• 제목/요약/키워드: Calculated AC/A

검색결과 267건 처리시간 0.033초

Low Temperature Encapsulation-Layer Fabrication of Organic-Inorganic Hybrid Thin Film by Atomic Layer Deposition-Molecular Layer Deposition

  • 김세준;김홍범;성명모
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.274-274
    • /
    • 2013
  • We fabricate encapsulation-layer of OLED panel from organic-inorganic hybrid thin film by atomic layer deposition (ALD) molecular layer deposition (MLD) using Al2O3 as ALD process and Adipoyl Chloride (AC) and 1,4-Butanediamine as MLD process. Ellipsometry was employed to verify self-limiting reaction of MLD. Linear relationship between number of cycle and thickness was obtained. By such investigation, we found that desirable organic thin film fabrication is possible by MLD surface reaction in monolayer scale. Purging was carried out after dosing of each precursor to eliminate physically adsorbed precursor with surface. We also confirmed roughness of the organic thin film by atomic force microscopy (AFM). We deposit AC and 1,4-Butanediamine at $70^{\circ}C$ and investigated surface roughness as a function of increasing thickness of organic thin film. We confirmed precursor's functional group by IR spectrum. We calculated WVTR of organic-inorganic hybrid super-lattice epitaxial layer using Ca test. WVTR indicates super-lattice film can be possibly use as encapsulation in flexible devices.

  • PDF

와전류에 의한 저주파 자기장 차폐 성능 평가 (Performance Evaluation of Low Frequency Magnetic Field Shielding by Eddy-Current)

  • 최학윤
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.124-128
    • /
    • 2010
  • In this paper, the shielding effectiveness of aluminum shielded room with using eddy-current is calculated and measured after fabricated. The size and thickness of shielded room are decided as $2.4{\times}2.4{\times}2.4[m^3]$ and 12[mm] after AC shielding characteristics by eddy-current of conductive materials is analyzed. To verify the shielding effectiveness, a rectangular helmholtz coil is fabricated to generate magnetic field of 1.37[${\mu}T$] and measured magnetic field inside shielding room for 0.01~10[Hz]. According to calculations and measurements, AC Shielding effectiveness by eddy-current in aluminum is very small for 0.01~2[Hz] and 5 times to 11 times for 5~10[Hz].

PWM 컨버터 제어기 이득의 해석적 설계 (A Study on Design of Controller Gain for PWM Converter)

  • 고재석;조준석;강병희;최규하;곽철훈;정석언
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.491-495
    • /
    • 2001
  • Compare with diode or thyristor bridge AC/DC converter, the 3 phase PWM converter has some merits of low THD and unit power factor. So, in many critical application like as UPS, using PWM converter is the trends. 3 phase PWM converter had been studied widely already. But analytical design procedure can not found from publication for hardware design and controller design. So, in this paper, 3 phase PWM converter analysis review was given. And from the DC analysis result, parameter design was done. From the AC model, the voltage controller and current controller was designed. The gain of controllers was calculated by analytical method.

  • PDF

Minimization of DC-Link Capacitance for NPC Three-level PWM Converters

  • Alemi, Payam;Lee, Dong-Choon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.370-371
    • /
    • 2011
  • This paper presents a control algorithm that minimizes the DC-link capacitance by decreasing the capacitor current. The capacitor current can be nullified by a feedback compensation term which is calculated from the power balance in the AC/DC converter. As a result, voltage variation in the DC-link is reduced further, which makes a large reduction in the size of DC-link capacitors which are expensive and have limitations in life time. Simulations are performed with two 80uF DC-link capacitors, which can be replaced by film capacitors.

  • PDF

저압 방전등 교류 접등 특성의 이론적 예측 (Theoretical Prediction of AC Characteristics of Low Pressure Lamps)

  • 지철근;장우진;여인선;이진우
    • 대한전기학회논문지
    • /
    • 제38권6호
    • /
    • pp.470-476
    • /
    • 1989
  • In order to develop a mathematical model which can predict the operating voltage and current of a discharge lamp, the properties and the physical phenomena of a low pressure gas discharge are investigated. Fluorescent lamp which uses a low pressure mercury-argon gas discharge is used in the model development. In a low pressure mercur-argon gas discharge, the continuity equation for each excited atom and electron, and the electron energy balance equation can predict the physical quantities of discharge. By coupling these equations and the circuit equation, the electrical characteristics of the discharge lamp can be predicted. To verify the validity of the suggested model, we calculated the voltage and current of a fluorescent lamp operating with inductor ballast for source frequency of 5KHz, 8KHz, 10KHz, and 13KHz. The results show good agreements in wave forms between the measured voltage and current, and the difference between the measured and calculated one is less than 5%.

