• Title/Summary/Keyword: CTS System

Search Result 81, Processing Time 0.021 seconds

Implementation and Verification of Distance Relay Models for Real Time Digital Simulator (실시간 전력계통 시뮬레이터를 이용한 보호계전모델 개발)

  • Lee, Joo-Hun;Yoon, Yong-Beum;Cha, Seung-Tae;Lee, Jin;Choe, Jong-Woon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.7
    • /
    • pp.393-400
    • /
    • 2003
  • This paper discusses how to implement and verify a software model of the digital relay that can be added to real time digital simulator(RTDS) model library and is then subjected to the same outputs as the actual relay. The software model is stand-alone and can be used with real relays. It is also possible to conduct interactive real-time tests when the system effects of the relay action need to be investigated. The characteristics of mho type and the quadrilateral type, which is commonly used in recently developed relays, are modeled in this paper. Single circuit line and double circuit line system are used for model verification. The transmission lines are each 100 km in length and are modeled as distributed parameter lines but not frequency dependent. The transmission lines in the single circuit system are modeled as ideally transposed line. The mutual coupling data with the parallel line was taken account in the transmission lines for the double circuit system. The main CTs and PTs are included and operated in their linear region during the tests. For the purpose of testing the relay model accuracy the faults have been applied at various points on the protected line. Its accuracy is assessed against theoretical values.

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

CTKOS : Categorized Tag-based Knowledge Organization System (카테고리형 태그 기반의 지식조직체계 구현)

  • Yoo, Dong-Hee;Kim, Gun-Woo;Choi, Keun-Ho;Suh, Yong-Moo
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.4
    • /
    • pp.59-74
    • /
    • 2011
  • As more users are willingly participating in the creation of web contents, flat folksonomy using simple tags has emerged as a powerful instrument to classify and share a huge amount of knowledge on the web. However, flat folksonomy has semantic problems, such as ambiguity and misunderstanding of tags. To alleviate such problems, many studies have built structured folksonomy with a hierarchical structure or relationships among tags. However, structured folksonomy also has some fundamental problems, such as limited tagging to pre-defined vocabulary for new tags and the timeconsuming manual effort required for selecting tags. To resolve these problems, we suggested a new method of attaching a categorized tag (CT), followed by its category, to web content. CTs are automatically integrated into collaboratively-built structured folksonomy (CSF) in real time, reflecting the tag-and-category relationships by majority users. Then, we developed a CT-based knowledge organization system (CTKOS), which builds the CSF to classify organizational knowledge and allows us to locate the appropriate knowledge.

A Study of automatic indexing based on the linguistic analysis for newspaper articles (언어학적 분석기법에 의한 신문기사 자동색인시스팀 설계에 관한 연구)

  • Seo, Gyeong-Ju;SaGong, Cheol
    • Journal of the Korean Society for information Management
    • /
    • v.8 no.1
    • /
    • pp.78-99
    • /
    • 1991
  • So far, most of Korea's newspapers indexing have been done manually using tesaurus. In recent years, however, the need for automatic indexing system has grown stronger so as for indexers to save time, efforts and money. And some newspapers have started establishing their databases along with introducing electronic newspapers and CTS. This thesis is on establishing and automatic indexing system for the full-text of the Korea Economic Daily's articles, which have been accumulated in its database, KETEL. In my thesis, I suggest methods to create a keyword file, a stopword list, an auxiliary word list and an infected word list by applying linguistic analysis methods to Hangul, taking advantage of the language's morphological peculiarity. Through these studies, I was able to reach four conclusions as follows. First, we can obtain satisfactory keywords by automatic indexing methods that were made through morphological analysis. Second, an indexer can improve the efficiency of indexing work by controlling extracted vocabulary, as syntax analysis and semantic analysis is not complete in Hangul. Third, The keyword file in this system which is made of about 20,000 most-frequently-used newspaper terms can be used in the future in compiling a thesaurus. Finally, the suggested methods to prepare an auxiliary word list and an infected word list can be applicable to designing other automatic systems.

