• Title/Summary/Keyword: Calibration Correction

검색결과 368건 처리시간 0.037초

A Typo Correction System Using Artificial Neural Networks for a Text-based Ornamental Fish Search Engine

  • Hyunhak Song;Sungyoon Cho;Wongi Jeon;Kyungwon Park;Jaedong Shim;Kiwon Kwon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권8호
    • /
    • pp.2278-2291
    • /
    • 2023
  • Imported ornamental fish should be quarantined because they can have dangerous diseases depending on their habitat. The quarantine requires a lot of time because quarantine officers collect various information on the imported ornamental fish. Inefficient quarantine processes reduce its work efficiency and accuracy. Also, long-time quarantine causes the death of environmentally sensitive ornamental fish and huge financial losses. To improve existing quarantine systems, information on ornamental fish was collected and structured, and a server was established to develop quarantine performance support software equipped with a text search engine. However, the long names of ornamental fish in general can cause many typos and time bottlenecks when we type search words for the target fish information. Therefore, we need a technique that can correct typos. Typical typo character calibration compares input text with all characters in a calibrated candidate text dictionary. However, this approach requires computational power proportional to the number of typos, resulting in slow processing time and low calibration accuracy performance. Therefore, to improve the calibration accuracy of characters, we propose a fusion system of simple Artificial Neural Network (ANN) models and character preprocessing methods that accelerate the process by minimizing the computation of the models. We also propose a typo character generation method used for training the ANN models. Simulation results show that the proposed typo character correction system is about 6 times faster than the conventional method and has 10% higher accuracy.

ASSESSING CALIBRATION ROBUSTNESS FOR INTACT FRUIT

  • Guthrie, John A.;Walsh, Kerry B.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1154-1154
    • /
    • 2001
  • Near infra-red (NIR) spectroscopy has been used for the non-invasive assessment of intact fruit for eating quality attributes such as total soluble solids (TSS) content. However, little information is available in the literature with respect to the robustness of such calibration models validated against independent populations (however, see Peiris et al. 1998 and Guthrie et al. 1998). Many studies report ‘prediction’ statistics in which the calibration and prediction sets are subsets of the same population (e. g. a three year calibration validated against a set from the same population, Peiris et al. 1998; calibration and validation subsets of the same initial population, Guthrie and Walsh 1997 and McGlone and Kawano 1998). In this study, a calibration was developed across 84 melon fruit (R$^2$= 0.86$^{\circ}$Brix, SECV = 0.38$^{\circ}$Brix), which predicted well on fruit excluded from the calibration set but taken from the same population (n = 24, SEP = 0.38$^{\circ}$Brix with 0.1$^{\circ}$Brix bias), relative to an independent group (same variety and farm but different harvest date) (n = 24, SEP= 0.66$^{\circ}$ Brix with 0.1$^{\circ}$Brix bias). Prediction on a different variety, different growing district and time was worse (n = 24, SEP = 1.2$^{\circ}$Brix with 0.9$^{\circ}$Brix bias). Using an ‘in-line’ unit based on a silicon diode array spectrometer, as described in Walsh et al. (2000), we collected spectra from fruit populations covering different varieties, growing districts and time. The calibration procedure was optimized in terms of spectral window, derivative function and scatter correction. Performance of a calibration across new populations of fruit (different varieties, growing districts and harvest date) is reported. Various calibration sample selection techniques (primarily based on Mahalanobis distances), were trialled to structure the calibration population to improve robustness of prediction on independent sets. Optimization of calibration population structure (using the ISI protocols of neighbourhood and global distances) resulted in the elimination of over 50% of the initial data set. The use of the ISI Local Calibration routine was also investigated.

  • PDF

센서 배열의 보정에 의한 자기 부상 시스템의 외란 제거 성능 개선 (Disturbance Elimination Performance Improvement of A Magnetic Levitation System by Array-Sensor Calibration)

  • 안명국;나승유
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.278-281
    • /
    • 2002
  • In this paper we propose a controller which has the capability of disturbance measurement calibration for Cds array sensors in a magnetic levitation system. Steady state error due to environment light condition or external disturbance is corrected constantly. The correction is made by the sensors to measure the ball position of the system without additional deployment of sensors.

