• 제목/요약/키워드: Cage-type induction generator

검색결과 11건 처리시간 0.029초

농형 유도발전기와 권선형 유도발전기의 특성비교 (Comparison of Squirrel cage and Wound induction generator characteristics in Wind Power System)

  • 김찬기;이원교;임철규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.469-471
    • /
    • 2005
  • Wind farms employs induction generators which are two type, one is Squirrel cage for fixed speed wind turbines and the other is Wound induction generator (doubly fed induction generator DFIG) for variable speed wind turbines. this paper describes grid connection scheme of wind power system using two type induction generators and simulation results show the characteristics of two type induction generators.

  • PDF

PSCAD/EMTDC를 이용한 계통 연계 풍력 유도 발전기의 운전 특성에 관한 연구 (A Study on Operational Characteristics of Wind Turbine Induction Generators Interconnected with Distribution Networks Using PSCAD/EMTDC)

  • 장성일;정종찬;김광호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권12호
    • /
    • pp.704-713
    • /
    • 2002
  • This paper describes operational characteristics of wind turbine induction generators interconnected with distribution networks using PSCAD/EMTDC. Due to the simple and durable structure, induction generators are the most common type used in wind Power generation. Generally, induction generators are classified into two groups according to the shape of rotor, one is squirrel-cage type and the other is wound-rotor type. In this study, we simulate the start-up and the output variation of generators interconnected with distribution networks and compare the operational characteristics of squirrel -cage type and wound-rotor type induction generators located in the unfaulted distribution lines about the disturbance occurred on the associated distribution feeders emanated from the substation to which wind turbine generator is connected. In order to obtain the realistic results, we use the radial distribution network of IEEE 13-bus model.

농형 유도발전기를 이용한 독립형 풍력발전시스템의 최대출력제어 (Maximum Output Power Control for Stand-Alone Wind Power Generation System Using Cage-Type Induction Generators)

  • 김형균;이동춘;석줄기
    • 전력전자학회논문지
    • /
    • 제9권1호
    • /
    • pp.73-80
    • /
    • 2004
  • 본 논문에서는 농형유도발전기를 이용한 독립형 풍력발전시스템의 최대전력 추종제어기법을 제안한다. 농형 유도발전기는 벡터제어 방식으로 동작되는데 d-축 전류에 의해 여자가 제어되고 q-측 전류에 토크가 제어된다. 이 토크제어에 의해 발전기는 풍속의 변화에 따라 최대전력을 발생하도록 가변속 제어된다. 발전된 전력은 ac/dc PWM 컨버터에 의해 직류 출력단 배터리뱅크로 충전된다. 제안된 기법은 M-G세트로 구성된 터빈시뮬레이터를 이용하여 실험적으로 검증된다.

농형 유도발전기를 이용한 계통연계형 가변속 풍력발전시스템 (Grid-Connected Variable Speed Wind Power Generation System Using Cage-Type Induction Generators)

  • 김형균;이동춘;석줄기
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.397-404
    • /
    • 2004
  • 본 논문에서는 농형유도발전기를 이용한 계통연계형 풍력발전시스템의 가변속제어 기법이 제안된다. 농형유도발 전기는 간접벡터제어 방식으로 동작되는데 d-축 전류에 의해 여자가 제어되고 q-축 전류에 토크가 제어된다. 이 토크제어에 의해 발전기는 풍속의 변화에 대해서 항상 최대전력을 발생하도록 가변속 제어된다. 발전된 전력은 back-to-back PWM 컨버터에 의해 계통으로 공급된다. 계통측 컨버터는 q-축 전류 제어에 의해 직류링크 전압을 제어하고 d-축 전류 제어에 의해 계통측 역률을 제어할 수 있다. 제안된 기법은 M-G세트로 구성된 터빈시뮬레이터를 이용하여 실험적으로 검증된다.

