• 제목/요약/키워드: Cage

검색결과 1,288건 처리시간 0.058초

Expandable Cage for Cervical Spine Reconstruction

  • Zhang, Ho-Yeol;Thongtrangan, Issada;Le, Hoang;Park, Jon;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권6호
    • /
    • pp.435-441
    • /
    • 2005
  • Objective : Expandable cage used for spinal reconstruction after corpectomy has several advantages over nonexpendable cages. Here we present our clinical experience with the use of this cage after anterior column corpectomy with an average of one year follow up. Methods : Ten patients underwent expandable cage reconstruction of the anterior column after single-level or multilevel corpectomy for various cervical spinal disorders. Anterior plating with or without additional posterior instrumentation were performed in all patients. Functional outcomes, complications, and radiographic outcomes were determined. Results : There was no cage-related complication. Functionally, neurological examination revealed improvement in 7 of 10 patients and no patient had neurological deterioration after the surgery. Immediate stability was achieved and maintained throughout the period of follow-up. There was minimal subsidence [<2mm] noticeable in three of the cases that underwent a two-level corpectomy. Subsidence was noted in osteoporotic patients and patients undergoing multi-level corpectomies. Average pre-operative kyphotic angle was 9 degrees. This was corrected to an average of 5.4 degrees in lordosis postoperatively. Conclusion : In conclusion, expandable cages are safe and effective devices for vertebral body replacement after cervical corpectomy when used in combination with anterior plating with or without additional posterior stabilization. The advantages of using expandable cages include its ability to easily accommodate itself into the corpectomy defect, its ability to tightly purchase into the end plates after expansion and thus minimizing the potential for migration, and finally, its ability to correct kyphosis deformity via its in vivo expansion properties.

Variation in the reproductive rate of Trypoxylus dichotomus (Dymastinae: Sacarabaeidae: Coleoptera) by partition

  • Seo, Won-Jun;Park, Sang-Eun;Youn, Young-Nam
    • 농업과학연구
    • /
    • 제47권4호
    • /
    • pp.867-884
    • /
    • 2020
  • Trypoxylus dichotomus is highly utilized in the domestic insect industry and bred at many farms nationwide. Recently, the number of farmers has been increasing due to the expansion of its use in food and medicine. However, the traditional breeding methods have high economic costs, which include relatively large breeding boxes, large amounts of sawdust and a 2 to 1 ratio (or higher) of female to male. Thus, it is essential to develop a cost-effective breeding method. In this study, a breeding cage with a partition was designed and used to investigate the reproduction rate of T. dichotomus with only a single pair of male and female insect. According to the investigation, the average number of eggs laid in the un-partitioned breeding cage was 93.6, and 121.3 eggs were laid in the partitioned breeding cage. This result shows that T. dichotomus lays more eggs in the partitioned breeding cage rather than in the un-partitioned breeding cage. In addition, it was found that T. dichotomus tends to lay more eggs in compressed sawdust, which was harder than the common fermented sawdust. Through a wind-tunnel assay, it was shown that the ovipositing female recognizes the eggs and avoids them to disperse their eggs elsewhere. These results indicate that the partitioned breeding cage may increase the hardness of the sawdust, restrict the adult's movement and provide a new place for oviposition for the female, and therefore results in an increased reproduction rate with less cost.

Blood biochemical parameters and organ development of brown layers fed reduced dietary protein levels in two rearing systems

