• 제목/요약/키워드: Cage System

검색결과 264건 처리시간 0.028초

Wing Technique: A Novel Approach for the Detection of Stator Winding Inter-Turn Short Circuit and Open Circuit Faults in Three Phase Induction Motors

  • Ballal, Makarand Sudhakar;Ballal, Deepali Makarand;Suryawanshi, Hiralal M.;Mishra, Mahesh Kumar
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.208-214
    • /
    • 2012
  • This paper presents a novel approach based on the loci of instantaneous symmetrical components called "Wing Shape" which requires the measurement of three input stator currents and voltages to diagnose interturn insulation faults in three phase induction motors operating under different loading conditions. In this methodology, the effect of unbalanced supply conditions, constructional imbalances and measurement errors are also investigated. The sizes of the wings determine the loading on the motor and the travel of the wings while their areas determine the degree of severity of the faults. This approach is also applied to detect open circuit faults or single phasing conditions in induction motors. In order to validate this method, experimental results are presented for a 5 hp squirrel cage induction motor. The proposed technique helps improve the reliability, efficiency, and safety of the motor system and industrial plant. It also allows maintenance to be performed in a more efficient manner, since the course of action can be determined based on the type and severity of the fault.

Evaluation of a Newly Developed Fish Meal Analogue (BAIFA-M) in Immature Korean Rockfish, Sebastes schlegeli, Reared in Cage Culture System

  • Kim, Kang-Woong;Choi, Jae-Young;Sungchul C. Bai
    • 한국양식학회지
    • /
    • 제13권3호
    • /
    • pp.259-265
    • /
    • 2000
  • Four experimental diets were formulated to contain white fish meal (WFM) andvor BAIFA-M as the main animal protein source to determine the optimum BAIFA-M level to replace WFM protein. The diets contained 100% WFM + 0% BAIFA-M in the diet M$_0$ (control) . 70%, WFM+30%, BAIFA-M in the diet M$_{30}$, 55 % WFM+45 % BAIFA-M in the diet M$_{45}$, ; 40 % WFM+60 % BAIFA-M in the diet M$_{60}$. The four groups of rockfish (232 g), receiving the four different diets, were fed for 8 weeks. Groups receiving M$_0$, M$_{30}$ and M$_{45}$/ diets did not show significant (P>0.05) difference in growth and feed efficiency; however, the group fed on M$_{60}$/ showed significantly slower growth and lower feed efficiency than the others. Body composition showed no significant difference among the four dietary groups. WFM protein can be replaced by BAIFA-M up to 45 % in the diet of the rockfish.

  • PDF

음향 텔레메트리에 의한 조피볼락의 귀소범위 및 귀소경로 측정 (Home Ranges and Homing Routes of the Black Rockfish Sebastes schlegeli Measured by Acoustic Telemetry)

  • 강경미;신현옥
    • 한국수산과학회지
    • /
    • 제41권3호
    • /
    • pp.221-227
    • /
    • 2008
  • The black rockfish (Sebastes schlegeli) is an important commercial species in Korean fisheries. We used acoustic telemetry using coded ultrasonic transmitters to track the home ranges and homing routes of the black rockfish that inhabit in the Tongyeong marine ranching area. Twenty-four fish were released at five points. The distance from the capture point (C1) to the released point was 0 (R7), 0.2 (R1), 0.9 (R2), 1.3 (R3) and 1.9 (R4) km. Two of the three fish released at R1 (0.2 km) returned home in under 48hrs. Another was found 0.8km from C1. Two of the five fish released at R2 returned home, but it took over 250 days. None of the ten fish released at R3 and R4 returned home. Three of the ten fish moved 1.1-2.6 km from C1 and were found near a cage or a natural reef. Six fish were released at R7. The younger the fish, the wider was its movement range around the artificial reefs. Fish over 3 years old were likely to move less far.

