• Title/Summary/Keyword: CV22

Search Result 286, Processing Time 0.032 seconds

A Study on The Assessment Method of Gait Analysis for Ankle Assembly Using Ground Reaction Force (지면반발력을 이용한 인공족관절의 보행평가 기법에 관한 연구)

  • Kim Sung Min;Kim Sung Jae;Bae Ha Suk;Choi Byoung Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.197-204
    • /
    • 2005
  • In this study, ground reaction force(GRF), absolute symmetry index(ASI) and coefficient of variation(CV) of fixed, single-axis and multi-axis prosthetic ankle assemblies were investigated to show the biomechanical evaluation for above knee amputees. In the experiments, 37 normal male volunteers, two male and two female AK amputees were tested with fixed, single-axis and multi-axis prosthetic ankle assembly. A gait analysis was carried out to derive the ratio of GRF to weight as the percentage of total stance phase for ten points. The results showed that fixed-axis ankle was superior to the other two ankle assemblies for the characteristic of forwarding and breaking forces. Multi-axis ankle was relatively superior to the other two ankle assemblies for gait balancing and movement of the center for mass. single-axis ankle was relatively superior to the other two ankle assemblies for CV and ASI of GRF.

A LATERAL CEPHALOMETRIC STUDY OF PHARYNGEAL CAVITY IN KOREAN ADULTS (한국인 성인의 인두강에 관한 X선학적 연구)

  • Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.6 no.1
    • /
    • pp.27-31
    • /
    • 1976
  • A study was performed to investigate the size of pharynegeal cavity and sexual differences between Korean adult male and female by introducing linear analysis of the lateral cephalogram. The radiograms were composed of 46 adult males aged 24.64 and 52 adult females aged 22.74 respectively. In order to study and measure the pharyngeal area the following skeletal landmarks were selected: S, N, A, Ptm, B, H, H', M, S' N, FH and CV, and the angle CV-FH was measured to provide a factor for correction of error resulting from improper head positioning of subjects, especially in the relative positions of A and H, while radiography. All points to be measured were projected at right angles to the Frankfort plane. For the purpose of measuring the anteroposterior dimensions of pharyngeal cavity the distances were measured in A-Ptm, A-S, S-Ptm and CV-H, and vertical measurements were made in SN-A, SN-PNS, SN-H' and M-H'. The obtained results were as follows: 1. The pharyngeal cavity is broader in the vertical than in the anteroposterior diameter in both sex and the maxium sexual differences were showed in the distances between SN and H', and minimal sexual differences in the distances between S and Ptm. 2. In general, the measurements of male were larger than those of female in the anteroposterior dimensions of pharyngeal cavity, but the distances bet-ween A and S, between CV and H showed significant sexual differences when evaluated statistically. 3. All of the measurements were larger in male than in female in vertical dimensions of pharyngeal cavity, and there were statistical significances of sexual differences in all variables.

  • PDF

Hydroacoustic Survey of Spatio-Temporal Distribution of Demersal Fish Aggregations Near the West Coast of Jeju Island, Korea (제주도 서쪽 연안에서 음향자원 조사를 이용한 저층 어군의 시.공간 분포)

  • Kang, Dong-Hyug;Im, Yang-Jae;Lee, Chang-Won;Yoo, Joon-Taek;Myoung, Jung-Goo
    • Ocean and Polar Research
    • /
    • v.30 no.2
    • /
    • pp.181-191
    • /
    • 2008
  • This study aims at assessment of spatio-temporal distribution of demersal fish aggregations near the west coast of Jeju Island using hydroacoustic survey. A 200 kHz split beam transducer attached to a small towed body was used for all acoustic investigations. The received acoustic data were in situ acoustic target strength (TS, dB) for all pings and nautical area scattering coefficient(NASC, $m^2/mile^2$) for 0.1 mile along 12 acoustic transects. Demersal fish aggregations are distributed around the coastal slope having 20 to 30 m depth throughout all seasons. The concentration is higher during the summer season. With regard spatial distribution, higher demersal fish aggregations have been detected near the West coast of Shinchang and especially near Chagwi-do. Pelagic fish aggregations were higher to the south of Chagwi-do during the spring season. Additionally, standing stock of demersal fish aggregations from the NASC data, TS function, and length-weight function of dominant species was estimated as follows: 3.2 ton (CV 21.8%) in December 2006, 17.9 ton (CV 21.6%) in April 2007, 30.8 ton (CV 17.8%) in June 2007, and 22.5 ton (CV 24.2%) in October 2007. The application of hydroacoustic methods offers a new approach to understanding spatiotemporal structure and estimate the biomass of demersal fish aggregations in the coastal area. And the results can be made up limitations of qualitative analysis through net and diving for fisheries resources survey in coastal area.

