• 제목/요약/키워드: CTS

검색결과 371건 처리시간 0.034초

방아쇠수지가 손목터널증후군 환자의 악력, 통증 및 상지기능에 미치는 영향: 단면적 연구 (Effect of Trigger Finger on Pain, Grip Strength and Function of Upper Limb of Patients with Carpal Tunnel Syndrome: A Cross-sectional Study)

  • 김명권;윤다은
    • 대한물리의학회지
    • /
    • 제16권1호
    • /
    • pp.63-71
    • /
    • 2021
  • PURPOSE: The purpose of this study was to investigate the effects of trigger finger on pain, muscle strength and function in carpal tunnel syndrome (CTS) patients. METHODS: A total of 60 subjects (30 carpal tunnel syndrome with trigger finger and 30 carpal tunnel syndrome without trigger finger) were assessment for pain, muscle strength (power grip, key pinch , tip to tip pinch, three jaw pinch) and function. The effect sizes of the two groups were compared, and the correlation between the trigger finger and each variable was analyzed. RESULTS: The results showed that there were significantly difference in the pain, muscle strength excluding three jaw pinch and function (p < .05). The results also showed correlation between trigger finger and pain (r = .552), muscle strength excluding three jaw pinch (power grip r = -.296, key pinch r = -.260, tip to tip pinch r = -.285), and function (r = .375). The function of carpal tunnel syndrome patients was related to pain (r = .550) and power grips (r = -.324) of muscle strength. CONCLUSION: In carpal tunnel syndrome patients with trigger finger compared to carpal tunnel syndrome, muscle weakness, pain increase, and function reduction were shown. In addition, trigger finger are correlated with muscle strength, pain and function, and muscle weakness and increased pain affect the daily living of carpal tunnel syndrome patients with triggers finger. Therefore, physical therapy interventions of carpal tunnel syndrome patients with trigger finger should be combined with treatment for muscle strength enhancement as well as pain reduction.

유기불안이 심리적 데이트폭력에 미치는 영향: 거부민감성과 관계중독의 매개효과 (The Effects of Abandonment Anxiety on Psychological Dating Violence: The Mediating Effects of Rejection Sensitivity and Relationship Addiction)

  • 박미소;이지연
    • 한국콘텐츠학회논문지
    • /
    • 제21권4호
    • /
    • pp.248-261
    • /
    • 2021
  • 본 연구는 유기불안과 심리적 데이트폭력의 관계에서 거부민감성과 관계중독의 매개효과를 검증하는데 목적이 있다. 이를 위해 성인남녀 400명의 자료를 수집하여 분석하였고, 구조방정식을 사용하여 검증하였다. 측정도구로는 유기불안 척도(AAS), 거부민감성 척도(RSQS), 관계중독 질문지(RAQ-30), 심리적 데이트폭력은 갈등 관리 척도-2(CTS-2)와 통제행동척도(APCS)을 합산한 척도가 사용되었다. 연구 결과는 다음과 같다. 첫째, 유기불안, 거부민감성, 관계중독, 심리적 데이트폭력은 모두 유의한 정적상관을 나타냈다. 둘째, 유기불안과 심리적 데이트폭력의 관계에서 직접효과는 나타나지 않았지만, 유기불안이 거부민감성과 관계중독을 이중 매개 하여 심리적 데이트폭력에 영향을 미쳤다. 이러한 결과를 바탕으로 유기불안이 심리적 데이트폭력에 영향을 미치는 심리적 경로를 확인하고, 가시적으로 잘 드러나지 않는 부정적인 대인관계패턴에서 치료적 개입과 교육적 접근이 필요함을 논의하였다.