  • Viana, Eduardo de Faria;Mello, Heloisa Helena de Carvalho;Carvalho, Fabyola Barros;Cafe, Marcos Barcellos;Leandro, Nadja Susana Mogyca;Arnhold, Emmanuel;Stringhini, Jose Henrique
    • Animal Bioscience
    • /
    • 제35권3호
    • /
    • pp.444-452
    • /
    • 2022
  • Objective: An experiment was conducted to evaluate the effect of different levels of crude protein (CP) and two rearing systems (cage and floor), on blood parameters and digestive and reproductive organ development of brown laying hens. Methods: A total of 400 Hisex Brown laying hens between 30 and 45 weeks of age were distributed in a completely randomized design and a 2×4 factorial arrangement, with main effects including two rearing systems (cage and floor) and levels of CP (140, 150, 160, and 180 g/kg), in a total of eight treatments and five replicates of 10 birds each with initial body weight of 1,877 g (laying hen in cage) and 1,866 g (laying hens in floor). The parameters evaluated were plasma total protein, albumin, uric acid, total cholesterol, relative weights of oviduct, abdominal fat, liver, gizzard, crest and dewlap, length of small intestine and oviduct. Results: The blood parameters were similar in birds reared in cage and floor systems. The birds reared on the floor showed greater small intestine and oviduct weight (%) and lower liver and pancreas weight (%). A significant interaction was observed between factors for the relative gizzard, crest and dewlap weight, serum protein, uric acid, and total cholesterol (p<0.05). The diets with 140 g/kg CP resulted in lower serum protein and lower cholesterol in birds reared in floor system, while birds reared in cage system showed no effect of CP on both parameters. Birds reared in cage and fed with 140 and 150 g/kg CP presented lower uric acid. The group of birds reared in floor system fed 180 g/kg had greater uric acid. Conclusion: The dietary protein level can be reduced up to 140 g/kg for Hisex Brown hens (30 to 45 weeks of age) without an important effect on metabolic profile and organ development in both rearing systems.

다기능 반려동물 이동장 디자인 개발- 소형 반려견을 중심으로 - (Development of a multi-functional companion animal cage design - Focusing on small companion dogs -)

  • 최미화;이찬미;유나현;양혜림
    • 복식문화연구
    • /
    • 제31권2호
    • /
    • pp.262-276
    • /
    • 2023
  • This study aims to develop a multi-functional cage for dogs as a house to reduce their anxiety when they go out using cages. This study investigates the types and characteristics of cages and cage preference by surveying men and women in their 20s who use them. The cage product reviews are also analyzed. The research results are as follows: First, domestic dog cages are classified into crate, shoulder, cross (sling bag), backpack, carrier, and stroller types. The crate type is easy to clean and can be used as a house, but it is bulky and therefore inconvenient to carry when using public transportation. The shoulder type is a fabric material with good air permeability but has the disadvantage of being easily soiled. It can be used as a house and is light weight, making it convenient when using public transportation. Second, as a result of consumer research, respondents prefer the shoulder-type fabric over the crate-type plastic material. Third, from the shoulder-type product review, the shape stability, companion dogs' psychological safety, the wearability of companions, and management convenience are derived. Fourth, based on the survey results, a multi-functional cage is developed taking into account the companion dog, companion person, and functional factors.

단일 나사형 Cage를 이용한 후방 요추체간 융합술과 두개의 나사형 Cage를 이용한 PLIF의 생체 역학적 비교 (Posterior Lumbar Interbody Fusion Using Posterolateral Placement of A Single Cylindrical Threaded Cage and Two Regular Cages : A Biomechanical Study)

