• Title/Summary/Keyword: Ca-test

Search Result 1,324, Processing Time 0.048 seconds

Analysis of CA Certification Performance Test Results and Improvement of CA Test Method for a Better Differentiation of Gas Removal Performances for Room Air Cleaners (공기청정기 CA 규격성능시험 결과 분석 및 가스시험 변별력 향상 방안연구)

  • Kim, Hak-Joon;Han, Bangwoo;Kim, Yong-Jin;Cha, Sung-Il
    • Particle and aerosol research
    • /
    • v.7 no.3
    • /
    • pp.87-97
    • /
    • 2011
  • In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4 times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

Assessment of Sensitivity of Photo-Chromosomal Assay in the Prediction of Photo-carcinogenicity (광염색체이상시험의 광발암성 예측능력에 대한 평가)

  • Hong Mi-Young;Kim Ji-Young;Lee Young Mi;Lee Michael
    • Toxicological Research
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 2005
  • Photo-mutagenic compounds have been known to alter skin cancer rates by acting as initiators or by affecting subsequent steps in carcinogenesis. The objectives of this study are to investigate the utility of photo-chromosomal aberration (photo-CA) assay for detecting photo-clastogens, and to evaluate its ability to predict rodent photocarcinogenicity. Photo-CA assay was performed with five test substances that demonstrated positive results in photo-carcinogenicity tests: 8-Methoxypsoralen (photoactive substance that forms DNA adducts in the presence of ultraviolet A irradiation), chlorpromazine (an aliphatic phenothiazine an alpha-adrenergic blocking agent), lomefloxacin (an antibiotic in a class of drugs called fluoroquinolones), anthracene (a tricyclic aromatic hydrocarbon a basic substance for production of anthraquinone, dyes, pigments, insecticides, wood preservatives and coating materials) and Retinoic acid (a retinoid compound closely related to vitamin A). For the best discrimination between the test substance-mediated genotoxicity and the undesirable genotoxicity caused by direct DNA absorption, a UV dose-response of the cells in the absence of the test substances was firstly analyzed. All 5 test substances showed a positive outcome in photo-CA assay, indicating that the photo-CA test is very sensitive to the photo-genotoxic effect of UV irradiation. With this limited data-set, an investigation into the predictive value of this photo-CA test for determining the photo-carcinogenicity showed that photo-CA assay has the high ability of a test to predict carcinogenicity. Therefore, the photo-CA test using mammalian cells seems to be a sensitive method to evaluate the photo-carcinogenic potential of new compounds.

Effect of Alloying Elements on Creep Behavior of Mg-Al Alloys (Mg-Al 합금의 크리프 거동에 미치는 합금원소의 영향)

  • Lim, Hyun-Kyu;Kim, Shae-K.;Kim, Do-Hyang
    • Journal of Korea Foundry Society
    • /
    • v.32 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • In this study, three magnesium alloys were investigated; those are 1.5wt.% CaO added AM80, 1.0wt.% CaO added AM60, and conventional MRI153 alloys. Test specimens of three alloys were prepared by re-melting and casting into steel mold with ingots and machining. The mechanical properties and the creep behavior at 150 degrees Celsius of these specimens were determined and their microstructures were characterized using OM and SEM. For the application to die-casting, fluidity test were carried out with spiral mold. Compared with 1.0wt.% CaO added AM60 alloy, 1.5wt.% CaO added AM80 alloy exhibited good creep properties in all test conditions. Moreover, CaO added alloys showed better creep properties than MRI153 alloy at lower load condition. It is proposed that 1.5wt.% CaO added AM80 alloy is useful to apply to power-train parts such as transmission case in vehicles.

