• Title/Summary/Keyword: Calculated AC/A

Search Result 267, Processing Time 0.027 seconds

Pallidotomy Guided by MRI and Microrecording for Parkinson's Disease (파킨슨환자의 자기공명영상과 미세전극기록을 이용한 담창구 파괴술)

  • Lee, Kyung Jin;Son, Hyung Sun;Park, Sung Chan;Cho, Kyung Keun;Park, Hae Kwan;Choi, Chang Rak
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.1
    • /
    • pp.41-46
    • /
    • 2001
  • Objective : The exact position of the lesion during the pallidotomy is critical to obtain the clinical improvement of parkinson's disease without damage to surrounding structure. Ventriculogrphy, CT(computed tomograpy) or MRI(magnetic resonance imaging) have been used to determine the initial coordinates of stereotactic target for pallidotomy. The goal of this study was to determine whether microelectrode recording significantly improves the neurophysiologic localization of the target obtained from MRI. Methods : Twenty patients were studied. They underwent a unilateral pallidotomy. Leksell frame was applied and T1 axial images parallel to the AC-PC(anterior commissure-posterior commissure) plane using a 1.5 Tesla MRI with 3mm slice thickness were obtained. Anteroposterior coordinate of target was chosen at 2mm in front of the midcommissural point and lateral coordinate between 19 and 22mm from the midline. The vertical coordinate was calculated on coronal slice using a fast spin echo inversion recovery sequence(FSEIR) related to the position of the choroidal fissure and ranged over 4-5mm below the AC-PC plane. Confirmation of the anatomical target was done on axial slices using the same FSEIR sequence . Microrecording was done at the pallidum contralateral to the symptomatic side using an electrode with a tip diameter of $1{{\mu}m}$ diameter tip and 1.1-1.4 mOhm impedance at 1000Hz. Electrophysiologic localization of the target was also confirmed intraoperatively by macrostimulation. Results : Microrecording techniques were reliable to define the transition from the base of the pallidum which was characterized by the disappearance of spike activity and by the change of the audible background activity. Signals from high amplitude neurons firing at 200-400Hz were recorded in the pallidal base. X, Y and Z coordinates of target obtained from the MRI were within 1mm from the X, Y, Z coordinates obtained with microrecording in 16 patients (80%), 15 patients(75%), 10 patients(50%) respectively. The difference of Y coordinate between on MRI and on microrecording was 4mm in only one patient. Conclusion : The MRI was accurate to localize the target within 1mm of the error from microrecording target in 70% of the patients. 4mm discrepancy was observed only once. We conclude that MRI alone can be used to determine the target for pallidotomy in most patients. However, microrecording technique can still be extremely valuable in patents with aberrant anatomy or unusual MRI coordinates. We also consider physiologic confirmation of the target using macrostimulation to be mandatory in all cases.

  • PDF

Characteristics of Microwave Air Plasma With a Wide Range of Operating Pressures (운전압력 변화에 따른 마이크로파 공기 플라즈마의 특성연구)

  • 조정현;장봉철;박봉경;김윤환;정용호;김곤호
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.1
    • /
    • pp.68-75
    • /
    • 2002
  • It is observed the characteristic of the microwave air plasma in the wide range of the operating pressure, 1 mTorr ~ 760 Torr. The microwave air plasma was generated by an AC-type microwave source manufactured with a magnetron taken from a commertial microwave oven and the input power was fixed at 370 W. Characteristics of the plasmas were observed by an injection Langmuir probe and an OES(Optical Emission Spectroscopy). The breakdown electric field is drastically changed at 500 mTorr. For < 500 mTorr, the ratio of the breakdown electric field and the pressure decreased inversely to the pressure, $5.7\times10^4$V/m-Torr.However, the ratio increased linearly as 43 V/m-Torr for the operating pressure, > 500 mTorr. The minimum breakdown electric field was observed about 12. kV/m at 500 mTorr. It corresponds that the input frequency equals to the collision frequency. The effective collision cross section of the air at this pressure was calculated as $9.23\times10^{-l6}\textrm{cm}^2$.The results of the OES measurement revealed that the main ions were composed of the oxygen, argon, and nitrogen for > 500 mTorr. In contrast, only oxygen and argon ions were dominated for < 500 mTorr. ion temperature of oxygen (O(II)) in the air was decreased from about 1.2 eV to 0.5 eV as the pressure increased. Langmuir probe data shows that the plasma density for < 500 mTorr was higher that for > 500 mTorr.