Licochalcone H Induces Cell Cycle Arrest and Apoptosis in Human Skin Cancer Cells by Modulating JAK2/STAT3 Signaling

  • Park, Kyung-Ho;Joo, Sang Hoon;Seo, Ji-Hye;Kim, Jumi;Yoon, Goo;Jeon, Young-Joo;Lee, Mee-Hyun;Chae, Jung-Il;Kim, Woo-Keun;Shim, Jung-Hyun
    • Biomolecules & Therapeutics
    • /
    • 제30권1호
    • /
    • pp.72-79
    • /
    • 2022
  • Licochalcone H (LCH) is a phenolic compound synthetically derived from licochalcone C (LCC) that exerts anticancer activity. In this study, we investigated the anticancer activity of LCH in human skin cancer A375 and A431 cells. The 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium (MTS) cell viability assay was used to evaluate the antiproliferative activity of LCH. Cell cycle distribution and the induction of apoptosis were analyzed by flow cytometry. Western blotting assays were performed to detect the levels of proteins involved in cell cycle progression, apoptosis, and the JAK2/STAT3 signaling pathway. LCH inhibited the growth of cells in dose- and time-dependent manners. The annexin V/propidium iodide double staining assay revealed that LCH induced apoptosis, and the LCH-induced apoptosis was accompanied by cell cycle arrest in the G1 phase. Western blot analysis showed that the phosphorylation of JAK2 and STAT3 was decreased by treatment with LCH. The inhibition of the JAK2/STAT3 signaling pathway by pharmacological inhibitors against JAK2/STAT3 (cryptotanshinone (CTS) and S3I-201) simulated the antiproliferative effect of LCH suggesting that LCH induced apoptosis by modulating JAK2/STAT3 signaling.

체적골밀도 측정법 동향: 수술부위 골밀도 분석 (Volumetric Bone Mineral Density Measurement: for Surgery Specific Bone Volumes)

  • 이연수
    • 한국방사선학회논문지
    • /
    • 제16권1호
    • /
    • pp.53-59
    • /
    • 2022
  • CT영상을 기반으로 한 QCT는 CT장비와 컴퓨터영상처리기술의 발전과 함께 적은 방사선 투과양으로도 체적골밀도를 측정할 수 있는 방향으로 크게 발전하고 있다. 방사선 의료영상을 대표적인 골밀도 측정법인 이중방사선흡수계수법(DXA)은 척추나 근위대퇴골과 다른 뼈와의 상관성이 떨어지는 경우가 많고질량효과에 의한 부정확성의 근본 원인을 가지고 있기 때문에 체적골밀도측정법인 단일에너지CT영상을 이용한 QCT법이 가장 보편적인 정확한 골밀도 측정법이다. 이중에너지CT의 사용은 단단한 뼈와 동시에 종양이나 연부조직의 이상을 같이 볼 수 있는 영상을 얻을 수 있게 되어 QCT 골밀도와 함께 특정연부조직이나 장기를 검사할 수 있어 그 사용이 더욱 늘어날 것으로 예상된다. 임상수술이나 추적검사가 필요한 위치에 사용자가 해부학적으로 특정한 형상체적에 대한 국부골밀도측정 방법도 병원의 임상현장에서 활용할 기술로 대두되고 있다.

무선 메쉬 네트워크에서 인터페이스 수와 성능에 관한 연구 (A Study on the Optimal Number of Interfaces in Wireless Mesh Network)

  • 오치문;김화종;이구연;정충교
    • 한국시뮬레이션학회논문지
    • /
    • 제18권1호
    • /
    • pp.1-7
    • /
    • 2009
  • 본 논문에서는 고정된 멀티 채널 멀티 인터페이스 무선 메쉬 네트워크 환경에서의 최적의 인터페이스 수를 시뮬레이션을 통해 알아본다. 채널 경쟁기반의 무선통신망에서 하나의 인터페이스 및 채널을 사용하는 경우 임의노드 주변에 동일 채널에 경쟁하는 노드가 많으면 경쟁 및 전송 충돌로 인한 지연이 발생하며, 이는 통신망의 성능을 저하시키는 결과를 낳는다. 이에 대한 해결책으로 다수의 인터페이스를 장착하고 인터페이스마다 한 개의 채널을 사용하게 되면 채널 간섭을 피할 수 있고 또한 전송 충돌을 줄일 수 있기 때문에 통신망의 성능을 향상시킬 수 있다. 현재 802.11a 및 802.11b에서는 각각 12개와 3개의 서로 다른 직교 채널을 제공하고 있으므로 채널수에 맞는 다수의 인터페이스를 장착한다면 무선 통신망의 성능을 향상시킬 수 있게 된다. 그러나 환경에 따라 몇 개의 인터페이스/채널을 사용해야 성능이 최적이 되는지에 대한 연구는 아직 많지 않다. 인터페이스/채널 수를 늘리면 어느 정도 성능이 향상될 것으로 추론할 수 있으나, 인터페이스/채널 수를 한없이 늘리는 것은 오히려 성능 저하를 가져올 수도 있다. 이에 본 논문에서는 이러한 점에 기반하여 다양한 환경에서 성능 향상에 필요한 최적의 인터페이스/채널 수를 시뮬레이션을 통해 알아본다.

