• Title/Summary/Keyword: CT-MRI Fusion

Search Result 24, Processing Time 0.023 seconds

Dependency of Generator Performance on T1 and T2 weights of the Input MR Images in developing a CycleGan based CT image generator from MR images (CycleGan 딥러닝기반 인공CT영상 생성성능에 대한 입력 MR영상의 T1 및 T2 가중방식의 영향)

  • Samuel Lee;Jonghun Jeong;Jinyoung Kim;Yeon Soo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.37-44
    • /
    • 2024
  • Even though MR can reveal excellent soft-tissue contrast and functional information, CT is also required for electron density information for accurate dose calculation in Radiotherapy. For the fusion of MRI and CT images in RT treatment planning workflow, patients are normally scanned on both MRI and CT imaging modalities. Recently deep-learning-based generations of CT images from MR images became possible owing to machine learning technology. This eliminated CT scanning work. This study implemented a CycleGan deep-learning-based CT image generation from MR images. Three CT generators whose learning is based on T1- , T2- , or T1-&T2-weighted MR images were created, respectively. We found that the T1-weighted MR image-based generator can generate better than other CT generators when T1-weighted MR images are input. In contrast, a T2-weighted MR image-based generator can generate better than other CT generators do when T2-weighted MR images are input. The results say that the CT generator from MR images is just outside the practical clinics and the specific weight MR image-based machine-learning generator can generate better CT images than other sequence MR image-based generators do.

Preliminary Application of Synthetic Computed Tomography Image Generation from Magnetic Resonance Image Using Deep-Learning in Breast Cancer Patients

  • Jeon, Wan;An, Hyun Joon;Kim, Jung-in;Park, Jong Min;Kim, Hyoungnyoun;Shin, Kyung Hwan;Chie, Eui Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.4
    • /
    • pp.149-155
    • /
    • 2019
  • Background: Magnetic resonance (MR) image guided radiation therapy system, enables real time MR guided radiotherapy (RT) without additional radiation exposure to patients during treatment. However, MR image lacks electron density information required for dose calculation. Image fusion algorithm with deformable registration between MR and computed tomography (CT) was developed to solve this issue. However, delivered dose may be different due to volumetric changes during image registration process. In this respect, synthetic CT generated from the MR image would provide more accurate information required for the real time RT. Materials and Methods: We analyzed 1,209 MR images from 16 patients who underwent MR guided RT. Structures were divided into five tissue types, air, lung, fat, soft tissue and bone, according to the Hounsfield unit of deformed CT. Using the deep learning model (U-NET model), synthetic CT images were generated from the MR images acquired during RT. This synthetic CT images were compared to deformed CT generated using the deformable registration. Pixel-to-pixel match was conducted to compare the synthetic and deformed CT images. Results and Discussion: In two test image sets, average pixel match rate per section was more than 70% (67.9 to 80.3% and 60.1 to 79%; synthetic CT pixel/deformed planning CT pixel) and the average pixel match rate in the entire patient image set was 69.8%. Conclusion: The synthetic CT generated from the MR images were comparable to deformed CT, suggesting possible use for real time RT. Deep learning model may further improve match rate of synthetic CT with larger MR imaging data.

Do Obliquity and Position of the Oblique Lumbar Interbody Fusion Cage Influence the Degree of Indirect Decompression of Foraminal Stenosis?

  • Mahatthanatrakul, Akaworn;Kotheeranurak, Vit;Lin, Guang-Xun;Hur, Jung-Woo;Chung, Ho-Jung;Lokanath, Yadhu K;Pakdeenit, Boonserm;Kim, Jin-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.1
    • /
    • pp.74-83
    • /
    • 2022
  • Objective : Oblique lumbar interbody fusion (OLIF) is a surgical technique that utilizes a large interbody cage to indirectly decompress neural elements. The position of the cage relative to the vertebral body could affect the degree of foraminal decompression. Previous studies determined the position of the cage using plain radiographs, with conflicting results regarding the influence of the position of the cage to the degree of neural foramen decompression. Because of the cage obliquity, computed tomography (CT) has better accuracy than plain radiograph for the measurement of the obliquely inserted cage. The objective of this study is to find the correlation between the position of the OLIF cage with the degree of indirect decompression of foraminal stenosis using CT and magnetic resonance imaging (MRI). Methods : We review imaging of 46 patients who underwent OLIF from L2-L5 for 68 levels. Segmental lordosis (SL) was measured in a plain radiograph. The positions of the cage were measured in CT. Spinal canal cross-sectional area (SCSA), and foraminal crosssectional area (FSCA) measurements using MRI were taken into consideration. Results : Patients' mean age was 69.7 years. SL increases 3.0±5.1 degrees. Significant increases in SCSA (33.3%), FCSA (43.7% on the left and 45.0% on the right foramen) were found (p<0.001). Multiple linear regression analysis shows putting the cage in the more posterior position correlated with more increase of FSCA and decreases SL correction. The position of the cage does not affect the degree of the central spinal canal decompression. Obliquity of the cage does not result in different degrees of foraminal decompression between right and left side neural foramen. Conclusion : Cage position near the posterior part of the vertebral body increases the decompression effect of the neural foramen while putting the cage in the more anterior position correlated with increases SL.