풍력발전용 농형유도발전기의 최대출력제어 (Maximum Output Control of Cage-Type Induction Generator for Wind Power Generation)

  • 구성영;이동춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.288-292
    • /
    • 2001
  • In this paper, a maximum power control of a low-cost and rugged cage-type induction generator system is proposed, where the machine-side PWM converter is used for maximum power generation and field excitation control, and the line-side PWM inverter is used for the dc link voltage control and source-side power factor control. Simulation results through Matlab Simulink have been demonstrated.

  • PDF

농형 풍력 유도발전기의 운전 특성에 관한 연구 (A Study on the Operational Characteristics of a Squirrel-cage type Wind Turine Induction Generator)

  • 장성일;정종찬;최정환;박제영;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1309-1312
    • /
    • 2002
  • The electric power network paralleled with wind turbine generator may have the negative impacts on the protection, operation, and management caused by the operation of wind turbine generator. Therefore, it is necessary to investigate the operating characteristic of wind turbine generator. This paper describes model of a squirrel-cage type wind turbine induction generator and the soft cut-in connection method for reducing the transient state on power network, and simulates various cases of wind turbine operations. The radial distribution network of IEEE 13-bus are modeled and tested by PSCAD/EMTDC.

  • PDF

퍼지제어를 이용한 풍력발전 시스템의 최대출력 제어 (Maximum Output Power Control of Wind Generation System Using Fuzzy Control)

  • 아보칼릴 아메드;김영신;이동춘
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권10호
    • /
    • pp.497-504
    • /
    • 2005
  • For maximum output power, wind turbines are usually controlled at the speed which is determined by the optimal tip-speed ratio. This method requires information of wind speed and the power conversion coefficient which is varied by the pitch angle control. In this paper, a new maximum output power control algorithm using fuzzy logic control is proposed, which doesn't need this information. Instead, fuzzy controllers use information of the generator speed and the output power. By fuzzy rules, the fuzzy controller produces a new generator reference speed which gives the maximum output power of the generator for variable wind speeds. The proposed algorithm has been implemented for the 3[kW] cage-type induction generator system at laboratory, of which results verified the effectiveness of the algorithm.

농형 유도발전기를 이용한 계통 연계형 풍력발전 시스템 (Grid-Connected Wind Power Generation System Using Cage-Type Induction Generators)

  • 김형균;;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.73-76
    • /
    • 2003
  • This paper proposes a maximum output power control of grid-connected wind power generation system using cage-type induction generators. For generator control, indirect vector control is used, where d-axis current controls the excitation level and q-axis current controls the generator speed. The generated power flows into the utility through the grid-side converter, by which the do link voltage is controlled to be constant and the ac current is controlled in sinusoid and. The generator speed is adjusted according to wind speed for extracting maximum power generation. Experimental results are shown to verify the validity of the proposed scheme.

  • PDF

농형유도발전기를 이용한 독립형 풍력발전시스템의 가변속 제어 (Adjustable Speed Control of Stand-Alone Wind Power Generation System using Squirrel-Cage Induction Generators)

  • 김형균;이강주;이동춘;석줄기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.338-340
    • /
    • 2003
  • This paper proposes a stand-alone adjustable speed wind Power generation system using a cage-type induction generator. Indirect vector control is used, where the q-axis current controls the generator speed and the d-axis current controls the excitation level. The generator speed is adjusted according to the wind speed so as to produce the maximum output power. The generated power is charged in the battery bank through ac/dc PWM converter. The proposed scheme has been verified by the experimental results.

  • PDF

터빈의 동특성을 고려한 풍력 터빈 시뮬레이터 (Wind Turbine Simulators Considering Turbine Dynamic Characteristics)

  • 박홍극;아보칼릴 아메드;이동춘
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.617-624
    • /
    • 2008
  • This paper proposes design and implementation of wind turbine simulators which incorporate the turbine dynamic characteristics. At first, the turbine output characteristic in steady state is modelled as a function of wind speed and then dynamic characteristics are modelled such as pitch angle control, torsional vibration, tower shadow effect, wind shear effect, and inertia effect. In addition, a wind speed simulator is developed which can generate the real wind speed pattern. The wind turbine simulator is implemented with 3[kW] M-G set(cage-type induction motor coupled with doubly-fed induction generator) at laboratory.