• Title/Summary/Keyword: CT99

Search Result 351, Processing Time 0.05 seconds

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

A Comparative Study of SPECT, q-EEG and CT in Patients with Mild, Acute Head Trauma (경미한 급성 두부외상환자에서 SPECT, q-EEG 및 CT의 비교)

  • Lee, Suk-Ho;Kim, Jin-Seok;Moon, Hee-Seung;Lee, Sung-Ku;Kim, So-Yon;Kim, Young-Jung;Park, Byung-Yik;Lee, Gwon-Jeon;Kim, Kap-Deuk;Kim, Ho-Joeng;Cho, Kyeung-Hyeung;Seol, Hyun-Uk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.165-169
    • /
    • 1993
  • Functional cerebral impairments have been verified objectively by brain SPECT and q-EEG (quantitative electroencephalography). Microcerebral circulatory defects without anatomical changes can-not be detected by the brain CT or MRI. Brain SPECT using $^{99m}Tc$-HMPAO (Hexamethyl propyleneamine oxime) as a key radioisotope may be accepted as the useful method for identifying functional cerebral impairments. We studied 25 patients with mild head trauma to define whether the SPECT was helpful in detecting cerebral impairment. Results were as follows: The SPECT was positive in 23 patients out of 25, q-EEG positive in 16 patients and brain CT was positive in 3 cases. SPECT and q-EEG were more sensitive than CT, SPECT would be more useful method than brain CT to investigate cerebral function after head injury.

  • PDF

Comparison of Standardized Peristomal Skin Care and Crusting Technique in Prevention of Peristomal Skin Problems in Ostomy Patients

  • Park, Seung-Mi;Lee, Yun-Jin;Oh, Doo-Nam;Kim, Ji-Yun
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.6
    • /
    • pp.814-820
    • /
    • 2011
  • Purpose: This study was performed to compare the effects of standardized peristomal skin care (SPSC) and crusting technique (CT) on the peristomal skin of ostomates. SPSC was developed by a consensus among the expert group based on a comprehensive review of the relevant literature and hospital protocols. Methods: A randomized controlled pilot trial with 2 parallel arms was used. A total of 81 ostomates, who were recruited from a tertiary hospital, completed the baseline, 1-month, 2-month, and 3-month follow-up (SPSC group, n=45; CT group, n=36). SPSC consisted of water cleansing and direct application of ostomy appliances. CT involved crusting hydrocolloid powder and patting with water sponge or protective barrier liquid film. The outcomes of the study were assessed by skin problems, such as discoloration, erosion and tissue overgrowth; the domains of the evaluation tool used in examining the peristomal skin. A generalized estimating equation model was used to examine the effects according to time and group. Results: In both SPSC and CT groups, the likelihood of occurrence of discoloration (OR, 1.99; 95% CI, 1.61-2.46), erosion (OR, 1.87; 95% CI, 1.55-2.25) and tissue enlargement (OR, 1.94; 95% CI, 1.36-2.77) increased with time. There was no significant difference in discoloration between the groups, whereas the probability of erosion (OR, 0.38; 95% CI, 0.16-0.89) and tissue overgrowth (OR, 0.09; 95% CI, 0.02-0.55) was lower in the SPSC group than in CT group. Conclusion: SPSC was sufficient in preventing peristomal skin problems of ostomates compared to the CT.

Comparison of Functional Constituents and Biological Activity of the Seed Extracts from Two Mulberry Fruits

  • Kim, Eun-Ok;Yu, Myeong-Hwa;Lee, Yu-Jin;Leem, Hyun-Hee;Kim, Shin-Ae;Kang, Dae-Hun;Choi, Sang-Won
    • Preventive Nutrition and Food Science
    • /
    • v.15 no.2
    • /
    • pp.98-104
    • /
    • 2010
  • The seeds from two mulberry fruits [Morus alba (MA) and Cudrania tricuspidata (CT)] were examined for their oil content, and fatty acid, phytosterol and tocopherol compositions and contents. Moreover, polyphenolic compounds and biological activity of the two defatted seed residue extracts were also evaluated. Oil contents of MA and CT seeds were 29.36% and 16.69%, respectively, while MeOH extracts of the defatted MA and CT seed residues were 5.10% and 6.22%, respectively. The two seed oils were composed of 81.4 and 74.37% linoleic, 5.75 and 11.39% oleic, 8.40 and 10.18% palmitic acid, and 3.52 and 3.0% stearic acids, and two other minor fatty acids, such as linolenic and arachidic acids. MA seed had higher contents of phytosterols (507.59 mg/100 g of oil), tocopherols (99.64 mg/100 g of oil), and total flavonoid (106.50 mg/100 g of seed) than CT seed, whereas CT seed had higher levels of total polyphenol than MA seed. The MeOH extract of MA seed residue showed higher antioxidant, anti-diabetic, and anti-melanogenic activity than that of CT seed residue. trans-Resveratrol (9.62 mg/100 g), quercetin (54.83 mg/100 g), and 4-prenylmoracin (48.70 mg/100 g), were found to be the main polyphenolic components in the MeOH extract of MA seed residue. These results indicate that MA seeds are good sources of essential dietary phytochemicals with antioxidant, anti-diabetic and anti-melanogenic activity.