  • PDF

OpenGL ES 2.0 Emulation on Desktop PCs (데스크탑 상에서의 OpenGL ES 2.0 에뮬레이션)

  • Baek, Nakhoon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.4
    • /
    • pp.125-128
    • /
    • 2014
  • OpenGL ES(OpenGL for Embedded System) 2.0 is one of the most widely used 3D graphics API(application progrma interface) standard for smart phones and tablet PCs at this time. During programming with this API, they prefer desktop environment rather than the target mobile environment, which has relatively low computing power. Thus, we need to emulate the OpenGL ES 2.0 API on the desktop PCs, where only OpenGL API libraries are available. In this paper, we present technical difficulties and their solutions to emulate OpenGL ES 2.0 on desktop PCs. Our final implementation of OpenGL ES 2.0 emulation library works on desktop PCs and passed over more than 96% of the official CTS(conformance test suites) to prove the correctness of our implementation. Additionally, for the commercially available benchmark programs, our implementation shows equivalent execution speeds to the previous commercial OpenGL ES 2.0 implementations.

Implementation of a Deep Learning-Based Computer-Aided Detection System for the Interpretation of Chest Radiographs in Patients Suspected for COVID-19

  • Eui Jin Hwang;Hyungjin Kim;Soon Ho Yoon;Jin Mo Goo;Chang Min Park
    • Korean Journal of Radiology
    • /
    • v.21 no.10
    • /
    • pp.1150-1160
    • /
    • 2020
  • Objective: To describe the experience of implementing a deep learning-based computer-aided detection (CAD) system for the interpretation of chest X-ray radiographs (CXR) of suspected coronavirus disease (COVID-19) patients and investigate the diagnostic performance of CXR interpretation with CAD assistance. Materials and Methods: In this single-center retrospective study, initial CXR of patients with suspected or confirmed COVID-19 were investigated. A commercialized deep learning-based CAD system that can identify various abnormalities on CXR was implemented for the interpretation of CXR in daily practice. The diagnostic performance of radiologists with CAD assistance were evaluated based on two different reference standards: 1) real-time reverse transcriptase-polymerase chain reaction (rRT-PCR) results for COVID-19 and 2) pulmonary abnormality suggesting pneumonia on chest CT. The turnaround times (TATs) of radiology reports for CXR and rRT-PCR results were also evaluated. Results: Among 332 patients (male:female, 173:159; mean age, 57 years) with available rRT-PCR results, 16 patients (4.8%) were diagnosed with COVID-19. Using CXR, radiologists with CAD assistance identified rRT-PCR positive COVID-19 patients with sensitivity and specificity of 68.8% and 66.7%, respectively. Among 119 patients (male:female, 75:44; mean age, 69 years) with available chest CTs, radiologists assisted by CAD reported pneumonia on CXR with a sensitivity of 81.5% and a specificity of 72.3%. The TATs of CXR reports were significantly shorter than those of rRT-PCR results (median 51 vs. 507 minutes; p < 0.001). Conclusion: Radiologists with CAD assistance could identify patients with rRT-PCR-positive COVID-19 or pneumonia on CXR with a reasonably acceptable performance. In patients suspected with COVID-19, CXR had much faster TATs than rRT-PCRs.

Implementation and Analysis of the Agent based Object-Oriented Software Test Tool, TAS (에이전트 기반의 객체지향 소프트웨어 테스트 도구인 TAS의 구현 및 분석)

  • Choi, Jeon-Geun;Choi, Byoungju
    • Journal of KIISE:Software and Applications
    • /
    • v.28 no.10
    • /
    • pp.732-742
    • /
    • 2001
  • The concept of an agent has become important in computer science and has been applied to the number of application domains such electronic commerce and information retrieval. But, no one has proposed yet in software test. The test agent system applied the concept of an agent to software test is new test tool. It consists of the User Interface Agent. the Test Case Selection & Testing Agent and the Regression Test Agent. Each of these agents, with their intelligent rules, carry out the tests autonomously by empolying the object-oriented test processes. This system has 2 advantages. Firstly since the tests are carried our autonomously, it minimizes tester interference and secondly, since redundant-free and consistent effective test cases are intellectually selected, the testing time is reduced while the fault detection effectiveness improves. In this paper, by actually showing the testing process being carried out autonomously by the 3 agents that form the TAS, we show that the TAS minimizes tester interference. By also carrying out the 4 different types of experiments on the RE-Rule, CTS-Rule, overall TAS experiment, and the fault-detection effectiveness experiment on the RE-Rule, we show the cut-down on the testing time and improvement in the fault detection effectivity.