Bioavailability and Digestibility of Organic Calcium Sources by Bone Health Index (뼈건강 지표를 이용한 유기태 칼슘 급원의 생체이용성 및 소화율)

  • Han, Jeong-Ho;Kim, Eun-Mi;Cheong, Man-Ki;Chee, Sung-Kew;Chee, Kew-Mahn
    • Journal of Nutrition and Health
    • /
    • v.43 no.1
    • /
    • pp.12-25
    • /
    • 2010
  • This study was carried out to evaluate the bioavailabilities and the digestibilities of oligopeptide chelated (peptide-Ca), anchovy bone (anchovy-Ca) and methionine hydroxyl analogue (MHA-Ca) calcium compared to those of calcium carbonate in rats. In exp1, $CaCO_3$, were added to the basal diet at level of 0, 30 and 60% calcium of the AIN-93G diet. In test groups, peptide-Ca, anchovy-Ca and MHA-Ca, were added to the basal diet to provide calcium at the level of 40% of AIN-93G. In exp1, the bioavailabilities were evaluated from the regression equation of the ratios of theological/ actual calcium intakes of each dietary treatment. In exp2, urine and feces was to evaluate the true- and apparent digestibility and apparent retention. In exp1, Ca-60% group had higher bone mineral density (BMD), bone mineral content (BMC) and bone breaking strength (BBS) than those of the other standard groups. The bone weight and ash content of the peptide-Ca and anchovy-Ca groups were significantly higher than those of the MHA-Ca. Bone calcium content were not significantly different from the test group. The bioavailability of the MHA-Ca group was shown higher BMD (71%), BS (38%) and BBS (27%) compared to another control group. But the regression coefficient for BMD, BS and BBS were lower compare with that of bone ash and BMC. In exp2, the true- and apparent digestibility of test groups were shown to over 90%. Peptide-Ca was not significantly different from other test group, but digestibility and retention were higher compare to other test groups. In conclusion, peptide-Ca, anchovy-Ca and MHA-Ca improved Ca bioavailability in the rats. The compounds were higher Ca digestibility compared with those of $CaCO_3$. It is assumed that difference of digestibility for test groups may be correlated to the bioavailability of test groups in BMD, BMC, BS, BBS and bone ash respectively.

Ignition resistance of CaO added Mg-3Al, Mg-6Al and Mg-9Al Eco-Mg alloys (CaO가 첨가된 Mg-3Al, Mg-6Al 및 Mg-9Al Eco-Mg 합금의 발화 저항성 평가)

  • Lee, Jin-Kyu;Kim, Shae-K.
    • Journal of Korea Foundry Society
    • /
    • v.31 no.2
    • /
    • pp.60-65
    • /
    • 2011
  • Molten magnesium alloys and magnesium products are easily oxidized and burned when they are exposed to high temperature for manufacturing process and by accident. In order to solve these problems, CaO addition in magnesium alloys has been developed. The ignition resistance of CaO added Mg-3Al, Mg-6Al, and Mg-9Al Eco-Mg alloys were investigated in comparison with those of magnesium alloys without CaO. The ignition resistance was examined by three methods : DTA, furnace chip ignition test, and torch ignition test. DTA was carried out for obtaining quantitative ignition temperature data with respect to specimen geometry and test environment; the furnace ignition test for burr and chip ignition temperature data; and the torch test for ignition temperature data for manufactured products. The ignition resistance of magnesium alloys under all conditions greatly increased by CaO addition.

Bioactivity of $CaO-P_2O_5-SiO_2$ Glasses ($CaO-P_2O_5-SiO_2$계 유리의 생체활성)

  • 조정식;김철영
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.6
    • /
    • pp.433-440
    • /
    • 1993
  • The bioactivity of glasses in the CaO-SiO2 system and CaO-P2O5-SiO2 system with less than 10mol% of P2O5 was investigated by in vitro test in simulated body flood(SBF). The formation of Ca.P film and hydroxyapatite on the surface of glasses after in vitro test was analysed by X-ray photoelectron spectoscopy (XPS), fourier transform infrared reflection spectroscopy (FT-IRRS), energy dispersive X-ray spectroscopy (EDS), and scanning electron microscopy (SEM) observation. In the early stage of Ca.P film formation after in vitro test for CaO-SiO2 and CaO-P2O5-SiO2 glasses, the rate of Ca.P film formation on the surface of the glasses was dependent of structural parameter (Y) evaluated from the glass composition. First, in the case of the glasses having Y value below 2, Ca.P film and SiO2-rich layer were formed simultaneously, and there were no differences of the rate of Ca.P film formation in terms of the Y values. Second, in the case of the glasses having Y value above 2, the SiO2-rich layer was formed, and then Ca.P.Si mixed layer was formed in the silica gel structure of the SiO2-rich layer, and finally the Ca.P film on the surface of SiO2-rich layer. The rate of Ca.P film formation delayed as the Y values increased. The rate of hydroxyapatite formation of glasses (the rate of transformation from Ca.P film to hydroxyapatite) seems to be propotional to the rate of Ca.P film formation and Y value. The rate of hydroxyapatite formation of glasses belonging to the second group was delayed as structural parameter increased, and the hydroxyapatite crystal showed spherical growth in the early reaction stage, and then showed silkworm-like linear growth as the reaction time increased.

