• Title/Summary/Keyword: CT-scan

Search Result 1,337, Processing Time 0.026 seconds

A Study on Dose Response of MAGAT (Methacrylic Acid, Gelatin Gel and THPC) Polymer Gel Dosimeter Using X-ray CT Scanner (X-ray CT Scanner를 이용한 MAGAT (Methacrylic Acid, Gelatin Gel and THPC) 중합체 겔 선량계의 선량 반응성 연구)

  • Jung, Jae-Yong;Lee, Choong-Il;Min, Jeong-Hwan;Kim, Yon-Lae;Lee, Seong-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • In this study, we evaluated the dose response of MAGAT (Methacrylic Acid Gelatin gel and THPC) normoxic polymer gel dosimeters based on the X-ray CT scanner. To perform this study, we determined the proper ratio of the gel composition and acquired X-ray scan parameters. MAGAT gel dosimeters were manufactured using MAA (MethacrylicAcid) and gelatin of various concentration, irradiated up to 20 Gy. We obtained the 20 CT images from the irradiated gel dosimeters by using on a Phillips Brilliance Big Bore CT scanner with the various scan parameters. This CT images were used to determine the $N_{CT}$-dose response, dose sensitivity and dose resolution As an amount of MAA and gelatin were increase, the slope and intercept were increase in each MAGAT gel dosimeter with various concentration of the $N_{CT}$-dose response curve. The dose sensitivity was $0.38{\pm}0.08$ to $0.859{\pm}0.1$ and increased were amount of the MAA was increased or the gelatin was decreased. However, the change of gelatin concentration was very small compare to MAA. The Dose resolution ($D_{\Delta}^{95%}$) varies considerably from 2.6 to 6 Gy, dependent on dose resolution and CT image noise. The slope and dose sensitivity was almost ident verywith the variation of the tube voltage, tube current and slice thickness in the dose response curve, but the noise (standard deviation of averamalg CT number) was decreased when the tube voltage, tube current and slice thickness are increase. The optimal MAGAT polymer gel dosimeter based on the CT were evaluated to determine the CT imaging scan parameters of the maximum tube voltage, tube current and slice thickness (commonly used in clinical) using the composition ratio of a 9% MAA, 8% gelatin and 83% water. This study could get proper composition ratio and scan parameter evaluating dose response of MAGAT normoxic polymer gel dosimeter using CT scanner.

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

Evaluation of the Effective Methods for Renal Washout on $^{18}F$-FDG PET/CT ($^{18}F$-FDG PET/CT 검사에서 신장 방사능의 효과적인 배설 방법에 관한 연구)

  • Kim, Seong-Su;Kim, Jong-Cheol;Shin, Yong-Cheol;Lee, Sun-Do;Lee, Nam-Ju;Kim, Seung-Soo;Lee, Chun-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.55-59
    • /
    • 2010
  • Purpose: Renal excretion is the main route of FDG clearance in FDG PET/CT scan. Applying optimal method of renal excretion is very important for enhancing image quality and diagnostic accuracy. We evaluated several methods of renal excretion in FDG PET/CT scan. Materials and Methods: Thirty patients with normal renal function were prospectively included. Patients were divided into three group and undergone early and delayed FDG PET/CT scans. (1) Delay group; at 1 hour later of early scan, delayed scan was performed without additional hydration, (2) Hydration group; at 1 hour later of early scan, delayed scan was performed with additional oral hydration (700 mL of water), (3) Lasix group; lasix was administered at the end of early scan and dealyed scan was performed 30 min later. Early and delayed scans were compared to evaluate efficiency of renal excretion. Visual and quantitative analyses were performed by experienced physician and technologist of nuclear medicine. Results: On the visual analysis, renal excretion was the most evident in Lasix group followed by Hydration group. Delay group showed poor renal excretion. On the quantitative analysis, washout rates were $9.2{\pm}20.7%$, $28.1{\pm}22.8%$ and $29.5{\pm}23.1%$ for Delay, Hydration and Lasix groups, respectively. Conclusion: Administration of lasix was the best method for enhancing renal excretion. Delayed scan with hydration was also efficient method, but delayed scan without hydration was not adequate method.

