• Title/Summary/Keyword: CT values

Search Result 689, Processing Time 0.026 seconds

Reduction of Carbon Tetrachloride at Different pHs in Pyrolusite Catalyzed Fenton-like reduction (Pyrolusite으로 촉매화된 펜톤유사반응에서 pH변화에 따른 사염화탄소(CT)의 환원분해)

  • 김상민;공성호;김용수;허정욱
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.231-234
    • /
    • 2002
  • According to recent investigations regarding Fenton-like reaction, it was reported that there was a key factor to decompose organic materials by not only the hydoroxyl radical but also several reductants which were superoxide anion and hydroperoxide anion. This research was focused on an investigation of the decomposition of carbon tetrachloride(CT) by reductants which were generated by pyrolusite with hydrogen peroxide. Generally, CT decomposition rate increased with raising pH values. Especially,, CT was decomposed over 60 percent by 10,000 ppm of hydrogen peroxide within 10 minutes in neutral condition. In addition, the decomposition of chlorinated compounds would be accelerated in alkaline condition, even with low concentration of hydrogen peroxide.

  • PDF

A Case of Paragonimiasis that was Suspicious for a Lung Malignancy by PET/CT (PET/CT에서 폐암으로 의심된 폐흡충증 1예)

  • Moon, You Ri;Lee, Yang Deok;Park, Sang Hyun;Cho, Yong Soo;Na, Dong Jib;Cho, Yong Seon;Han, Min Soo;Choi, Hee Jeong;Kim, Do Hyung;Yang, Seoung Oh;Kim, Kyung Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.6
    • /
    • pp.521-525
    • /
    • 2007
  • Positron emission tomography/computed tomography (PET/CT) is valuable for the diagnosis of malignancies. However, PET/CT is unable to discriminate exactly between inflammation and a neoplasm. We report a case of a 50-year-old man with pulmonary paragonimiasis that was suspicious for lung cancer, as detected by PET/CT. The use of PET/CT revealed multilobulated consolidation on the right lung and patchy consolidation on the left lung, with increased fluorodeoxyglucose (FDG) uptake. In addition, the left paraaortic lymph node (LN) and peripancreatic LN showed enlargement with increased FDG uptake. Lung cancer with multiple lymph node metastases was suspected from the increased standardized uptake values (SUV>4.5) determined by PET/CT. We performed wedge resection via video-assisted thoracic surgery (VATS) and found Paragonimus westermani eggs in the involved tissues.

Effect of Iterative-metal Artifact Reduction (iMAR) at Tomotherapy: a Phantom Study (토모테라피에서 반복적 금속 인공물 감소 알고리즘의 유용성 평가: 팬톰 실험)

  • Daegun, Kim;Jaehong, Jung;Sungchul, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.709-718
    • /
    • 2022
  • We evaluated the effect of high-density aluminum, titanium, and steel metal inserts on computed tomography (CT) numbers and radiation treatment plans for Tomotherapy. CT images were obtained using a cylindrical TomoPhantom comprising cylindrical rods of various densities and metal inserts. Three CT image sets were evaluated for image quality as the mean CT number and standard deviation. Dose evaluation also performed. The reference values did not significantly differ between the CT image sets with the corrected metal inserts. The higher-density material exhibited the largest difference in the mean CT number and standard deviation. The conformity index at Iterative-Metal Artifact Reduction (iMAR) was approximately 20% better than that of non-iMAR. No significant target or organ at risk dose difference was observed between non-iMAR and iMAR. Therefore, iMAR is helpful for target or organ at risk delineation and for reducing uncertainty for three-dimensional conformal radiation therapy in Tomotherapy.

