• Title/Summary/Keyword: Cadavers

Search Result 196, Processing Time 0.025 seconds

Cordyceps bassiana and Production of Stromata in vitro Showing Beauveria Anamorph in Korea

  • Sung, Jae-Mo;Lee, Je-O;Humber Richard A.;Sung, Gi-Ho;Shrestha Bhushan
    • Mycobiology
    • /
    • v.34 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • A Cordyceps species was found with a Beauveria anamorph state on larval insect cadavers on Obong mountains in Gangwon Provinces, Republic of Korea. Cultures from discharged ascospores formed an anamorph identifiable as Beauveria bassiana. This teleomorph-anamorph connection was also confirmed by the in vitro production of fertile ascomata from conidial cultures with morphology like that of field-collected specimen. This is the first report of in vitro production of a teleomorph for any Beauveria species. The Cordyceps species has been conspecified as Cordyceps bassiana, a species described from China with B. bassiana anamorph.

The Present Situation and Problems of Human Anatomy in Oriental Medicine (한의학에서 사람해부학 교육의 현황과 문제점)

  • Kim, Soo-Myung
    • Journal of Haehwa Medicine
    • /
    • v.5 no.2
    • /
    • pp.445-448
    • /
    • 1997
  • The human anatomy is the fundamental subject which is required lots of time and efforts for medical students. But most of the oriental medical students think it little important field. And moreover they have no active attitudes in their courses. In order to improve the present situation, the results obtained from this study are as follows: 1. As a Law of Cadaver Conservation revised systemically, there's need to have enough cadavers for dissection. 2. The teaching method must be converted into the laboratory technique with the strengthening human anatomy. 3. With opening a neuroanatomy course in oriental medical curriculum, the quality of nervous system is expected to increase. 4. Under the current medical system, there's need to have discussion deeply about the histology course.

  • PDF

Interelationship Between the Concentration of Heavy Metals in Normal Korean Tissues (정상 한국인 장기조직중 중금속류의 상호관련성)

  • 이상기;유영찬;정규혁
    • YAKHAK HOEJI
    • /
    • v.43 no.5
    • /
    • pp.577-583
    • /
    • 1999
  • Concentrations of heavy metals, including As, Cd, Cr, Cu, Fe, Hg, Mn, Mo, Ni, Pb, Se, Si, Sn, V and Zn in the internal organs (liver, kidney, heart, lung, spleen, cerebrum and bone) of Korean obtained from 91 forensic medical autopsy cadavers, with an age range of 12-87 years, were determined by inductively coupled plasma atomic emission spectrometry. From the results, positive correlation with age was observed in the following cases : Cd in liver, kidney and cerebrum; Fe in cerebrum and bone; Pb in bone; v in lung. Copper in heart, Hg in bone and Mn in kidney correlated negatively with age. A significantly positive correlation between Se and Hg was only observed in heart. Significant correlation coefficients between Se and As were observed in liver, kidney, heart spleen and bone. The correlation between Cd and Zn was significant in liver and kidney, indicating that the distribution of Cd is similar to that of Zn in the liver and kidney.

  • PDF

Morphological Variations of the Celiac Plexus in Korean Cadavers (한국인(韓國人) 복강신경총(腹腔神經叢)의 해부학적(解剖學的) 변이(變異))