  • PDF

Evaluation of Usefulness of Radio-iodine SPECT/CT in Differentiated Thyroid Cancer (분화성갑상선암에서 방사성요오드 SPECT/CT의 유용성 평가)

  • Lee, Jeong-Won;Lee, Ho-Young;Oh, So-Won;Kim, Seok-Ki;Jeong, Ki-Wook;Kim, Seon-Wook;Kang, Keon-Wook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.5
    • /
    • pp.350-358
    • /
    • 2007
  • Purpose: Localizing and differentiating a metastatic lesion of differentiated thyroid cancer (DTC) by using radio iodine whole body scan could be difficult because a whole body scan (WBS) lacks anatomic information. This study was performed to evaluate the usefulness of radio-iodine SPECT/CT for differentiating equivocal lesions. Materials & Methods: Among 253 patients with DTC who had undergone radio-iodine scan between February and July 2006, 26 patients were enrolled (M:F = 8:18, Age $50.7{\pm}12.5$ years) in this study. The patients had abnormal uptakes in the WBSs that necessitated precise anatomical localization for differentiating between a metastatic lesion and a false-positive lesion. SPECT/CT was performed for the region with abnormal uptake in the WBS. WBS and SPECT/CT were evaluated visually. Metastases were diagnosed based on the results of the radio-iodine scan along with the results of other radiological examinations and serological tests. Results: Based on the WBS images, 13 were suspected with cervical lymph node (LN) metastases in 16 patients with abnormal neck uptake, and in the 11 patients with abnormal extra-cervical uptakes, extra-cervical metastases were doubtful in all. After SPECT/CT was performed, the diagnostic results were altered for 16 patients (62%). SPECT/CT revealed that only 5 patients had cervical LN metastases, while 3 patients had extra-cervical (mediastinal) LN metastases. Overall, there was a 58% (15/26) change in diagnoses and plans for treatment due to SPECT/CT. Among 8 patients suspected with metastases on SPECT/CT, 6 patients underwent another radio-iodine therapy. In 96% (24/25) of the patients, the results of SPECT/CT corresponded with those of further radiological examinations and with other clinical information. Conclusion: Radio-iodine SPECT/CT images permitted the differentiation of abnormal radio-iodine uptake and improved anatomical interpretation in DTC.

Low-dose Chest CT in Evaluation of Coronary Artery Calcification: Correlation with Coronary Artery Calcium Score CT (관상동맥 석회화 평가에서 저선량 흉부 CT와 관상동맥 석회화검사의 일치도)

  • Yon-Min Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1033-1039
    • /
    • 2023
  • Low-dose chest CT, which is used as a lung screening test, also includes information on coronary artery calcification within the scan range. The purpose of this study was to investigate the usefulness of determining coronary artery calcification using Low-dose chest CT. Those who underwent low-dose chest CT and coronary artery calcification score CT on the same day were eligible. Coronary artery calcium score CT results were divided into 4 groups (Low: 1〈CACS〈10, Mild: 10〈CACS〈100, Moderate: 100〈CACS〈400, High: 400〈CACS) by referring to the Coronary artery calcium score categories and risks. After selecting 30 people each group, five radiotechnologists with more than 15 years of experience in coronary artery calcium measurement retrospectively analyzed the presence or absence of coronary artery calcification in low-dose chest CT images. The results of the five observers' uniform interpretation of the low-dose chest CT image were consistent with the coronary artery calcium score CT results in Low group: 56%, Mild group: 96.6%, Moderate group: 100%, and High group: 100%. appeared. In the Low group, all 5 observers observed calcification in 17 out of 30 cases, and in 7 cases all 5 observers decided that calcification could not be identified. Coronary artery calcification could be observed in 100% of asymptomatic adults with a calcium score of 15 or higher in low-dose chest CT scans. The minimum calcium score that can be identified is 1, and it was found that even very small calcifications can be identified when the subject's body size is small or the scan is performed at a time when heart movement is minimal.

A Comparative Evaluation of Organ Doses in Infants and toddlers between Axial and Spiral CT Scanning (축방향 CT 스캔과 나선형 CT 스캔에서 영·유아의 장기흡수선량 비교 평가)

  • Kim, Sangtae;Eun, Sungjong;Kim, Sunggil
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • This study presents comparison results between axial and spiral scanning in the head and chest region with 64 MDCT to evaluate organ doses in infants and toddlers, who are more radiosensitive to radiation than adults and rise in the number of CT examinations, during CT scanning. Organ doses were significantly lower in spiral scanning than axial scanning regardless of scanned regions. The average organ dose for the chest scan using pitch of 1.355 was found to be significantly higher(average -12.03%) than for the other two pitch settings(0.525 and 0.988) in the spiral scanning mode compared with the axial one. Organ doses in the spiral scanning mode were lower by average 20.54% than the axial scanning mode. The results of the study that evaluated organ doses with an anthropomorphic phantom will help to demonstrate the result values of Monte Carlo simulations and make a contribution to more accurate evaluations of organ doses in toddlers undergoing a CT examination.

