• Title/Summary/Keyword: CYCLE

Search Result 20,321, Processing Time 0.043 seconds

Analysis of Urban Water Cycle Considering Water Reuse Option (물재이용을 고려한 도시지역의 물순환 해석)

  • Lee, Ji-Ho;Pak, Ki-Jung;Yun, Jae-Young;Yoo, Chul-Sang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1925-1928
    • /
    • 2007
  • Water cycle analysis was performed for Gunja basin located in metropolitan Seoul using Aquacycle model in order to assess the problems of urban water cycle. From the water cycle analysis of Gunja basin, it was found that 75% of total rainfall occurred in the form of surface runoff, and groundwater recharge only accounted for about 7%. This suggests serious distortion of water cycle which can be attributed to urbanization. Feasibility analysis of reuse scenarios such as rainwater use and wastewater reuse was then performed to examine their influences on improving the water cycle. From the analysis of water reuse options, it was shown that imported water supply savings of 13% can be achieved through rainwater use, and water supply savings of 31% through wastewater reuse.

  • PDF

DEVELOPMENT AND VALIDATION OF A NUCLEAR FUEL CYCLE ANALYSIS TOOL: A FUTURE CODE

  • Kim, S.K.;Ko, W.I.;Lee, Yoon Hee
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.665-674
    • /
    • 2013
  • This paper presents the development and validation methods of the FUTURE (FUel cycle analysis Tool for nUcleaR Energy) code, which was developed for a dynamic material flow evaluation and economic analysis of the nuclear fuel cycle. This code enables an evaluation of a nuclear material flow and its economy for diverse nuclear fuel cycles based on a predictable scenario. The most notable virtue of this FUTURE code, which was developed using C# and MICROSOFT SQL DBMS, is that a program user can design a nuclear fuel cycle process easily using a standard process on the canvas screen through a drag-and-drop method. From the user's point of view, this code is very easy to use thanks to its high flexibility. In addition, the new code also enables the maintenance of data integrity by constructing a database environment of the results of the nuclear fuel cycle analyses.

LNG운반선의 증발기체 재액화 장치의 사이클 해석

  • Jin, Yeong-Uk
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.04a
    • /
    • pp.221-232
    • /
    • 2012
  • Cycle analysis has been performed to find out the optimum design point of the BOG re-liquefaction plant. The cycle state, defined by three cycle variables, was mainly described by the three cold temperatures of the three-pass heat exchanger, on which the constraints by the heat exchanger are imposed. The cycle states which are confined within a domain limited by the temperature constraints were the primary issue of this study. The BOG mass within the domain was analyzed first and then the cycle performance was related to the BOG mass afterwards, which enabled us to explain the observed behavior of the cycle performance under the temperature constraints by the heat exchanger. A good cycle performance could be ensured if the two cold Nitrogen temperatures of the three temperatures were placed close together near $-140^{\circ}C$ while the BOG temperature is kept far above enough, but not too far, from $-140^{\circ}C$ such that it does not interfere in their optimum temperature range.

  • PDF

Simulation Study on the Performance Improvement of a Transcritical Carbon Dioxide Cycle (초월임계 이산화탄소 사이클의 성능향상에 관한 시뮬레이션 연구)

  • 조홍현;김용찬;서국정
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.158-166
    • /
    • 2004
  • The performance of a heat pump using $CO_2$ is predicted and analyzed by using a cycle simulation model developed in this study. Cycle simulations are conducted by varying design parameters and operating conditions with the applications of advanced techniques to improve system performance. The applied systems in the simulations are internal heat exchanger, expander, and 2-stage compression with intercooling. As a result, the applications of advanced techniques improve the heating and cooling performances of the transcritical $CO_2$ cycle by 8∼26% and 20∼30%, respectively, over the basic cycle.

Investigation on Efficiency Improvement of the Nitrogen Expander Cycle : Natural Gas Liquefaction Process for LNG-FPSO (LNG-FPSO(Liquefied Natural Gas-Floating Production Storage and Offloading)용 질소 팽창 사이클의 효율 개선에 대한 연구)

  • Baek, Seung-Whan;Jeong, Sang-Kwon;Kim, Sun-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.442-447
    • /
    • 2010
  • FPSO (Floating Production Strorage and Offloading) method for LNG industry is efficient and facile compared to onshore NG (Natural Gas) treatment facility. Five simple natural gas liquefaction cycles for FPSO are presented and simulated in this paper. SMR (Single Mixed Refrigerant) cycle, SNE (Single Nitrogen Expander) cycle, DNE (Double Nitrogen Expander) cycle, PNE (Precooled Nitrogen Expander) cycle, and PDNE (Precooled Double Nitrogen Expander) cycle are compared. Simple analysis results in this paper show that precooling process and adding an expander in the liquefaction cycle is an effective way to increase liquefaction efficiency.