  • PDF

IMAGE FUSION ACCURACY FOR THE INTEGRATION OF DIGITAL DENTAL MODEL AND 3D CT IMAGES BY THE POINT-BASED SURFACE BEST FIT ALGORITHM (Point-based surface best fit 알고리즘을 이용한 디지털 치아 모형과 3차원 CT 영상의 중첩 정확도)

  • Kim, Bong-Chul;Lee, Chae-Eun;Park, Won-Se;Kang, Jeong-Wan;Yi, Choong-Kook;Lee, Sang-Hwy
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.5
    • /
    • pp.555-561
    • /
    • 2008
  • Purpose: The goal of this study was to develop a technique for creating a computerized composite maxillofacial-dental model, based on point-based surface best fit algorithm and to test its accuracy. The computerized composite maxillofacial-dental model was made by the three dimensional combination of a 3-dimensional (3D) computed tomography (CT) bone model with digital dental model. Materials and Methods: This integration procedure mainly consists of following steps : 1) a reconstruction of a virtual skull and digital dental model from CT and laser scanned dental model ; 2) an incorporation of dental model into virtual maxillofacial-dental model by point-based surface best fit algorithm; 3) an assessment of the accuracy of incorporation. To test this system, CTs and dental models from 3 volunteers with cranio-maxillofacial deformities were obtained. And the registration accuracy was determined by the root mean squared distance between the corresponding reference points in a set of 2 images. Results and Conclusions: Fusion error for the maxillofacial 3D CT model with the digital dental model ranged between 0.1 and 0.3 mm with mean of 0.2 mm. The range of errors were similar to those reported elsewhere with the fiducial markers. So this study confirmed the feasibility and accuracy of combining digital dental model and 3D CT maxillofacial model. And this technique seemed to be easier for us that its clinical applicability can good in the field of digital cranio-maxillofacial surgery.

Development of a Vehicle Relocation Algorithm for the Promotion of One-way Car Sharing Service (공유차량의 효율적 단방향 서비스를 위한 차량 재배치 알고리즘)

  • Kim, Seung Hyun;Jung, Hee Jin;Bea, Sang Hoon
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.3
    • /
    • pp.239-247
    • /
    • 2014
  • In modern society, the transportation sector is having difficulties with mobility, safety, energy and environment issues so that solutions should be prepared progressively. Recently developed countries are paying greater attention to car-sharing systems as alternatives for relieving problems caused by increasing number of vehicles. Car-sharing systems are believed to keep the number of personal vehicles down and traffic congestion due to the fact that this system induces efficiency of vehicle operation. In this study, authors focused on solving the imbalance problem of car-sharing systems dynamically, to specifically improve one-way car sharing service. Therefore vehicle relocation algorithm was designed for maximizing profit of car sharing operators. For the application of the vehicle relocation algorithm among rental offices, we selected Haeundae-gu, Busan as the area of study. Rental offices have been designated to the zone centroid and we calculated the shortest path between rental offices by using TransCAD. In the study, we adapted MATLAB for the application of vehicle relocation algorithm. As the results, the total vehicle relocation time was estimated as 59.9 minutes. In addition, vehicle relocation algorithm was verified successfully by using Decision Tree method.

Development of 4D CT Data Generation Program based on CAD Models through the Convergence of Biomedical Engineering (CAD 모델 기반의 4D CT 데이터 제작 의용공학 융합 프로그램 개발)

  • Seo, Jeong Min;Han, Min Cheol;Lee, Hyun Su;Lee, Se Hyung;Kim, Chan Hyeong
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.4
    • /
    • pp.131-137
    • /
    • 2017
  • In the present study, we developed the 4D CT data generation program from CAD-based models. To evaluate the developed program, a CAD-based respiratory motion phantom was designed using CAD software, and converted into 4D CT dataset, which include 10 phases of 3D CTs. The generated 4D CT dataset was evaluated its effectiveness and accuracy through the implementation in radiation therapy planning system (RTPS). Consequently, the results show that the generated 4D CT dataset can be successfully implemented in RTPS, and targets in all phases of 4D CT dataset were moved well according to the user parameters (10 mm) with its stationarily volume (8.8 cc). The developed program, unlike real 4D CT scanner, due to the its ability to make a gold-standard dataset without any artifacts constructed by modality's movements, we believe that this program will be used when the motion effect is important, such as 4D radiation treatment planning and 4D radiation imaging.