솔레노이드 장치를 이용한 양식용 부자 LED 전원공급 시스템 개발 (Development for auto lightening buoy system using solenoid)

  • 차봉진;배봉성;김현영;조삼광;이건호
    • 수산해양기술연구
    • /
    • 제52권1호
    • /
    • pp.17-23
    • /
    • 2016
  • This study investigates the development of an automatic lightening buoy that can indicate an aquaculture cage at night or in rough weather. The energy for the light is generated by the linear motion of a magnet along with a coil inside the buoy as the waves cause the buoy to oscillate up and down. The principle of the magnet motion is different between the magnet and body of the buoy because the movement of the latter is dependent on the surface wave, while the former is affected by the damper. To obtain a quantitative performance of the buoy, the voltage as well as up and down motion produced by several waves were measured in the wave tank. A shorter wave period, i.e., faster motion, of the magnet produced a brighter light. It is expected that this study can aid in deciding the optimum design of a buoy capable of producing a bright light at any aquaculture site affected by sea or fresh water waves.

유도전동기를 발전기로 사용시 동작 특성 해석 (Analysis for the Operating Characteristics when the Induction Motor is Used as a Generator)

  • 김종겸
    • 신재생에너지
    • /
    • 제10권2호
    • /
    • pp.5-11
    • /
    • 2014
  • Squirrel cage induction motor is the main driving system of industrial field and familiar with its use in a large variety of applications. The structure and operating characteristics of induction generator is almost identical to induction motor, but the induction generator part is used restrictively from hydropower power and wind power development etc. Recently induction generator is commonly used for micro & small hydro power applications due to its simplicity, reliability, low cost and robustness. Input and output of induction motor has turned against at the induction generator operation. Rotation speed of induction generator is small faster than synchronous speed of induction motor. As output of induction machines increases with the increasement of speed, so loss is same. Actually, generator efficiency is lower than motor at this condition. If induction generator is connected with mechanical load such as increaser, total efficiency is decreased. Consequently the quality in compliance with an induction motor parameter applying like that in the generator is a possibility of having the error of some. In this paper, we analyzed that input, output, torque and efficiency of induction machine is different from each other above and below synchronous speed.

Preserved Respiratory Function after Reconstruction of a Large Chest Wall Defect

  • Kim, Yu Jin;Kim, Yoon Ji;Lee, Jae-Ik
    • Archives of Reconstructive Microsurgery
    • /
    • 제24권1호
    • /
    • pp.28-31
    • /
    • 2015
  • A case report of a patient who developed radiation-induced sarcoma in the left chest wall is presented. The patient had partial mastectomy and adjuvant radiation therapy (total dose, 5,220 cGy) and chemotherapy. Five years later, she visited with rapidly growing mass with central ulceration in the irradiated chest wall. The mass was diagnosed as malignant fibrous histiocytoma. The chest wall mass resected en bloc ($23{\times}18cm$) including five consecutive ribs. After the defected thoracic cage was reinforced using a polytetrafluoroethylene patch, omental flap and split thickness skin graft was done for soft tissue coverage. We applied negative pressure wound closer system for effective suction of omeantal exudate. The wound healed without complications. The patient suffered no perioperative pulmonary complications. Pulmonary function tests showed no significant changes. Each of Gore-Tex, omental flap, negative pressure wound therapy and skin graft is widely used method. However, If these methods are used in combination, we can reconstruct the large defect of chest wall including multiple ribs without any repiratory function problems.

금속이온교환된 Mg/Cu-ZSM-5 촉매를 사용한 배연 탈질 공정에서 De-NOx활성 비교연구 (A Comparative Study on the NOx Removal Activities of Metal-ion-exchanged Mg/Cu-ZSM-5 Catalysts in the Treatment of Flue Gas from Stationary Sources)

