• 제목/요약/키워드: Cage

검색결과 1,288건 처리시간 0.029초

효소처리어분에 대한 치어기 대서양 참다랑어(Thunnus thynnus)의 in vivo 및 in vitro 소화율 평가 (In vivo and In vitro Digestibility of Enzyme-treated Fish Meal for Juvenile Atlantic Bluefin Tuna Thunnus thynnus)

  • 신재형;지승철;이경준
    • 한국수산과학회지
    • /
    • 제53권3호
    • /
    • pp.423-431
    • /
    • 2020
  • This study was conducted to investigate in vivo and in vitro digestibility in juvenile Atlantic Bluefin tuna Thunnus thynnus. In vivo digestibility was compared between four experimental diets to determine the optimum dietary inclusion level of an enzyme-treated sardine fish meal (EFM) and sardine fish meal (FM). The experimental diets were as follows; EFM75 (75% EFM), EFM60 (60% EFM and 15% FM), FM75 (75% FM) and SL (frozen sand lance) as a raw fish feed. Feces of Bluefin tuna (90.3 g) were collected both by siphoning from a 700 L cage and by dissection in 69 ton concrete rearing tanks. For the siphoning method, protein digestibility was higher in the tuna fed SL diet than that of other groups. The lowest protein digestibility was observed in FM75. For the dissection method, protein digestibility was higher in tuna fed EFM75 diet than that of other groups. The lowest protein digestibility was observed in the EFM60 group. In vitro digestibility was compared in six protein sources to find an alternative source of EFM for the tuna feed. The highest in vitro digestibility was observed in EFM (92%) followed by low temperature FM (72%), meat meal (65%), feather meal (60%), sardine fish meal (57%) and poultry by-product meal (55%).

Clinical Comparison of Posterolateral Fusion with Posterior Lumbar Interbody Fusion

  • Kim, Chang-Hyun;Gill, Seung-Bae;Jung, Myeng-Hun;Jang, Yeun-Kyu;Kim, Seong-Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권2호
    • /
    • pp.84-89
    • /
    • 2006
  • Objective : The purpose of this study is to compare the outcomes of two methods for stabilization and fusion : Postero-Lateral Fusion [PLF, pedicle screw fixation with bone graft] and Posterior Lumbar Interbody Fusion [PLIF, cage insertion] for spinal stenosis and recurred disc herniation except degenerative spondylolisthesis. Methods : Seventy one patients who underwent PLF [n=36] or PLIF [n=35] between 1997 and 2001 were evaluated prospectively. These two groups were compared for the change of interbody space, the range of segmental angle, the angle of lumbar motion, and clinical outcomes by Prolo scale. Results : The mean follow-up period was 32.6 months. The PLIF group showed statistically significant increase of the interbody space after surgery. However, the difference in the change of interbody space between two groups was insignificant [P value=0.05]. The range of segmental angle was better in the PLIF group, but the difference in the change of segmental angle was not statistically significant [P value=0.0l7]. Angle of lumbar motion was similar in the two groups. Changes of Prolo economic scale were not statistically significant [P value=0.193]. The PLIF group showed statistically significant improvement in Prolo functional scale [P value=0.003]. In Prolo economic and functional scale, there were statistically significant relationships between follow-up duration [P value<0.001]. change of interbody space [P value<0.001], and range of segmental angle [P value<0.001]. Conclusion : Results of this study indicate that PLIF is superior to PLF in interbody space augmentation and clinical outcomes by Prolo functional scale. Analysis of clinical outcomes showed significant relationships among various factors [fusion type, follow-up duration, change of interbody space, and range of segmental angle]. Therefore, the authors recommend instrumented PLIF to offer better clinical outcomes in patients who needed instrumented lumbar fusion for spinal stenosis and recurred disc herniation.

