NIRS), and the SEC value were 0.191 and 0.132, respectively, comparing the statistical indices of the forecast model. And slope value were 1.013, 1.000, respectively. The analysis of crude protein content by the NIRS predictive model developed by each statistical index showing similar figures is judged to show a high degree of correlation with the Kjeldahl analysis. The proven calibration equation will be used to measure the crude protein content of wheat germplasms held by the National Agrobiodiversity Center, and by dividing the wheat germplasms by their use according to the crude protein content, it will provide useful information to relevant researchers.

  • PDF