• Title/Summary/Keyword: Cad1-3

Search Result 869, Processing Time 0.03 seconds

Post-Traumatic Stress Disorder Symptoms and Quality of Life of Patients with Coronary Artery Disease (관상동맥질환자의 외상 후 스트레스장애 증상과 삶의 질)

  • Lee, Seung Ah;Kang, Jiyeon
    • Journal of Korean Critical Care Nursing
    • /
    • v.12 no.1
    • /
    • pp.82-93
    • /
    • 2019
  • Purpose : The purpose of this study was to investigate the degree of post-traumatic stress disorder (PTSD) symptoms and the effect of PTSD on quality of life (QoL) among coronary artery disease (CAD) patients. Methods: The participants were 135 CAD patients who visited outpatient clinics in a university hospital in B city of Korea. Their PTSD symptoms and QoL were measured by structured questionnaires and analyzed with multiple hierarchical regression analysis. Results: Among the 135 participants, 20.7% were classified as moderate risk, and 3.7% as high risk for PTSD. PTSD symptoms were significantly higher in participants who were diagnosed with CAD within 6 months (t=26.02, p<.001). The physical component of health-related QoL was influenced by gender (${\beta}=-.25$, p =.003), recurrence of CAD (${\beta}=.21$, p =.008), and PTSD symptoms (${\beta}=-.33$, p <.001). The mental component of health-related QoL was influenced by religion (${\beta}=-.17$, p =.044), body mass index (${\beta}=.17$, p =.033), and PTSD symptoms (${\beta}=-.37$, p <.001). Conclusion: Patients who had had a CAD diagnosis for less than 6 months were found to be vulnerable to PTSD, and PTSD was found to have a negative impact on the physical and mental components of their QoL. It is necessary to develop an intervention program for the effective prevention and management of PTSD symptoms in patients with CAD.

Effect of drill radius setting on prosthesis machining (드릴 반경 설정이 보철물 가공에 미치는 영향)

  • Kim, Chong-Myeong;Kim, So-Ri;Cho, Mi-hyang
    • Journal of Technologic Dentistry
    • /
    • v.40 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the trueness and fitness of machined prostheses according to drill radius setting in CAD software. Methods: For this study, standard abutment were replicated in Type IV stone. The stone abutment were scanned using a dental scanner. The CAD design software was designed using scanned abutment data. When designing, the drill radius was set to 0.3 mm and 0 mm, respectively, and saved. The saved design data was milled using a milling machine (n=13). The inner surface of the milled crown was scanned. The trueness and fitness were measured using the inner scan data of prostheses. Independent t-tests were performed to identify significant differences in each data. Results: Trueness values of the data saved with 0.3 mm and 0 mm drill radius were $18.9{\pm}2.3{\mu}m$ and $19.1{\pm}0.9{\mu}m$, respectively. There was no statistically significant difference between the groups. Fitness values of the data saved with 0.3 mm and 0 mm drill radius were $65.5{\pm}0.8{\mu}m$ and $33.8{\pm}1.0{\mu}m$, respectively. There was a statistically significant difference between the groups (p<.05). Conclusion : Setting the drill radius is important to produce clinically good fit prostheses.

MARGINAL AND INTERNAL FIT OF CAD/CAM-MANUFACTURED CERAMIC INLAY (CAD/CAM으로 제작된 세라믹 인레이의 변연 및 내면 적합성)

  • Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.618-629
    • /
    • 1998
  • CAD/CAM-fabricated ceramic restorations nowadays are used as alternatives of amlagam and posterior composite resin restorations, especially in the cases of inlay restorations. But the reported results on marginal and internal fit of CAD/CAM-fabricated ceramic inlay have showed considerable difference. In this study, to evaluate the marginal and internal fit of CEREC2-fabricated ceramic inlay restoration and to compare with the fit of gold inlay and amalgam restoration, standardized Class II MO cavities were prepared in forty extracted caries-free human premolars. The teeth with prepared cavities were divided into 4 groups of ten teeth each. In group 1, CEREC2-fabricated ceramic inlays were treated with Scotchbond Multi-Purpose Plus(SMP plus) and cemented with Scotchbond Resin Cement. In group 2, casted gold inlays were cemented in the same method as in group 1. In group 3, casted gold inlays were cemented with zinc-phosphate cement. And in group 4, the prepared cavities were restored with amalgam. Restored teeth were thermocycled, stored in 1% methylene blue for 24 hours, and sectioned faciolingually and mesiodistally using EXAKT. Sectioned surfaces were observed with stereomicroscope and the gaps were measured at 9 points of mesiodistally sectioned surface and 7 points of faciolingually sectioned surface. The measured data were treated by Kruskal-Wallis one way ANOVA and Student-Newman-Keuls test. 1. The differences among measured gaps at each points were statistically significant for 4 experimental groups (P<0.05). 2. There were statistically significant differences in the measured gaps at each points between group 1 and group 2, group 1 and group 3, group 1 and group 4, group 2 and group 4, and group 3 and group 4 (P<0.05). 3. There were not statistically significant differences in the measured gaps at each points between group 2 and group 3 (P>0.05). 4. In the cases of inlay restorations(group 1, group 2, group 3), the gaps at internal line angle(distopulpal, axiogingival, faciopulpal, linguopulpal line angle) had a tendency to increase. In the cases of amalgam restorations(group 4), the gaps at occlusal margin, gingival margin and axiogingival line angle were greater than those at the other parts of cavities. 5. In CEREC2-fabricated ceramic inlays which were treated with Scotchbond Multi-Purpose Plus and cemented with Scotchbond Resin Cement, the mean gaps were $111{\mu}m$ at cavity margins, $168{\mu}m$ at vertical walls of cavities, $225{\mu}m$ at internal line angles and $123{\mu}m$ at cavity floors.