  • 김재천;이병용;정석진
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.421-428
    • /
    • 1996
  • In this study, in order to make up its draw-back in Cu-ZSM-5 catalytic system, some of transition metals or alkaline earth metals were cocation-exchanged in Cu-ZSM-5. Among various cocation-ion-exchanged ZSM-5 catalysts, Mg/Cu-ZSM-5 has been found the most active and durable in NOx reduction even at high oxygen content as well as at the presence of water vapor. The role of Mg in ZSM-5 is supposed to prevent the dealumination of aluminum ions in super-cage even at harsh hydro-thermal conditions, and also it seems to stabilize the Cu ions in the structure. In order to prepare commercially available catalysts, Mg/Cu-ZSM-5 catalysts were wash-coated on the surface of honeycomb type monolith, and tested in terms of catalytic activities. As a result, it was found that the catalyst prepared bt the wash-coating showed satisfactorily high NOx conversion for the practical use in SCR process.

  • PDF

유도전동기용 이상 PI형 속도제어기의 구성 (The Implementation of a Discrete PI Speed Controller for an Induction Motor)

  • 김광배;고명삼
    • 대한전기학회논문지
    • /
    • 제35권1호
    • /
    • pp.26-35
    • /
    • 1986
  • In this paper, non-linear state equations for a 3-phase, 220V, 0.4 KW, squirrel cage induction motor have been derived using the d-q transformation and then these equations have been linearized around an operating point by a small perturbation method. Root loci on the s-plane with repect to the changes of slip S and supply frequency f have been studied. Based on the above results, the derived linear state equations have been augmented to the 6th order, including the output velocity feedback and a discrete PI speed controller. Using the new state equations, stability regions on the Kp-Kl plane have been investigated for slip S and sampling time T. In designing a discrete PI controller, the coefficients Kp and Kl around the normal operating point (220V,1,692rpm,60Hz)have been chosen under the assumptions that each response to a perturbation input of reference speed and load torque be underdamped and dominated by a pair of complex poles. Step responses in the experimental system using an Intel SDK-86 and an optimized PWM inverter show satisfactory results that the maximum overshoots and damped frequency are well coincided with ones from the computer simulation.

  • PDF

Experimental characterization of timber framed masonry walls cyclic behaviour

  • Goncalves, Ana Maria;Ferreira, Joao Gomes;Guerreiro, Luis;Branco, Fernando
    • Structural Engineering and Mechanics
    • /
    • 제53권2호
    • /
    • pp.189-204
    • /
    • 2015
  • After the large destruction of Lisbon due to the 1755 earthquake, the city had to be almost completely rebuilt. In this context, an innovative structural solution was implemented in new buildings, comprising internal timber framed walls which, together with the floors timber elements, constituted a 3-D framing system, known as "cage", providing resistance and deformation capacity for seismic loading. The internal timber framed masonry walls, in elevated floors, are constituted by a timber frame with vertical and horizontal elements, braced with diagonal elements, known as Saint Andrew's crosses, with masonry infill. This paper describes an experimental campaign to assess the in-plane cyclic behaviour of those so called "frontal" walls. A total series of 4 tests were conducted in 4 real size walls. Two models consist of the simple timber frames without masonry infill, and the other two specimens have identical timber frames but present masonry infill. Experimental characterization of the in-plane behaviour was carried out by static cyclic shear testing with controlled displacements. The loading protocol used was the CUREE for ordinary ground motions. The hysteretic behaviour main parameters of such walls subjected to cyclic loading were computed namely the initial stiffness, ductility and energy dissipation capacity.

실험동물 사육실용 바이오 크린룸(BCR)의 급기 온도 및 풍속 변화 특성에 관한 수치해석적 연구 (A Study on the Variation of Airflow Velocity and Temperature upon the Design of Bio Clean Room(BCR) for Laboratory Animal Facilities by Numerical Simulation)

  • 박동일;정광섭;김영일;김성민
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.578-584
    • /
    • 2012
  • In this study, the analysis on the distribution of indoor airflow velocity and temperature by using numerical simulation has carried out to make fundamental data for establishing the optimum design of laboratory animal facilities. From the results, it was found that replacement of cage lacks, air supply and exhaust system, supply air temperature, supply air velocity affect to the optimum design of laboratory animal facilities as a important element.