An Iterative Image Reconstruction Method for the Region-of-Interest CT Assisted from Exterior Projection Data (Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.132-141
    • /
    • 2014
  • In an ordinary CT scan, a large number of projections with full field-of-view (FFOV) are necessary to reconstruct high resolution images. However, excessive x-ray dosage is a great concern in FFOV scan. Region-of-interest (ROI) CT or sparse-view CT is considered to be a solution to reduce x-ray dosage in CT scanning, but it suffers from bright-band artifacts or streak artifacts giving contrast anomaly in the reconstructed image. In this study, we propose an image reconstruction method to eliminate the bright-band artifacts and the streak artifacts simultaneously. In addition to the ROI scan for the interior projection data with relatively high sampling rate in the view direction, we get sparse-view exterior projection data with much lower sampling rate. Then, we reconstruct images by solving a constrained total variation (TV) minimization problem for the interior projection data, which is assisted by the exterior projection data in the compressed sensing (CS) framework. For the interior image reconstruction assisted by the exterior projection data, we implemented the proposed method which enforces dual data fidelity terms and a TV term. The proposed method has effectively suppressed the bright-band artifacts around the ROI boundary and the streak artifacts in the ROI image. We expect the proposed method can be used for low-dose CT scans based on limited x-ray exposure to a small ROI in the human body.

Primary Hepatosplenic B-cell Lymphoma: linitial Diagnosis and Assessment of Therapeutic Response with F-18 FDG PET/CT (원발성 간비장 B세포성 림프종에서 치료전과 치료 후 F-18 FDG PET/CT 소견)

  • Kang, Sung-Min;Lee, Hong-Je;Seo, Ji-Hyoung;Lee, Sang-Woo;Ahn, Byeong-Cheol;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.333-336
    • /
    • 2008
  • A 52-year-old woman with a history of general weakness, fatigue, weight loss, elevated serum levels of liver transaminase enzyme for three months underwent an F-18 FDG PET/CT scan to evaluate a cause of the hepatosplenomegaly found on abdominal ultrasonography. Initial PET/CT revealed markedly enlarged liver and spleen with intense FDG uptake. Otherwise, there were no areas of abnormal FDG uptake in whole body image. Histological evaluation by a hepatic needle biopsy demonstrated diffuse large B cell type lymphoma and final diagnosis for this patient was hepatosplenic B-cell lymphoma. She received five cycles of CHOP chemotherapy, and second PET/CT scan was followed after then. Follow-up PET-CT revealed normal sized liver with disappearance of abnormal FDG uptake. Hepatosplenic B-cell lymphoma is relatively rare and mostly presents as single or multiple nodules.1,2 Diffuse type hepatosplenic lymphoma is extremely rare and poorly recognized entity.3 The diagnosis is very difficult and complicated by the presence of misleading symptoms.4 In this rare hepatosplenic B-cell lymphoma case, F-18 FDG PET/CT scan provided a initial diagnostic clue of hepatosplenic lymphoma and an accurate chemotherapy response.

A Study on Radiation Dose and Image Quality according to CT Table Height in Brain CT (두부 CT 검사 시 테이블 높이에 따른 선량과 화질에 관한 연구)

  • Ki-Won Kim;Joo-Young Oh;Jung-Whan Min;Sang-Sun Lee;Young-Bong Lee;Kyung-Hwan Lim;Yun Yi
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.99-106
    • /
    • 2023
  • The height of the table should be considered important during computed tomography (CT) examination, but according to previous studies, not all radiology technologists set the table at the patient's center at the examination, which affects the exposure dose and image quality received by the patient. Therefore, this study intends to study the image quality exposure dose according to the height of the table to realize the optimal image quality and dose during the brain CT scan. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. For the exposure dose measurement, optically stimulated luminescence dosimeter (OSLD) was attached to the front, side, eye, and thyroid gland of the head phantom. In the signal to noise ratio (SNR) measurement result, The SNR values for each table height were all lower than 915 mm. As a result of exposure dose, the exposure dose on each area increased as the table height decreased. The height of the table has a close relationship with the patient's radiation exposure dose in the CT scan.