Kim Sung Min;Kim Sung Jae;Bae Ha Suk;Choi Byoung Cheol
Journal of the Korean Society for Precision Engineering
/
v.22
no.5
s.170
/
pp.197-204
/
2005
In this study, ground reaction force(GRF), absolute symmetry index(ASI) and coefficient of variation(CV) of fixed, single-axis and multi-axis prosthetic ankle assemblies were investigated to show the biomechanical evaluation for above knee amputees. In the experiments, 37 normal male volunteers, two male and two female AK amputees were tested with fixed, single-axis and multi-axis prosthetic ankle assembly. A gait analysis was carried out to derive the ratio of GRF to weight as the percentage of total stance phase for ten points. The results showed that fixed-axis ankle was superior to the other two ankle assemblies for the characteristic of forwarding and breaking forces. Multi-axis ankle was relatively superior to the other two ankle assemblies for gait balancing and movement of the center for mass. single-axis ankle was relatively superior to the other two ankle assemblies for CV and ASI of GRF.
Journal of Korean Academy of Oral and Maxillofacial Radiology
/
v.6
no.1
/
pp.27-31
/
1976
A study was performed to investigate the size of pharynegeal cavity and sexual differences between Korean adult male and female by introducing linear analysis of the lateral cephalogram. The radiograms were composed of 46 adult males aged 24.64 and 52 adult females aged 22.74 respectively. In order to study and measure the pharyngeal area the following skeletal landmarks were selected: S, N, A, Ptm, B, H, H', M, S' N, FH and CV, and the angle CV-FH was measured to provide a factor for correction of error resulting from improper head positioning of subjects, especially in the relative positions of A and H, while radiography. All points to be measured were projected at right angles to the Frankfort plane. For the purpose of measuring the anteroposterior dimensions of pharyngeal cavity the distances were measured in A-Ptm, A-S, S-Ptm and CV-H, and vertical measurements were made in SN-A, SN-PNS, SN-H' and M-H'. The obtained results were as follows: 1. The pharyngeal cavity is broader in the vertical than in the anteroposterior diameter in both sex and the maxium sexual differences were showed in the distances between SN and H', and minimal sexual differences in the distances between S and Ptm. 2. In general, the measurements of male were larger than those of female in the anteroposterior dimensions of pharyngeal cavity, but the distances bet-ween A and S, between CV and H showed significant sexual differences when evaluated statistically. 3. All of the measurements were larger in male than in female in vertical dimensions of pharyngeal cavity, and there were statistical significances of sexual differences in all variables.
This study aims at assessment of spatio-temporal distribution of demersal fish aggregations near the west coast of Jeju Island using hydroacoustic survey. A 200 kHz split beam transducer attached to a small towed body was used for all acoustic investigations. The received acoustic data were in situ acoustic target strength (TS, dB) for all pings and nautical area scattering coefficient(NASC, $m^2/mile^2$) for 0.1 mile along 12 acoustic transects. Demersal fish aggregations are distributed around the coastal slope having 20 to 30 m depth throughout all seasons. The concentration is higher during the summer season. With regard spatial distribution, higher demersal fish aggregations have been detected near the West coast of Shinchang and especially near Chagwi-do. Pelagic fish aggregations were higher to the south of Chagwi-do during the spring season. Additionally, standing stock of demersal fish aggregations from the NASC data, TS function, and length-weight function of dominant species was estimated as follows: 3.2 ton (CV 21.8%) in December 2006, 17.9 ton (CV 21.6%) in April 2007, 30.8 ton (CV 17.8%) in June 2007, and 22.5 ton (CV 24.2%) in October 2007. The application of hydroacoustic methods offers a new approach to understanding spatiotemporal structure and estimate the biomass of demersal fish aggregations in the coastal area. And the results can be made up limitations of qualitative analysis through net and diving for fisheries resources survey in coastal area.
Objectives : This study is to examine the effects of moxibustion at Junggeuk(CV3), Singwol(CV8) on women's urinary incontinence and quality of life. The study is a research based on the non-equivalent control group pretest-posttest design. Methods : The subjects of the study were 45 women who were using either of 2 health clinics located in Ulsan. They were sampled in accordance with predetermined standards and then divided into the experimental and control groups, respectively consisting of 22 and 23 members. In treating those women through moxibustion, this researcher applied 2 sheets of 'shingigu' to each of the women on 40 min, per time basis. This experiment was conducted 6 times in total for 2 weeks on every two day basis. Data from all of the measurements were statistically processed and analyzed using SPSS/WIN 12.0. Demographic characteristics of the subjects were examined and indicated in frequency and percentage. The homogeneity test of the two groups was conducted using $x^2$-test, Fisher's exact test, t-test and Mann-Whitney U Test. Hypotheses set for the study were verified through t-test and Mann-Whitney U Test. Results : The experimental group who take moxibustion will be lower in the severeness of urinary incontinence than the control group who do not was supported(p<0.001). 2. The experimental group who take moxibustion will be higher in score for life quality than the control group who do not was supported(U=42.00, p<0.001). Conclusions : These findings suggest that moxibustion can be an effective intervention for women having urinary incontinence because it treats the symptom with no adverse effect and it is non-invasive and easily applicable.
Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.
Kim, Hyun-Bok;Seo, Sang-Deok;Koo, Hui-Yeon;Seok, Young-Seek;Kim, Sun-Lim;Sung, Gyoo-Byung
Journal of Sericultural and Entomological Science
/
v.51
no.1
/
pp.20-29
/
2013
Countries of the world are competing for the collection and utilization of genetic resources, which is a resource of value-added industrialization. We are building database of silkworm and mulberry resources with morphological, genetic characteristics data etc. Moreover, recent bioactive compound has been receiving increasing attention. So we analyzed 1-deoxynojirimycin(1-DNJ) content as a this item in addition to the basic information using 363 strains(varieties) of mulberry genetic resources. They were grown under the same environment and conditions. Mulberry leaves were collected and then freeze-dried and powdered for 1-DNJ test. As a result, 1-DNJ mean content of 363 mulberry strains was $0.176{\pm}0.077%$, and the coefficient of variation (CV) was 43.5%. The variation between the strains was greatly severe. Among the tested strains, 'C1D89/29' was showed the highest content of 0.47%, whereas 'Pumbo 24' and 'Turkey E' were showed the lowest content of 0.05% respectively. The content of 1-DNJ of 16 mulberry varieties for silkworm rearing were compared. Average concentration was $0.17{\pm}0.04%$, and the coefficient of variation (CV) was 22.8%. Variation among cultivars was not significant. Finally we selected 1-DNJ high-containing 11 strains. They are as follows. 'C1D89/29', 'Hiihak', 'Jeokasibmunja', 'Gweonchil', 'Botongsibmunja', 'Jeokchuk', 'bulguksang', 'Geunsookgojo', 'Busanggeum', 'Guksang 20' and 'Taekwang' which are more than twice of the overall average content.
Kwon, Young Soon;Choi, Seong Youl;Kil, Mi Jung;You, Bong Sik;Jung, Jae A;Park, Sang Kun
Korean Journal of Agricultural Science
/
v.40
no.4
/
pp.297-303
/
2013
This study was carried out to examine the effect of Red LED (660 nm) and fluorescent lamp for night break (NB) treatments of each 3 hours (22:30-01:30), 4 hours (22:00-02:00) and 5 hours (21:30-:02:30) per day for 53 days on flower bud initiation and growth in Chrysanthemum cv. 'Baekma' and cv. 'Jinba'. The days to flower budding after short-day treatment in 'Baekma' was longer at fluorescent lamp 4 hr (21.0 days) and 5 hr (20.5 days) NB, and it was shorter at Red LED 3 hr (14.2 days). The days to flowering after short-day treatment in 'Baekma' was longer at fluorescent lamp 4 hr (54.0 days), 5 hr (53.5 days) NB, and Red LED 5 hr (53.3 days), and it was shortest at Red LED 3 hr (50.2 days) NB treatment among all treatments. The days to flower budding after short-day treatment of 'Jinba' was longer at fluorescent lamp 4 hr (20.6 days) and was shorter at Red LED 3 hr (14.1 days) among all treatments. Similarly, the days to flowering after short-day treatment of 'Jinba' was longer at fluorescent lamp 4 hr (55.3 days) and was shortest at Red LED 3 hr (50.2 days) among all treatments. Therefore, inhibition of flower bud initiation was the most effective under fluorescent lamp 4 hr treatment. The length of cut flower of 'Baekma' was increased by fluorescent lamp 4 hr, 5 hr, and Red LED 5 hr, but of 'Jinba' was longer at LED 4 hr and 5 hr treatment. The weight of cut flower of 'Baekma' was heaviest at fluorescent lamp 5 hr treatment and was at Red LED 5hr treatment for 'Jinba' even though there was not statistically significant difference between 'Baekma' and 'Jinba'. Consequently, under fluorescent lamp 4 hr for night break was the most effective on flower bud initiation, flowering inhibition and cut-flower characteristics in 'Baekma' and 'Jinba'.
We studies seed set in the interspecific F1 /backcross hybrids of Lilium species. In the interspecfic hybrid of L. longiflorum cv. Gelria with L.${\times}$ fomolongi cv. Raizan,93% fruit set was obtained by stigmatic pollination in comparison to 53% from cut-style pollination. Accordingly, the number of seed set resulting from stigmatic and cut-style pollination was 147 and 53, respectively. Pollination o( both stigmatic and cut-style pollination resulted in 47% fruit set in the hybrid of L. longiflorum cv. Lorina with L.${\times}$ fomolongi cv. Raizan. However, stigmatic pollination formed 413 seeds, whereas only 24 seeds were obtained by cut-style pollination in this cross. The hybrid of L.${\times}$ fomolongi cv. Raizan with L. longiflorum cv. Come set 40% fruit with a total of 43 seeds by stigmatic pollination. However, no fruit set was observed in cut-style pollination in this hybrid. Backcrossing the F1 hybrid by cut-style pollination of L. longiflorum cv. Lorina ${\times}$ Asiatic hybrid cv. Chicago with the latter parent led to 53% fruit set, and 109 embryos were obtained. Likewise, backcrossing following cut-style pollination of L. longiflorum cv. Lorina ${\times}$ Asiatic hybrid cv. Corsia with the latter parent formed 67% fruits and 107 embryos. However, in the remaining interspecific hybrids, cut-style pollination set no fruit.