  • PDF

Current Orthodontic Treatment using CAD/CAM technology: from orthodontic diagnosis to indirect bonding procedure (임상가를 위한 특집 2 - CAD/CAM 기술을 활용한 최신 교정치료 - 교정진단에서 간접부착술식까지)

  • Cha, Jung-Yul
    • The Journal of the Korean dental association
    • /
    • v.52 no.1
    • /
    • pp.17-26
    • /
    • 2014
  • Computerized 3D virtual dental models are currently available, and their use has started to improve treatment outcomes. The accuracy of digital models has been demonstrated by many studies and various intra-oral scanners are innovated for short scanning time and high precision. Recently, a digital model was combined with a high technology computer-driven system, which was developed for the application of a digital set-up and indirect bonding of lingual attachments. In this section, virtual treatment planning using a virtual set-up program is be introduced, and the clinical applications and accuracy of computer-generated indirect bonding are discussed.

A Study on the Possibility of Pattern Design Using CAD System (With concentration on the change of coat basic pattern) (CAD System을 이용한 패턴디자인설계 활용가능성에 관한 연구(I)-Coat 원형을 중심으로-)

  • 김옥경
    • Journal of the Korean Society of Costume
    • /
    • v.20
    • /
    • pp.49-62
    • /
    • 1993
  • The purpose of this research was to utilize of Pattern Design System(P.D.S) by using AM-300 The conclusion were like these : 1. A coat of basic pattern was selected by design sketch. 2. The basic pattern was input into computer by digitizing. 3. The basic pattern was change into designed shape by using various skills. This system were enabled to draw straight lines, curves, delete lines, sections of lines, extend lines, cut pattern into sections, measure line or section reproduce whole pattern shape of section, rotate and mirror pattern and complete patterns. 4. Automatic grading of finished master pattern have been developed by creation and modification of grading rules of basic pattern. 5. Production pattern added seam allowance, not-ches was generated by P.D.S menu option. 6. Finished pattern design was plotted out 100% and 20% size by AM-300 Plotter. This results will be the basic materials to develop the CAD SYSTEM if some problems were improve. Furthermore, the utilization of P.D.S is expected to be developing in pattern making process.

  • PDF

Rapid Prototyping System을 위한 형상정보 변환절차

  • Lee, U-Jong;Lee, Yong-Han;Hong, Yu-Seok
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.18 no.1
    • /
    • pp.63-80
    • /
    • 1992
  • The concept of rapid prototyping intended for a significant reduction in cost and lead time becomes even more practical with the recent development of various equipments to make the concept concrete. For the purpose of real application of commercially available SLA(stereolithography apparatus), this paper is intended to develop the standard conversion procedure from CAD data to the input data for SLA. While the procedure presented in this paper is based on CAD system "CATIA" and SLA of 3D systems, Inc., which are being used in authors' company DAEWOO Motor Co., Ltd., the basic concept of this paper can be applied to any other CAD systems and machines of using stereolithography process. The algorithm presented in this paper is classified into two stages-node sampling and triangulation. First of all, point data are sampled through the node sampling procedure, and then these are triangulated so that the input data for SLA operation is finally generated. The suggested method is devised in a way to meet the input requirements of SLA and more importantly consume less computation time and generate less number of input data for SLA.