Radiologic Findings and Risk Factors of Adjacent Segment Degeneration after Anterior Cervical Discectomy and Fusion : A Retrospective Matched Cohort Study with 3-Year Follow-Up Using MRI

  • Ahn, Sang-Soak;So, Wan-Soo;Ku, Min-Geun;Kim, Sang-Hyeon;Kim, Dong-Won;Lee, Byung-Hun
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.2
    • /
    • pp.129-136
    • /
    • 2016
  • Objective : The purpose of this study was to figure out the radiologic findings and risk factors related to adjacent segment degeneration (ASD) after anterior cervical discectomy and fusion (ACDF) using 3-year follow-up radiography, computed tomography (CT), and magnetic resonance image (MRI). Methods : A retrospective matched comparative study was performed for 64 patients who underwent single-level ACDF with a cage and plate. Radiologic parameters, including upper segment range of motion (USROM), lower segment range of motion (LSROM), upper segment disc height (UDH), and lower segment disc height (LDH), clinical outcomes assessed with neck and arm visual analogue scale (VAS), and risk factors were analyzed. Results : Patients were categorized into the ASD (32 patients) and non-ASD (32 patients) group. The decrease of UDH was significantly greater in the ASD group at each follow-up visit. At 36 months postoperatively, the difference for USROM value from the preoperative one significantly increased in the ASD group than non-ASD group. Preoperative other segment degeneration was significantly associated with the increased incidence of ASD at 36 months. However, pain intensity for the neck and arm was not significantly different between groups at any post-operative follow-up visit. Conclusion : The main factor affecting ASD is preoperative other segment degeneration out of the adjacent segment. In addition, patients over the age of 50 are at higher risk of developing ASD. Although there was definite radiologic degeneration in the ASD group, no significant difference was observed between the ASD and non-ASD groups in terms of the incidence of symptomatic disease.

Quantitative Feasibility Evaluation of 11C-Methionine Positron Emission Tomography Images in Gamma Knife Radiosurgery : Phantom-Based Study and Clinical Application

  • Lim, Sa-Hoe;Jung, Tae-Young;Jung, Shin;Kim, In-Young;Moon, Kyung-Sub;Kwon, Seong-Young;Jang, Woo-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.476-486
    • /
    • 2019
  • Objective : The functional information of $^{11}C$-methionine positron emission tomography (MET-PET) images can be applied for Gamma knife radiosurgery (GKR) and its image quality may affect defining the tumor. This study conducted the phantom-based evaluation for geometric accuracy and functional characteristic of diagnostic MET-PET image co-registered with stereotactic image in Leksell $GammaPlan^{(R)}$ (LGP) and also investigated clinical application of these images in metastatic brain tumors. Methods : Two types of cylindrical acrylic phantoms fabricated in-house were used for this study : the phantom with an array-shaped axial rod insert and the phantom with different sized tube indicators. The phantoms were mounted on the stereotactic frame and scanned using computed tomography (CT), magnetic resonance imaging (MRI), and PET system. Three-dimensional coordinate values on co-registered MET-PET images were compared with those on stereotactic CT image in LGP. MET uptake values of different sized indicators inside phantom were evaluated. We also evaluated the CT and MRI co-registered stereotactic MET-PET images with MR-enhancing volume and PET-metabolic tumor volume (MTV) in 14 metastatic brain tumors. Results : Imaging distortion of MET-PET was maintained stable at less than approximately 3% on mean value. There was no statistical difference in the geometric accuracy according to co-registered reference stereotactic images. In functional characteristic study for MET-PET image, the indicator on the lateral side of the phantom exhibited higher uptake than that on the medial side. This effect decreased as the size of the object increased. In 14 metastatic tumors, the median matching percentage between MR-enhancing volume and PET-MTV was 36.8% on PET/MR fusion images and 39.9% on PET/CT fusion images. Conclusion : The geometric accuracy of the diagnostic MET-PET co-registered with stereotactic MR in LGP is acceptable on phantom-based study. However, the MET-PET images could the limitations in providing exact stereotactic information in clinical study.