Effect of Moxibustion at Junggeuk(CV3), Singwol(CV8) on Women's Urinary Incontinence and Quality of Life (중극(中極), 신궐(神厥) 뜸요법이 여성의 요실금과 삶의 질에 미치는 효과)

  • Lee, Eun-Sook;Kim, Yi-Soon;Lee, Jeong-Won;Oh, Mi-Jung;Kim, Gyeong-Cheol
    • Korean Journal of Acupuncture
    • /
    • v.30 no.3
    • /
    • pp.193-200
    • /
    • 2013
  • Objectives : This study is to examine the effects of moxibustion at Junggeuk(CV3), Singwol(CV8) on women's urinary incontinence and quality of life. The study is a research based on the non-equivalent control group pretest-posttest design. Methods : The subjects of the study were 45 women who were using either of 2 health clinics located in Ulsan. They were sampled in accordance with predetermined standards and then divided into the experimental and control groups, respectively consisting of 22 and 23 members. In treating those women through moxibustion, this researcher applied 2 sheets of 'shingigu' to each of the women on 40 min, per time basis. This experiment was conducted 6 times in total for 2 weeks on every two day basis. Data from all of the measurements were statistically processed and analyzed using SPSS/WIN 12.0. Demographic characteristics of the subjects were examined and indicated in frequency and percentage. The homogeneity test of the two groups was conducted using $x^2$-test, Fisher's exact test, t-test and Mann-Whitney U Test. Hypotheses set for the study were verified through t-test and Mann-Whitney U Test. Results : The experimental group who take moxibustion will be lower in the severeness of urinary incontinence than the control group who do not was supported(p<0.001). 2. The experimental group who take moxibustion will be higher in score for life quality than the control group who do not was supported(U=42.00, p<0.001). Conclusions : These findings suggest that moxibustion can be an effective intervention for women having urinary incontinence because it treats the symptom with no adverse effect and it is non-invasive and easily applicable.

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF

Quantitative Analysis of 1-deoxynojirimycin in Mulberry Leaves (뽕나무 유전자원의 1-deoxynojirimycin 함량 변이)

  • Kim, Hyun-Bok;Seo, Sang-Deok;Koo, Hui-Yeon;Seok, Young-Seek;Kim, Sun-Lim;Sung, Gyoo-Byung
    • Journal of Sericultural and Entomological Science
    • /
    • v.51 no.1
    • /
    • pp.20-29
    • /
    • 2013
  • Countries of the world are competing for the collection and utilization of genetic resources, which is a resource of value-added industrialization. We are building database of silkworm and mulberry resources with morphological, genetic characteristics data etc. Moreover, recent bioactive compound has been receiving increasing attention. So we analyzed 1-deoxynojirimycin(1-DNJ) content as a this item in addition to the basic information using 363 strains(varieties) of mulberry genetic resources. They were grown under the same environment and conditions. Mulberry leaves were collected and then freeze-dried and powdered for 1-DNJ test. As a result, 1-DNJ mean content of 363 mulberry strains was $0.176{\pm}0.077%$, and the coefficient of variation (CV) was 43.5%. The variation between the strains was greatly severe. Among the tested strains, 'C1D89/29' was showed the highest content of 0.47%, whereas 'Pumbo 24' and 'Turkey E' were showed the lowest content of 0.05% respectively. The content of 1-DNJ of 16 mulberry varieties for silkworm rearing were compared. Average concentration was $0.17{\pm}0.04%$, and the coefficient of variation (CV) was 22.8%. Variation among cultivars was not significant. Finally we selected 1-DNJ high-containing 11 strains. They are as follows. 'C1D89/29', 'Hiihak', 'Jeokasibmunja', 'Gweonchil', 'Botongsibmunja', 'Jeokchuk', 'bulguksang', 'Geunsookgojo', 'Busanggeum', 'Guksang 20' and 'Taekwang' which are more than twice of the overall average content.