Lateral Lumbar Interbody Fusion and in Situ Screw Fixation for Rostral Adjacent Segment Stenosis of the Lumbar Spine

  • Choi, Young Hoon;Kwon, Shin Won;Moon, Jung Hyeon;Kim, Chi Heon;Chung, Chun Kee;Park, Sung Bae;Heo, Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권6호
    • /
    • pp.755-762
    • /
    • 2017
  • Objective : The purpose of this study is to describe the detailed surgical technique and short-term clinical and radiological outcomes of lateral lumbar interbody fusion (LLIF) and in situ lateral screw fixation using a conventional minimally invasive screw fixation system (MISF) for revision surgery to treat rostral lumbar adjacent segment disease. Methods : The medical and radiological records were retrospectively reviewed. The surgery was indicated in 10 consecutive patients with rostral adjacent segment stenosis and instability. After the insertion of the interbody cage, lateral screws were inserted into the cranial and caudal vertebra using the MISF through the same LLIF trajectory. The radiological and clinical outcomes were assessed preoperatively and at 1, 3, 6, and 12 months postoperatively. Results : The median follow-up period was 13 months (range, 3-48 months). Transient sensory changes in the left anterior thigh occurred in 3 patients, and 1 patient experienced subjective weakness; however, these symptoms normalized within 1 week. Back and leg pain were significantly improved (p<0.05). In the radiological analysis, both the segmental angle at the operated segment and anterior disc height were significantly increased. At 6 months postoperatively, solid bony fusion was confirmed in 7 patients. Subsidence and mechanical failure did not occur in any patients. Conclusion : This study demonstrates that LLIF and in situ lateral screw fixation may be an alternative surgical option for rostral lumbar adjacent segment disease.

An Evaluation of the Quality of Sleep Before and After Surgical Treatment of Patients with Cervical Disc Herniation

  • Ogden, Mustafa;Akgul, Mehmet Huseyin;Yuksel, Ulas;Bakar, Bulent;Kamasak, Kagan;Ozveren, Mehmet Faik
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권5호
    • /
    • pp.600-607
    • /
    • 2018
  • Objective : It has been reported in recent studies that 50-80% of patients with cervical disc hernia have concomitant sleep disorders. The aim of this study was to evaluate the quality of sleep before and after surgical treatment in patients with cervical disc hernia and to assess the effects on treatment. Methods : The study included 32 patients performed discectomy and fusion with an intervertebral cage through the right anterior cervical approach. Oswestry Disability Index (ODI), Visual Analog Scale (VAS) and Pittsburgh Sleep Quality Index (PSQI) were applied to all patients preoperatively and at one month postoperatively. Results : The postoperative PSQI total points and all the PSQI subscale points, the ODI and VAS scores were significantly reduced compared to the preoperative values. A positive correlation was determined between the preoperative ODI points and the PSQI total points and sleep duration, sleep latency and daytime functional loss subscale points. A positive correlation was also found between preoperative ODI points and VAS points. A positive correlation was determined between the preoperative VAS points and and the PSQI total points and sleep duration, and sleep latency subscale points. A negative correlation was determined between the postoperative ODI and the daytime functional loss subscale points. Conclusion : The results of the study showed that in patients with cervical disc hernia, sleep quality and daytime functionality were negatively affected by severity of pain that limited daily activities. Bringing the pain under control with surgical treatment was observed to increase sleep quality. It can be concluded that when planning treatment for these patients, it should be taken into consideration that there could be a sleep disorder in addition to the complaints and symptoms such as pain, hypoestesia and loss of strength.

A Novel Implantable Cerebrospinal Fluid Reservoir : A Pilot Study

  • Byun, Yoon Hwan;Gwak, Ho Shin;Kwon, Ji-Woong;Kim, Kwang Gi;Shin, Sang Hoon;Lee, Seung Hoon;Yoo, Heon
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권5호
    • /
    • pp.640-644
    • /
    • 2018
  • Objective : The purpose of this pilot study was to examine the safety and function of the newly developed cerebrospinal fluid (CSF) reservoir called the V-Port. Methods : The newly developed V-Port consists of a non-collapsible reservoir outlined with a titanium cage and a connector for the ventricular catheter to be assembled. It is designed to be better palpated and more durable to multiple punctures than the Ommaya reservoir. A total of nine patients diagnosed with leptomeningeal carcinomatosis were selected for V-Port insertion. Each patient was followed up for evaluation for a month after the operation. Results : The average operation time for V-Port insertion was 42 minutes and the average incision size was 6.6 cm. The surgical technique of V-Port insertion was found to be intuitive by all neurosurgeons who participated in the pilot study. There was no obstruction or leakage of the V-Port during intrathecal chemotherapy or CSF drainage. Also, there were no complications including post-operative intracerebral hemorrhage, infection and skin problems related to the V-Port. Conclusion : V-Port is a safe and an easy to use implantable CSF reservoir that addresses problems of other implantable CSF reservoirs. Further multicenter clinical trial is needed to prove the safety and the function of the V-Port.