Effects of dentin surface preparations on bonding of self-etching adhesives under simulated pulpal pressure

  • Chantima Siriporananon;Pisol Senawongse;Vanthana Sattabanasuk;Natchalee Srimaneekarn;Hidehiko Sano;Pipop Saikaew
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.4.1-4.13
    • /
    • 2022
  • Objectives: This study evaluated the effects of different smear layer preparations on the dentin permeability and microtensile bond strength (µTBS) of 2 self-etching adhesives (Clearfil SE Bond [CSE] and Clearfil Tri-S Bond Universal [CTS]) under dynamic pulpal pressure. Materials and Methods: Human third molars were cut into crown segments. The dentin surfaces were prepared using 4 armamentaria: 600-grit SiC paper, coarse diamond burs, superfine diamond burs, and carbide burs. The pulp chamber of each crown segment was connected to a dynamic intra-pulpal pressure simulation apparatus, and the permeability test was done under a pressure of 15 cmH2O. The relative permeability (%P) was evaluated on the smear layer-covered and bonded dentin surfaces. The teeth were bonded to either of the adhesives under pulpal pressure simulation, and cut into sticks after 24 hours water storage for the µTBS test. The resin-dentin interface and nanoleakage observations were performed using a scanning electron microscope. Statistical comparisons were done using analysis of variance and post hoc tests. Results: Only the method of surface preparation had a significant effect on permeability (p < 0.05). The smear layers created by the carbide and superfine diamond burs yielded the lowest permeability. CSE demonstrated a higher µTBS, with these values in the superfine diamond and carbide bur groups being the highest. Microscopic evaluation of the resin-dentin interface revealed nanoleakage in the coarse diamond bur and SiC paper groups for both adhesives. Conclusions: Superfine diamond and carbide burs can be recommended for dentin preparation with the use of 2-step CSE.

Assessment of a Deep Learning Algorithm for the Detection of Rib Fractures on Whole-Body Trauma Computed Tomography

  • Thomas Weikert;Luca Andre Noordtzij;Jens Bremerich;Bram Stieltjes;Victor Parmar;Joshy Cyriac;Gregor Sommer;Alexander Walter Sauter
    • Korean Journal of Radiology
    • /
    • 제21권7호
    • /
    • pp.891-899
    • /
    • 2020
  • Objective: To assess the diagnostic performance of a deep learning-based algorithm for automated detection of acute and chronic rib fractures on whole-body trauma CT. Materials and Methods: We retrospectively identified all whole-body trauma CT scans referred from the emergency department of our hospital from January to December 2018 (n = 511). Scans were categorized as positive (n = 159) or negative (n = 352) for rib fractures according to the clinically approved written CT reports, which served as the index test. The bone kernel series (1.5-mm slice thickness) served as an input for a detection prototype algorithm trained to detect both acute and chronic rib fractures based on a deep convolutional neural network. It had previously been trained on an independent sample from eight other institutions (n = 11455). Results: All CTs except one were successfully processed (510/511). The algorithm achieved a sensitivity of 87.4% and specificity of 91.5% on a per-examination level [per CT scan: rib fracture(s): yes/no]. There were 0.16 false-positives per examination (= 81/510). On a per-finding level, there were 587 true-positive findings (sensitivity: 65.7%) and 307 false-negatives. Furthermore, 97 true rib fractures were detected that were not mentioned in the written CT reports. A major factor associated with correct detection was displacement. Conclusion: We found good performance of a deep learning-based prototype algorithm detecting rib fractures on trauma CT on a per-examination level at a low rate of false-positives per case. A potential area for clinical application is its use as a screening tool to avoid false-negative radiology reports.