Electron Temperature, Plasma Density and Luminous Efficiency in accordance with Discharge Time in coplanar AC PDPs

  • Jeong, S.H.;Moon, M.W.;Oh, P.Y.;Jeong, J.M.;Ko, B.D.;Park, W.B.;Lee, J.H.;Lim, J.E.;Lee, H.J.;Han, Y.G.;Son, C.G.;Lee, S.B.;Yoo, N.L.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1203-1206
    • /
    • 2005
  • Electron temperature and plasma density in coplanar alternating-current plasma display panels (AC-PDP's) have been experimentally investigated in accordance with discharge time by a micro-probe in this experiment. The resolution of a step mortor to move in micro-Langmuir probe is 10um.[1-3] The used gas in this experiment is He-Ne-Xe (4%) mixure gas. And sustain voltage is 320V which is above of firing voltage for degradation. The electron temperature and plasma density can be obtained from current-voltage (I-V) characteristics of micro Langmuir probe, in which negative to positive bias voltage was applied to the probe. And Efficiency is calculated by formula related discharge power and light emission. Those experiments operated as various discharge time ($0{\sim}72$ Hours). As a result of this experiment, Electron Temperature was increased from 2eV to 5eV after discharge running time of 20 hours and saturates beyond 20 hours. The plasma density is inversely proportional to the square root of electron temperature. So the plasma density was decreased from $1.8{\times}10^{12}cm^{-3}$ to $8{\times}10^{11}cm^{-3}$ at above discharge running time. And the Efficiency was reduced to 70% at 60hours of discharge running time.

  • PDF

Association between the CYP1A2 rs762551 Polymorphism and Bladder Cancer Susceptibility: a Meta-Analysis Based on Case-Control Studies

  • Zeng, Yong;Jiang, Hua-Yong;Wei, Li;Xu, Wei-Dong;Wang, Ya-Jie;Wang, Ya-Di;Liu, Chuan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7249-7254
    • /
    • 2015
  • Background: Previous studies evaluated associations between the CYP1A2 rs762551 polymorphism and bladder cancer risk. However, the results were inconsistent. We therefore performed a meta-analysis of the published case-control studies to assess in detail the association between CYP1A2 rs762551 polymorphism and bladder cancer risk. Materials and Methods: PubMed, Embase and Web of Science were searched to identify relevant studies and the pooled odds ratio (OR) and 95 % confidence interval (95%CI) were calculated. Results: A total of seven articles including 3,013 cases and 2,771 controls were finally included. Overall, a significant association was found between the CYP1A2 rs762551 polymorphism and bladder cancer susceptibility for CC vs AA (OR=0.82, 95% CI=0.69~0.99), but no significant associations were found for the other three models (AC vs AA: OR=0.91, 95% CI=0.81~1.02; the dominant model: OR=0.90, 95% CI=0.80~1.00; the recessive model: OR=0.84, 95% CI =0.72~1.00). In the subgroup analysis by ethnicity, we detected significant associations between the CYP1A2 rs762551 polymorphism and bladder cancer susceptibility for GA vs GG (OR = 0.78, 95% CI =0.64~0.96) and for the recessive model (OR=0.80, 95% CI=0.66~0.96) in Caucasians, but not for Asians. Conclusions: The results from the meta-analysis suggested that the CYP1A2 rs762551 polymorphism is a protective factor for bladder cancer, especially in Caucasians.