  • PDF

Improvement of the Result Related to Tumor Marker Test Through the OCS QC Program (OCS QC 프로그램을 통한 건진 센터 종양검사의 결과보고 개선)

  • Back, Song-Ran;Kim, Sung-Ho;Yoo, So-Yeon;Kim, Nyun-Ok;Moon, Hyoung-Ho;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.185-188
    • /
    • 2009
  • Purpose: Standard of retests were discrepant and inconsistent due to inaccuracy and lack of standardization within normal range limit of tumor marker test. To enhance the standardization of retests set standard value below normal range and the Order Communication System Quality Control (OCS QC) program was put in place. This program enables managing the results within lower limit of normal range which were used for tumor marker test in Health Center. Materials and Methods: At present the tumor marker study for AFP, CEA, CA19-9, CA125, and PSA included outpatients in Asan Medical Center from February to March, 2009. The standard value was obtained by using the percentage of CV of Inter Assay according to the normal range of each tumor test. The results were confirmed by using the OCS QC program via formatted assessment of screening test such as test items, standard value and medical department. The number of out-of-range results within plus and minus 30 percents regarding the five primary items of tumor marker test was assessed. The next step was to obtain the number of AFP, CEA, and CA125 according to the ratio of comparison between prior and post test result, 60%, 50%, and 40% within normal range, respectively. In addition, set standard value below normal range. Results: The first screening test with percentage of sample number was resulted between 30%-40% and the second one was AFP 26.1%, CEA 18.9%, CA19-9 17.3%, CA125 18.7%, and PSA 21.0% obtained screening percentage of average 20 percents. The limited value of retest was AFP less than 5.0 and more than 10.0, CEA less than 1.0 and more than 3.0, CA19-9 less than 10.0 and more than 30.0, and PSA less than 1.0 and more than 2.0 to set and the number of retest was obtained by applying to the limited value of retest to screening percentage of average 20 percents For two months, the number of retest was AFP 0, CEA 15, CA19-9 3, CA125 2, and PSA 5. Conclusions: Through using the OCS QC program in establishing the standard of retest systemically, there appeared to be reduced discrepancy among the examiners and to be expected improvement in relation to the error of results.

  • PDF

Result Analysis according to Population Distribution Trends when Reagents are Changed (시약 변경 시 모집단 분포 추이에 따른 결과 분석)

  • Hye-Mi Park;Soo-Yeon Lim;Sun-Hee Yoo;Sun-Ho Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.55-61
    • /
    • 2023
  • Purpose In this study, the monthly population distribution was calculated for statistical verification of 10 tests (CA19-9, CA15-3, testosterone, PTH, calcitonin, AFP, CEA, CA72-4, PSA, estradiol) with changed reagents, and the trend of change By comparing and analyzing the results, we want to verify the accuracy of the results and improve the reliability of the test. Materials and Methods From June 2021 to February 2023, for the 10 items in which the reagent was changed, the monthly percentage and standard deviation index before and after the reagent change were compared, respectively. At this time, the reference value was arbitrarily set for the comparison group in consideration of the reference value of the test item, and the groups were subdivided and compared, and the standard deviation index allowed range was -2.0 or more and 2.0 or less. Results For CA19-9, CA15-3, AFP, CEA, and calcitonin 5 test items, the change in monthly ratio in all test sections before and after the reagent change was kept constant. On the other hand, for CA72-4, PSA, testosterone, PTH, and estradiol items, the standard deviation index exceeded the acceptable standard after changing the reagent. CA72-4 test items showed an increasing trend in standard deviation index in the test section exceeding the reference value. In the case of the PSA test item, the maintenance ratio of 0.04 ng/mL was significantly decreased after changing the reagent. The testosterone test item had a standard deviation index of -2.5 in the test section exceeding 10.1 ng/mL after changing the reagent, and the standard deviation index of the PTH test item was out of the acceptable range in all test sections. It was confirmed that the estradiol test item showed an overall increase in the result value. Conclusion Through this study, the continuity and accuracy of the test results could be verified. It is considered that the stability of the test can be secured by analyzing the factors affecting the test result and solving the cause for the test item whose standard deviation index is out of the acceptable standard.