Implementation of a Deep Learning-Based Computer-Aided Detection System for the Interpretation of Chest Radiographs in Patients Suspected for COVID-19

  • Eui Jin Hwang;Hyungjin Kim;Soon Ho Yoon;Jin Mo Goo;Chang Min Park
    • Korean Journal of Radiology
    • /
    • 제21권10호
    • /
    • pp.1150-1160
    • /
    • 2020
  • Objective: To describe the experience of implementing a deep learning-based computer-aided detection (CAD) system for the interpretation of chest X-ray radiographs (CXR) of suspected coronavirus disease (COVID-19) patients and investigate the diagnostic performance of CXR interpretation with CAD assistance. Materials and Methods: In this single-center retrospective study, initial CXR of patients with suspected or confirmed COVID-19 were investigated. A commercialized deep learning-based CAD system that can identify various abnormalities on CXR was implemented for the interpretation of CXR in daily practice. The diagnostic performance of radiologists with CAD assistance were evaluated based on two different reference standards: 1) real-time reverse transcriptase-polymerase chain reaction (rRT-PCR) results for COVID-19 and 2) pulmonary abnormality suggesting pneumonia on chest CT. The turnaround times (TATs) of radiology reports for CXR and rRT-PCR results were also evaluated. Results: Among 332 patients (male:female, 173:159; mean age, 57 years) with available rRT-PCR results, 16 patients (4.8%) were diagnosed with COVID-19. Using CXR, radiologists with CAD assistance identified rRT-PCR positive COVID-19 patients with sensitivity and specificity of 68.8% and 66.7%, respectively. Among 119 patients (male:female, 75:44; mean age, 69 years) with available chest CTs, radiologists assisted by CAD reported pneumonia on CXR with a sensitivity of 81.5% and a specificity of 72.3%. The TATs of CXR reports were significantly shorter than those of rRT-PCR results (median 51 vs. 507 minutes; p < 0.001). Conclusion: Radiologists with CAD assistance could identify patients with rRT-PCR-positive COVID-19 or pneumonia on CXR with a reasonably acceptable performance. In patients suspected with COVID-19, CXR had much faster TATs than rRT-PCRs.

Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가 (The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan)

  • 정은미;성지혜;유희재
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.90-93
    • /
    • 2011
  • Pixelated BSGI 감마카메라는 높은 분해능과 민감도를 특징으로 하며, 좁은 FOV로 인하여 검출기와 장기간의 거리를 최소화 할 수 있는 장점이 있다. 따라서, 국소 장기인 갑상선, 부갑상선, 담낭 등의 검사에 유용하다고 알려져 있다. 일반적으로 핵의학 검사에서 감마카메라를 사용하여 국소 장기를 영상화할 때 상의 크기를 확대하고, 우수한 분해능을 획득하고자 바늘구멍 조준기(Pinhole Collimator)를 사용한다. 이에 본 연구에서는 대표적인 국소장기인 갑상선 검사를 대상으로 바늘구멍 조준기로 획득한 영상 과 Pixilated BSGI 감마카메라로 획득한 영상을 비교하여 갑상선 검사 시 Pixilated Breast-Specific Gamma Imaging(BSGI) 감마카메라의 유용성을 평가 하였다. $^{99m}TcO_4^-$을 넣은 갑상선 팬텀을 이용 하였다. 바늘구멍 조준기를 장착한 INFINIA 감마카메라와 저 에너지 고 분해능용 평행다중구멍 조준기를 장착한 Pixelated BSGI 감마카메라에서 300 sec 또는 100 kcts로 설정 후 영상을 획득하였다. 모든 영상 획득은 현재 서울아산병원에서 실제 환자에게 적용하고 있는 갑상선 검사 절차와 동일한 방법으로 시행하였다. 그 결과 INFINIA 감마카메라와 Pixelated BSGI 감마카메라의 갑상선 팬텀 영상을 비교한 결과 Pixellated BSGI 감마카메라에서 갑상선 팬텀의 열소(hot spot)와 냉소(cold spot)의 구분을 더욱 명확하게 확인 할 수 있었다. 갑상선 검사시 Pixilated BSGI 감마카메라는 영상획득 시간을 단축시킬 수 있을 뿐만 아니라 더 나아가 투여하는 방사성의약품의 양을 줄임으로써 환자의 피폭을 경감 시킬 수 있다. 촬영시간의 단축은 환자의 호흡 및 움직임을 최소화하여 더 좋은 영상을 얻을 수 있다. 또한 Pixelated BSGI 감마카메라의 검출기는 작고 다양한 회전이 가능하므로 장기와 검출기 사이 거리를 최소화 할 수 있고, 장비자체의 이동도 가능하므로 환자의 이동이 불가 한 경우 매우 유용하다. 그러나 이러한 장점에도 불구하고 Pixelated (BSGI) 감마카메라는 방사성의약품의 집적이 매우 낮은 유방 촬영 전용으로 제작했기 때문에 2000 cts/s 이상에서는 불감시간 효과가 발생한다. 따라서 Pixelated BSGI 감마카메라를 핵의학 갑상선 검사에 적용할 경우 방사성의약품의 투여량의 조절과 영상획득 시간의 조정에 대한 연구가 더 필요할 것으로 사료된다.