Effect of night break treatment using Red LED (660 nm) on flower bud initiation and growth characteristics of chrysanthemum cv. 'Baekma', and cv. 'Jinba' (적색 LED(660nm)의 광중단 처리에 따른 국화 '백마'와 '신마'의 화아분화 및 생육특성)

  • Kwon, Young Soon;Choi, Seong Youl;Kil, Mi Jung;You, Bong Sik;Jung, Jae A;Park, Sang Kun
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.4
    • /
    • pp.297-303
    • /
    • 2013
  • This study was carried out to examine the effect of Red LED (660 nm) and fluorescent lamp for night break (NB) treatments of each 3 hours (22:30-01:30), 4 hours (22:00-02:00) and 5 hours (21:30-:02:30) per day for 53 days on flower bud initiation and growth in Chrysanthemum cv. 'Baekma' and cv. 'Jinba'. The days to flower budding after short-day treatment in 'Baekma' was longer at fluorescent lamp 4 hr (21.0 days) and 5 hr (20.5 days) NB, and it was shorter at Red LED 3 hr (14.2 days). The days to flowering after short-day treatment in 'Baekma' was longer at fluorescent lamp 4 hr (54.0 days), 5 hr (53.5 days) NB, and Red LED 5 hr (53.3 days), and it was shortest at Red LED 3 hr (50.2 days) NB treatment among all treatments. The days to flower budding after short-day treatment of 'Jinba' was longer at fluorescent lamp 4 hr (20.6 days) and was shorter at Red LED 3 hr (14.1 days) among all treatments. Similarly, the days to flowering after short-day treatment of 'Jinba' was longer at fluorescent lamp 4 hr (55.3 days) and was shortest at Red LED 3 hr (50.2 days) among all treatments. Therefore, inhibition of flower bud initiation was the most effective under fluorescent lamp 4 hr treatment. The length of cut flower of 'Baekma' was increased by fluorescent lamp 4 hr, 5 hr, and Red LED 5 hr, but of 'Jinba' was longer at LED 4 hr and 5 hr treatment. The weight of cut flower of 'Baekma' was heaviest at fluorescent lamp 5 hr treatment and was at Red LED 5hr treatment for 'Jinba' even though there was not statistically significant difference between 'Baekma' and 'Jinba'. Consequently, under fluorescent lamp 4 hr for night break was the most effective on flower bud initiation, flowering inhibition and cut-flower characteristics in 'Baekma' and 'Jinba'.

Seed Set in Close Pollination and Backcross of Interspecific F1 of Lilium spp. (백합 근연수분 및 종간 교잡종 F1 여교잡시 종자형성)

  • Lee, Ji-Yong;Lim, Yong-Pyo
    • Journal of Plant Biotechnology
    • /
    • v.30 no.4
    • /
    • pp.353-357
    • /
    • 2003
  • We studies seed set in the interspecific F1 /backcross hybrids of Lilium species. In the interspecfic hybrid of L. longiflorum cv. Gelria with L.${\times}$ fomolongi cv. Raizan,93% fruit set was obtained by stigmatic pollination in comparison to 53% from cut-style pollination. Accordingly, the number of seed set resulting from stigmatic and cut-style pollination was 147 and 53, respectively. Pollination o( both stigmatic and cut-style pollination resulted in 47% fruit set in the hybrid of L. longiflorum cv. Lorina with L.${\times}$ fomolongi cv. Raizan. However, stigmatic pollination formed 413 seeds, whereas only 24 seeds were obtained by cut-style pollination in this cross. The hybrid of L.${\times}$ fomolongi cv. Raizan with L. longiflorum cv. Come set 40% fruit with a total of 43 seeds by stigmatic pollination. However, no fruit set was observed in cut-style pollination in this hybrid. Backcrossing the F1 hybrid by cut-style pollination of L. longiflorum cv. Lorina ${\times}$ Asiatic hybrid cv. Chicago with the latter parent led to 53% fruit set, and 109 embryos were obtained. Likewise, backcrossing following cut-style pollination of L. longiflorum cv. Lorina ${\times}$ Asiatic hybrid cv. Corsia with the latter parent formed 67% fruits and 107 embryos. However, in the remaining interspecific hybrids, cut-style pollination set no fruit.