정맥 주입한 Catecholamine이 흰쥐의 기초상태시 위산, Gastrin 및 Secretin 분비에 미치는 영향 (Effects of Intravenous Catecholamine on Gastric Acid, Gastrin and Secretin Secretion in Basal State of the Rat)

  • 김명석;심상수;김미혜;최현
    • The Korean Journal of Physiology
    • /
    • 제22권2호
    • /
    • pp.179-187
    • /
    • 1988
  • This study was conducted to investigate the effects of epinephrine and norepinephrine on basal gastric acid secretion and plasma gastrin and secretin concentration in the conscious rat. One hundred and eighty-four albino rats with gastric cannula were used after 18 hours or more of fast, with water ad libitum. In a restraint cage for collection of gastric juice, physiological saline (0.9% NaCl) was continuously infused into the jugular vein through a catheter for one hour at a rate of 1 ml/hr (control period). Immediately after the control period, epinephrine (1, 2, 4, 8 and $16{\mu}g/ml/hr)$, norepinephrine (1, 2, 4, 8 and $16{\mu}g/ml/hr)$ or physiological saline (1 ml/hr) was infused for another one hour. Gastric juice was collected at one hour interval for two hours infusion period. Adrenergic antagonists, phentolamine and propranolol were injected into the jugular vein 5 min prior to the infusion of epinephrine or norepinephrine at a dose of 0.2 mg/0.1 ml. Blood was sampled from the jugular vein for the radioimmunoassay of plasma gastrin and secretin after the collection of gastric juice. The results were as follows: 1) Both epinephrine and norephinephrine significantly increased gastric acid output in a dosedependent manner. 2) The effects of epinephrine and norepinephrine on the gastric acid secretion were antagonized by the pretreatment with phentolamine and propranolol. 3) Plasma gastrin and secretin concentrations were not significantly affected by the intravenous infusion of epinephrine and norepinephrine. It can be inferred from the above results that epinephrine and norepinephrine facilitate gastric acid secretion in conscious rats and the mechanism of which is attributed to ${\alpha}\;and\;{\beta}$ adrenergic receptors rather than gastrin and secretin.

  • PDF

Single-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation for Simple and Low Cost Stand-Alone Renewable Energy Utilizations Part II : Simulation and Experimental Results

  • Ahmed, Tarek;Noro, Osamu;Soshin, Koji;Sato, Shinji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권1호
    • /
    • pp.27-34
    • /
    • 2003
  • In this paper, the power conditioner composed of the stand-alone single-phase squirrel cage rotor type self-excited induction generator (SEIG) driven by prime movers such as a wind turbine and a micro gas turbine (MGT) is presented by using the steady-state circuit analysis based on the two nodal admittance approaches using the per-unit frequency in addition to a new state variable defined by the per-unit slip frequency along with its performance evaluations for the stand-alone energy utilizations. The stande-alone single-phase SEIG operating performances in unregulated voltage control loop are then evaluated on line under the conditions of the speed change transients of the prime mover and the stand-alone electrical passive load power variations with the simple theoretical analysis and the efficient computation processing procedures described in the part I of this paper. In addition, a feasuible PI controlled feedback closed-loop voltage regulation scheme of the stande-alone single-phase SEIG is designed on the basis of the static VAR compensate. (SVC) and discussed in experiment for the promising stand-alone power conditioner. The experimental operating performance results are illustrated and give good agreements with the simulation ones. The simulation and experimental results of the stand-alone single-phase SEIG with the simple SVC controller for its stabilized voltage regulation prove the practical effectiveness of the additional SVC control loop scheme including the PI controller with fast response characteristics and steady-sate performance improvements.