  • PDF

MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가 (The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography))

  • 류귀복;김현수;유광열;동경래;권대철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.127-132
    • /
    • 2010
  • 본 연구의 목적은 MDCT의 iso-center에서 detector의 Z-축 범위 이외에서 발생하는 산란선을 측정하고 산란선을 경감하기 위한 기준설정에 기초 자료를 제시하고자 하는 것이다. MDCT의 발전은 환자 Z-축으로의 빔의 확대를 가져오게 되었으며 이는 산란선의 증가로 이어져 피폭선량의 증가에 기여하게 되었다. 또한 MDCT는 SDCT에 비하여 빔 두께의 차이에 따라 최고 4배까지 산란선이 증가하고 있다. MDCT에서 빔 두께 변화에 따른 산란선을 평가하기 위하여 16-slice CT 1대, 64-slice CT 2대의 장비를 이용하여 다배열검출기(MDCT)의 Z-축의 넓이에 따른 산란선을 측정하였다. 측정 장비로는 이온챔버 60 ml 2026C를 사용하였다. 측정결과 장비 별 빔 두께에 따른 산란선의 변화는 동일한 kVp에서 빔 두께가 2배 증가함에 따라 평균 1.7~1.8배의 산란선의 증가가 있었다. 또한 관전압에 따른 산란선의 변화를 평가한 결과 관전압이 80 kVp에서 120 kVp로 40 kVp 증가함에 따라 64 slice 장비에서는 평균 3.47~3.79배의 산란선 증가가 있었고 16 slice 장비에서는 평균 2.47배의 산란선 증가가 있었다. 마지막으로 iso-center로부터의 거리변화에 따른 산란선을 측정한 결과 이온챔버의 거리가 2배 증가함에 따라 2.11~2.25배의 산란선 감소가 있었다. 본 연구는 의료영상 진단 장비인 CT 장비의 Z-축 빔 두께 증가와 관전압, 거리에 따른 산란선을 평가하는데 있다. 이에 따라 뇌 CT 검사 시 갑상선, 안구 등의 차폐문제와 복부 CT 검사 시 갑상선, 생식선 등의 차폐문제가 무시할 수 없음을 알 수 있었다. 현재 슬라이스 내의 선량에 대한 연구가 주로 이루어지고 있는 시점에서 본 연구를 통하여 detector의 Z-축빔 두께 증가에 따른 Z-축 범위 이외의 산란선의 증가를 이해하고, 검사목적 부위 이외의 산란선 연구에 대한 필요성과 MDCT를 이용한 CT 검사 시 차폐의 중요성을 인식하여야 한다.