  • 박춘근;황장회;지철;권성오;성재훈;최승진;이상원;김문규;박성찬;조경석;박춘근;;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권7호
    • /
    • pp.883-890
    • /
    • 2001
  • Objectives : An in vitro biomechanical study of posterior lumbar interbody fusion(PLIF) with threaded cage using two different approaches was performed on eighteen functional spinal units of bovine lumbar spines. The purpose of this study was to compare the segmental stiffnesses among PLIF with one long posterolateral cage, PLIF with one long posterolateral cage and simultaneous facet joint fixation, and PLIF with two posterior cages. Methods : Eighteen bovine lumbar functional spinal units were divided into three groups. All specimens were tested intact and with cage insertion. Group 1(n=12) had a long threaded cage($15{\times}36mm$) inserted posterolaterally and oriented counter anterolaterally on the left side by posterior approach with left unilateral facetectomy. Group 2(n=6) had two regular length cages($15{\times}24mm$) inserted posteriorly with bilateral facetectomy. Six specimens from group 1 were then retested after unilateral facet joint screw fixation in neutral(group 3). Likewise, the other six specimens from group 1 were retested after fixation with a facet joint screw in an extended position(group 4). Nondestructive tests were performed in pure compression, flexion, extension, lateral bending, and torsion. Results : PLIF with a single cage, group 1, had a significantly higher stiffnesses than PLIF with two cages, group 2, in left and right torsion(p<0.05). Group 1 showed higher stiffness values than group 2 in pure compression, flexion, left and right bending but were not significantly different. Group 3 showed a significant increase in stiffness in comparison to group 1 for pure compression, extension, left bending and right torsion(p<0.05). For group 4, the stiffness significantly increased in comparison to group 1 for extension, flexion and right torsion(p<0.05). Although there was no significant difference between groups 3 and 4, group 4 had increased stiffness in extension, flexion, right bending and torsion. Conclusion : Posterior lumbar interbody fusion with a single long threaded cage inserted posterolaterally with unilateral facetectomy enables sufficient decompression while maintaining a majority of the posterior elements. In combination with a facet joint screw fixation, adequate postoperative stability can be achieved. We suggest that posterolateral insertion of a long threaded cage is biomechanically an ideal alternative to PLIF.

  • PDF

척추 결핵의 전방유합술시 Titanium Mesh Cage의 효과 (The Efficacy of Titanium Mesh Cage in Tuberculous Spondylitis Treated with Anterior Intervertebral Fusion)

  • 정주호;이상구;유찬종;한기수;김우경;김영보;박철완;이언
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권8호
    • /
    • pp.998-1003
    • /
    • 2001
  • Objective : The maintenance of the correction of kyphotic deformity is one of the difficult problem in tuberculous spondylitis after anterior debriment and fusion with tricortical bone graft. The goal of this study is to find out the efficacy of titanium mesh cage impacted with autogenous bone chip in tuberculous spondylitis treated with anterior intervertebral fusion. Materials and Method : Twelve patients were treated with anterior intervertebral fusion using titanium mesh cage for tuberculous spondylitis from January 1996 to June 1999. We analized the changes in the correction of kyphotic deformity, changes of ESR and CRP, fusion state and recurrence after anterior intervertebral fusion with titanium mesh cage. Results : Clinical symptoms were improved in all twelve patients without any neurologic complications. The mean kyphotic angle corrected was 7.3 degrees immediately after operation, but the loss of correction of kyphotic angle was 2.2 degrees after 3 months and 2.6 degrees after 6 months. We found that the loss of correction of kyphotic deformity occurred mainly within the first 3 months after surgery. Only one patient, suffered from acute hepatic failure after first operation and had an insufficient anti-tuberculous medication therapy, showed recurrence of tuberculous spondylitis after 6 months. The patient underwent a second operation with posterior fixation procedure with good outcome. The changes of ESR and CRP were not specifically important factor to reveal recurrence of tuberculosis of the spine in our series. Conclusion : The surgical procedure of tuberculous spondylitis using titanium mesh cage with bone chip seems to be an effective procedure to minimize loss of the correction of kyphotic deformity without any aggravating inflammatory change and recurrence with titanium mesh cage, when sufficient debridement and anti-tuberculous chemotherapy are achieved.