EFFECT OF RHPDGF-BB AND RHBMP-2 ON OSSEOINTEGRATION OF TITANIUM IMPLANTS AT PERIIMPLANT BONE DEFECTS GRAFTED WITH HYDROXYAPATITE: MICRO-CT AND HISTOLOGIC ANALYSIS (Hydroxyapatite를 이식한 임플란트 주위 골결손부에서 rhPDGF-BB와 rhBMP-2가 골내 임플란트 osseointegration에 미치는 영향: Micro-CT 분석과 조직학적 평가)

  • Park, Jee-Hyun;Hwang, Sun-Jung;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.461-468
    • /
    • 2009
  • Purpose: Platelet derived growth factor(PDGF)-BB and bone morphogenetic protein(BMP)-2 are well-known representative growth factors. The purposes of this study were to investigate the effect of rhPDGFBB and rhBMP-2 on osseointegration of titanium implants at periimplant bone defects grafted with hydroxyapatite and to evaluate the feasibility of imaging bone structures around screw-type titanium implant with micro-CT. Materials and Methods: The first molar and all premolars in the mandible region of four beagle dogs were extracted. Following a healing period of 4 months, three $8{\times}8{\times}6mm$-sized bony defects were formed and screw-type titanium implants were placed with hydroxyapatite(HA) block and growth factors; Control group, PDGF group and BMP group. Two months post-implantation, the mandible was harvested. Bone volume(BV), bone-to-implant contact(BIC) and bone mineral density(BMD) were analyzed with micro-CT and histology. Results: According to micro-CT analysis, BV and BMD measures of PDGF and BMP group were significantly higher than control group(BV; PDGF group: $p{\fallingdotseq}0.011$, BMP group: $p{\fallingdotseq}0.006$/BMD; PDGF group: $p{\fallingdotseq}0.020$, BMP group: $p{\fallingdotseq}0.011$) and BIC measures of BMP group were significantly higher than PDGF group($p{\fallingdotseq}0.015$). In histologic evaluation, BIC measures of BMP group was significantly higher than PDGF group($p{\fallingdotseq}0.048$). The values of BV in histologic sections were higher than in micro-CT images and the values of BIC in micro-CT images were higher than in histologic sections. Conclusion: The findings of this experimental study indicates that the use of rhPDGF-BB and rhBMP-2 can increase new bone formation in a large bony defect around titanium implant, and rhBMP-2 is more effective than rhPDGF-BB. Micro-CT can be considered useful for assessment as a rapid and nondestructive method for 3-dimensional measurement of bone healing around implants. Further study is necessary, however, to remove metal artifacts around titanium implant and to standardize the method.

Comparison of CT Image Performance with or without Tin Filter based on Blind Image Quality Evaluation Method (블라인드 품질 평가 방법을 사용한 주석필터 사용 유무에 따른 CT 영상 특성 비교)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.301-306
    • /
    • 2021
  • The use of tin filters as a way to reduce the medical radiation in computed tomography (CT). However, due to the changed X-ray spectrum with the use of tin filters, disease diagnosis could be affected because it appears as images of different impressions from previous images. Therefore, this study evaluates the changes in images when using tin filter and high pitch in chest low-dose CT. In this study, images were acquired in groups of three for comparison. Group 1 did not apply to tin filter, and used the existing pitch 0.8. Group 2 used a tin filter, pitch 0.8, Group 3 used a tin filter, and pitch 2.5. To compare the image quality, the natural image quality evaluator (NIQE) and the blind/referenceless image quality evaluator (BRISQUE) were used among the blind quality evaluation factors depended on a no-reference basis. As a result, the NIQE values were low in the order of Group 1, Group 3, and Group 2. BRISQUE values were low in the order of Group 3, Group 2 and Group 1. This study confirms the superiority of images of tin filter and high pitch techniques in chest low-dose CT, which is considered to be a fundamental study for acquiring accurate images of patients with difficult breathing control.