  • PDF

수중탐상로봇시스템의 오차분석 및 보정 (Calibration of an underwater robotic inspection system)

  • 장종훈;김재열;김재희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.378-378
    • /
    • 2000
  • The permissible positioning error of the transducer used in reactor inspection must be within 10 mm. To implement the required precision it is necessary to manufacture all components affecting the positioning mechanism correctly and precisely. In addition, it is also necessary to handle error factors accurately. This paper describes the activities of the findings and corrections of the errors which were occurred in experiments. Those activities are; i) Categorization of error factors, ii) Cause analysis of errors, iii) Correction of errors founded in experiments by the analysis of laser induction type and by the validation of real measurement of horizontal, vertical baselines.

  • PDF

A parameter calibration method for PFC simulation: Development and a case study of limestone

  • Xu, Z.H.;Wang, W.Y.;Lin, P.;Xiong, Y.;Liu, Z.Y.;He, S.J.
    • Geomechanics and Engineering
    • /
    • 제22권1호
    • /
    • pp.97-108
    • /
    • 2020
  • The time-consuming and less objectivity are the main problems of conventional micromechanical parameters calibration method of Particle Flow Code simulations. Thus this study aims to address these two limitation of the conventional "trial-and-error" method. A new calibration method for the linear parallel bond model (CM-LPBM) is proposed. First, numerical simulations are conducted based on the results of the uniaxial compression tests on limestone. The macroscopic response of the numerical model agrees well with the results of the uniaxial compression tests. To reduce the number of the independent micromechanical parameters, numerical simulations are then carried out. Based on the results of the orthogonal experiments and the multi-factor variance analysis, main micromechanical parameters affecting the macro parameters of rocks are proposed. The macro-micro parameter functions are ultimately established using multiple linear regression, and the iteration correction formulas of the micromechanical parameters are obtained. To further verify the validity of the proposed method, a case study is carried out. The error between the macro mechanical response and the numerical results is less than 5%. Hence the calibration method, i.e., the CM-LPBM, is reliable for obtaining the micromechanical parameters quickly and accurately, providing reference for the calibration of micromechanical parameters.

Calibration Slope Adjustment for De-Striping KOMPSAT-1 EOC Images

  • Kang, C.H.;Park, D.J.;Ahn, S.I.;Koo, I.H.;Hyun, D.H.;Yang, H.M.;Kim, D.S.;Keum, J.H.;Choi, H.J.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1406-1408
    • /
    • 2003
  • KOMPSAT-1 (KOrea Multi-Purpose SATellite ? 1) EOC (Electro Optic Camera) raw images are radiometrically corrected on ground based on the characteristics of EOC. They consist of each CCD (Charge?Coupled Device) pixel’s calibration slope which was measured on ground, electrical gains which are applied to amplify for increasing output pixel counts. Currently, radio-metrically corrected EOC images with calibration slope have still shown defective features by residual stripes. So, it should be compensated by adjusting the calibration slope. In this paper, the adjustment of current calibration slope for de-striping EOC images is addressed and test results are shown.

  • PDF

Readout 회로의 구조를 반영한 적외선 영상의 불균일 보정기법 (Nonuniformity Correction Algorithm of Infrared Images Considering Readout Circuit Architecture)

  • 최은철;강문기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.429-430
    • /
    • 2007
  • FPA (Focal Plane Arrary)를 이용한 적외선 영상 획득 시스템에서 발생하는 주요 잡음 중 하나는 영상에 존재하는 공간적 고정 패턴 잡음(SFPN, Spatial Fixed Pattern Noise)이다. 이것이 발생하는 주된 요인은 배열을 이루고 있는 각 검출기들과, FPA 출력단에 있는 증폭기의 입출력 응답이 균일하지 않고, 시간이 흐름에 따라 그 응답특성이 변화하기 때문이다. 이 문제를 극복하기 위하여 일반적으로 교정기반 불균일 보정 방법(CBNUC, Calibration Based Nonuniformity Correction)과 장면기반 불균일 보정방법(SBNUC, Scene Based Nonuniformity Correction)이 사용된다. 본 논문은 CBNUC를 사용하는 시스템의 FPA 출력단 회로에 구성된 복수의 증폭기에 존재하는 이득의 차이 및 잡음에 의한 불균일을 보정하기 위한 보간 기법을 제안한다. 실험을 통하여 제안한 기법이 CBNUC 기반 적외선 영상 시스템에서 발생하는 규칙적인 패턴의 SFPN을 효율적으로 제거하는 것을 확인하였다. 또한, 제안한 기법은 CBNUC 기반 적외선 영상 시스템에서 주기적으로 수행해야하는 단일점보정 (OPC, One Point Correction)의 수행횟수를 줄이고, 연산량도 적어 실시간 시스템 구현이 가능하다.