Drosophila auraria 의 반문다형현상의 유전학적분석 (Genetic Analysis of the Polymorphism of Color Pattern in Drosophila auraria)

  • 이택준
    • 한국동물학회지
    • /
    • 제7권2호
    • /
    • pp.41-47
    • /
    • 1964
  • D.auraria is a species belonging to the D.melanogaster group, and this species was divided into 3 races(A, B and C race ) by morphoogical difference of the genitals . Korean populations of D.auraria A race are polymorphic with respect to the pigmentation of the abdominal tergites. The female shows two forms of color pattern, dark and light, on the sixth to the ninth tergites, and the male has no distinction shown by the female. Crossing experiments in the laboratory have shown that the difference between these color forms is due to a single pair of allelic genes located on an autosome. In natural populations, the light forms of females are always commoner than the dark one. The number of the light form increases relatively in southern localities and decreases relatively in northern localities. Furthermore, the number of the light form increases relatively in summer and decreases relatively in fall and spring. By genetic analyses of these wild flies, the relation, d/d>d/D>D/D has been disclosed as regards the relative frequencies of the genotypes in natural populations. Three experimental populations have been set up in the laboratory. Homozygous dark forms and homozygous light forms were mixed together and cultured in population cage at the temperature of 25 $^{\circ}C$. Approximately one year later, the frequencies of the light and the dark forms reached an equilibrium , the light one being usually more frequent than the dark one. This indicates that the heterozygous dark form possesses the highest adaptive value, the homozygous light being intermediate and the homozygous dark lowest. In number of adults hached, the homozygous light form was superior to the heterozygous dark form and the homozygous dark form, but the differences are scarcely significant.

  • PDF

Stator Current Processing-Based Technique for Bearing Damage Detection in Induction Motors

  • Hong, Won-Pyo;Yoon, Chung-Sup;Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1439-1444
    • /
    • 2005
  • Induction motors are the most commonly used electrical drives because they are rugged, mechanically simple, adaptable to widely different operating conditions, and simple to control. The most common faults in squirrel-cage induction motors are bearing, stator and rotor faults. Surveys conducted by the IEEE and EPRI show that the most common fault in induction motor is bearing failure (${\sim}$40% of failure). Thence, this paper addresses experimental results for diagnosing faults with different rolling element bearing damage via motor current spectral analysis. Rolling element bearings generally consist of two rings, an inner and outer, between which a set of balls or rollers rotate in raceways. We set the experimental test bed to detect the rolling-element bearing misalignment of 3 type induction motors with normal condition bearing system, shaft deflection system by external force and a hole drilled through the outer race of the shaft end bearing of the four pole test motor. This paper takes the initial step of investigating the efficacy of current monitoring for bearing fault detection by incipient bearing failure. The failure modes are reviewed and the characteristics of bearing frequency associated with the physical construction of the bearings are defined. The effects on the stator current spectrum are described and related frequencies are also determined. This is an important result in the formulation of a fault detection scheme that monitors the stator currents. We utilized the FFT, Wavelet analysis and averaging signal pattern by inner product tool to analyze stator current components. The test results clearly illustrate that the stator signature can be used to identify the presence of a bearing fault.

  • PDF

Orius strigicollis의 증식 최적화 조건 탐색 (Determination of Optimum Conditions for Mass Rearing of Minute Pirate Bug, Orius strigicollis)

  • 송정흡;강상훈;강애숙;이광석;한원탁
    • 한국응용곤충학회지
    • /
    • 제40권2호
    • /
    • pp.111-115
    • /
    • 2001
  • 총채벌레류의 토착천적인 Orius strigicollis Poppius의 사육에 영향을 주는 부화율, 산란수 및 산란시기, 사육용기 당 암컷 성충의 밀도와 내적자연증가율을 광주기 16L:8D, 상대습도 $55\pm$10%, 온도 $25\pm$$2^{\circ}C$의 사육조건에서 조사하였다. 부화율과 알기간은 각각 88.5%, 5.7일이었다. 사육용기 당 산란수는 50-100개일 때에 우화율이 50.8%로 가장 좋았고, 새로 얻은 성충의 회수시기는 산란 후 17일이 적당하였다. 사육용기 당 암컷 성충의 밀도와 새로 얻은 성충의 수와의 관계는 Y= -10.7971n(X)+44.659($R^2$=0.7619)와 같았다. 사육실에서 대량으로 사육하는 경우 일세대 평균기간(T), 순번식율($R_{0}$ )과 내적자연증가율($r_{m}$ )은 각각 26.5일, 6.18과 0.0687이었다.

  • PDF