Three-dimensional CT based Quantitative Assessment of Normal and Dysplasia Acetabulum (정상 및 이형성 비구의 고해상 CT를 이용한 정량적 분석)

  • An, Eun-Soo;Lee, Soon-Hyuck;Park, Sang-Won;Park, Jong-Hoon;Suh, Dong-Hun;Noh, Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.8
    • /
    • pp.126-131
    • /
    • 2009
  • Acetabular dysplasia is a condition defined by inadequate development of an individual's acetabulum. Individual diversity of the symptoms in this disease needs safe and accurate preoperative planning. Technologies that utilize multidimensional image information are thus important. The assessment method by Janzen et al. was suggested a coefficient method in evaluation of acetabular dysplasia. In this study, we applied it, using a three-dimensional computed tomography (3D CT) on the koreans. 19 cases of the normal hips and 4 cases of the acetabular dysplasia were investigated to evaluate the proved method; 3D CT was used to define the geometric center of the femoral head and to measure center edge angles at $10^{\circ}$ rotational increments around the acetabular rim. Mean and standard deviation in CEAs (Center Edge Angle) of normal 19 hips at $10^{\circ}$ rotational increments from anterior to posterior rim were determined, and termed as a 'normal curve'. Then this normal values were compared with the CEA data measured from 4 cases of acetabular dysplasia patiens. Quantative comparison of the CEA values between the normal cases and dysplasia cases was successfully demonstrated, and thus, we claim that this simple CT method of assessing acetabular dysplasia can be well applicable to diagnosis, quantification and surgical planning for adult acetabular dysplasia patients.

Morphometric analysis of bone in the ovariectomized rat using in vivo micro-CT (In vivo micro-CT를 이용한 난소적출 백서의 골구조 형태계측학적 분석)

  • Lee, Chang-Jin;Lee, Wan;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.29-37
    • /
    • 2008
  • Purpose: The aim of this study was to observe the bony change in the OVX rat longitudinally and to study the alendronate effect. Materials and Methods: Eighteen Sprague-Dewley rats, eight-week old each, were randomly assigned into three groups: one of those sham-operated (N=4), the other two were OVX: saline-treated (N=7) and alendronate-treated group (N=7). The saline-treated group was administered with saline solution (0.1mL/100g) daily, while the alendronate-treated group was given alendronate (1mg/kg, Sigma-Aldrich Corp. Korea) daily. Micro-CT scannings of the lumbar were consecutively done at baseline, at 3-week intervals during 9 weeks. Two and three dimensional bony analysis were done. Bone mineral density (BMD) was measured with Piximus (GE Lunar Co. USA). The average values of these three methods were compared with each group. Results: After 6 weeks the BMD of the OVX group showed lower tendency than that of sham group. After 6 weeks many 3D parameters of micro-CT showed higher values in the OVX-alendronate group compared with the OVXsaline group. Most 2D bony parameters were higher in the OVX-alendronate group compared with the OVX-saline group at 9 weeks. Conclusion: This study showed low BMD of the OVX group after 6 weeks and showed the effect of alendronate on the BMD and bony structures of ovariectomized rats. This study also showed usefulness of in vivo micro-CT in monitoring individual bone changes over time.

  • PDF

Effect of Image quality and Radiation Dose using Iterative Reconstruction in Adult and Pediatric CT: A Phantom Study (성인과 소아 CT 촬영시 IR 적용에 따른 영상화질 및 선량에 미치는 영향)

  • Ju, A-ran;Jo, Jung-Hyun;Oh, Young-Kyu;Kim, Kyoung-Ki;Lee, Soo-Been;Jeon, Pil-Hyun;Kim, Daehong
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.1
    • /
    • pp.23-31
    • /
    • 2018
  • The main issue of CT is radiation dose reduction to patient. The purpose of this study was to estimate the image quality and dose by iterative reconstruction (IR) for adults and pediatrics. Adult and pediatric images of phantom were obtained with 120 and 140 kV, respectively, in accordance with radiation dose in terms of volume CT dose index ($CTDI_{vol}$): 10, 15, 20, 25, 30, 35 mGy. Then, the adult and the pediatric images are reconstructed by filtered-backprojection (FBP) and iterative reconstruction (IR). The images were analyzed by signal-to-noise ratio (SNR). SNR is improved when IR and 140 kV are applied to acquire adult and pediatric images. In the adult abdomen, according to diagnostic reference level, the SNR values of bone were increased about 27.84 % and 27.77 % at 120 kV and 140 kV, and the tissue's SNR values of the IR were increased about 29.84 % and 33.46 % 120 and 140 kV, respectively. Dose is reduced to 40% in adults abdomen images when using IR reconstruction. In pediatric images, the bone's SNR were also increased about 17.70% and 18.17 % at 120 kV and 140 kV. The tissue's SNR were increased about 26.73 % and 26.15 % at 120 kV and 140 kV. Radiation dose is reduced from 30% to 50% for bone and tissue images. In the case of examinations for adult and pediatric CT, IR technique reduces radiation dose to patient, and it could be applied to adult and pediatric imaging.