  • PDF

Development of CAM system for laser process (레이저 가공을 위한 CAM 시스템의 개발)

  • Paek, T.K.;Han, Y.H.;Kim, K.D.;Jung, C.
    • Journal of Welding and Joining
    • /
    • v.9 no.2
    • /
    • pp.11-19
    • /
    • 1991
  • 1. 16bit 개인용 컴퓨터인 IBM-PC/AT수준에서 레이저 가공을 위한 임의의 도형을 입력하여 DXF File로 출력하고, External명령인 AutoCAM을 추가하여 AutoCAM의 실행이 가능하였으며 AutoCAM의 종료후에는 다시 AutoCAD로 작업이 가능하다. 2. 개발한 AutoCAM은 AutoCAD Ver 2.6i로부터 Release 10까지의 DXF File을 읽어 Graphic 출력이 가능하다. 3. 가공 경로를 NC프로그램이 임의로 선정가능하면서, 가장 능률적인 가공작업이 수행될 수 있 도록 연속 또는 최인접 도형요소를 자동 선정하고 이의 조건에 따른 Auto Mode의 NC프로그램 생성이 가능하다. 4. 생성된 NC프로그램을 레이저 가공기에 전송하여 가공실험을 실시한 결과, 생성된 NC 프로 그램은 거의 수정하지 않아도 작동이 가능한 정도의 만족할 만한 결과를 얻었으므로 실용화에 큰 문제가 없는 것으로 사료된다. 이상과 같이 레이저 가공을 위한 CAD/CAM시스템은 초심자등의 이용상의 편리를 위하여 대화식으로 하였으며 사용된 언어도 Quick BASIC으로 자체 개발하 였으므로 앞으로 이 분야의 연구 및 실용화를 위한 기초자료로 활용될 수 있을 것으로 사료된다.

  • PDF

Considerations and clinical appliances of various abutments in implant prostheses (임플란트 보철 치료에서 지대주 선택시 고려사항과 임상적 적용)

  • Park, Sungwoo;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.191-197
    • /
    • 2016
  • In the past, restoration of implant crown, ready-made abutment produced by implant manufacturer could only be used. Using straight, angled abutment, there was a limit in adaptation multiple implants. Recently, with the development of implant and CAD/CAM technology, CAD/CAM customized abutment use has become possible which is different from the past when restoration was possible with only prefabricated abutment. Not only it makes emergence profile possible which is similar to natural teeth, but also it makes insertion path possible on CAD in multiple implant restorations. However, on anterior teeth which dental esthetics is very important, another restorations which are formed with natural colored gingiva area could be required. Titanium-based zirconia prostheses which have titanium connection and zirconia structure from 1mm above fixture platform are alternative. Therefore, the purpose of this review is to analyze the characteristics, advantages and disadvantages of the abutment which is used in multiple implant restorations, and to choose right abutment when clinical trials.

  • PDF

A Study on the Data Structure and Implementation Techniques for the Object Oriented Ship Structure Modeling (객체지향 선체모델링을 위한 모델의 자료구조 및 내부처리 기법에 관한 연구)

  • Seung-Wan Suh;Won-Soo Kang;Kyu-Yeul Lee;Kyu-Ock Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.3
    • /
    • pp.1-11
    • /
    • 1994
  • The development of "Ship structural CAD system" has been performed in CSDP(Computerized Ship Design and Production) project to support ship structural design works. The procedures and contents of current design practice concerning the ship structural design were analyzed. To generate design information required at each design stage using the ship structural CAD system, the computerized model was created. To represent and implement the model information, a data structure which represents design concept as well as shape information was proposed using the concept of the product model. To embody the computerized model the object-oriented techniques were established to represent requirements of real world.

  • PDF

Internal Defects Inspection of Die-cast Parts via the Comparison of X-ray CT Image and CAD Data (CAD 데이터 및 엑스레이 CT이미지 비교를 통한 다이캐스팅 부품의 내부 결함 검사방법)

  • Hong, Gyeong Taek;Shim, Jae Hong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.1
    • /
    • pp.27-34
    • /
    • 2018
  • Industrially, die-casting products are formed through casting, and so the methods to inspect the defects inside them are very restrictive. External inspection methods including visual inspection, sampling judgment, etc. enables researchers to inspect possible external defects, but x-ray inspection equipment has been generally used to inspect internal ones. Recently, they have been also applying three-dimensional internal inspections using CT equipment. However, they have their own limitations in applying to the use of industrial inspection due to limited detection size and long calculation time. To overcome the above problems, this paper has suggested a method to inspect internal defects by comparing the CAD data of the product to be inspected with the 3D data of the CT image. In this paper, we proposed a method for fast and accurate inspection in three dimensions by applying x-ray inspection to find internal defects in industrial parts such as aluminum die casting products. To show the effectiveness of the proposed method, a series of experiments have been carried out.