  • Hur, Chul-Ryung;Yoon, Duck-Mi;Chung, Min-Suck;Chung, In-Hyuk;Oh, Hung-Kun
    • The Korean Journal of Pain
    • /
    • v.2 no.2
    • /
    • pp.135-144
    • /
    • 1989
  • Celiac plexus block is recommended in patients with intractable upper abdominal cancer pain. The success rate of a celiac plexus block is variable among the authors. One of the causes of this is the anatomical variations of the celiac plexus. There has not been a study concerning anatomical observations of the celiac plexus in Korean cadavers. So, anatomical dissections were performed and observations were made of the celiac plexus and related structures in Korean cadavers. The results were as follows: 1) The subjects were 21 male bodies and 5 female bodies. The mean age at death was $69.9{\pm}15.5$ years (range 37~93). The mean height was $155.5{\pm}8.3\;cm$ (range 143~172). 2) The number of celiac ganglia ranged from 1~4. The mean numbers were $2.3{\pm}1.9$ in the right plexus and $1.9{\pm}0.8$ in the left, and the mean sizes were $18.9{\pm}7.7{\times}8.0{\pm}3.8\;mm^2$ and $18.5{\pm}8.3{\times}9.5{\pm}3.9\;mm^2$ respectively. 3) Celiac ganglia were most frequently located at the level of the upper third and middle third of L1 in both sides (65.5% in right, 64.0% in left). The vertical range of celiac ganglia ranged from 1 space, which is one third the height of one vertebral body, to 4 spaces. Mean vertical ranges were $1.5{\pm}0.6$ spaces in the right plexus and $1.6{\pm}0.7$ spaces in the left. The celiac ganglia located at the level of the upper third of L1 in the right and the lower third of L1 in the left side, had the largest vertical ranges respectively ($1.8{\pm}0.5$ spaces in right, $2.3{\pm}0.6$ spaces in left) 4) Right side celiac ganglia were located near the midline of the vertebrae compared to the left ones (mean 5.0 mm) The horizontal dimension was greater in the right ganglia ($24.2{\pm}9.2\;mm$) than in the left ganglia ($l8.8{\pm}7.0\;mm$). 5) There was no vertebral level difference between both celiac ganglia in most cases (60%). However, of the 40% of cases at different levels, in half of these (20%) the right ganglia were located higher than the left ganglia; and in the other 20%, this was reversed. 6) The origin sites of the celiac artery were most frequently in the upper third and middle third of L1 (61.6%). The celiac ganglia were usually located at the same level as the site of origin of the celiac artery (61.6% in right, 52.0% in left). 7) The vertebral level of the splanchnic nerves piercing the abdominal surface of the diaphragm was most frequently in the upper third and middle third of L1 (66.6% in right, 66.7% in left). 8) The level of the origin of diaphragmatic crura from the anterior surface of the vertebral bodies varied from the L1-L2 interspace to the L3-L4 interspace. Right crura most frequently originated at the level of the lower third of L2 to the upper third of L3 (57.6%), while left crura originated from the level of the L2-L3 interspace to the middle third of L3 (69.3%). From the above results, we realized that there were some anatomical variations of the celiac plexus and its relations to adjacent structures in Korean bodies. However, when the needle point is behind the anterior margin of the upper third of L1, it is possible to perform a successful retrocrural splanchnic nerve block.

  • PDF

Comparison of the Results between Cadaveric and Radiological Measurements of Calcaneus (종골의 사체 실측 결과와 방사선학적 측정 결과의 비교)

  • Kim, Jung-Han;Gwak, Heui-Chul;Lee, Chang-Rack;Jeong, Dong-Woo;Roh, Sang-Myung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.3
    • /
    • pp.102-106
    • /
    • 2015
  • Purpose: We wanted to compare the results between cadaveric and radiological measurements of calcaneus. Materials and Methods: Sixty three calcaneus of 33 cadavers donated between December 2012 and December 2014 were actually measured. Computed tomography (CT) images of 244 calcaneus in 122 patients of the same age group with cadavers were radiologically measured. Maximum length, maximum width, maximum height, $B{\ddot{o}}hler$ angle, Gissane angle, Fowler-Phillip angle, and tala-articular angle were measured. Results: In cadaveric measurement, the mean maximal height, length, and width were $41.8{\pm}3.3mm$, $73.3{\pm}3.4mm$, and $40.7{\pm}2.2mm$, respectively. In radiological measurement, the mean maximal height, length, and width were $38.5{\pm}4.3mm$, $74.0{\pm}5.7mm$, and $44.7{\pm}1.4mm$, respectively. In cadaveric measurement, the mean $B\ddot{o}hler$ angle, Gissane angle, Fowler-Phillip angle, and tala-articular angle were $32.1^{\circ}{\pm}6.2^{\circ}$, $110.8^{\circ}{\pm}8.1^{\circ}$, $55.8^{\circ}{\pm}6.8^{\circ}$, and $59.7^{\circ}{\pm}4.6^{\circ}$, respectively. In radiological measurement the mean $B{\ddot{o}}hler$ angle, Gissane angle, Fowler-Phillip angle, and tala-articular angle were $32.6^{\circ}{\pm}3.8^{\circ}$, $113.7^{\circ}{\pm}5.7^{\circ}$, $62.2^{\circ}{\pm}3.9^{\circ}$, and $61.6^{\circ}{\pm}6.3^{\circ}$, respectively. The mean maximal height was significantly higher in the cadaveric measurement group (p<0.001) and the mean maximal length and width were significantly higher in the radiologic measurement group (p<0.001, p<0.001). The mean Gissane angle, Fowler-Philip angle, and $B{\ddot{o}}hler$ angle were significantly higher in the CT group (p=0.001, p<0.001, p=0.016, respectively). There was no significant difference in the mean tala-articular angle (p=0.352). Conclusion: Significant differences in length parameters were observed between the cadaveric measurement group and the radiologic measurement group. However, no significant differences in angular measurements were observed between the two groups. The authors carefully conclude that radiological measurement values may be different from actual values in the calcaneus.