  • PDF

Ab Initio Conformational Study on Ac-Pro-$NMe_2$: a Model of Polyproline

  • Kang, Young-Kee
    • 한국생물물리학회:학술대회논문집
    • /
    • 한국생물물리학회 2003년도 정기총회 및 학술발표회
    • /
    • pp.75-75
    • /
    • 2003
  • We report here the results on N-acetyl-N'-dimethylamide of proline (Ac-Pro-NM $e_2$) calculated using the ab initio molecular orbital method with the self-consistent reaction field (SCRF) theory at the HF level with the 6-31+G(d) basis set to investigate the conformational preference of polyproline depending on the cis/trans peptide bonds and down/up puckerings along the backbone torsion angle $\square$ in the gas phase, chloroform, and water. In the gas phase, Ac-Pro-NM $e_2$ has seven local minima of tFd, tFu, cFd, cFu, cAu, tAu, and cAd conformations. In particular, polyproline conformations tFd, tFu, cFd, and cFu are found to be more stable than $\square$-helical conformations cAu, tAu, and cAd. In contrast, Ac-Pro-NHMe has seven local minima of tCd, tCu, cBd, cAu, tAu, cFd, and cFu conformations. Conformations tCd and tCu are found to be most stable, which is ascribed to the intramolecular hydrogen bond between C=O of acetyl group and $N^{~}$ H of N'-methyl amide group. The stability of the cFd conformation (i.e., the polyproline I structure) in chloroform is somewhat increased, relative to that in water, although tFd and tFu conformations (i.e., the polyproline II structure) are dominate both in chloroform and water. The population of backbone conformations feasible in chloroform and water is consistent with the experiments. This work is supported by a Korea Research Foundation Grant (KRF-2002-041-C00129).

  • PDF

Optical, thermal and gamma ray attenuation characteristics of tungsten oxide modified: B2O3-SrCO3-TeO2-ZnO glass series

  • Hammam Abdurabu Thabit;Abd Khamim Ismail;M.I. Sayyed;S. Hashim;I. Abdullahi;Mohamed Elsafi;K. Keshavamurthy;G. Jagannath
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.247-256
    • /
    • 2024
  • The glass series modified by tungsten oxide was created using the compounds (75-x) B2O3- 10SrCO3- 8TeO2- 7ZnO - xWO3, where x = 0, 1, 5, 10, 22, 27, 34, and 40% mole percentage. A UV-visible spectrophotometer and thermogravimetric-differential thermal analysis (TG-DTA) methods were employed to characterize the specimen's optical and phase transition attributes, respectively. The mass-attenuation coefficient (AC) of all created glasses from BSTZW0 to BSTZ7 was estimated using Geant4 code from 0.05 to 3 MeV and compared to the XCOM software results, with a relative difference of less than 2% between the two results. The increase of WO3 percentage lead to an increase in the Linear-AC at each studied energy, and this is mainly due to the fact that the higher the percentage of WO3 in the glass increases its density which causes an increase in the Linear-AC, so an energy of 0.06 MeV, as an example, the values of the Linear-AC was 4.009, 4.509, 5.442, 6812, 8.564, 9.856, 10.999 and 11.628 cm-1 form BSTZW0 too BSTZW7, respectively. The Half-VL (value layer), Mean-FP (free path), Tenth-VL, and Radiation attenuation performance (RAP) were also calculated for the current BSTZW-glass samples and revealed that BSTZW7 had the best gamma ray attenuation performance at all discussed energies when compared to other studied glass samples.