  • PDF

Temperature Effect on the Retention Behavior of Sugars in Ion Exchange Chromatography (이온 교환 크로마토그래피에서 온도가 당의 체류 특성에 미치는 영향)

  • Kim, Jin-Il;Lee, Chong-Ho;Koo, Yoon-Mo
    • Korean Chemical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.722-727
    • /
    • 2005
  • Dow99Ca350 (Dowex monosphere 99Ca/350 separation resin), MFG-220, and Finex CS-10GC are ion-exchange resins, and primarily used to separate sugars, and all of these resins have poly styrene DVB backbone, and sulfonyl group. These resins are already used to separate sugars continuously at sugar industry at constant temperature. These resins are used in experiments for understanding temperature effect on retention or adsorption behavior. Using Dow99Ca350, swelling test, porosity test, pulse test, and frontal analysis at various temperatures were performed. In the cases of MFG-220, and Finex CS-10GC, the effect of temperature variation was verified by pulse test. The experimental results are shown that Dow99Ca350, MFG-220, and Finex CS-10GC, which are commercial resins for sugar separation, are stable to temperature variation because the maximum change of retention time of fructose, and glucose are 1.76, and 3.37% respectively.

A Study on Corrosion Resistance of CA2-Mixed Paste (CA2 혼입 페이스트의 부식저항성에 관한 연구)

  • Kim, Jae-Don;Jang, Il-Young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_2
    • /
    • pp.289-297
    • /
    • 2022
  • Deterioration in durability of structures due to the steel corrosion is difficult to determine whether or not corrosion is initiated and how much propagated, and moreover, repair and maintenance are not easy to deal with. Therefore, preventive treatments can be the best option to avoid the deterioration. Various methods for preventing corrosion of steel, such as electrochemical treatments, anti-corrosion agents and steel surface coatings, are being developed, but economic and environmental aspects make it difficult to apply them to in-situ field. Thus, the purpose of this study was to improve corrosion resistance by using CA-based clinker that are relatively simple and expected to be economically profitable Existing CA-based clinkers had problems such as flash setting and low strength development during the initial hydration process, but in order to solve this problem, CA clinker with low initial reactivity were used as binder in this study. The cement paste used in the experiments was replaced with CA2 clinker for 0%, 10%, 20%, and 30% in OPC. And the mixture used in the chloride binding test for the extraction of water-soluble chloride was intermixed with Cl- 0.5%, 1%, 2%, and 3% by weight of binder content. To evaluate characteristic of hydration heat evolution, calorimetry analysis was performed and simultaneously chloride binding capacity and acid neutralization capacity were carried out. The identification of hydration products with curing ages was verified by X-ray diffraction analysis. The free chloride extraction test showed that the chlorine ion holding ability improved in order OC 10 > OC 30 > OC 20 > OC 0 and the pH drop resistance test showed that the resistance capability in pH 12 was OC 0 > OA 10 > OA 20 > OA 30. The XRD analyses showed that AFm phase, which can affect the ability to hold chlorine ions, tended to increase when CA2 was mixed, and that in pH12 the content of calcium hydroxide (Ca(OH)2), which indicates pH-low resistance, decreased as CA2 was mixed