Use of positron emission tomography-computed tomography to predict axillary metastasis in patients with triple-negative breast cancer

  • Youm, Jung Hyun;Chung, Yoona;Yang, You Jung;Han, Sang Ah;Song, Jeong Yoon
    • Korean Journal of Clinical Oncology
    • /
    • v.14 no.2
    • /
    • pp.135-141
    • /
    • 2018
  • Purpose: Axillary lymph node dissection (ALND) and sentinel lymph node biopsy (SLNB) are important for staging of patients with node-positive breast cancer. However, these can be avoided in select micrometastatic diseases, preventing postoperative complications. The present study evaluated the ability of axillary lymph node maximum standardized uptake value (SUVmax) on positron emission tomography-computed tomography (PET-CT) to predict axillary metastasis of breast cancer. Methods: The records of invasive breast cancer patients who underwent pretreatment (surgery and/or chemotherapy) PET-CT between January 2006 and December 2014 were reviewed. ALNs were preoperatively evaluated by PET-CT. Lymph nodes were dissected by SLNB or ALND. SUVmax was measured in both the axillary lymph node and primary tumor. Student t-test and chi-square test were used to analyze sensitivity and specificity. Receiver operating characteristic (ROC) and area under the ROC curve (AUC) analyses were performed. Results: SUV-tumor (SUV-T) and SUV-lymph node (SUV-LN) were significantly higher in the triple-negative breast cancer (TNBC) group than in other groups (SUV-T: 5.99, P<0.01; SUV-LN: 1.29, P=0.014). The sensitivity (0.881) and accuracy (0.804) for initial ALN staging were higher in fine needle aspiration+PET-CT than in other methods. For PET-CT alone, the subtype with the highest sensitivity (0.870) and negative predictive value (0.917) was TNBC. The AUC for SUV-LN was greatest in TNBC (0.797). Conclusion: The characteristics of SUV-T and SUV-LN differed according to immunohistochemistry subtype. Compared to other subtypes, the true positivity of axillary metastasis on PET-CT was highest in TNBC. These findings could help tailor management for therapeutic and diagnostic purposes.

Study on the Improvement of Lung CT Image Quality using 2D Deep Learning Network according to Various Noise Types (폐 CT 영상에서 다양한 노이즈 타입에 따른 딥러닝 네트워크를 이용한 영상의 질 향상에 관한 연구)

  • Min-Gwan Lee;Chanrok Park
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.93-99
    • /
    • 2024
  • The digital medical imaging, especially, computed tomography (CT), should necessarily be considered in terms of noise distribution caused by converting to X-ray photon to digital imaging signal. Recently, the denoising technique based on deep learning architecture is increasingly used in the medical imaging field. Here, we evaluated noise reduction effect according to various noise types based on the U-net deep learning model in the lung CT images. The input data for deep learning was generated by applying Gaussian noise, Poisson noise, salt and pepper noise and speckle noise from the ground truth (GT) image. In particular, two types of Gaussian noise input data were applied with standard deviation values of 30 and 50. There are applied hyper-parameters, which were Adam as optimizer function, 100 as epochs, and 0.0001 as learning rate, respectively. To analyze the quantitative values, the mean square error (MSE), the peak signal to noise ratio (PSNR) and coefficient of variation (COV) were calculated. According to the results, it was confirmed that the U-net model was effective for noise reduction all of the set conditions in this study. Especially, it showed the best performance in Gaussian noise.

Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT (SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가)

  • Kim, Sang Gyu;Kim, Jung Yul;Park, Min Soo;Jo, Seung Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.3-7
    • /
    • 2014
  • Purpose SPECT/CT scan to be performed attenuation correction on the basis of CT induce an overestimation of the site due to the beam hardening artifact by metal cover and reduce the images quality. Therefore, this study using a phantom that has been inserted artificial hip joint investigated that effect on the SPECT/CT image causing by metal artifact for varying the parameters of the Attenuation Map. Materials and Methods Siemens Symbia T16 SPECT/CT equipment was used. Artificial hip joint was inserted to SPECT/PET phantom, 17 mm sphere of Bright Streak area in CT image was filled with Tc-99m so that the radiation activity was 8 times compared to background. And then Hot and Background was measured in varying Wide Beam Coefficient on Attenuation Map and RBR (Region to Background Ratio) of Metal and Non-Metal was calculated and analyzed depending on the presence or absence of the hip joint. Results It tended to hot count of Non-Metal and Metal to increase as the value of the manual mode is increased, hot count ratio with the group of both manual mode 0.5 and 0.4 is the best match. Also, in automatic mode, the ratio of RBRNon-Metal and RBRMetal was 1.135, statistically significant difference was not observed in the manual mode 0.5 and 0.4. Conclusion In the automatic mode of Wide Beam Coefficient in attenuation correction map, it was found that it is over-correction by 13.52%, it was possible to minimize the over-correction by the artifact in 0.5 and 0.4 of manual mode. Further studies should be performed in order to apply to a patient with the help of this and it is considered possible to reduce the over-correction by the metal artifact of an artificial hip joint for Hip-Resurfacing Arthroplasty patients, and to improve the diagnostic performance.

  • PDF

The Significance of Clinical Examination for Brain Lesion Differentiation of Patients with Head Trauma after Alcohol Intoxication

  • Jung, Yoon Hyun;Jeong, Dong Kil;Lee, Jung Won;Moon, Hyung Jun;Choi, Jae Hyung;Song, Jun Hwan
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.99-104
    • /
    • 2016
  • Purpose: There are many patients visited to ED in an alcohol intoxicated state. For these patients, it is difficult to predict by only clinical examination whether he/she would have brain lesion. The purpose of this study is to research whether it is possible to predict brain lesion by only clinical examination findings, with comparing patients with/without actual brain lesions. Methods: A retrospective study was performed at a university hospital for the period 11 months with the medical records. As for the inclusion group, head trauma patients with objectively proved drunk, judging by their blood ethanol concentration, and performed the brain CT were selected. In terms of medical record, Glasgow coma scale (GCS), the presence of neurologic abnormalities, the presence of lesion on brain CT of the patients, were examined. From laboratory results, blood ethanol concentration, platelet count, prothrombin time (PT), activated partial thromboplastin time (aPTT) and glucose concentration were identified. Results: For this study, there were total 80 patients of inclusion group. There was no statistically significant difference in terms of GCS score and neurological examination abnormalities, between the group with brain lesion and the group without brain lesion on brain CT. Conclusion: Alcohol intoxicated patient with head trauma visits the ED, it is not possible to distinguish or determine whether brain lesion exists or not by only clinical findings. In order to check the lesion existence, the image examination, therefore, should be considered and performed.

Inactivation Effect of Cryptosporidium by Ozone and UV (Ozone과 UV를 이용한 Cryptosporidium의 불활성화 효과)

  • Kim, Yun-Hee;Lee, Chul-Hee;Lee, Shun-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.31-39
    • /
    • 2007
  • The objective of this study was to investigate the inactivation characteristics of Cryptosporidium oocysts by ozone and UV and to suggest the better, disinfection method. The inactivation CT value of 1 log(90%) and 2 log(99%) in of one disinfection, which is an index of disinfection for inactivation effect by ozone, were respectively 5.77 $mg{\cdot}min/L$ and 21.30 $mg{\cdot}min/L$. The inactivation in UV disinfection was not affected by pHs(5, 7 and 9), low turbidity(5 and below NTU) and UV intensity(0.2 and 0.6 $mWs/cm^2$) but obviously decreased at high turbidity over 20 NTU. Therefore UV disinfection capacity can be obtained when a good turbidity removal in drinking water treatment process is achieved. And if oocysts is exposed by high UV over 0.6 mWs/cm2 during enough time, the better inactivation effect will be obtained.