알칼리금속염으로 처리된 활성탄에 대한 CO2의 흡착특성 (Adsorption Characteristics of CO2 on Activated Carbons Treated with Alkali-metal Salts)

  • 유동관;김성현
    • 공업화학
    • /
    • 제9권2호
    • /
    • pp.286-293
    • /
    • 1998
  • 연소배가스로부터 $CO_2$를 선택적으로 분리하기 위한 활성탄 흡착공정 사용시 흡착능 향상을 위하여 $CO_2$와 친화력이 있는 화합물을 함침시키는 방법과 KOH를 함침시킨 후 고온에서 열처리하므로서 활성화시키는 방법이 사용되었다. 알칼리금속, 알칼리토금속, 또는 전이금속의 염화물을 함침시킨 활성탄에 대한 $CO_2$의 흡착량을 측정한 결과 함침 전의 활성탄의 흡착량보다 적었다. 이것은 함침되는 물질이 $CO_2$에 대한 친화력이 없이 단지 활성탄의 미세기공만 막는 결과임을 알 수 있었다. 알칼리금속수산화물 중 KOH를 함침시킨 활성탄에 대한 $CO_2$의 파과실험 결과 유입되는 기체에 수분이 있을 경우 흡착량이 증가했는데 이것은 KOH가 $CO_2$를 흡수하는 성질 때문이었다. 그러나 이 흡착제에 함친된 KOH가 $CO_2$와 반응하여 $K_2CO_3$로 변함에 따라 재현성이 없음을 알 수 있었다. KOH를 함침시킨 후 $800^{\circ}C$에서 열처리하여 활성화시킨 활성탄의 경우 함침된 KOH의 양이 증가할수록 $CO_2$의 흡착량이 증가했으며, KOH와 활성탄의 무게비(KOH/Activated-Carbon)가 4일 때 최대였다. 이 흡착제에 대해 온도별로 측정된 $CO_2$의 흡착량으로부터 Clausius-Clapeyron식을 이용하여 등량흡착열을 구했다. 그리고 고정층 파과실험을 통해 $CO_2$농도와 유속에 따른 파과특성을 살펴보았다.

  • PDF

Magnetic Characterization of the Nd Based Permanent Magnet by Newly-Developed Bipolar Pulse-Type Hysteresis Loop Tracer

  • Rhee, J.R.
    • Journal of Magnetics
    • /
    • 제4권3호
    • /
    • pp.73-75
    • /
    • 1999
  • By appliying an slternate pulsed magnetic field -generated by using a sequential ignition circuit and a magnet exciting circuit- with peak value of about 10 T to the rod type Nd based magnet Nd2Fe12.7Cr1.3B with length of 5 mm and diameter of 3.6 mm, the basic magnetic properties such as saturation magnetization, residual magnetization, coercivity, maximum energy products, magnetic anisotropy and anisotropic field are investigated with obtaining the major and minor J-H loops of the magnet. The increase in coercivity due to eddy currents in ac measurement of coercivity is calculated considering eddy current loss by analyzing a wave of generating magnetic field. The average coercivity calculated for the magnet is about 12.2 kOe, anisotropy magnetic field and anisotropic constant are measured as 60 kOe 2.43 Mj/$m^3$, respectively.

  • PDF

Modified Transmission Line Protection Scheme in the Presence of SCC

  • Naeini, Ehsan Mostaghimi;Vaseghi, Behrouz;Mahdavian, Mehdi
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.533-540
    • /
    • 2017
  • Distance relay identifies the type and location of fault by measuring the transmission line impedance. However any other factors that cause miss calculating the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of the important factors which directly changes the measured impedance by the relay is series capacitive compensation (SCC). Another factor that changes the calculated impedance by distance relay is fault resistance. This paper provides a method based on the combination of distance and differential protection. At first, faulty transmission line is detected according to the current data of buses. After that the fault location is calculated using the proposed algorithm on the transmission line. This algorithm is based on active power calculation of the buses. Fault resistance is calculated from the active powers and its effect will be deducted from calculated impedance by the algorithm. This method measures the voltage across SCC by phasor measurement units (PMUs) and transmits them to the relay location via communication channels. The transmitted signals are utilized to modify the voltage signal which is measured by the relay. Different operating modes of SCC and as well as different faults such as phase-to-phase and phase-to-ground faults are examined by simulations.