Study on the Charge-Transfer Complexes Formed between the Derivatives of Nitrobenzene and Some Organic Solvent Molecules (용매성 유기분자와 니트로벤젠 및 그의 유도체와의 전하전이 착물에 관한 연구)

  • Doo-Soon Shin;Si-Joong Kim
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.2
    • /
    • pp.85-94
    • /
    • 1973
  • The stability constants of the charge-transfer complexes formed between three derivatives of nitrobenzene, i.e., 1,3,5-trinitrobenzene, m-dinitrobenzene, nitrobenzene and eleven organic molecules such as $\alpha-picoline$, pyridine, dimethylsulfoxide, N, N'-dimethylacetamide, tetrahydrofurane, 1, 4-dioxane, diethyl ether, acetonitrile, propylene oxide, epichlorohydrine, and methyl acetate, have been determined by ultraviolet absorption spectroscopy in carbon tetrachloride solution at 25.0$^{\circ}C$. The parameters of the electrostatic effect ($E_D$) and covalent effect ($C_D$) for the eleven organic compounds have been calculated from the modified equation of the double-scale enthalpy,$logK = E_AC_A+E_DC_D$ and also the shift of C=O vibrational frequency in infrared spectra for N,N'-dimethylacetamide have been measured from the solutions of above organic compounds. The empirical equation, ${\Delta}{\nu}_{C=O} = 37.4-5.47E_D+12.1C_D$, related to the parameters and the frequency shift has been derived. It seems that the stabilities of the complexes principally depend on the covalent effect. Especially it is found that $\pi$ orbitals in molecules, in addition to the parameters, play the important role in forming the charge-transfer complexes.

  • PDF

Electrochemical Properties of a Zirconia Membrane with a Lanthanum Manganate-Zirconia Composite Electrode and its Oxygen Permeation Characteristics by Applied Currents

  • Park, Ji Young;Jung, Noh Hyun;Jung, Doh Won;Ahn, Sung-Jin;Park, Hee Jung
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.2
    • /
    • pp.197-204
    • /
    • 2019
  • An electrochemical oxygen permeating membrane (OPM) is fabricated using Zr0.895Sc0.095Ce0.005Gd0.005O2-δ (ScCeGdZ) as the solid electrolyte and aLa0.7Sr0.3MnO3-bScCeGdZ composite (LZab, electrode) as the electrode. The crystal phase of the electrode and the microstructure of the membrane is investigated with X-ray diffraction and scanning electron microscopy. The electrochemical resistance of the membrane is examined using 2-p ac impedance spectroscopy, and LZ55 shows the lowest electrode resistance among LZ82, LZ55 and LZ37. The oxygen permeation is studied with an oxygen permeation cell with a zirconia oxygen sensor. The oxygen flux of the OPM with LZ55 is nearly consistent with the theoretical value calculated from Faraday's Law below a critical current. However, it becomes saturated above the critical current due to the limit of the oxygen ionic conduction of the OPM. The OPM with LZ55 has a very high oxygen permeation flux of ~ 3.5 × 10-6 mol/㎠s in I = 1.4 A/㎠.

Harmonic Analysis for Traction Power Supply System Using Four-Port Network Model (6단자망 회로모델을 이용한 전기철도 급전시스템의 고조파 해석)

  • Chang, Sang-Hun;O, Gwang-Hye;Kim, Ju-Rak;Kim, Jeong-Hun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.6
    • /
    • pp.255-261
    • /
    • 2002
  • Recently, traction motors in trains are supplied with single phase a.c. power. After this power is converted to d.c. power, it is inverted to three phase power to operate traction motors. As going through the process of the conversion, harmonic current is generated in train. The method of conventional analysis on harmonics, studied by RTRI, is modeled with equivalent circuit of ac AT-fed electric railroad system using by the distributed constant circuit. However, this circuit as two-port network model has some difference in comparison with real system. The reason why the conventional method is different from the real system is that the conventional method dose not include three conductor groups, that is catenary, rail, and feeder, and admittance between the conductors for line capacitance. Therefore, this method has a little error. This paper proposes new method to more effectively estimate Harmonic current. In this method, numerous components in electric railway are categorized and each component is defined as a four- port network model. The equivalent circuit for the entire power supply system is also described into a four-port network model with connections of these components. In order to evaluate the efficiency and the accuracy of a proposed method, it is compared with values measured in Kyung-Bu high speed line and ones calculated by the conventional method.