  • PDF

V.F. 모델을 이용한 주행차량의 전방 영상계측시스템 설계 (Design of a Front Image Measurement System for the Traveling Vehicle Using V.F. Model)

  • 정용배;김태효
    • 융합신호처리학회논문지
    • /
    • 제7권3호
    • /
    • pp.108-115
    • /
    • 2006
  • 본 논문에서는 주행하는 차선 내에 존재하는 선행차량의 위치측정 및 차량까지의 거리를 정확히 인식하기 위해 차량의 요동에 기인되는 피칭오차를 보정하여 계측하는 알고리듬을 제안하였다. 선행 차량까지의 거리를 정확히 계측하기 위하여 2 차원 영상좌표로부터 사영기하학을 적용하여 3 차원 좌표를 얻을 수 있는 카메라 Calibration 알고리듬을 확립하고, View Frustum(V.F.) 모델을 이용하여 직선부분에 대한 도로의 영상 모델을 제시하였다. 기 발표된 많은 연구논문들은 도로가 평면이라 가정하여 도로와 차량사이의 기하적인 변화에 따른 오차 특성을 고려하지 않은 경우가 많다. 이를 보완하고자 본 논문에서는 카메라 Calibration 알고리듬을 적용하여 실세계 좌표계와 영상좌표 계 사이의 기하해석으로 사영행렬을 추출하였고, V.F. 모델을 이용하여 소실점의 기하적인 해석을 통하여 차량의 피칭변화 에 따른 오차특성을 보정하였다. 실험결과 거리의 오차를 현저하게 줄일 수 있어 피칭변화에 강인함을 확인할 수 있었다.

  • PDF

카메라 모델의 추정과 검증을 통한 광각 카메라 영상의 왜곡 보정 방법 (A Distortion Correction Method of Wide-Angle Camera Images through the Estimation and Validation of a Camera Model)

  • 김경임;한순희;박정선
    • 한국전자통신학회논문지
    • /
    • 제8권12호
    • /
    • pp.1923-1932
    • /
    • 2013
  • 본 논문에서는 광각 카메라로 촬영한 영상에서 생기는 영상의 왜곡 문제를 해결하기 위하여, 카메라 모델의 추정과 검증을 통하여 광각 카메라 영상에서의 방사형 왜곡을 보정하는 방법을 제안한다. 먼저, 교정 패턴으로부터 렌즈의 초점 거리와 주점의 위치 등으로 구성된 내부 파라미터와 회전과 위치 정보로 구성된 외부 파라미터를 찾음으로써 카메라의 왜곡 모델을 추정한다. 다음으로, 추정된 카메라 모델로부터 역으로 코너점을 다시 추출하여 검증하고, 마지막으로, 검증된 카메라 모델을 이용하여 영상의 왜곡을 보정한다. 일반 웹 카메라와 광각 카메라로부터 격자 모양의 교정 패턴을 촬영한 영상을 이용하여 방사형 왜곡을 보정하는 실험을 수행한 결과, 제안된 방법이 80% 이상의 개선 성능을 보임을 확인하였다.

적외선 열화상 기술을 이용한 원자력 배관의 온도측정과 보정에 관한 연구 (A Study on Measuring the Temperature and Revising the Result When Measuring the Temperature of NPP Pipes Using Infrared Thermography)

  • 김경석;정현철;박찬주;김동수;정덕운;장호섭
    • 비파괴검사학회지
    • /
    • 제29권5호
    • /
    • pp.421-426
    • /
    • 2009
  • 열화상 카메라와 대상물의 측정 위치에 따른 방사각도에 따라 방사율은 달라지게 된다. 이로 인해 열화상 시스템을 이용한 온도 측정시 나타나는 온도 분포는 절대적 온도로 볼 수 없다. 대상체의 실제 표면 온도가 일정하더라도 열화상 카메라로 측정된 온도는 방사율 값에 따라 오차를 가지게 된다. 본 논문에서는 동일 온도로 가열된 원통 형태를 가지는 대상체와 평면 형태를 가지는 대상체의 온도를 열화상 카메라를 이용하여 측정하였다. 측정된 표면 온도값을 통하여 화각에 의한 방사율 보정표와 방사각도의 영향에 의한 반사율 보정식을 구하였으며 이를 바탕으로 측정 온도의 오차보정을 수행하였다. 그리고 방사 각도와 화각에 따른 온도 영향을 원자력 배관의 결함 검출에 적용하여 더욱 신뢰성 있는 표면 온도값을 획득하였다.