A Study of Surface Electromyography Measurement of Orbicularis oris motion in Healthy People (정상인의 구륜근 운동 시 표면근전도(SEMG) 측정연구)

  • Kim, Ju Yong;Kim, Bo Hyun;Kim, Hye Bin;Yook, Tae Han;Kim, Jong Uk
    • Journal of Acupuncture Research
    • /
    • v.33 no.4
    • /
    • pp.93-100
    • /
    • 2016
  • Objectives : To find an acupuncture point where more exact Surface Electromyography(SEMG) measurement can be drown, through the study of measurement of orbicularis oris. Methods : Of healthy people from 19 to 40 years of age, who did not fall under exclusion criteria (22 males and 22 females), were selected as subjects, after relaxation for 10 minutes, and they were told how to pronounce 'O' and 'U' with their lips puckered. The SEMG figures were measured with attaching disposable electrode on acupuncture point of right-and-left Hwaryo(LI19) and 1 cun away from Seungjang(CV24) on both sides when the subjects pronounced 'O' and 'U'. Results : The average value was highest on left 1 cun away from Seungjang(CV24) in pronouncing 'O' and 'U', and the average SEMG value was higher in the order of right 1 cun away from Seungjang(CV24), right Hwaryo(LI19), left Hwaryo(LI19). Average of the lower orbicularis oris is statistically higher than that of the upper orbicularis oris, which has significant meaning. However, there was no significant difference when compared by pronunciation. Average of percentage mark of differences of right-and-left measured value of each pronunciation and each acupuncture point : Pronounced 'O' and the upper part of orbicularis oris: $16.76{\pm}11.29%$, pronounced 'O' and the lower part of orbicularis oris: $22.41{\pm}12.92%$, pronounced 'U' and the upper part of orbicularis oris: $17.10{\pm}9.89%$, pronounced 'U' and the lower part of orbicularis oris : $19.20{\pm}10.82%$. Conclusion : The difference of pronunciation will not affect the results in SEMG measurement. In addition, the average of the lower orbicularis oris is statistically and significantly higher than that of the upper orbicularis oris.

Effects on the thermal change of the Taeyon(L1) and the Chungbu(L1) area following acupuncture stimulation on Taeyon(L9) in man (태연(太淵)(L9)자침(刺鍼)이 태연(太淵)(L9)과 중부(中府)(L1)영역(領域)의 온도변화(溫度變化)에 미치는 영향(影響))

  • Kim, Young-ho;Song, Beom-Yong;Yook, Tae-han
    • Journal of Acupuncture Research
    • /
    • v.18 no.5
    • /
    • pp.77-91
    • /
    • 2001
  • Backgrounds and purpose : The acupuncture of oriental medicine is very important in treatments. Until now it was been researched according to the meridian and qi xue(氣血) phenomenon of oriental medicine's theory. Acupuncture will show more objective index to observe the meridian. And then, I studied the effects on the thermal change of the Taeyon($L_9$) and Chungbu($L_1$) following acupuncture stimulation. Objective and Methods : This study was performed from December 1999 to February 2000 on 60 healthy students. The objective was divided into two groups, those are the control group A(N=30) that no acupuncture stimulation, the group B(N=30) of acupuncture stimulation on Taeyon($L_9$). First, in the control group A, I took a picture Taeyon($L_9$) Chungbu($L_1$) Taenung($P_7$) Chondol($CV_{22}$) area for 30 men without any stimulation with the Digital Infrared Thermograph Imaging(D.I.T.l.) and did same area, 10min after. Second, in the acupuncture stimulation group B, we took a picture Taeyon($L_9$) Chungbu($L_1$) Taenung($P_7$) Chondol($CV_{22}$) area for 30 men without any stimulation with the Digital Infrared Th - ermograph Imaging(D.I.T.I.), and then stimulate acupuncture on Taeyon($L_9$) and took a picture same area, 10min after. Results : 1. In healthy men, average skin temperture on Taeyon($L_9$) area was lower than Chungbu($L_1$) area about $3.0^{\circ}C$, in the Lt. Taeyon($L_9$) and Chungbu($L_1$) area was lower than Rt. Taeyon($L_9$) and Chungbu($L_1$) area. 2. In the acupuncture stimulation group B, the skin temperature of both side Taeyon($L_9$) area showed the increase or decrease significantly. But both Taenung($P_7$) area did not showed significantly. 3. In the acupuncture stimulation group B, the skin temperature of both side Chungbu($L_1$) area showed the increase or decrease significantly. But both Chondol($CV_{22}$) area did not showed significantly. 4. The thermal changes of the area which is a meridian point in the Lung Meridian of the acupuncture stimulation group on Taeyon($L_9$) different from other Meridian with significantly change. Conclusion : The acupuncture stimulation on Taeyon($L_9$) affected the thermal change of the area which is a meridian point, in the Lung Meridian. And then I could relate these results with the existence of the meridian and meridian point. Thus, continuous thermographic study will be needed for the existence of the meridian and meridian point.

  • PDF