Anatomical Study of Superficial Peroneal Nerve Accessory Artery and Perforators in the Anterior Intermuscular Septum of Lower Leg Using Cadaveric Dissection (시체 해부를 통한 다리의 얕은종아리신경 동반동맥과 앞근육사이막에 존재하는 관통가지에 관한 해부학적 연구)

  • Kim, Jun Sik;Shin, Sang Ho;Choi, Tae Hyun;Lee, Kyung Suk;Kim, Nam Gyun
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.695-699
    • /
    • 2006
  • Purpose: In the 1990s, skin island flap supplied by the vascular axis of the sensitive superficial nerves had been introduced. For example, neurocutaneous flaps supplied by the vascular axis of the sural nerve and saphenous nerve have been used. But the flap supplied by the vascular axis of superficial peroneal nerve has not been used commonly. Because there have been few anatomical reports about the superficial peroneal nerve accessory artery(SPNAA), we could not apply the neurocutaneous flap supplied by SPNAA. The aim of this study is to investigate the anatomy of SPNAA, number and location of its perforators, and septocutaneous perforators from the anterior tibial artery in anterior intermuscular septum. Methods: So, we dissected a total of eight cadavers. Measurements were made of the positions of the dissected arteries and perforators from the head of the fibula. Results: In all cadavers the superior lateral peroneal artery was originated from the anterior tibial artery and contributed SPNAA. Arising from the anterior tibial artery an average of 5.63 cm inferior to the fibular head, it varied from 10 cm to 16 cm in length. SPNAA gave off an average of 4.38 perforators to supply lateral aspect. In one case the inferior lateral peroneal artery was present and arose from the anterior tibial artery 18 cm inferior to the fibular head. There were an average of 3.38 direct septocutaneous perforators from the anterior tibial artery. Conclusion: Septocutaneous perforators from SPNAA mainly exist from proximal 1/6 to 3/5 of lower leg. In the distal 1/3 of lower leg where the accessory artery was disappeared, exist mainly direct septocutaneous perforators from the anterior tibial artery. Our results can be helpful to applications of the neurocutaneous flap using SPNAA or fasciocutaneous flap based on direct septocutaneous perforators.

Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study (한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구)

  • Yoon, Yong-Cheol;Oh, Jong-Keon;Kim, Young-Woo;Kim, Hak Jun;Moon, Hong Joo;Kim, Nam-Ryeol
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

Anatomical Study for Vascular Distribution of the Perforator of Deep Inferior Epigastric Artery in Koreans (한국인에 있어 깊은아래배벽동맥(Deep Inferior Epigastric Artery)의 천공지(Perforator)에 관한 해부학적 연구)

  • Kim, Jee Hoon;Lee, Paik Kwon;Rhie, Jong Won;Kim, Deog Im;Han, Seung Ho
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.28-35
    • /
    • 2008
  • Purpose: The pedicle of transverse rectus abdominis myocutaneous(TRAM) flap and deep inferior epigastric arterial perforator flap is deep inferior epigastic artery (DIEA) and accurate anatomic knowledge about perforator of DIEA is very important for the elevation of these flap. The authors investigated a detailed vascular network of perforator of DIEA in Koreans. Methods: 24 fresh cadavers were studied. Among them, 15 were examined based on the plain X-ray examination for the distribution and location of perforator of DIEA. And 9 fresh cadavers were examined based on the 3-dimensional computed tomography(CT) study for the distance between ending point of perforator of DIEA and mother artery, the distance between most medial mother artery and midline, the distance between most lateral mother artery and midline, and the running type of perforators of DIEA. Results: Based on the plain X-ray examination, suitable(external diameter$${\geq_-}0.5mm$$) perforators of DIEA are located between the level of umbilicus and 8 cm below it. Based on the 3D-CT study, average distance between the ending point of perforator of DIEA and the mother artery is 30.26 mm on the left, 28.62 mm on the right, respectively. The average distance between most medial mother artery and midline is 17.13 mm on the left, 15.76 mm on the right, respectively. The average distance between most lateral mother artery and midline is 56.31 mm on the left, 50.90 mm on the right, respectively. The main running course of suitable perforators of DIEA is type a, which is a direct musculocutaneous perforator vessel from main vascular axis passing outward to join the subdermal plexus, directly. Conclusion: 3-dimensional computed tomography study as well as plain X-ray examination provided more accurate and detail informations about perforators of DIEA in Koreans. These informations will help us understand the detailed vascular anatomy and operation with ease and safe in the lower abdomen of Koreans.