Safety Analyses of Process and Facility for the ACP Demonstration

  • You, Gil-Sung;Choung, Won-Myung;Ku, Jeong-Hoe;Cho, Il-Je;Kook, Dong-Hak;Lee, Eun-Pyo;Park, Seong-Won
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2005.05a
    • /
    • pp.293-294
    • /
    • 2005
  • The safety analyses and evaluation works on the process and facility for ACP demonstration have been performed. The several safety factors, such as the risk, environmental, radiation, structural, criticality, were analyzed. The analysis results confirmed the reliability of the safety on the ACP process and facility during normal and accident conditions.

  • PDF

A Study on Determination for An Economic Life-cycle of the K-1 Tank (K-1 전차의 경제 수명 결정에 관한 연구)

  • 문형선;김충영
    • Journal of the military operations research society of Korea
    • /
    • v.23 no.1
    • /
    • pp.138-150
    • /
    • 1997
  • The life-cycle of the K-1 tank has been 10 years simply applying that of the U.S. M-1 tank. Therefore, this paper is focused on determination of an economic life-cycle for the K-1 tanks. The current operation cost is adjusted by interest rate and the depreciation cost is applied in this study for more reliable estimation of the life-cycle cost. The Equivalent Annual Method is utilized and then various regression techniques are applied for deriving an effective economic life-cycle. The economic life-cycle of the K-1 tank results in 13 years in this study. considering 95% confidence interval, the life cycle of the K-1 tank is between 10.5 years and 15.5 years.

  • PDF

Studies on the cell cycle of saccharomyces cerevisiae by electron spin resonance spectroscopy (전자스핀공명스펙트럼에 의한 saccharomyces cerevisiae의 세포환 연구)

  • 임형순;강사욱
    • Korean Journal of Microbiology
    • /
    • v.26 no.1
    • /
    • pp.44-51
    • /
    • 1988
  • The intracellular free radicals produced at different stages of cell cycle of Saccharomyces cerevisiae ATCC 24858 were investigated by means of electron spin resonance(ESR) spectroscopy. The synchronized cells by repeated starvation and refeeding revealed different ESR spectral pattern compared to that of asynchronized cells. Each spectrum centered at g=2.005, which indicates free radicals. The relative spin concentration was maximat at the end of DNA increase. The variation of the relative spin concentration at each distinct stage of the cell cycle was evaluated in relation to ascorbate concentration, L-galactonolactone oxidase activity, and ascorbate oxidase activity. The highest activities of L-galactonolactone oxidase and ascorbate oxidase were detected just before and at the maximum of relative spin concentration, respectively. And ascorbate concentration fluctuated through each stage of cell cycle with the changes of relative spin concentration, L-galactonolactone oxidase activity, and ascorbate oxidase activity. Thus it is suggested that intracellular free radicals should be related to cell cycle, interacted with ascorbate, and may play an important role in the cell cycle of Saccharomyces cerevisiae.

  • PDF

A Thermodynamic Study on Exhaust Heated Gas Turbine Cycle (연소기 후치 가스터빈에 관한 열역학적 연구)

  • Park, J.K.;Ohu, S.C.;Yang, O.Y.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.6
    • /
    • pp.18-28
    • /
    • 1994
  • An exhaust-heated gas turbine cycle equipped with a waste heat recovery boiler and ammonia absorption-type refrigerator using waste heat is newly devised and analyzed. The general performance of this cycle is compared with that of the conventional gas turbine cycle. This cycle shows a potential high efficiency. When 1500K of gas turbine inlet temperature the efficiency is 53 percent as compared to 45 percent for a conventional combined cycle. Suction cooling of this cycle leads to improve the thermal efficiency and the specific output.

  • PDF

Case Study on the Life Cycle Assessment of the Packaged Bean-curd in Food Industry (식품산업에 있어서 포장두부의 전과정평가 사례연구)

  • Hwang, Tae-Yeon;Yoon, Sung-Yee
    • Korean Journal of Organic Agriculture
    • /
    • v.15 no.3
    • /
    • pp.277-290
    • /
    • 2007
  • This study has been analyzed an execution example of the life cycle assessment on the packaged bean-curd of P company, the first case of the regular life cycle assessment on the processed foods in Korea and considered on the significance and directions of the life cycle assessment on the foods. It is possible to divide the potential environmental impact through the life cycle of the bean-curd into six categories and analyze the environmental impact on the production, use and disposal phases of the product. The values of each environmental impact have been quantified from the strength of the potential impact fur the corresponding category of impact. In the future, it is expected that the result of the lift cycle assessment will be increasingly used fur many areas such as Climate Change Convention and ISO22000, etc. and it is required to promote a project to make database through the assessment on the individual corps or types of businesses for it from now on.

  • PDF