Comparison of radiographic and computed tomographic acetabular index in small-breed dogs: a preliminary study using Maltese and Shih Tzu

  • Kanthavichit, Kanokporn;Klaengkaew, Auraiwan;Thanaboonnipat, Chutimon;Darawiroj, Damri;Soontornvipart, Kumpanart;Choisunirachon, Nan
    • Journal of Veterinary Science
    • /
    • v.22 no.4
    • /
    • pp.58.1-58.13
    • /
    • 2021
  • Background: The morphometry of the acetabulum is one source of information that assists in the clinical diagnosis of the hip and influences the proper selection of a prosthesis, reducing post-operative complications such as those seen in total hip replacement (THR). However, acetabular parameters in small-breed dogs are rarely reported. Objectives: To investigate acetabular parameters using radiography and computed tomography (CT) in small-breed dogs with Maltese and Shih Tzu dogs used as model breeds. Methods: Standard calibrated, extended hip radiographs and CT images were obtained. Subsequently, acetabular width (AW) in various directions was measured using radiography and CT, whereas acetabular depth (AD) was obtained by CT. Acetabular index (AI) is a ratio calculated from AD and AW. Results: The values of AW and AD were much higher in Shih Tzu than in Maltese dogs. Male Shih Tzus showed higher values of these parameters than females, while sex-based differences in most of the parameters could not be detected in Maltese. Body weight, but not age, influenced AWs and ADs. While AWs and ADs were influenced by several factors, AI was comparable among the assessed factors and between Maltese and Shih Tzu dogs (p = 0.172; 31.42 ± 1.35 and 32.60 ± 1.80, respectively). Also, AI did not vary with breed, sex, or body size. Conclusions: The obtained radiographic and CT acetabular parameters could be useful as guidelines for evaluating the acetabulum of small-breed dogs in clinical practice.

Correlation between gray values of cone-beam computed tomograms and Hounsfield units of computed tomograms: A systematic review and meta-analysis

  • Selvaraj, Abirami;Jain, Ravindra Kumar;Nagi, Ravleen;Balasubramaniam, Arthi
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.133-140
    • /
    • 2022
  • Purpose: The aim of this review was to systematically analyze the available literature on the correlation between the gray values (GVs) of cone-beam computed tomography (CBCT) and the Hounsfield units (HUs) of computed tomography (CT) for assessing bone mineral density. Materials and Methods: A literature search was carried out in PubMed, Cochrane Library, Google Scholar, Scopus, and LILACS for studies published through September 2021. In vitro, in vivo, and animal studies that analyzed the correlations GVs of CBCT and HUs of CT were included in this review. The review was prepared according to the PRISMA checklist for systematic reviews, and the risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. A quantitative analysis was performed using a fixed-effects model. Results: The literature search identified a total of 5,955 studies, of which 14 studies were included for the qualitative analysis and 2 studies for the quantitative analysis. A positive correlation was observed between the GVs of CBCT and HUs of CT. Out of the 14 studies, 100% had low risks of bias for the domains of patient selection, index test, and reference standards, while 95% of studies had a low risk of bias for the domain of flow and timing. The fixed-effects meta-analysis performed for Pearson correlation coefficients between CBCT and CT showed a moderate positive correlation (r=0.669; 95% CI, 0.388 to 0.836; P<0.05). Conclusion: The available evidence showed a positive correlation between the GVs of CBCT and HUs of CT.