B-mode ultrasound images of the carotid artery wall: correlation of ultrasound with histological measurements

  • Gamble G.;Beaumont B.;Smith H.;Zorn J.;Sanders G.;Merrilees M.;MacMahon S.;Sharpe N.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02b
    • /
    • pp.169-179
    • /
    • 1994
  • B-mode ultrasound is being used to assess carotid atherosclerosis in epidemiological studies and clinical trials. Recently the interpretation of measurements made from ultrasound images has been questioned. This study examines the anatomical correlates of B-mode ultrasound of carotid arteries in vitro and in situ in cadavers. Twenty-seven segments of human carotid artery were collected at autopsy. pressure perfusion fixed in buffered 2.5% gluteraldehyde and 4% paraformaldehyde and imaged using an ATL UM-8 (10 MHz single crystal mechanical probe). Each artery was then frozen, sectioned and stained with van Gieson or elastin van Gieson. The thickness of the intima. media and adventitia were measured 'to an accuracy of 0.01 mm from histological sections using a calibrated eye graticule on a light microscope. Shrinkage artifact induced by histological preparation was determined to be 7.8%. Digitised ultra sound images of the artery wall were analysed off-line. The distance from the leading edge of the first interface ($LE_{1}$) to the leading edge of the second interface ($LE_2$) was measured using a dedicated programme. $LE_{1}$-$LE_{2}$ measurements were correlated against histological measurements corrected for shrinkage. Mean values for the far wall were: ultra sound $LE_{1}$-$LE_{2}$ (0.97 mm, S.D. 0.26), total wall thickness (1.05 mm, S.D. 0.37), adventitia (0.35 mm, S.D. 0.16), media (0.61 mm, S.D. 0.18). intima (0.09 mm, S.D. 0.13). Ultrasound measurements corresponded best with total wall thickness, rather than elastin or the intima-media complex. Excision of part of the intima plus media or removal of the adventitia resulted in a corresponding decrease in the $LE_{1}$-$LE_{2}$ distance of the B-mode image. Furthermore. increased wall thickness due to intimal atherosclerotic thickening correlated well with $LE_{1}$-$LE_{2}$ distance of the B-mode images. B-mode images obtained from the carotid arteries in situ in four cadavers also corresponded best with total wall thickness measured from histological sections and not with the thickness of the intima plus media. In conclusion, the $LE_{1}$-$LE_{2}$ distance measured on B-mode images of the carotid artery best represents total wall thickness of intima plus media plus adventitia and not intima plus media alone.

  • PDF

Anatomic Study of the Vessels of the Digital Nerves in the Fingers (손가락 신경의 혈관 구조에 대한 해부학적 연구)

  • Lee, Joo Chul;Choi, Hwan Jun;Kim, Jun Hyuk;Lee, Young Man;Nam, Doo Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.2
    • /
    • pp.149-152
    • /
    • 2012
  • Purpose: The vessels of peripheral nerves have been extensively studied since Breidenbach used vascularizd nerve grafts. Tayor and Pinel studied the course and distribution of the vessels of peripheral nerves. However, the vessels of digital nerves are still not well known. The objective of this study was to prove vessels of digital nerves and to investigate the pathway of that. Materials and Methods: 36 patients and 2 fresh human cadavers were studied under the microscope and histologic sections under the light microscope.. Results: We found that digital nerves had own arterioles and venules as well as peripheral nerves. This small vessels of digital nerves paralleled the digital nerves or run in a spiral. Digital nerves were abundantly vascularized throught their length by a succession of vessels and by their repeated divisions and anastomoses. Conclusion: The clinical implications of this results can be discussed in relation to the dissection of nerves, the possibility of vasculized nerve grafts.

  • PDF