  • PDF

요추유합술에서 응력방패 현상 감소를 위한 케이지의 유한요소해석 : CFRP 케이지와 티타늄 케이지 비교 연구 (Finite Element Analysis of Instrumented Posterior Lumbar Interbody Fusion Cages for Reducing Stress Shielding Effects: Comparison of the CFRP cage and Titanium cage)

  • 강경탁;전흥재;김호중;염진섭;박경미;황인한;이광일
    • Composites Research
    • /
    • 제25권4호
    • /
    • pp.98-104
    • /
    • 2012
  • 본 논문에서는 척추체 간 유합용 케이지의 응력방패현상을 감소시키기 위하여 강성 차이에 대한 연구를 수행하였다. 최근 의료 임플란트 분야에서는 탄소섬유강화 폴리머를 이용하여 좋은 결과를 보여 왔다. 그러나 생체 역학적으로 이 재료에 대하여 요추체의 안정성과 골 이식재가 받는 응력에 관련한 연구는 없었다. 따라서 이전에 유효화한 요추체 (L2-L5) 비선형 유한 요소 모델을 이용하여 L4-L5 분절의 케이지의 강성 차이에 따른 효과를 알아보기 위하여 탄소섬유강화 폴리머와 티타늄 케이지를 이용한 후방 요추체 유합 모델을 만들었다. 자가골 보다 강성이 작은 탄소 섬유강화폴리머 케이지는 인접 분절의 하종판에 응력이 적게 걸리며, 골 이식재에 응력은 증가시켰다. 위의 결과로 탄소섬유강화 폴리머 케이지는 응력 방패 현상을 감소시킬 수 있을 뿐만 아니라 골 유합률을 증가시킬 수 있다.

The Effect of Hounsfield Unit Value with Conventional Computed Tomography and Intraoperative Distraction on Postoperative Intervertebral Height Reduction in Patients Following Stand-Alone Anterior Cervical Discectomy and Fusion

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung;Woo, Joon Bum;Kim, Young Ha
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권1호
    • /
    • pp.96-106
    • /
    • 2022
  • Objective : The most common complication of anterior cervical discectomy and fusion (ACDF) is cage subsidence and maintenance of disc height affects postoperative clinical outcomes. We considered cage subsidence as an inappropriate indicator for evaluating preservation of disc height. Thus, this study aimed to consider patients with complications such as reduced total disc height compared to that before surgery and evaluate the relevance of several factors before ACDF. Methods : We retrospectively reviewed the medical records of 40 patients who underwent stand-alone single-level ACDF using a polyetheretherketone (PEEK) cage at our institution between January 2012 and December 2018. Our study population comprised 19 male and 21 female patients aged 24-70 years. The minimum follow-up period was 1 year. Twenty-seven patients had preoperative bone mineral density (BMD) data on dual-energy X-ray absorptiometry. Clinical parameters included sex, age, body mass index, smoking history, and prior medical history. Radiologic parameters included the C2-7 cobb angle, segmental angle, sagittal vertical axis, disc height, and total intervertebral height (TIH) at the preoperative and postoperative periods. Cage decrement was defined as the reduction in TIH at the 6-month follow-up compared to preoperative TIH. To evaluate the bone quality, Hounsfield unit (HU) value was calculated in the axial and sagittal images of conventional computed tomography. Results : Lumbar BMD values and cervical HU values were significantly correlated (r=0.733, p<0.001). We divided the patients into two groups based on cage decrement, and 47.5% of the total patients were regarded as cage decrement. There were statistically significant differences in the parameters of measuring the HU value of the vertebra and intraoperative distraction between the two groups. Using these identified factors, we performed a receiver operating characteristic (ROC) curve analysis. Based on the ROC curve, the cut-off point was 530 at the HU value of the upper cortical and cancellous vertebrae (p=0.014; area under the curve [AUC], 0.727; sensitivity, 94.7%; specificity, 42.9%) and 22.41 at intraoperative distraction (p=0.017; AUC, 0.722; sensitivity, 85.7%; specificity, 57.9%). Using this value, we converted these parameters into a bifurcated variable and assessed the multinomial regression analysis to evaluate the risk factors for cage decrement in ACDF. Intraoperative distraction and HU value of the upper vertebral body were independent factors of postoperative subsidence. Conclusion : Insufficient intraoperative distraction and low HU value showed a strong relationship with postoperative intervertebral height reduction following single stand-alone PEEK cage ACDF.