MTHFR Gene Polymorphisms are Not Involved in Pancreatic Cancer Risk: A Meta-analysis

  • Tu, Yu-Liang;Wang, Shi-Bin;Tan, Xiang-Long
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4627-4630
    • /
    • 2012
  • Purpose: Methylenetetrahydrofolate reductase (MTHFR) gene polymorphisms have been reported to be associated with pancreatic cancer, but the published studies have yielded inconsistent results. This study assessed the relationship between MTHFR gene polymorphisms and the risk for pancreatic cancer using a meta-analysis approach. Methods:A search of Google scholar, PubMed, Cochrane Library and CNKI databases before April 2012 was performed, and then associations of the MTHFR polymorphisms with pancreatic cancer risk were summarized. The association was assessed by odds ratios (ORs) with 95% confidence intervals (CIs). Publication bias was also calculated. Results: Four relative studies on MTHFR gene polymorphisms (C667T and A1298C) were included in this meta-analysis. Overall, C667T (TT vs. CC:OR=1.61,95%CI=0.78-3.34; TT vs. CT: OR=1.41,95%CI=0.88-2.25; Dominant model:OR=0.68,95%CI=0.40-1.17; Recessive model: OR=0.82,95%CI=0.52-1.30) and A1298C (CC vs. AA:OR=1.01,95%CI=0.47-2.17; CC vs. AC: OR=0.99,95%CI=0.46-2.14; Dominant model:OR=1.01, 95%CI=0.47-2.20; Recessive model: OR=1.01,95%CI=0.80-1.26) did not increase pancreatic cancer risk. Conclusions: This meta-analysis indicated that MTHFR polymorphisms (C667T and A1298C) are not associated with pancreatic cancer risk.

Compensation of Unbalanced PCC Voltage in Off-shore Wind Farms of PMSG Type Turbine

  • Kang, Jayoon;Han, Daesu;Suh, Yongsug;Jung, Byoungchang;Kim, Jeongjoong;Park, Jonghyung;Choi, Youngjoon
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.215-216
    • /
    • 2014
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

A Study on the Improvement Plan of Toxic Substance Designation Criterion Based on GHS Hazards (GHS 유해성을 기반으로 한 유독물질 지정체계 개선방안 연구)

  • Kim, Hyo-dong;Park, Kyo-shik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.3
    • /
    • pp.209-220
    • /
    • 2022
  • Objectives: This study was performed to suggest how to re-establish criterion for toxic substances under the Chemical Control Act (CCA) in South Korea by comparing the GHS (Globally Harmonized System of Classification and Labeling of Chemicals) score and toxic properties. Methods: Toxic substances were classified into seven groups (Acute toxicity (1A), Chronic toxicity (2C), Environmental hazards (3E), Acute toxicity & chronic toxicity (4AC), Chronic toxicity & environmental hazards (5CE), Acute toxicity & environmental hazards (6AE), and Acute toxicity & chronic toxicity & environmental hazards (7ACE)) according to their toxic properties. The GHS score was calculated to sum up five toxicity indicators (health acute toxicity, health repeated toxicity, carcinogenicity, health other chronic toxicity and environmental hazards). Results: The GHS score of 7ACE was higher by 7 times that of 1A. 1A is the only group which has lower than the total GHS score. The highest score was 47, for sodium chromate (CAS no. 7775-11-3), which belongs to group 7ACE. This is classified as acute toxicity, carcinogenicity, germ cell mutagenicity, reproductive toxicity, and acute and chronic environmental hazard. On the other hand, the lowest score was 2.75, which was assigned to 177 chemicals belonging to group 1A. When the health acute toxicity indicator was omitted from the toxic criterion, toxic substances could be divided into the sub-groups 'human chronic hazards group' (HCG) and 'environmental hazards group' (EG) according to their GHS score and properties. Conclusions: The proposed criterion for toxic substances is to establish sub-groups defined as HCG and EG for separate control and that the 1A group be moved to substances requiring preparation for accidents under the CCA.