Kim, Ju Yong;Kim, Bo Hyun;Kim, Hye Bin;Yook, Tae Han;Kim, Jong Uk
Journal of Acupuncture Research
/
v.33
no.4
/
pp.93-100
/
2016
Objectives : To find an acupuncture point where more exact Surface Electromyography(SEMG) measurement can be drown, through the study of measurement of orbicularis oris. Methods : Of healthy people from 19 to 40 years of age, who did not fall under exclusion criteria (22 males and 22 females), were selected as subjects, after relaxation for 10 minutes, and they were told how to pronounce 'O' and 'U' with their lips puckered. The SEMG figures were measured with attaching disposable electrode on acupuncture point of right-and-left Hwaryo(LI19) and 1 cun away from Seungjang(CV24) on both sides when the subjects pronounced 'O' and 'U'. Results : The average value was highest on left 1 cun away from Seungjang(CV24) in pronouncing 'O' and 'U', and the average SEMG value was higher in the order of right 1 cun away from Seungjang(CV24), right Hwaryo(LI19), left Hwaryo(LI19). Average of the lower orbicularis oris is statistically higher than that of the upper orbicularis oris, which has significant meaning. However, there was no significant difference when compared by pronunciation. Average of percentage mark of differences of right-and-left measured value of each pronunciation and each acupuncture point : Pronounced 'O' and the upper part of orbicularis oris: $16.76{\pm}11.29%$, pronounced 'O' and the lower part of orbicularis oris: $22.41{\pm}12.92%$, pronounced 'U' and the upper part of orbicularis oris: $17.10{\pm}9.89%$, pronounced 'U' and the lower part of orbicularis oris : $19.20{\pm}10.82%$. Conclusion : The difference of pronunciation will not affect the results in SEMG measurement. In addition, the average of the lower orbicularis oris is statistically and significantly higher than that of the upper orbicularis oris.
Backgrounds and purpose : The acupuncture of oriental medicine is very important in treatments. Until now it was been researched according to the meridian and qi xue(氣血) phenomenon of oriental medicine's theory. Acupuncture will show more objective index to observe the meridian. And then, I studied the effects on the thermal change of the Taeyon($L_9$) and Chungbu($L_1$) following acupuncture stimulation. Objective and Methods : This study was performed from December 1999 to February 2000 on 60 healthy students. The objective was divided into two groups, those are the control group A(N=30) that no acupuncture stimulation, the group B(N=30) of acupuncture stimulation on Taeyon($L_9$). First, in the control group A, I took a picture Taeyon($L_9$) Chungbu($L_1$) Taenung($P_7$) Chondol($CV_{22}$) area for 30 men without any stimulation with the Digital Infrared Thermograph Imaging(D.I.T.l.) and did same area, 10min after. Second, in the acupuncture stimulation group B, we took a picture Taeyon($L_9$) Chungbu($L_1$) Taenung($P_7$) Chondol($CV_{22}$) area for 30 men without any stimulation with the Digital Infrared Th - ermograph Imaging(D.I.T.I.), and then stimulate acupuncture on Taeyon($L_9$) and took a picture same area, 10min after. Results : 1. In healthy men, average skin temperture on Taeyon($L_9$) area was lower than Chungbu($L_1$) area about $3.0^{\circ}C$, in the Lt. Taeyon($L_9$) and Chungbu($L_1$) area was lower than Rt. Taeyon($L_9$) and Chungbu($L_1$) area. 2. In the acupuncture stimulation group B, the skin temperature of both side Taeyon($L_9$) area showed the increase or decrease significantly. But both Taenung($P_7$) area did not showed significantly. 3. In the acupuncture stimulation group B, the skin temperature of both side Chungbu($L_1$) area showed the increase or decrease significantly. But both Chondol($CV_{22}$) area did not showed significantly. 4. The thermal changes of the area which is a meridian point in the Lung Meridian of the acupuncture stimulation group on Taeyon($L_9$) different from other Meridian with significantly change. Conclusion : The acupuncture stimulation on Taeyon($L_9$) affected the thermal change of the area which is a meridian point, in the Lung Meridian. And then I could relate these results with the existence of the meridian and meridian point. Thus, continuous thermographic study will be needed for the existence of the meridian and meridian point.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.