Development of a Brain Phantom for Multimodal Image Registration in Radiotherapy Treatment Planning

  • H. S. Jin;T. S. Suh;R. H. Juh;J. Y. Song;C. B. Y. Choe;Lee, H .G.;C. Kwark
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.450-453
    • /
    • 2002
  • In radiotherapy treatment planning, it is critical to deliver the radiation dose to tumor and protect surrounding normal tissue. Recent developments in functional imaging and radiotherapy treatment technology have been raising chances to control tumor saving normal tissues. A brain phantom which could be used for image registration technique of CT-MR and CT-SPECT images using surface matching was developed. The brain phantom was specially designed to obtain imaging dataset of CT, MR, and SPECT. The phantom had an external frame with 4 N-shaped pipes filled with acryl rods, Pb rods for CT, MR, and SPECT imaging, respectively. 8 acrylic pipes were inserted into the empty space of the brain phantom to be imaged for geometric evaluation of the matching. For an optimization algorithm of image registration, we used Downhill simplex algorithm suggested as a fast surface matching algorithm. Accuracy of image fusion was assessed by the comparison between the center points of the section of N-shaped bars in the external frame and the inserted pipes of the phantom and minimized cost functions of the optimization algorithm. Technique with partially transparent, mixed images using color on gray was used for visual assessment of the image registration process. The errors of image registration of CT-MR and CT-SPECT were within 2mm and 4mm, respectively. Since these errors were considered within a reasonable margin from the phantom study, the phantom is expected to be used for conventional image registration between multimodal image datasets..

  • PDF

Invasion of Hemangiosarcoma from Lung to the Spinal Cord in a Dog (개에서 발생한 폐 원발성 혈관육종의 척수로의 전이)

  • Choi, Sung-Jin;Nam, Eun-Ryel;Lee, Gi-Ja;Kim, Nam-Soo;Murahashi, Tatsumi;Nishimura, Ryouhei;Mochizuki, Manabu
    • Journal of Veterinary Clinics
    • /
    • v.31 no.2
    • /
    • pp.145-148
    • /
    • 2014
  • 11-year-old neutered male dog was presented with paralysis with decreased postural reaction in the bilateral pelvic limbs. On MRI and CT, the spinal cord from T13 had a slightly swollen area and lost the central canal. A well circumscribed mass was observed at anterior of a right kidney and invaded the spinal canal through the pleura without the fusion and destruction of the spines. Hemilaminectomy was performed to identify the mass pathohistologically and decompress the spinal cord. The mass was diagnosed as hemangiosarcoma. The dog had showed neither progressive neurologic disorders nor improvement and passed away 58 days after the surgery.

Os Odontoideum Corresponding to Absolute Contra-Indications of Chuna Manipulation Treatment : A Case Report (추나치료의 절대적 금기증에 대한 보고 1례 - Os Odontoideum을 진단받은 환자를 대상으로 -)

  • Moon, Tae-Woong;Eom, Tae-Woong;Kang, Myung-Jin;Kong, Duck-Hyun;Chung, Young-Hoon;Cho, Tae-Young;Kim, Ki-Joo;Lee, Kwang-Hwan
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.3 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • Objectives : The os odontoideum is an uncommon abnormality which is due to non fusion of axis and odontoid process that exists as a separate ossicle apart from a hypoplastic dens. Its clinical significance lies in its potential to produce serious neurologic symptoms after cervical Chuna Manipulation Treatment. We experienced a patient diagnosed as os odontoideum which corresponds to absolute contra-indications of chuna manipulation treatment and report it. Methods : The patient was diagnosed as os odontoideum through cervical spine CT and MRI. Results and Conclusion : During cervical physical examination, we encountered L'hermitte's phenomenon from the patient and suspected one of contra-indications of chuna manipulation treatment. We could diagnose the patient as os odontoideum through cervical spine CT, MRI and prevent him from severe sequelae caused by chuna manipulation treatment.

  • PDF

Imaging Evaluation of Early and Long-Term Complications Associated with the Postoperative Spine (척추 수술 후 영상 평가: 초기 및 중장기 합병증)

  • Jae Hwi Park;Dong Hyun Kim;Jee Won Chai;Hyo Jin Kim;Jiwoon Seo;Jin Young Son
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.36-53
    • /
    • 2024
  • As the number of spinal surgeries being performed expands, the number of medical imaging procedures such as radiography, CT, and MRI is also increasing, and the importance of their interpretation is becoming more significant. Herein, we present the radiological findings of a variety of complications that can occur after spinal surgery and discuss how effectively and accurately they can be diagnosed through imaging. In particular, this study details the characteristic imaging findings specific to the early and long-term postoperative periods. Early complications of spinal surgery include improper placement of surgical instruments (instrument malpositioning), seromas, hematomas, pseudomeningoceles, and infections in the region surrounding the surgical site. Conversely, long-term complications may include osteolysis around surgical instruments, failure of fusion, adjacent segment disease, and the formation of epidural fibrosis or scar tissue. A precise understanding of the imaging assessments related to complications arising after spinal surgery is crucial to ensure timely and accurate diagnosis, which is necessary to achieve effective treatment.